Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hot wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Experimental comparison of two hot-wire techniques for resolution of turbulent mass flux and local stagnation temperature in supersonic flow

The performance of two constant-temperature normal hot-wire techniques in a supersonic flow is examined. The first technique uses a single-wire and rapid scanning of multiple overheat ratios. Time averages of the signals at all overheats are used to separate the mean and rms mass flux, stagnation temperature and their cross-correlation. The second technique uses a dual-wire probe with each wire operating at different overheat ratios, giving instantaneous mass flux and stagnation temperature. Preliminary results indicate that the separation distance (0.18 mm) between the two hot wires in the dual-wire probe does not introduce significant error. However, the rms mass flux inferred from the dual-wire technique is a factor of two higher than that from the single-wire technique.

Walker, D. A.↗

Turbulence measurements in a confined jet using a six-orientation hot-wire probe technique

The six-orientation hot-wire technique is applied to nonreacting axisymmetric flowfields, obtaining measurements of time-mean and rms voltages at six different orientations, thus providing enough information to determine the time-mean velocities, turbulence intensities, and shear stresses. At each location in the flow, there are six different values of each of the above quantities that can be obtained using six sets of measurements of three adjacent orientations. Flowfield surveys of both swirling and nonswirling confined jets are used to calculate estimates of the mean velocity components and the normal and shear turbulent stresses, and comparisons with independent data are made. A sensitivity analysis of the data reduction technique demonstrates that the largest uncertainties are to be expected in the turbulent shear force estimates.

Janjua, S. I.↗

The static response of a bowed inclined hot wire

The directional sensitivity of a bowed, inclined hot wire is investigated using a simple model for the convective heat transfer. The static response is analyzed for subsonic and supersonic flows. It is shown that the effects of both end conduction and wire bowing are greater in supersonic flow. Regardless of the Mach number, however, these two phenomena have distinctly different effects; end conduction appears to be responsible for reducing the nonlinearity of the response, whereas bowing increases the directional sensitivity. Comparison with the available data suggests that the analysis is useful for interpreting the experimental results.

Smits, A. J.↗

The use of hot-wire anemometry in transonic periodic flow

The unsteady wake profiles of an airfoil with an oscillating flap were measured in the NASA Ames 11 x 11-foot transonic wind tunnel. Laser Doppler Velocimetry (LDV) and holography techniques were used in limited region where optical accessability is available. X-hot-film wire was used to measure the wake profiles in the complete region to obtain magnitude and direction of the flow. A thorough calibration was carried out to determine the sensitivity coefficients of the hot-wire in three different tunnels at transonic speeds. A calculation procedure is established to resolve the hot-wire signals at transonic speeds and applied in the measurements of steady and periodic wake profiles. The effect of flow incidence on the hot-wire signals is evaluated and incorporated in the analyses. Typical hot-wire results are compared with the results of LDV, holography and pitot-static tube embedded with Kulite transducers.

Bodapati, S.↗

Hot wire in low Reynolds number flow

Progress reports were issued on the following experiments: (1) low Reynolds number flow phenomenon of periodic vortex shedding in the wake behind a cylinder as studied by applying the hot wire anemometer technique of flow measurement. The downstream diffusion of these shed vortices was of prime concern. An evaluation of the performance of the hot wire at low Reynolds number is also considered. (2) A brief examination of the back sections of the Wright Brothers wind tunnel circuits were conducted to establish whether or not gross flow deviations were present at corners, or turning vane regions. A calibration of the test sections was done. (3) The attractiveness of using rembedded grids for airfoil calculations modeled by the Euler equations was explored. These calculations were extended to C-type grids and then to Navier-Stokes calculations,

Kolb, M. A.↗

Oscillating hot-wire anemometer

Performance analysis was made of oscillating hot-wire anemometer electrical output in gas stream. Advantages include no calibration and measurement of fluid direction as well as fluid speed.

Conley, J. M.↗

Some influences of approximate values for velocity, density and total temperature sensitivities on hot wire anemometer results

There is a renewed interest in hot wire anemometry at transonic speeds. Recent results were published which indicate that at transonic speeds a heated wire is sensitive only to mass flow and total temperature, results similar to those obtained for supersonic flows. Other results were obtained to show that the sensitivity is a function of velocity, density, and total temperature, results in agreement with many of those obtained in the 1950s. An analysis of anemometry results was made to evaluate possible errors when various assumptions were made concerning the sensitivity of a heated wire to fluid flow variables.

Stainback, P. C.↗

Fabrication and testing of subminiature multi-sensor hot-wire probes

A method for the fabrication of hot-wire sensors measuring 0.6 micron in diameter and 200 microns in length is described. This method allows accurate control of sensing-element orientation, thus making it possible to produce multisensor probes. Test results obtained with a miniature sensor fabricated by this method, for the outer region of a turbulent boundary layer developing in a zero presure gradient were compared to measurements from a conventional-sized probe made in the same flow, demonstrating that, because of their improved spatial resolution, subminiature sensors can provide more accurate measurements in boundary layers than do the conventional probes.

Ligrani, P. M.↗

Hot-wire, laser anemometer and force balance measurements of cross-sectional planes of single and interacting trailing vortices

Single and multiple trailing vortices shed from semi-span wings and a transport model in a wind tunnel were studied by means of a laser-velocimeter, hot-wire anemometer, and a trailing model incorporating a 6-component force balance. Velocity profile and turbulence data from the laser-velocimeter and hot-wire anemometer are presented and shown to compare well with the Betz inviscid circulation model. Lift and rolling moment measurements on the following model are compared with those predicted from the flow field measurements.

Iversen, J. D.↗

Measurement of flow angle and mass flow rate in an unknown flow field using hot film and hot wire probes

A data reduction technique applicable to constant temperature hot film and hot wire probes is presented which is used to determine flow angle and mass flow rate in an unknown flow field over a wide range of flow conditions at supersonic and hypersonic velocities. The technique virtually eliminates the effect of Reynolds number on a probe's flow angle sensitivity. Methods for extrapolating a limited amount of mass flow rate calibration data to include the range of mass flow rate encountered in an experiment are also given. This technique has been applied to data obtained using a hot film probe during surveys in the leeside flow field of a space shuttle orbiter configuration.

Helms, V. T., III↗

Constant-temperature hot-wire anemometer practice in supersonic flows. I - The normal wire

The performance of a constant-temperature normal hot-wire in a supersonic flow is critically examined. It is shown that this instrument is inherently unsuitable for measuring turbulent temperature correlations because of the highly nonlinear response to temperature fluctuations, particularly at low overheat ratios. The instrument is therefore limited to measurements of mean and fluctuating mass-flow rates. Suitable calibration procedures, as well as the limits on spatial and temporal resolution are discussed, and corrections for mean stagnation temperature changes are suggested.

Smits, A. J.↗

Constant-temperature hot-wire anemometer practice in supersonic flows. II - The inclined wire

The performance of a constant-temperature inclined hot-wire in a supersonic flow is critically examined. It is shown that calibration techniques applicable to subsonic flow, such as the cosine cooling law cannot be used when the flow is supersonic. Calibration and measurement procedures appropriate to supersonic flow are suggested, together with the possible limits on their validity. Experimental results for different wires indicate that the sensitivities do not seem to depend on flow direction according to any simple correlation. When the sensitivity exhibits a strong dependence on flow direction, the wire should be discarded to avoid errors due to nonlinear effects.

Smits, A. J.↗

A high-performance constant-temperature hot-wire anemometer

A high-performance constant-temperature hot-wire anemometer has been designed based on a system theory analysis that can be extended to arbitrary order. A motivating factor behind the design was to achieve the highest possible frequency response while ensuring overall system stability. Based on these considerations, the design of the circuit and the selection of components is discussed in depth. Basic operating instructions are included in an operator's guide. The analysis is used to identify operating modes, observed in all anemometers, that are misleading in the sense that the operator can be deceived by interpreting an erroneous frequency response. Unlike other anemometers, this instrument provides front panel access to all the circuit parameters which affect system stability and frequency response. Instructions are given on how to identify and avoid these rather subtle and undesirable operating modes by appropriate adjustment of the controls. Details, such as fabrication drawings and a parts list, are provided to enable others to construct the instrument.

Watmuff, Jonathan H.↗