Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high wind penetration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Investigation of Farm-to-Farm Interactions and Blockage Effects from AWAKEN using Large-Scale Numerical Simulations

A large-scale numerical computation of five wind farms was performed as a part of the American Wake Experiment (AWAKEN). This high-fidelity computation used the ExaWind/AMR-Wind LES solver to simulate a 100km × 100km domain containing 541 turbines under unstable atmospheric conditions matching previous measurements. The turbines were represented by Joukowski and OpenFAST coupled actuator disk models. Results of this qualitative comparison illustrate the interactions with wind farms with large scale ABL structures in the flow, as well as the extent of downstream wake penetration in the flow and blockage effects around wind farms.

Cheung, Lawrence C.↗

Grid-Forming Wind: Getting Ready for Prime Time With and Without Inverters

Variable wind power is one of the fastest-growing energy-generation technologies, harnessing the energy of wind, both on land and at sea. During the past decade, the global share of wind power has grown tremendously, and wind power is evolving into a major contributor to electricity supplies in many countries. In this journey, wind is also becoming a source of reliability services to the grid, which has required grid-supporting functions originally provided by synchronous generators, enabling very high levels of instantaneous penetration (ranging from 60 to 70% in some power systems). To get beyond this, a fundamental shift is required to address challenges associated with the transition to a grid with only a few remaining (or even without any) conventional synchronous generators while achieving a minimum acceptable level of stability.

energy consumption↗

Least-Cost Pathways for India's Electric Power Sector

The Government of India has a target of deploying 175 GW from renewable energy by 2022 and 40% of electricity capacity from renewable energy by 2030 and has indicated that ambitions for 2030 could be higher. Rapid changes in technology costs and performance could drive further deployment of wind and solar capacity beyond these policy targets. Increased deployment of variable renewable energy (VRE) raises new questions for power system planning regarding the optimal siting of generation capacity, trade-offs between generation and transmission infrastructure, and system flexibility needs. This study aims to evaluate least-cost pathways for India's electric power system over the period 2017-2047. Uniquely, this work considers an expanded planning horizon and range of scenarios not previously analyzed in national planning studies in India. The data collection and model design processes undertaken for this study provides a framework for recurring planning studies. This study finds anticipated changes in electricity demand and component costs can drive a significant shift in India's future electricity supply and how this system will be operated. In the Base scenario, the share of generation from VRE reaches 54% by 2047. Reducing the capital cost of wind has a larger impact on VRE penetration than reducing the capital cost of solar PV or battery storage. In the lowest wind cost scenario (40% capital cost decline by 2047 relative to the Base scenario), the penetration of VRE in the generation mix reaches 722%, exceeding the penetration levels achieved when the cost of battery storage or solar PV are reduced by an even greater 50%. In a future system with high penetrations of RE, capacity additions are driven by the coincidence of demand and RE generation rather than peak demand alone. This study finds the system could have surplus capacity during the peak demand months of July–September because this period corresponds to periods with high wind speeds and more wind generation available to meet peak demand. By contrast, new capacity is needed to meet demand during moderate demand months of October–November when output from wind plants falls more than 75% nationally compared to the previous two months. Finally, the success for gas for electricity production may depend on cost competitiveness rather than fuel availability. Increasing the amount of gas available for electricity production had no significant impact on the capacity or generation mix by 2047, as determined from a scenario that significantly increases fuel availability throughout the planning horizon. In fact, over 80% of new gas fuel available for the power sector remains unused. This suggests the high cost of gas plant operations relative to other technologies may constrain the expansion of gas generation in India more than fuel availability.

14 SOLAR ENERGY↗

Impact of High PV Penetration on Voltage Stability

Photovoltaics (PV) are becoming increasingly relevant in modern power systems. With this increase also comes reliability concerns as photovoltaics behave differently than conventional generators. One reliability concern is voltage stability. In this paper, voltage stability of the Austin area in the Electric Reliability Council of Texas (ERCOT) system is studied using dynamic models with varying levels of photovoltaic penetration. The base case is set at 0% renewable penetration. Additional cases include 15% wind penetration and up to 65% photovoltaic penetration. The study results show that voltage/var control capacity is critical to voltage stability, which PV lacks. Voltage regulation of photovoltaics may cause over-voltage and voltage collapse may be more abrupt under high regional photovoltaic penetration.

Till, Jeremy↗

High-temperature thermal energy storage with thermophotovoltaic energy conversion (Final Report)

This project began with a simple concept: that thermal energy storage paired with thermophotovoltaic power conversion could be a cost-effective solution to the challenge of renewables variability. Renewable energy sources such as solar and wind energy are clean, affordable, and abundant worldwide, but their variability presents a major problem for the incorporation of a large amount of these resources in global power systems. Systems with high penetrations of renewables frequently see periods of overproduction, where renewable energy is thrown away, and periods of underproduction, where expensive and polluting fossil fuel resources must be used to fill in the gaps. While energy storage technologies such as lithium ion batteries can help store energy from times of overproduction to times the energy is needed, current and projected future prices for these technologies are not low enough to support very renewables-heavy power grids. The research also focused on the techno-economics of using thermal energy storage and thermophotovoltaics to store the energy from solar and wind energy sources when they are available and release this energy back to the grid when it is needed. One of the biggest outcomes of this research was the conclusion that battery prices must drop 10x from their current values in order to meet this need, and this is unlikely to happen with current technologies such as lithium ion batteries.

14 SOLAR ENERGY↗

Aggregation of Inverter-Based Resources for Modeling and Simulation

In order to conduct system dynamic studies, it is necessary to have dynamic models of both inverter and plant levels. Detailed and aggregated modeling approaches are two essential options. The detailed modeling method involves capturing the dynamic characteristics of each individual device (e.g., wind turbine or PV array), as well as their interconnections. However, as the scale of the IBR plant increases, the complexity and computation time required for detailed modeling also increase. On the other hand, aggregated modeling offers a more efficient way of representing large-scale IBRs in power system dynamic studies. This approach involves aggregating a large number of wind turbines, PV arrays, inverters, and/or plant controllers into one or a smaller number of equivalent models. In order to analyze the impact of a high-level IBR penetration in power systems, it is important to develop accurate and computationally efficient models for both the detailed and aggregated methods.

14 SOLAR ENERGY↗

Impacts of High Variable Renewable Energy Futures on Electric-Sector Decision Making: Demand-Side Effects

Previous work by the Berkeley Lab describes how high shares of variable renewable energy (VRE) such as wind and solar power could change wholesale electricity price dynamics. These include the timing of when electricity is cheap or expensive, locational differences in the cost of electricity, and the degree of regularity or predictability in those costs. Many decentralized decision-makers on the demand-side may not yet have considered the implications of these possible future changes. In this report, we evaluate the sensitivity of a set of demand-side decisions to different levels of VRE penetration ranging from a low of 5-20% to a high of 40-50%. The analysis builds on hourly wholesale energy and capacity prices in different VRE scenarios for four wholesale markets in the United States for the year 2030 (CAISO, ERCOT, NYISO, and SPP). The principal question for this exploration is whether private and public electric-sector decisions that are made based on assumptions reflecting low VRE levels still achieve their intended objective in a high VRE scenario with 40-50% wind and solar? This scoping report evaluates the impacts of changing patterns of peak system needs on the benefits of demand reductions by examining the altered value of different energy efficiency (EE) measures. Similarly, we investigate new opportunities for large energy consumers that may arise from periods with very low wholesale electricity prices. We calculate the value of new process investments (e.g., hydrogen production and other generalized electro-commodities), showcase the varying value of new product storage investments (such as reservoir extensions at a desalination plant), and estimate the benefits of increased process flexibility that uses electricity as a process-input in addition to traditional fossil fuels (e.g., district energy systems). Finally, many decentralized decision-makers and end-use customers are not directly exposed to wholesale electricity prices but instead receive price signals from their retail electricity rates. As wind and solar shares increase, we compare the economic efficiency of flat retail rates relative to more dynamic time-of-use tariffs with and without critical peak-pricing events.

14 SOLAR ENERGY↗

CROCUS Sodar Measurements of Lower Atmospheric Wind Profiles at Argonne Testbed for Multiscale Observational Science (ATMOS) Site

The Scintec MFAS Sodar (Multiple-Frequency Acoustic Sounder) is an autonomous, ground-based acoustic remote sensing system designed to measure vertical profiles of horizontal wind speed, wind direction, and vertical velocity in the lower atmosphere. The instrument transmits sequences of acoustic pulses and detects the Doppler-shifted sound waves backscattered by small-scale temperature and velocity fluctuations caused by atmospheric turbulence. From these Doppler shifts, the system derives three-dimensional wind vectors by combining radial velocities from multiple beam orientations.The MFAS Sodar operates with a first usable range gate beginning at approximately 30 m above ground level and a configurable vertical resolution of 10 m. Under favorable acoustic conditions, the system provides wind profiles extending up to 600 m above ground level. Measurements are processed into 15-minute averaged profiles containing wind speed, direction, vertical velocity, and diagnostic quantities such as signal-to-noise ratio and echo strength.This dataset was collected at the Argonne Testbed for Multiscale Observational Science (ATMOS) facility in Lemont, Illinois, as part of DOE's CROCUS Urban Integrated Field Laboratory (UIFL) initiative. The purpose of these observations is to characterize the vertical wind structure and boundary-layer evolution across the urban–suburban gradient of the greater Chicago region. In particular, these data are intended to improve understanding of how local meteorology, such as lake-breeze penetration, nocturnal jets, and daytime mixing, varies between the densely built urban core and the suburban periphery. The MFAS observations provide critical context for evaluating high-resolution model simulations and for integrating with complementary lidar, radar, and in-situ meteorological measurements within the broader CROCUS UIFL network.All data are archived in NetCDF (Network Common Data Form) format and include wind and diagnostic parameters. The files can be accessed and analyzed using standard software that supports NetCDF, such as Python (e.g., xarray, netCDF4), MATLAB, R (e.g., ncdf4, raster), or Panoply (NASA’s NetCDF visualization application).

54 ENVIRONMENTAL SCIENCES↗

Reliable Protection for an Inverter-Based Resources Dominant Grid: Technology Development and Field Demonstration

The project aimed to address the challenges posed by the rapid growth of inverter-based resources (IBR) such as solar, wind, and battery storage, which have fundamentally changed fault behavior, system strength, and protection performance in bulk power systems. Traditional protection schemes, designed for synchronous generator-dominated grids, are inadequate under high IBR penetration. Overall, the project materially advances protection modeling and simulation capabilities needed to maintain reliable grid protection under high IBR penetration. The results build utility confidence in operating power systems safely and reliably across a wide range of generation mixes, supporting grid modernization goals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ubiquitous Power Electronics in Future Power Systems: Recommendations to fully utilize fast control capabilities

Power electronics is becoming ubiquitous in power systems because the rapid growth of variable renewable generation such as wind and solar, responsive load, electric vehicles, energy storage, as well as DC transmission. As a result, a high percentage of electricity will be generated, transmitted or consumed by power electronics in the future power system. Such a high penetration of power electronics is changing power system operation landscapes and dynamic characteristics. Two major kinds of impact are reduced system mechanical inertia by inverter-based resources displacing conventional generation and active participation of many distributed energy resources through inverters. This has caused significant reliability challenges for power system operation. The mitigation approach so far has mostly focused on accommodating power electronics inverters as passive devices or creating synthetic inertias to make inverter-based generation behaving as conventional generators. However, the high-speed control capabilities of power electronics present new opportunities for achieving an optimal performance beyond conventional power systems. A lower-inertia system can be more responsive for improving reliability, and distributed small resources can be more adaptive and scalable for better flexibility and resilience. Power electronic inverters are capable of multiple fast control functions. To fully utilized the ubiquitous power electronics in power systems requires technology advancements in the following areas: data and communications to capture the new dynamic behaviors introduced by power electronics; modeling and simulation to understand the behaviors of power electronics and its interactions with other components in the context of power systems; control and optimization methods for fully utilizing the capabilities of power electronics for a new paradigm of performance beyond the traditional inertia-heavy system; and significant upgrades in power electronics hardware to cater to the new control capabilities. If properly controlled and optimized, power electronics can help transform the power system to be responsive, adaptive, and scalable.

Huang, Zhenyu↗

Methods for Representing Flexible, Energy-Constrained Technologies in Utility Planning Tools

Capacity expansion models are widely used by power system researchers, planners, and policy analysts to evaluate alternative power system investment scenarios. With the increasing deployment of wind and solar in the US, there has been much focus on improving the representations of variable generation (VG) technologies within capacity expansion models. Models that capture the variable net-load profiles and larger reserve requirements associated with high penetration VG systems represent an improvement to classic capacity expansion models, but fall short of capturing the complexities associated with storage technologies, such as battery energy storage (BES) and concentrating solar power with thermal energy storage (CSP with TES). While difficult to model in a capacity expansion setting, these technologies are potentially competitive sources of flexibility with the intriguing characteristics of being able to absorb VG that would otherwise be curtailed and directly contribute to renewable energy goals, respectively. In this paper we present methods for accurately representing these technologies in a large-scale capacity expansion model with high electrical and geospatial resolution. VG modeling techniques, including novel methods for capturing curtailment due to unit commitment and other hourly dispatch phenomena, are also reviewed. Modeling for a region in the southwestern United States demonstrates the economic relevance of being able to explicitly trade off the costs and capabilities of energy-constrained technologies, especially BES, against other resources in the near-term, in time to make plans for the coming decade

24 POWER TRANSMISSION AND DISTRIBUTION↗

Storage Enabled Flexibility of Conventional Generation Assets (StorFlex)

The power systems have faced progressively more demanding operational requirements over the last two decades. Several factors contribute to these challenging operating conditions, including load growth, aging infrastructure, increasing penetrations of distributed energy resources (DERs), electrification of the economy, and policy initiatives such as decarbonization. The power system and its components must provide high operational flexibility to mitigate these challenges. For example, the proliferation of intermittent DERs such as wind and solar has increased the need for conventional generation assets like hydropower plants to respond to sudden load-generation imbalances. The higher flexibility requirements for hydropower plants cause more wear and tear, potentially shortening the useful lifespan of hydropower turbines. To reduce the need for hydropower plants to follow sudden changes in the dispatch signal, we investigate their combined operation with the energy storage systems (ESSs; “ESS-based hybridization”). Our analyses focuses on improving the lifespan of hydropower plants through ESS-based hybridization. Wear and tear on hydropower turbines (particularly Francis turbines) is modeled using a loss-of-life concept that is based on damage experienced by the turbine due to various cycles of operation. Then, we show that using ESSs to offset some of the high variation increases the remaining life of the hydropower plants. To demonstrate this, a few modeling tools were developed for this work: (1) a dynamic model for various components of the turbine and its governor; (2) a control strategy that assigns a slow-varying dispatch signal to a hydropower unit versus a fastmoving signal to ESS, such that the overall power request remains the same; and (3) models for the financial analysis to quantify the economic merits of such a framework. We used the models we developed to analyze the dispatch pattern of an actual hydropower plant with a power output of 50 MW and a head height of 152 m. This work showed that ESS-based hybridization could extend the life of the hydropower plant by 5% on average. This extension in life was then used to estimate the economic benefit in terms of cost deferrals associated with hydropower plant maintenance and replacement: on average, $3.6 million. Sensitivity analysis with respect to the size of ESS and cost of turbines was performed to show the variation in benefits over the range of turbine costs and ESS sizes. Crucially, stacking damage reduction and lifetime extension with other ESS value streams such as providing ancillary services could substantially increase the financial benefits of ESS-based hybridization. The higher costs associated with ESS of appropriate size would make more financial sense when multiple value streams are stacked and co-optimized to extract the maximum benefit. This dimension will be explored in future work.

13 HYDRO ENERGY↗

Interpretable Data-Driven Probabilistic Power System Load Margin Assessment with Uncertain Renewable Energy and Loads

The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.

deep kernel learning↗

Thoughts and Hypotheses on the Metrics and Needs for the Stability of Highly Inverter-Based Island Systems

As levels of wind, photovoltaics (PVs), and battery energy storage on power systems rise, it is useful to be able to quickly compare how much generation (instantaneous power and annual energy) comes from these inverter-based resources (IBRs). A commonly used metric is the percentage of inverter-based generation (% IBR) in a dispatch scenario (as a percentage of the total generation or total load), which can be useful for estimating when certain operational challenges arise (high rates of change of frequency, underdamped control interactions, low system strength, low fault current availability, and so on). Another similar and commonly used metric pioneered on the relatively large island of Ireland, system nonsynchronous penetration (SNSP), is similar to the % IBR and is subject to similar limitations. SNSP has the advantage of handling high-voltage dc in a defined way.

fault currents↗

Development Support for NREL's System Advisor Model (SAM): Cooperative Research and Development, CRADA Number CRD-20-16998 (Final Report)

The variable nature of renewable generation, which depends on the sun shining and wind blowing for example, presents challenges for adequate and least-cost resource planning. The deployment of renewable generation assets is anticipated to increase due to various drivers, such as declining costs, favorable government policies, and increasing procurement by corporations and consumers. High levels of renewable penetration are anticipated to pose flexibility, reliability, and cost challenges to the electrical system. The development and implementation of new features into performance modeling software, such as the National Renewable Energy Laboratory's (NREL) System Advisor Model (SAM), is one way to help think through these challenges and develop appropriate strategies.

14 SOLAR ENERGY↗

Electrification Futures Study: Power Systems Operation with Newly Electrified and Flexible Loads

The Electrification Futures Study (EFS) is a multi-year study designed to analyze the impacts of widespread electrification in the U.S. energy system. In this webinar we present the detailed power systems operational analysis from the final report in the EFS series. For this analysis, we simulate multiple 2050 power systems for the conterminous United States to assess how variations in the magnitude and shape of electricity demand driven by electrification, and the extent of load participation to more-actively provide grid services, might impact the hourly operation, operational costs, and emissions of various power systems in 2050. The impacts of electrification and demand flexibility are overlayed across systems with significantly greater penetrations of variable renewable energy than today. Overall, we find that the high electrification scenarios envisioned in the EFS with significant VRE penetration (66% of annual national generation) can be operated to meet future increased levels of electrified demand. We also find that demand-side flexibility can enhance operational efficiency and reduce overall annual production costs by $5-$10 billion. The complementary relationship between flexible electric vehicle charging loads and solar generation is particularly pronounced, but in the absence of demand-side flexibility electrification can lead to increased wind and solar curtailment. By helping to reduce renewable curtailment, flexibility can also reduce power sector CO2 emissions. The analysis highlights the value of increased integration and coordination of demand- and supply-side resources in future electric system planning and operations—particularly under high electrification futures.

43 PARTICLE ACCELERATORS↗

Exploring Micro-Environmental Conditions of Urban Agrivoltaics: Advancing Sustainable Green Spaces and Agriculture in Temperate Cities

Agrivoltaics, the integrated land use combining renewable energy production and agriculture, can potentially address key challenges faced by urban communities, including limited access to vacant land, fresh produce, and electricity. However, urban agrivoltaics has rarely been considered a viable solution, primarily due to a lack of experimental systems demonstrating the functionality of urban food production or green spaces alongside solar energy production. To evaluate the potential of solar photovoltaics to help mitigate heat stress on urban agriculture and green spaces in a temperate climate, we examined the microclimatic changes introduced by an urban agrivoltaics system (UrAV) when combined with vegetable crops and turfgrass, respectively. Accordingly, we installed an experimental setup instrumented with environmental sensors to compare full-sun conditions with those of an agrivoltaics system designed for urban environments. We found minimal differences for both land cover types between the control and agrivoltaics sites in air and soil temperature. However, during periods of intensified summer heat, temperatures beneath the panels cooled due to reductions in wind speed and relative humidity, which impeded the movement of hot, moist air and reduced reference evapotranspiration. Further, soil moisture in UrAV was highly spatially heterogeneous, influenced by the layout of the photovoltaic panels and their support structure, which redistributed rainfall and controlled where solar radiation could penetrate and drive evapotranspiration. Overall, our results suggest that PV-induced environmental changes in temperate climates are compatible with cultivating turfgrass or appropriate crops. These findings can help planners and designers integrate agrivoltaics into community gardens, farms, and green spaces in temperate cities.

14 SOLAR ENERGY↗