Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human-systems interface”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

60 records · Page 4

Variable Vector Countermeasure Suit (V2Suit) for Space Habitation and Exploration

The "Variable Vector Countermeasure Suit (V2Suit) for Space Habitation and Exploration" is a visionary system concept that will revolutionize space missions by providing a platform for integrating sensors and actuators with daily astronaut intravehicular activities to improve human health and performance. The V2Suit uses control moment gyroscopes (CMGs) within a miniaturized module placed on body segments to provide a "viscous resistance" during movements and a countermeasure to the sensorimotor and musculoskeletal adaptation performance decrements that manifest themselves while living and working in microgravity and during gravitational transitions during long-duration spaceflight, including post-flight recovery and rehabilitation. Through an integrated design, system initialization, and control systems approach the V2Suit is capable of generating this "viscous resistance" along an arbitrarily specified direction of "down." When movements are made, for example, parallel to that "down" direction a resistance is applied, and when the movement is perpendicular to that direction no resistance is applied. The V2Suit proposes to be a countermeasure to this spaceflight-related adaptation and de-conditioning and the unique sensorimotor characteristics associated with living and working in 0-G, which are critical for future long-duration space missions.This NIAC Phase I project focused on detailing several aspects of the V2Suit concept, including human-system integration, system architecture, computer aided design (CAD) modeling, and closed-loop simulation and analysis. In addition, early-stage breadboard prototyping of several aspects of the V2Suit system modules enabled characterization of expected performance and identified areas for further research and development to enable operational implementation of the V2Suit. In particular, potential challenges with integration of commercial-off-the-shelf components were identified. The key enabler for operational use and adoption of the V2Suit is a low-profile body worn form factor that does not interfere with normal, everyday movements and interfaces adequately with the body as to provide the generated gyroscopic torque for the perceptions of movement with a "viscous resistance." These aspects were investigated through mockups using a life-size mannequin, and through body attachment mechanisms on the breadboard prototype. Through the evaluation and investigation of commercially-available components, as well as an identification of desirable form factors, CAD models of the V2Suit modules were developed. These models included all of the required elements and spin motors, flywheel masses, gimbal motors, slip rings, inertial measurement units, motor controllers, and the required mounting brackets/hardware and cabling. The configuration and orientation of the control moment gyroscopes (CMGs) was specified according to results from the modeling, simulation and analysis. Two revisions of the CAD model were investigated through closed-loop simulation of the CMGs, and their ability to generate a resultant reaction force during movement and null undesirable torques due to changes in the direction of the angular momentum vector as a result of the normal body movements.

space missions↗

Developing a Medical System Foundation for Level of Care IV: Short-Duration Lunar Orbit

The Human Research Program (HRP) Exploration Medical Capability (ExMC) element has developed a Medical System Foundation for Level of Care IV, as defined by NASA’s space flight human-system standards, for short-duration lunar orbit missions by employing a systems engineering approach using model-based systems engineering tools. This Foundation includes a concept of operations, medical system architecture, associated functional and non-functional requirements and rationales, and medical conditions, capabilities, and resources. Collectively, these serve as a starting point (“Foundation”) for a medical system that meets the Level of Care IV requirement. The Foundation also includes traces to the current versions of NASA standards documents and lower (e.g., sub-system) and higher (e.g., vehicle system) level requirements. Stakeholders can use the Foundation to analyze the traces between medical capabilities, medical conditions, medical resources, and requirements; identify medical system interfaces with other vehicle systems/subsystems; and as a basis for performing trades on risks vs. medical system mass and volume allocation. To facilitate communication of the Foundation to stakeholders who do not have access to the modeling tools used, an HTML representation of the Foundation was created. This discussion will focus on the processes through which the Medical System Foundation was developed, how the Foundation builds a bridge between the medical and engineering domains and facilitates communication between these communities, and how these processes can be applied more broadly to a crew health and performance system and other system domains.

S. Lumpkins↗

Medical System Foundation Overview for Long-Duration Lunar Orbit and Surface Operations Missions

The Human Research Program (HRP) Exploration Medical Capability (ExMC) Element has developed a Medical System Foundation for Level of Care IV, as defined by NASA’s space flight human-system standards, for long-duration lunar orbit and surface operation missions by employing a systems engineering approach using model-based systems engineering tools. This Foundation model includes a concept of operations; functional decomposition; clinical content (medical conditions, capabilities, and resources); associated functional, interface and non-functional technical requirements; and traces to the current versions of NASA standards documents and parent-level (Program- and Vehicle habitat system level) requirements. Collectively, these components constitute a foundation that serves as a starting point for a medical system that meets the Level of Care IV requirement. The Foundation was developed by a multidisciplinary team consisting of systems engineers, scientists, and clinicians across NASA, and information is presented in an easily accessible format that is understandable across disciplines. Stakeholders can use the Foundation to analyze the traces between medical capabilities, medical conditions, medical resources, and requirements and to identify medical system interfaces with other vehicle systems/subsystems. It can also be used as a basis for performing trades on risks vs. medical system mass and volume allocation. This discussion will focus on the processes through which the Medical System Foundation was developed, how the Foundation builds a bridge between the medical and engineering domains and facilitates communication between these communities, and how these processes can be applied more broadly to a crew health and performance system and other system domains. The presentation also discusses Foundation modifications based on the recently updated versions of the NASA 3001 Standards.

S. Lumpkins↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, and spinal elongation. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, measurement tools have not been available for accurate assessments of body shape changes. This work aimed to develop a prototype 3-D body scanning system with the configuration and performance optimized for in-flight crewmember body scanning. A scan hardware system was developed using Intel RealSense commercial off-the-shelf 3D sensors. The sensor parameters were iteratively optimized and tested to obtain the performance level needed for body scanning. A scan booth structure was fabricated, with the overall size 4 x 4 x 8 feet. The specific number of sensors and mounting positions were determined by iterative simulations, which indicated that 16 cameras can capture 94% and 96% of body surface area from the 1st percentile female and 99th percentile male crew population subject. The mounted sensors were linked through a mix of USB-C and USB-3 cables and operated for data acquisition from a Linux laptop computer. A software prototype was developed using Python and Tkinter graphical user interface toolkit. A calibration procedure was also built using a panel of QR codes. A computer vision tool detected and decoded the unique ID and pattern locations of the QR codes. The calibration information determined the position and orientation of the 3D sensors with respect to each other. The scanner performance was assessed using a set of 3D printed custom manikins. The manikin size and shape were derived from the previous ISS study, which measured the crewmembers’ anthropometry changes across the different flight phases. The average anthropometric measurements at the pre-flight and flight day 15 were sampled and projected onto the 1st percentile female and 99th percentile male body shapes. Another pair of manikins were also 3D printed to simulate the neutral body posture, estimated from ISS microgravity environments. A preliminary analysis assessed the performance of the newly developed scanner against the reference scanner, which has been used at the NASA JSC for crew and test subject anthropometry. Although the new scanner data showed several artifacts and missing geometries in the occluded body areas such as armpits and crotch, overall shape matched with the reference scan. When the manikin surface coordinates were compared, a root mean square error of 1.3 cm was observed from the manikin torso segment. Linear measurements including the stature, knee height and circumference measurements at the chest and calf showed differences from the reference scan measurements, ranging between 0.3 and 0.9 cm. Overall, this work demonstrated a development framework for an in-flight scanner with design and operation optimized for crewmember body scanning. Further improvement can potentially provide previously unavailable anthropometric data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗