Analyzing Gas Turbine-Generator Performance of the Hybrid Power System

We report kinetic energy available from the turbomachinery may boost short-term ramp rates during load shifting between generator and fuel cell that may be exploited to optimize the performance of turbine-fuel cell hybrid systems during load following. The paper starts with modeling a gas turbine, gearbox, and generator sitting on the rigid shafts as a two-mass model primarily for estimating the rotational inertia available from the turbogenerator. The gas turbine and its environment impose constraints of available space allowances, measurements from high-speed rotating parts, lack of accessibility to the shaft of measure, making replacements and/or required installation adjustments of the torque transducer difficult. It is demonstrated that in the absence of torque measurement, the data containing only a slow excursion of the rotor motion in response to a slight load change is sufficient to determine inertia and damping coefficients from the model. Furthermore, the generator’s reactive power capability was investigated because it serves as an asset in integrated hybrid systems to meet dynamic reactive power demands, reducing the burden on the fuel cell’s power electronics control in generating reactive power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid power semiconductor

The voltage rating of a bipolar transistor may be greatly extended while at the same time reducing its switching time by operating it in conjunction with FETs in a hybrid circuit. One FET is used to drive the bipolar transistor while the other FET is connected in series with the transistor and an inductive load. Both FETs are turned on or off by a single drive signal of load power, the second FET upon ceasing conductions, rendering one power electrode of the bipolar transistor open. Means are provided to dissipate currents which flow after the bipolar transistor is rendered nonconducting.

Chen, D. Y.↗

The physics basis to integrate an MHD stable, high-power hybrid scenario to a cool divertor for steady-state reactor operation

Abstract Coupling a high-performance core to a low heat flux divertor is a crucial step for ITER and a Fusion Pilot Plant or DEMO. Experiments in DIII-D recently expanded the steady-state hybrid scenario to high density and divertor impurity injection to study the feasibility of a radiating mantle solution. This work presents the physics basis for trade-offs between density, current drive and stability to tearing modes (TMs) at high β. EC power is crucial to tailor the plasma profiles into a passively stable state, and to eject impurities from the core. Off-axis EC depositions decrease the heating efficiency, but calculated electron heat transport coefficients show that this effect is partially mitigated by improved confinement inside the EC deposition. Additionally, the reduction in pressure is recovered by increasing the density. This favourable scaling of confinement with density was observed in high power plasmas for years, and this work provides a comprehensive explanation. ELITE predictions indicate that a path in peeling-ballooning stability opens up for certain conditions of density, power, q 95 and shaping, allowing the edge pressure to continue increasing without encountering a limit. In the core, calculated anomalous fast-ion diffusion coefficients are consistent with density fluctuation measurements in the toroidicity-induced Alfvén eigenmode range, showing that smaller fast-ion losses contribute to the enhanced confinement at high density. The edge integration study shows that divertor heat loads can be reduced with Ne and Ar injection, but this eventually triggers a cascade of n = 1, 2, 3 core TMs. We can now show that impurity radiation in the core is small and it is not the cause for the drop in confinement at high Ar and Ne injection rates. The overlap between the core TMs is consistent with the loss of pressure as estimated by the Belt model for the coupled rational surfaces. Optimization of these trade-offs has achieved plasmas with sustained H 98y2 = 1.7, f GW = 0.7 and ∼85% mantle radiation. The scenario and its variations at higher density and on- vs off-axis EC heating has been studied as a candidate for an integrated solution for several reactor designs, such as ITER, ARC, and the ARIES-ACT1 case, showing promising results in terms of fusion power and gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding Economic and Deployment Benefits of Wind-PV Hybrid Power Plants

The least-cost approach to decarbonizing the U.S. electricity supply will likely involve a significantly expanded share of variable renewable energy (VRE) generation. Many strategies and approaches have been identified to address integration challenges in a VRE-dominated system, including standalone and coupled battery systems. In this study, we explored the current and future potential of utility-scale hybrid energy systems comprising PV, wind, and lithium-ion battery technologies (PV-wind-battery systems). Analysis results include temporal complementarity of wind and PV resources across the contiguous United States, with an emphasis on metrics that quantify reductions in variability that can be achieved through hybridization. We further use a price-taker model with simulated hourly energy and capacity prices to determine the revenue-maximizing dispatch of a range of PV-wind-battery configurations across Texas, from the present through 2050. We find that coupling PV, wind, and battery technologies allows for more effective utilization of interconnection capacity by increasing capacity factors to 60-80%+ and capacity credits to close to 100%, depending on battery capacity. We also compared the energy and capacity values of PV-wind and PV-wind-battery systems to the corresponding stability coefficient metric, which describes the location-and configuration-specific complementarity of PV and wind resources. Our results show that the stability coefficient effectively predicts the configuration-location combinations in which a smaller battery component can provide comparable economic performance in a PV-wind-battery system (compared to a PV-battery system). These PV-wind-battery hybrids can help integrate more VRE by providing smoother, more predictable generation and greater flexibility. Finally, capacity expansion modeling of PV-wind systems indicates that hybridization can reduce transmission expansion requirements associated with a heavily decarbonized U.S. electricity system.

complementarity↗

Hybrid Power Purchase Agreements for Flexible 24/7 Energy Delivery – A Comprehensive Review of Current Practices and Research Pathways

Power Purchase Agreements (PPAs) are becoming increasingly preferred among large energy consumers, such as data centers, to secure cost-effective energy and meet accelerating demand growth. Traditionally, variable renewable energy (VRE)-based PPAs operate on a pay-as-produced basis, balancing supply and demand for a relatively longer duration (e.g., annually). However, the focus is shifting toward matching supply and demand on an hourly basis to fully meet energy needs. This shift requires the integration of flexible energy resources, such as hydropower, thermal generation, and energy storage, to complement VRE sources like wind and solar, forming the foundation for 24/7 PPA. This work contributes by: (i) reviewing emerging market trends and current practices in PPA procurement, supported by data on PPA prices and technology portfolios; (ii) synthesizing the existing literature on modeling approaches for contract pricing, quantities, hybrid resource procurement, and risk management in 24/7 PPA design, while identifying key research gaps; and (iii) proposing an integrated 24/7 PPA design framework along with two contracting mechanisms from the perspectives of both PPA providers and consumers. The proposed framework highlights critical modeling challenges, risk-allocation issues, and future research opportunities for 24/7 PPA design.

24/7↗

A reduced order sulfuric acid decomposition model for a nuclear-powered hybrid sulfur cycle

A reduced order model of sulfuric acid decomposition within a bayonet chemical reactor was developed to support the U. S. Department of Energy Integrated Energy System program, and address the lack of knowledge in scaling and integration for joint chemical and nuclear processes. Sulfuric acid decomposition within a bayonet reactor was modeled to provide chemical and thermodynamic data relevant to advanced nuclear reactor-driven integrated energy systems based on desired operational scale and operational conditions. The temperature range required for high-temperature advanced nuclear reactor integrated energy systems, 750-850 °C, was shown to produce reasonable agreement (within a few percent relative error) with past models and experimental data, and yielded good efficiency results for bayonet reactor operations. The results of the reduced order model agreed with previous work from Savannah River National Labs within a maximum of 3.4% error on the decomposition of sulfur trioxide, and on previous Hybrid Sulfur flowsheets from Gorensek and Summers that showed operational temperature, pressure, and composition ranges for efficiency which made the Hybrid Sulfur cycle competitive with water electrolysis. Here, the agreement with previous high-fidelity models provided a framework for future Integrated Energy System grid evaluations with an advanced nuclear reactor and large-scale hydrogen production using a mathematical model to represent chemical operations.

08 HYDROGEN↗

Deployable Wind-Hybrid Power Systems for Defense and Disaster Response Applications

This report presents an analysis of the performance of deployable energy systems comprised of wind energy systems integrated with diesel generators, photovoltaic systems, and battery storage to meet the load requirements of a representative U.S. Army forward operating base. The analysis is conducted using HOMER, a microgrid analysis software that can search through a wide range of parameters to design and optimize microgrid power systems. The search parameters include the system architecture, the wind and solar resources, and the availability of diesel fuel. The results of the analysis measure the relative performance of the different systems and environments in terms of the overall transportation cost to deploy the system and the ability to provide resilience in terms of meeting mission critical loads.

02 PETROLEUM↗

Computational Evaluation of Inlet Distortion on an Ejector Powered Hybrid Wing Body at Takeoff and Landing Conditions

Due to the aft, upper surface engine location on the Hybrid Wing Body (HWB) planform, there is potential to shed vorticity and separated wakes into the engine when the vehicle is operated at off-design conditions and corners of the envelope required for engine and airplane certification. CFD simulations were performed of the full-scale reference propulsion system, operating at a range of inlet flow rates, flight speeds, altitudes, angles of attack, and angles of sideslip to identify the conditions which produce the largest distortion and lowest pressure recovery. Pretest CFD was performed by NASA and Boeing, using multiple CFD codes, with various turbulence models. These data were used to make decisions regarding model integration, characterize inlet flow distortion patterns, and help define the wind tunnel test matrix. CFD was also performed post-test; when compared with test data, it was possible to make comparisons between measured model-scale and predicted full-scale distortion levels. This paper summarizes these CFD analyses.

Wind Tunnel Testing↗

Experimental Evaluation of Inlet Distortion on an Ejector Powered Hybrid Wing Body at Take-off and Landing Conditions

As part of the NASA Environmentally Responsible Aircraft project, an ultra high bypass ratio engine integration on a hybrid wing body demonstration was planned. The goal was to include engine and airframe integration concepts that reduced fuel consumption by at least 50% while still reducing noise 42 db cumulative on the ground. Since the engines would be mounted on the upper surface of the aft body of the aircraft, the inlets may be susceptible to vortex ingestion from the wing leading edge at high angles of attack and sideslip, and separated wing/body flow. Consequently, experimental and computational studies were conducted to collect flow surveys useful for characterizing engine operability. The wind tunnel tests were conducted at two NASA facilities, the 14- by 22-foot at NASA Langley and the 40- by 80-foot at NASA Ames Research Center. The test results included in this paper show that the distortion and pressure recovery levels were acceptable for engine operability. The CFD studies conducted to compare to experimental data showed excellent agreement for the angle of attacks examined, although failed to match the low speed experimental data at high sideslip angles.

Carter, Melissa B.↗

Hydrogen Enrichment for Solid Oxide Fuel Cell Gas Turbine (SOFC/GT) Hybrid Power Generation Systems Using Mechanical Gas Separation

This presentation, given at the 37 th annual Pittsburgh Coal Conference on September 8-11, 2020, includes information on the process, previous work, normal and oblique shocks model, diffuser design model, and calculation results (expansion, recompression with no losses, and recompression with mass depletion). Summary includes the concept of aerodynamic separation of water and carbon dioxide from a SYNGAS stream and that deposition was modeled by mass depletion from a compressible flow.

VanOsdol, John↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

According to the U.S. Department of Energy Combined Heat and Power Installation Database, approximately 80 GW of electrical power is produced in the United States using combined heat and power (CHP) systems. Studies have also shown that a potential market for CHP applications is larger than the existing market. Since fuel consumption is the most significant part of the operating cost for a CHP plant, higher efficiency translates to increased power output for the same quantity of fuel.

CHHP, LHV, CHP↗

Waste heat recovery hybrid power drive

A vehicle system includes an engine, a transmission, a differential, and a waste heat recovery (WHR) drive that converts thermal energy into mechanical and electrical energy. The WHR drive can include a WHR power unit structured to convert thermal energy into rotation of a WHR drive shaft. A motor/generator having a motor/generator shaft can selectively operate as a motor or a generator. A mechanical linkage is structured to selectively link an output shaft to one of the WHR drive shaft and the motor/generator drive shaft independently of the other of the WHR drive shaft and the motor/generator drive shaft. The output shaft is selectively coupled to one of the engine, the transmission, or the differential. The vehicle system may also include a traction motor to provide drive to the vehicle. The output shaft can be selectively coupled to the traction motor or the engine.

Narula, Manik↗

A comparison of GaAs and Si hybrid solar power systems

Five different hybrid solar power systems using silicon solar cells to produce thermal and electric power are modeled and compared with a hybrid system using a GaAs cell. Among the indices determined are capital cost per unit electric power plus mechanical power, annual cost per unit electric energy, and annual cost per unit electric plus mechanical work. Current costs are taken to be $35,000/sq m for GaAs cells with an efficiency of 15% and $1000/sq m for Si cells with an efficiency of 10%. It is shown that hybrid systems can be competitive with existing methods of practical energy conversion. Limiting values for annual costs of Si and GaAs cells are calculated to be 10.3 cents/kWh and 6.8 cents/kWh, respectively. Results for both systems indicate that for a given flow rate there is an optimal operating condition for minimum cost photovoltaic output. For Si cell costs of $50/sq m optimal performance can be achieved at concentrations of about 10; for GaAs cells costing 1000/sq m, optimal performance can be obtained at concentrations of around 100. High concentration hybrid systems offer a distinct cost advantage over flat systems.

Heinbockel, J. H.↗

Dynamic optimization and economic evaluation of flexible heat integration in a hybrid concentrated solar power plant

Hybridization of concentrated solar power (CSP) plants provides flexibility in operation that can drastically improve the solar-to-electric (STE) efficiency and levelized cost of electricity (LCOE) relative to standalone CSP plants. Flexible heat integration (FHI) is a novel concept where the collection and integration of CSP within a power plant is modified relative to the amount of solar energy available. FHI improves the thermal efficiency of a hybrid solar tower steam Rankine cycle power plant but leads to increased pumping needs due to continuously elevated molten salt flow rates through the collection system, which can negatively impact STE efficiency. The present work is carried out to maximize the STE efficiency of a hybrid CSP plant utilizing FHI by employing a dynamic optimization framework where a genetic algorithm optimizes the operation of the plant over a given solar irradiance profile. The study concerns a plant hypothetically located in Salt Lake City, Utah. Here, the optimization results confirm the accuracy of a predictive heuristic where the preferred operation of the plant can be estimated relative to local peaks in the incident power generated by the heliostat collection field. The optimized FHI operation demonstrates a yearly STE efficiency of 13.8%, whereas the equivalent base-level hybrid and solar-only plants exhibit solar efficiencies of 13.4% and 11.2%, respectively. Economic analysis shows that FHI reduces yearly natural gas costs, leading to a $\$0.5$/MWh reduction in LCOE relative to the base-level hybrid configuration. Overall, the results show that hybrid FHI schemes exhibit economic benefits along with observed thermodynamic improvements.

14 SOLAR ENERGY↗

Control of energy storage to reduce electric power system off-nominal frequency deviations

A hybrid power generation system is formed by the combination of an energy storage system (ESS) and a rotating synchronous power generator (SPG). Energy is stored in or released from the ESS in response to measurements of the at least one angle parameter, selected from rotor, torque, or power angle of the SPG, to provide active frequency damping of electrical power output. The control of ESS energy exchange increases the stabilizing impact of the SPG inertia on the frequency of electricity in an electrical network or power grid. The hybrid power generation system can have an effective equal area criterion for stability limit that is greater than that of the SPG operating without the ESS. The hybrid power generation system can enable the electrical network to have a greater proportion of variable or distributed energy resource (DER) power generation systems without otherwise exceeding stability limits.

Vartanian, Charles K.↗