Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hydrostaticity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Hydrostatic Hyperbaric Chamber Ventilation System

The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy (HBOT) available in the developing world for the treatment of a variety of medical conditions. Specifically, HBOT is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. HBOT is simply too expensive and too dangerous to implement in the developing world using standard equipment. The HHC technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system to provide controlled pressurization and adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware, supports sustainability.

Sarguisingh, Miriam J.↗

File Specification for the 7-km GEOS-5 Nature Run, Ganymed Release Non-Hydrostatic 7-km Global Mesoscale Simulation

This document describes the gridded output files produced by a two-year global, non-hydrostatic mesoscale simulation for the period 2005-2006 produced with the non-hydrostatic version of GEOS-5 Atmospheric Global Climate Model (AGCM). In addition to standard meteorological parameters (wind, temperature, moisture, surface pressure), this simulation includes 15 aerosol tracers (dust, sea-salt, sulfate, black and organic carbon), O3, CO and CO2. This model simulation is driven by prescribed sea-surface temperature and sea-ice, daily volcanic and biomass burning emissions, as well as high-resolution inventories of anthropogenic sources. A description of the GEOS-5 model configuration used for this simulation can be found in Putman et al. (2014). The simulation is performed at a horizontal resolution of 7 km using a cubed-sphere horizontal grid with 72 vertical levels, extending up to to 0.01 hPa (approximately 80 km). For user convenience, all data products are generated on two logically rectangular longitude-latitude grids: a full-resolution 0.0625 deg grid that approximately matches the native cubed-sphere resolution, and another 0.5 deg reduced-resolution grid. The majority of the full-resolution data products are instantaneous with some fields being time-averaged. The reduced-resolution datasets are mostly time-averaged, with some fields being instantaneous. Hourly data intervals are used for the reduced-resolution datasets, while 30-minute intervals are used for the full-resolution products. All full-resolution output is on the model's native 72-layer hybrid sigma-pressure vertical grid, while the reduced-resolution output is given on native vertical levels and on 48 pressure surfaces extending up to 0.02 hPa. Section 4 presents additional details on horizontal and vertical grids. Information of the model surface representation can be found in Appendix B. The GEOS-5 product is organized into file collections that are described in detail in Appendix C. Additional details about variables listed in this file specification can be found in a separate document, the GEOS-5 File Specification Variable Definition Glossary. Documentation about the current access methods for products described in this document can be found on the GEOS-5 Nature Run portal: http://gmao.gsfc.nasa.gov/projects/G5NR. Information on the scientific quality of this simulation will appear in a forthcoming NASA Technical Report Series on Global Modeling and Data Assimilation to be available from http://gmao.gsfc.nasa.gov/pubs/tm/.

GEOS-5↗

Phase transitions of β-ZnTe(en) 0.5 under hydrostatic pressure

Organic–inorganic hybrid semiconductors have enhanced and distinctive material properties. β-ZnTe(en) 0.5 , which consists of alternating layers of two-monolayer-thick zinc telluride (ZnTe) and ethylenediamine (en), exhibits high crystallinity, stability, and tunable optical properties. Using x-ray diffraction (XRD) and Fourier transform infrared spectroscopy, this study investigated the structural response of β-ZnTe(en) 0.5 to applied hydrostatic pressure. Pressure-induced phase transitions were observed at 2.1 and 3.3 GPa. Shifts in the XRD peaks indicate substantial anisotropy in the pressure response, with the layer stacking direction ( b axis) exhibiting high compressibility. The a and b lattice parameters showed −0.55% strain/GPa and −2.26% strain/GPa, respectively, contradicting theoretical calculations that predicted a more isotropic response. IR spectroscopy revealed abrupt changes in NH 2 and CH 2 vibrational modes corresponding to the phase transitions.

Chemical compounds↗

INSTABILITY ANALYSIS OF CYLINDRICAL SHELLS UNDER HYDROSTATIC PRESSURE

To determine the elastic buckling pressure of simply supported cylindrical shells subjected to lateral end axial hydrostatic forces, various versions of linear bending theories have been employed in the past. For certain shell dimensions, however the expressions commonly used may yield substantially differing results. In what follows, recent work on this problem by A. E. Armenakas and the writer is briefly reviewed. This work consisted primarily in employing a general bending theory of circular cylindrical shells under the influence of initial stress, developed earlier by the same authors, to re-examine the problem mentioned, and compare the results with those of previous investigations. The outcome was the establishment of a simple but accurate expression for the buckling pressure applicable to a wide range of shell dimensions.

CYLINDRICAL SHELL↗

Inline small-angle X-ray scattering-coupled chromatography under extreme hydrostatic pressure

As continuing discoveries highlight the surprising abundance and resilience of deep ocean and subsurface microbial life, the effects of extreme hydrostatic pressure on biological structure and function have attracted renewed interest. Biological small-angle X-ray scattering (BioSAXS) is a widely used method of obtaining structural information from biomolecules in solution under a wide range of solution conditions. Due to its ability to reduce radiation damage, remove aggregates, and separate monodisperse components from complex mixtures, size-exclusion chromatography-coupled SAXS (SEC-SAXS) is now the dominant form of BioSAXS at many synchrotron beamlines. While BioSAXS can currently be performed with some difficulty under pressure with non-flowing samples, it has not been clear how, or even if, continuously flowing SEC-SAXS, with its fragile media-packed columns, might work in an extreme high-pressure environment. Here we show, for the first time, that reproducible chromatographic separations coupled directly to high-pressure BioSAXS can be achieved at pressures up to at least 100 MPa and that pressure-induced changes in folding and oligomeric state and other properties can be observed. Further, the apparatus described here functions at a range of temperatures (0°C–50°C), expanding opportunities for understanding biomolecular rules of life in deep ocean and subsurface environments.

59 BASIC BIOLOGICAL SCIENCES↗

Ground state of Ce 3 Bi 4 Pd 3 unraveled by hydrostatic pressure

Noncentrosymmetric Ce 3 Bi 4 Pd 3 has attracted a lot of attention as a candidate for strongly correlated topological material, yet its experimental ground state remains a matter of contention. Two conflicting scenarios have emerged from a comparison to the prototypical Kondo insulator Ce 3 Bi 4 Pd 3 : Either Ce 3 Bi 4 Pd 3 is a spin-orbit-driven topological semimetal or a Kondo insulator with smaller Kondo coupling than its Pt counterpart. Here, we determine the ground state of Ce 3 Bi 4 Pd 3 via electrical resistivity measurements under hydrostatic pressure, which is a clean symmetry-preserving tuning parameter that increases hybridization but virtually preserves spin-orbit coupling. Ce 3 Bi 4 Pd 3 becomes more insulating under pressures up to 2.3 GPa, which is a signature of Ce-based Kondo insulating materials in the considered pressure range. Its small zero-pressure gap increases quadratically with pressure, similar to the behavior observed in the series Ce 3 Bi 4 (Pt 1 - x Pd x ) 3 , which indicates that Pt substitution and applied pressure have a similar effect. Finally, our result not only demonstrates that Kondo coupling, rather than spin-orbit coupling, is the main tuning parameter in this class of materials, but it also establishes that Ce 3 Bi 4 Pd 3 has a narrow-gap Kondo insulating ground state.

36 MATERIALS SCIENCE↗