Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Determining True Sensor Spatial Resolution of Very High Resolution Optical Imagery

Some satellite data is delivered in images with gridded pixels. This gridded pixel size is often assumed to be the spatial resolution of the satellite sensor; however, this is not always the case. An image can be grided to any arbitrary pixel size, but the sensor resolution will remain constant. For example, an image with a pixel grid size much smaller than the sensor resolution will appear blurry along what should be sharp transitions. This discrepancy between an image’s pixel size and true sensor spatial resolution can be the source of much confusion and even misinformation among data users, which may lead them to waste time and resources on using images that do not suit their spatial resolution needs. This presentation will highlight our evaluation of the true spatial resolution of various government and commercial images in the pixel size range of 0.3 m to 60 m. Images evaluated include ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels). Our evaluation of true sensor spatial resolution, or ‘footprint size’ is based on the sensor’s line spread function (LSF). We calculate the width at half the height of the LSF to find the full width at half maximum (FWHM). The FWHM is how we report sensor spatial resolution. Different objects are examined for constructing the LSF depending on the sensor spatial resolution. Coarser resolution sensors in this evaluation such as Sentinel-2 and Landsat 8/9 are examined at bridges over a dark water background. The bright bridge acts as a line impulse, giving a sensor’s line spread function (LSF) in one direction. Additionally, we simulate the impacts of bridge width on the apparent LSF to obtain a true LSF without the effects of bridge width for these sensors. Finer resolution sensors will image the irregularities in bridges such as trusses, sidewalks, and in some cases painted lines, interfering with the LSF construction. Instead, these sensors are evaluated at large (60 m – 140 m) black and white checkerboards known as Cal/Val sites. At these locations, the image’s transition from black to white is extracted as an edge spread function (ESF). We calculate the derivative of this ESF to obtain the sensor’s LSF. From there, we find the FWHM as we do for the coarser resolution images. With the FWHM and pixel size, we determine how over- or under-sampled the images are. When the ratio of a sensor’s spatial resolution and the gridded image’s pixel size is less than 1, the image is considered under-sampled. In this case, each pixel’s information is unique but only a portion of that pixel’s ground area has been measured. On the other side, if the ratio is greater than 1, the image is considered over-sampled. That is, each pixel’s information is sourced from within the ground extent of the pixel and some extent outside additionally. We will show the true spatial resolution and the extent of over-/under-sampling in the imagery from ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels).

Alana Semple↗

Design and Fabrication of Two-Dimensional Semiconducting Bolometer Arrays for the High Resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC-II)

The High resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC 11) will use almost identical versions of an ion-implanted silicon bolometer array developed at the National Aeronautics and Space Administration's Goddard Space Flight Center (GSFC). The GSFC "Pop-Up" Detectors (PUD's) use a unique folding technique to enable a 12 x 32-element close-packed array of bolometers with a filling factor greater than 95 percent. A kinematic Kevlar(Registered Trademark) suspension system isolates the 200 mK bolometers from the helium bath temperature, and GSFC - developed silicon bridge chips make electrical connection to the bolometers, while maintaining thermal isolation. The JFET preamps operate at 120 K. Providing good thermal heat sinking for these, and keeping their conduction and radiation from reaching the nearby bolometers, is one of the principal design challenges encountered. Another interesting challenge is the preparation of the silicon bolometers. They are manufactured in 32-element, planar rows using Micro Electro Mechanical Systems (MEMS) semiconductor etching techniques, and then cut and folded onto a ceramic bar. Optical alignment using specialized jigs ensures their uniformity and correct placement. The rows are then stacked to create the 12 x 32-element array. Engineering results from the first light run of SHARC II at the CalTech Submillimeter Observatory (CSO) are presented.

Voellmer, George M.↗

Design and Fabrication of Two-Dimensional Semiconducting Bolometer Arrays for the High Resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC-II)

The High resolution Airborne Wideband Camera (HAWC) and the Submillimeter High Angular Resolution Camera II (SHARC II) will use almost identical versions of an ion-implanted silicon bolometer array developed at the National Aeronautics and Space Administration's Goddard Space Flight Center (GSFC). The GSFC 'Pop-up' Detectors (PUD's) use a unique folding technique to enable a 12 x 32-element close-packed array of bolometers with a filling factor greater than 95 percent. A kinematic Kevlar(trademark) suspension system isolates the 200 mK bolometers from the helium bath temperature, and GSFC - developed silicon bridge chips make electrical connection to the bolometers, while maintaining thermal isolation. The JFET preamps operate at 120 K. Providing good thermal heat sinking for these, and keeping their conduction and radiation from reaching the nearby bolometers, is one of the principal design challenges encountered. Another interesting challenge is the preparation of the silicon bolometers. They are manufactured in 32-element, planar rows using Micro Electro Mechanical Systems (MEMS) semiconductor etching techniques, and then cut and folded onto a ceramic bar. Optical alignment using specialized jigs ensures their uniformity and correct placement. The rows are then stacked to create the 12 x 32-element array. Engineering results from the first light run of SHARC II at the Caltech Submillimeter Observatory (CSO) are presented.

Voellmer, George M.↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Mesoscale Convective Systems Represented in High Resolution E3SMv2 and Impact of New Cloud and Convection Parameterizations

Mesoscale convective systems (MCSs) play an important role in modulating the global hydrological cycle, general circulation, and radiative energy budget. In this study, we evaluate MCS simulations in the second version of U.S. Department of Energy (DOE) Energy Exascale Earth System Model (E3SMv2). E3SMv2 atmosphere model (EAMv2) is run at the uniform 0.25? horizontal resolution. We track MCSs consistently in the model and observations using the PyFLEXTRKR algorithm, which defines MCS based on both cloud-top brightness temperature (Tb) and surface precipitation. Results from using Tb only to define MCS, commonly used in previous studies, are also discussed. Furthermore, sensitivity experiments are performed to examine the impact of new cloud and convection parameterizations developed for EAMv3 on simulated MCSs. Our results show that EAMv2 simulated MCS precipitation is largely underestimated in the tropics and contiguous United States. This is mainly attributed to the underestimated precipitation intensity in EAMv2. In contrast, the simulated MCS frequency becomes more comparable to observations if MCSs are defined only based on cloud-top Tb. The Tb-based MCS tracking method, however, includes many cloud systems with very weak precipitation which conflicts with the MCS definition. This result illustrates the importance of accounting for precipitation in evaluating simulated MCSs. We also find that the new physics parameterizations help increase the relative contribution of convective precipitation to total precipitation in the tropics, but the simulated MCS properties are generally not improved. This suggests that simulating MCSs will remain a challenge for the next version of E3SM.

Zhang, Meng↗

The Impact of Horizontal and Temporal Resolution on Convection and Precipitation with High-Resolution GEOS-5

Using a high-resolution non-hydrostatic version of GEOS-5 with the cubed-sphere finite-volume dynamical core, the impact of spatial and temporal resolution on cloud properties will be evaluated. There are indications from examining convective cluster development in high resolution GEOS-5 forecasts that the temporal resolution within the model may playas significant a role as horizontal resolution. Comparing modeled convective cloud clusters versus satellite observations of brightness temperature, we have found that improved. temporal resolution in GEOS-S accounts for a significant portion of the improvements in the statistical distribution of convective cloud clusters. Using satellite simulators in GEOS-S we will compare the cloud optical properties of GEOS-S at various spatial and temporal resolutions with those observed from MODIS. The potential impact of these results on tropical cyclone formation and intensity will be examined as well.

Putman, William P.↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Layer Deposited Aluminum‐Based Hybrid Resist for High‐Resolution Nanolithography and Direct Ultra‐High Aspect Ratio Pattern Transfer

Inorganic-containing hybrid photoresists are critical for next-generation extreme ultraviolet (EUV) lithography and angstrom-era semiconductor miniaturization. However, associated conventional solution processing struggles to achieve ultrathin, uniform films with high conformality and compositional control, limiting overall patterning performance. Here, this study reports the systematic lithographic patterning characterization of an Al-based hybrid resist synthesized via vapor-phase molecular layer deposition (MLD), using the trimethylaluminum (TMA) metal precursor and the hydroquinone (HQ) aromatic organic linker. The resist supports both sub-20 nm high-resolution nanolithography and virtually infinite silicon plasma etch selectivity. Lithographic performance studied using electron beam lithography (EBL) as a proxy for EUV shows that, under an optimized process adopting post-exposure bake, the resist achieves the best resolution of 15.4 nm linewidth under stringent 1:1 line-space high-density patterning—limited only by the minimum beam size of the EBL system. The resist also shows wide dose latitude and balanced performance in resolution, roughness, and sensitivity. The infinite silicon etch selectivity, stemming from spontaneous aluminum oxyfluoride passivation layer formation, enables fabrication of micrometer-tall, 40 nm-wide silicon nanofin structures using only a ≈30 nm-thick resist layer, without no hard mask. These results highlight the potential of MLD-based hybrid resists for developing next-generation resist materials for micro/nanoelectronics manufacturing.

36 MATERIALS SCIENCE↗