Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hydrogen fueling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An exploratory study to determine the integrated technological air transportation system ground requirements of liquid-hydrogen-fueled subsonic, long-haul civil air transports

An exploratory study was conducted to evaluate the feasibility and cost impact of implementing a liquid-hydrogen-fueled (LHz), air transport support system at Chicago-O’Hare International Airport. The study assumed an available supply of hydrogen to the airport boundary. It also assumed that the present widebody fleet at O’Hare was replaced by 400 passenger, LH2-fueled aircraft operating on the current frequency schedule and route network. The LH2 aircraft configurations used in this study were developed during a previous NASA-sponsored study. A baseline air terminal concept was developed which permitted airlines and the airport to operate JP- or LH2-fueled aircraft at common terminal gates. The concept included installation of a hydrogen liquefaction and storage facility on airport property, as well as the fuel distribution system. The capital investment and hydrogen-related operating costs to the airlines were estimated. The study concluded that the system would be technically and operationally feasible at O’Hare, and that economics would be a prime factor in future decisions regarding the use of LH2 as an air transport fuel. Research and technology recommendations were made to improve component efficiency/reliability. The study also concluded that additional investigation should be conducted on the implementation of a nationwide or worldwide LH2 air transportation system, to understand fully the operational and economic implications of the total system, before decisions could be made relative to committing to this option.

Hydrogen↗

Design of a miniature hydrogen fueled gas turbine engine

The design, development, and delivery of a miniature hydrogen-fueled gas turbine engine are discussed. The engine was to be sized to approximate a scaled-down lift engine such as the teledyne CAE model 376. As a result, the engine design emerged as a 445N(100 lb.)-thrust engine flowing 0.86 kg (1.9 lbs.) air/sec. A 4-stage compressor was designed at a 4.0 to 1 pressure ratio for the above conditions. The compressor tip diameter was 9.14 cm (3.60 in.). To improve overall engine performance, another compressor with a 4.75 to 1 pressure ratio at the same tip diameter was designed. A matching turbine for each compressor was also designed. The turbine tip diameter was 10.16 cm (4.0 in.). A combustion chamber was designed, built, and tested for this engine. A preliminary design of the mechanical rotating parts also was completed and is discussed. Three exhaust nozzle designs are presented.

Burnett, M.↗

Preliminary performance appraisal of Navy V/STOL transport and search-type airplanes using hydrogen fuel

First-cut estimates are given of the performance advantages of liquid-hydrogen-fueled, ejector wing, V/STOL aircraft designed for shipboard delivery and search-type missions. Results indicate that the use of LH2 could reduce gross weights 30 percent, empty weights 15 percent, and energy consumption 10 percent for a fixed payload and mission. If gross weight is fixed, the delivery range could be increased about 60 percent or the hover time during a search mission doubled. No analysis or discussion of the economic and operational disadvantages is presented.

Strack, W. C.↗

Dispenser Reliability: Materials R&D. A Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Report

Dispensers are the top cause of maintenance events and down-time at hydrogen fueling stations. In an effort to help characterize and enable improvements in dispenser reliability, an extensive accelerated lifetime testing set-up was designed and built at NREL involving components typically part of dispensing operations at fueling stations. Device Under Test (DUTs) included different components such as normally open valves, normally closed valves, fueling nozzles, breakaways devices and filters. Conditions of testing included pressures, and flow rates similar to light duty fuel cell electric vehicles fueling at -40°C, and -20°C for thousands of cycles in hydrogen. Tested components (failed and non-failed) were disassembled at SNL and polymeric O-rings were carefully retrieved and cataloged for chemical and physical characterization. Data collected was compared to similar O-rings from unexposed or non-tested components for hydrogen effects, and failure modes. Degradation analyses, based on select polymer chemistries common across all component types, their location within components, visual assessment of damage coupled with strong hydrogen effects from chemical characterization, was completed and presented to NREL and DOE. Overall, the failure rate amongst the components was not as high as expected for the test conditions. Among the component types tested, breakaways were the most susceptible to damage under these test conditions, with fueling nozzles a close second. The proper combination of selection of the right polymer and optimum component design was found to make a strong difference in component reliability under severe dispenser operating conditions. Physical degradation of polymers, rather than chemical changes due to low temperature hydrogen exposure, is more prevalent as failure mode for these test conditions. The nature and the extent of the degradation was much less at -20°C as compared to -40°C. The damage and failure rates were higher at lower temperatures than at higher test temperatures. As expected, increasing the number of cycles at the lowest test temperature (-40°C) increased damage. This indicates that cycling at the low temperature of -40°C required by SAE J2601 can reduce component life in fuel dispensing operations

08 HYDROGEN↗

Modeling Freight Traffic Demand and Highway Networks for Hydrogen Fueling Station Planning: A Case Study of U.S. Interstate 75 Corridor

The use of hydrogen as an alternative transportation fuel has gained much interest in recent years. Hydrogen can be utilized in electric vehicles equipped with hydrogen powertrains (including hydrogen internal combustion engines or fuel cells). Given that most of the freight in the U.S. is transported via diesel trucks, transition to hydrogen fuel would help achieve significant environmental benefits as well as accelerate the decarbonization of the freight transportation sector. This paper presents the methodology and results of a case study on modeling freight traffic demand and highway networks based on publicly available data for the Interstate 75 freight corridor. The purpose of this study is to prepare input traffic and network data that can support the planning of a hydrogen fueling station infrastructure. In particular, the data can be used for siting and characterizing an optimized framework of hydrogen fueling stations from candidate diesel stations along the Interstate 75 corridor. The methodologies developed and presented in this paper may be readily expanded and applied to any transport corridor given the data availability. This paper is the first in a series that will build out a comprehensive model to optimize a consolidated national hydrogen refueling infrastructure eco-system targeted at commercial vehicles.

Uddin, Majbah↗

Hydrogen-fueled scramjets: Potential for detailed combustor analysis

Combustion research related to hypersonic scramjet (supersonic combustion ramjet) propulsion is discussed from the analytical point of view. Because the fuel is gaseous hydrogen, mixing is single phase and the chemical kinetics are well known; therefore, the potential for analysis is good relative to hydro-carbon fueled engines. Recent progress in applying two and three dimensional analytical techniques to mixing and reacting flows indicates cause for optimism, and identifies several areas for continuing effort.

Beach, H. L., Jr.↗

Hydrogen-fueled diesel engine without timed ignition

Experiments were carried out to investigate the feasibility of converting a diesel engine to hydrogen-fueled operation without providing a timed ignition system. Use was made of a glow plug and a multiple-strike spark plug. The glow plug was found to provide reliable ignition and smooth engine operation. It caused the hydrogen to ignite almost immediately upon the start of injection. Indicated mean effective pressures were on the order of 1.3 MPa for equivalence ratios between 0.1 and 0.4 at a compression ratio of 18. This is significantly higher than the corresponding result obtained with diesel oil (about 0.6 MPa for equivalence ratios between 0.3 and 0.9). Indicated thermal efficiencies were on the order of 0.4 for hydrogen and 0.20-0.25 for diesel oil. Operation with the multiple-strike spark system yielded similar values for IMEP and efficiency, but gave rise to large cycle-to-cycle variations in the delay between the beginning of injection and ignition. Large ignition delays were associated with large amplitude pressure waves in the combustion chamber. The measured NO(x) concentrations in the exhaust gas were of the order of 50-100 ppm. This is significantly higher than the corresponding results obtained with premixed hydrogen and air at low equivalence ratios. Compression ignition could not be achieved even at a compression ratio of 29.

Homan, H. S.↗

Effect of Reynolds number variation on aerodynamics of a hydrogen-fueled transport concept at Mach 6

Two separate tests have been made on the same blended wing-body hydrogen-fueled transport model at a Mach number of about 6 and a range of Reynolds number (based on theoretical body length) of 1.577 to 55.36 X 10 to the 6th power. The results of these tests, made in a conventional hypersonic blowdown tunnel and a hypersonic shock tunnel, are presented through a range of angle of attack from -1 to 8 deg, with an extended study at a constant angle of attack of 3 deg. The model boundary layer flow appeared to be predominately turbulent except for the low Reynolds number shock tunnel tests. Model wall temperatures varied considerably; the blowdown tunnel varied from about 255 F to 340 F, whereas the shock tunnel had a constant 70 F model wall temperature. The experimental normal-force coefficients were essentially independent of Reynolds number. A current theoretical computer program was used to study the effect of Reynolds number. Theoretical predictions of normal-force coefficients were good, particularly at anticipated cruise angles of attack, that is 2 to 5 deg. Axial-force coefficients were generally underestimated for the turbulent skin friction conditions, and pitching-moment coefficients could not be predicted reliably.

Penland, Jim A.↗

Development and validation of purged thermal protection systems for liquid hydrogen fuel tanks of hypersonic vehicles

An economical, lightweight, safe, efficient, reliable, and reusable insulation system was developed for hypersonic cruise vehicle hydrogen fuel tanks. Results indicate that, a nitrogen purged, layered insulation system with nonpermeable closed-cell insulation next to the cryogenic tank and a high service temperature fibrous insulation surrounding it, is potentially an attractive solution to the insulation problem. For the postulated hypersonic flight the average unit weight of the purged insulation system (including insulation, condensate and fuel boil off) is 6.31 kg/sq m (1.29 psf). Limited cyclic tests of large specimens of closed cell polymethacrylimide foam indicate it will withstand the expected thermal cycle.

Helenbrook, R. D.↗

Performance of a short combustor at high altitudes using hydrogen fuel

Performance characteristics of a 16-inch annular-type combustor installed in a full-scale engine using gaseous-hydrogen fuel were obtained at simulated altitudes from 66,000 to 86,000 feet at a flight Mach number of 0.8. Combustion efficiencies of 86 percent were obtained at 86,000 feet (combustor pressure, 420 lb/sq ft abs). Combustor blowout was not encountered during the investigation.

Sivo, Joseph N↗

Heavy-Duty Hydrogen Fueling Station Corridors

In this short technical report, we explore the range of levelized costs of dispensed hydrogen (H2) from hydrogen refueling (or fueling) stations (HRS) for H2 heavy-duty fuel cell electric vehicles (FCEVs) that are feasible in the 2030 timeframe. We explore different scenarios by varying hydrogen delivery distances, HRS sizes, HRS utilization rates, and economies of scale in the Hydrogen Delivery Scenario Analysis Model (HDSAM). Thus, we observe how the contribution to the levelized cost of each supply chain component changes.

DIRECT ENERGY CONVERSION,HYDROGEN↗

A new high strength alloy for hydrogen fueled propulsion systems

This paper describes the development of a high-strength alloy (1241 MPa ultimate and 1103 MPa yield, with little or no degradation in hydrogen) for application in advanced hydrogen-fueled rocket engines. Various compositions of the Fe-Ni-Co-Cr system with elemental additions of Cb, Ti and Al are discussed. After processing, notched tensile specimens were tested in 34.5-MPa hydrogen at room temperature, as the main screening test. The H2/air notch tensile ratio was used as the selection/rejection criterion. The most promising alloys are discussed.

Mcpherson, W. B.↗

Wall-temperature effects on the aerodynamics of a hydrogen-fueled transport concept in Mach 8 blowdown and shock tunnels

Results are presented from two separate tests on the same blended wing-body hydrogen fueled transport model at a Mach number of about 8 and a range of Reynolds numbers (based on theoretical body length) of 0.597 x 10 to the 6th power to about 156.22 x 10 to the 6th power. Tests were made in conventional hypersonic blowdown tunnel and a hypersonic shock tunnel at angles of attack of -2 deg to about 8 deg, with an extensive study made at a constant angle of attack of 3 deg. The model boundary-layer flow varied from laminar at the lower Reynolds numbers to predominantly turbulent at the higher Reynolds numbers. Model wall temperatures and stream static temperatures varied widely between the two tests, particularly at the lower Reynolds numbers. These temperature differences resulted in marked variations of the axial-force coefficients between the two tests, due in part to the effects of induced pressure and viscous interaction variations. The normal-force coefficient was essentially independent of Reynolds number. Analysis of results utilized current theoretical computer programs and basic boundary-layer theory.

Penland, J. A.↗

Parametric study of ascent performance of a vertically launched hydrogen-fueled single-stage reusable transport

Ascent performance characteristics were studied for a vertical-take-off, horizontal-landing, single-stage-to-orbit transport vehicle powered by hydrogen fuel rocket with a mixture of fixed- and dual-position nozzles. The analysis was made by systematically varying two sets of trajectory similarity parameters based on the propulsive and aerodynamic characteristics of the vehicle and by calculating a trajectory for each combination of the parameters. The propulsion parameters were the initial thrust-weight ratio, engine combination, and the two expansion ratios of the dual-position rocket nozzles. The aerodynamic parameters were the ratio of reference area to initial weight and the ratio of maximum allowable normal force to initial weight. A first-order analysis was carried out to determine the effect on the performance of including the engine mass penalty. This analysis indicates that the configuration with the lowest initial mass for a given payload requires all dual-position nozzles with initial expansion ratio of 50 and a final expansion ratio of 150.

Rehder, J. J.↗