At least 73 records · Page 4

National Energy Education Development Project (NEED Project) (CRADA Final Report)

The U.S. Department of Energy Building Technologies Office (BTO) funds student competitions that introduce students to careers in the building sciences and increase public awareness around high-performance buildings to support the goal of developing, demonstrating, and accelerating the adoption of cost-effective technologies, techniques, tools, and services that enable high-performing, energy-efficient and demand-flexible residential and commercial buildings in both the new and existing buildings markets. The U.S. Department of Energy Solar Decathlon® (DOE/SD) is a flagship, high-visibility international competition started in 2002 that advances the goals of BTO by introducing students to building science careers; educating students and the public about the latest technologies and materials in high-performance buildings; encouraging student-led projects and research centered around building science; and demonstrating to the public the comfort and savings of homes that combine energy-efficient construction, home systems, appliances and innovative design with onsite renewable energy production. SD is a collegiate competition, comprising 10 contests, that challenges student teams to design and build highly efficient and innovative buildings powered by renewable energy. The winners will be those teams that best blend architectural and engineering excellence with innovation, market potential, building efficiency, and smart energy production. Solar Decathlon is comprised of two Challenges – Design Challenge (annual) and Build Challenge (biennial). The National Renewable Energy Laboratory (NREL) provides competition management for Solar Decathlon. NREL and Participant establish this CRADA to enable the success of the overall Solar Decathlon program by managing sponsorship funds and creating a K12 education program. Participant is to act as an Education Partner to Solar Decathlon, which includes: 1) accepting and dispersing sponsorship funds for DOE/SD; and 2) providing K12 education program to support Solar Decathlon Competition Events in April each year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Passive Vents

This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated source of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Design Guidance for Passive Vents in New Construction Multifamily Buildings, New York, New York

This document addresses the use of passive vents as a source of outdoor air in multifamily buildings. The challenges associated with implementing passive vents and the factors affecting performance are outlined. A comprehensive design methodology and quantified performance metrics are provided. Two hypothetical design examples are provided to illustrate the process. This document is intended to be useful to designers, decision-makers, and contractors implementing passive ventilation strategies. It is also intended to be a resource for those responsible for setting high-performance building program requirements, especially pertaining to ventilation and outdoor air. To ensure good indoor air quality, a dedicated source of outdoor air is an integral part of high-performance buildings. Presently, there is a lack of guidance pertaining to the design and installation of passive vents, resulting in poor system performance. This report details the criteria necessary for designing, constructing, and testing passive vent systems to enable them to provide consistent and reliable levels of ventilation air from outdoors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control Limits for Building Energy End Use Based on Engineering Judgment, Frequency Analysis, and Quantile Regression

Approaches are needed to continuously characterize the energy performance of commercial buildings to allow for (1) timely response to excess energy use by building operators; and (2) building occupants to develop energy awareness and to actively engage in reducing energy use. Energy information systems, often involving graphical dashboards, are gaining popularity in presenting energy performance metrics to occupants and operators in a (near) real-time fashion. Such an energy information system, called Building Agent, has been developed at NREL and incorporates a dashboard for public display. Each building is, by virtue of its purpose, location, and construction, unique. Thus, assessing building energy performance is possible only in a relative sense, as comparison of absolute energy use out of context is not meaningful. In some cases, performance can be judged relative to average performance of comparable buildings. However, in cases of high-performance building designs, such as NREL's Research Support Facility (RSF) discussed in this report, relative performance is meaningful only when compared to historical performance of the facility or to a theoretical maximum performance of the facility as estimated through detailed building energy modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Through the Past Decade: How Advanced Energy Design Guides have influenced the Design Industry

Advanced Energy Design Guides (AEDGs) were originally developed intended to provide a simple approach to building professionals seeking energy efficient building designs better than ASHRAE Standard 90.1. Since its first book was released in 2004, the AEDG series provided inspiration for the design industry and were seen by designers as a starting point for buildings that wished to go beyond minimum codes and standards. In addition, U.S. Department of Energy’s successful Commercial Building Partnerships (CBP) program leveraged many of the recommendations from the AEDGs to achieve 50% energy savings over ASHRAE Standard 90.1-2004 for prototypical designs of large commercial entities in the retail, banking and lodging sectors. Low-energy technologies and strategies developed during the CBP process have been applied by commercial partners throughout their national portfolio of buildings. Later, the AEDGs served as the perfect platform for both Standard 90.1 and ASHRAE’s high performance buildings standard, Standard 189.1. What was high performance a few years ago, however, has become minimum code today. Indeed, most of the prescriptive envelope component requirements in ASHRAE Standard 90.1-2013 are values recommended in the 50% AEDGs several years ago. Similarly, AEDG strategies and recommendations have penetrated the lighting and HVAC sections of both Standard 189.1 and Standard 90.1. Finally, as we look to the future of codes and standards, the AEDGs are serving as a blueprint for how minimum code requirements could be expressed. By customizing codes to specific building types, design strategies tailored for individual buildings could be prescribed as minimum code, just like in the AEDGs. This paper describes the impact that AEDGs have had over the last decade on the design industry and how they continue to influence the future of codes and Standards. From design professionals to code officials, everyone in the building industry has been affected by the AEDGs.

Advanced Energy Design Guides↗

New Whole-House Solutions Case Study: Lancaster County Career and Technology Center Green Home 3 - Mount Joy, Pennsylvania

This case study describes a unique vocational program at Lancaster County Career Technology Center in Mount Joy, PA, where high school students are gaining hands-on construction experience in building high performance homes with help from Building America team, Home Innovation Research Labs. This collaboration resulted in the Green Home 3, the third in a series of high performance homes for Apprentice Green. As one of LCCTC’s key educational strategies for gaining practical experience, students are involved in building real houses that incorporate state-of-the-art energy efficiency and green technologies. With two homes already completed, the Green Home 3 achieved a 44% whole-house energy savings over the Building America New Construction B10 Benchmark, DOE Zero Energy Ready Home (formerly Challenge Home) certification, and National Green Building Standard Gold-level certification.

BUILDING AMERICA↗

High Performance Healthcare Buildings: A Roadmap to Improved Energy Efficiency

This document presents a road map for improving the energy efficiency of hospitals and other healthcare facilities. The report compiles input from a broad array of experts in healthcare facility design and operations. The initial section lists challenges and barriers to efficiency improvements in healthcare. Opportunities are organized around the following ten themes: understanding and benchmarking energy use; best practices and training; codes and standards; improved utilization of existing HVAC designs and technology; innovation in HVAC design and technology; electrical system design; lighting; medical equipment and process loads; economic and organizational issues; and the design of next generation sustainable hospitals. Achieving energy efficiency will require a broad set of activities including research, development, deployment, demonstration, training, etc., organized around 48 specific objectives. Specific activities are prioritized in consideration of potential impact, likelihood of near- or mid-term feasibility and anticipated cost-effectiveness. This document is intended to be broad in consideration though not exhaustive. Opportunities and needs are identified and described with the goal of focusing efforts and resources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baxter Community—High Performance Green Building

This case study describes the Baxter community built by David Weekley Homes, which is reducing their energy demand through a number of techniques including advanced air sealing techniques, the installation of SEER 14 air conditioners, and Low-e windows in conjunction with conventional framing and insulation.

Building Science Corporation↗

Quality Assurance Roadmap for High Performance Residential Buildings

This report outlines the approach to quality assurance in the construction process for new residential construction, including seven process steps from the assessment of current construction practice, through design and documentation changes, to training and quality control for on-site personnel.

Building Science Corporation↗

NREL’s Advanced Analytics Research for Energy-Efficient Buildings

At NREL, we believe in building better buildings. More importantly, high-performance buildings that can do more and be smarter than ever before. Forty percent of the total energy consumption in the United States comes from buildings. Working together, we can dramatically shrink that number. But first, it starts with the research: our observations, experiments, modeling, analysis, and more. NREL’s advanced analytics research has already proven to reduce energy use, save money, and stabilize the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy-saving technologies for building heating, ventilation, and air conditioning systems

Buildings are responsible for about 38-quadrillion BTU of the total energy in the U.S. at present. The energy demands from buildings keep increasing remarkably to meet the improving life level and the needs of occupants' thermal comfort in the future. Therefore, the developments of high-performance building and efficient building energy systems are highly needed to address the challenges of the climate changes and energy depletion. In this paper, we provide a critical review of the studies on energy-saving technologies for building heating, ventilation, and air conditioning (HVAC) systems. We start with the heat recovery technologies applied to HVAC systems. We continue with the reviews on energy-efficient technologies in heating, cooling, and air dehumidification. After a brief background, we focus on the aspects of those systems: advanced materials, component and system design, and system performance. We highlight the recently emergent design, modeling, and experimental research on those technologies and provide the suggestions and outlook for future research and development of energy-efficient building HVAC systems.

Qu, Ming↗

Final Project Report

This project pursued innovations to improve energy efficiency and indoor environmental quality (IEQ) in commercial and residential buildings. For commercial buildings, the project developed a testbed for “intelligent nested environmental systems technologies (iNEST),” which monitor and control energy flows and IEQ across a cascade of spaces from individuals’ desktops to office suites to floors to whole buildings. An iNEST testbed was constructed at Syracuse University and was used to assess the use of devices such as personal badges and CO2 sensors to study how reduced energy use and improved IEQ could be achieved. For residential buildings, resources were targeted in support of DoE’s Builders Challenge Program and to recruit Syracuse, NY builders. Three homes in Syracuse’s Near Westside neighborhood were also registered under the program by Syracuse University team, with an additional home registered by one of the builders. Findings from the work at the iNEST testbed facility, and results from other related projects were disseminated through Syracuse Center of Excellence in Environmental and Energy Systems (SyracuseCoE) 2008 Annual Symposium, the 9th International Healthy Buildings 2009 Conference & Exhibition, and through SyracuseCoE’s website and eNewsletters to inform the broader community of researchers, designers and builders. These public communication activities helped enhance the understanding of high performance buildings and facilitate further market acceptance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Efficient Low-Lift cooling with Radiant Distribution, Thermal Storage and Variable-Speed Chiller Controls

The U.S. Department of Energy’s Building Technologies Program goal is to develop cost-effective technologies and building practices that will enable the design and construction of net-zero energy buildings by 2025. To support this goal, Pacific Northwest National Laboratory evaluated an integrated technology that through utilization of synergies between emerging heating, ventilation and air conditioning systems can significantly reduce energy consumption in buildings. This set consists of thermal storage, dedicated outdoor air system, radiant heating/cooling with a variable speed low-lift-optimized vapor compression system. The results show that the low-lift cooling system provides significant energy savings in many building types and climates locations. This market represents well over half of the entire U.S. commercial building sector. This analysis shows that significant cooling system efficiency gains can be achieved by integrating low-lift cooling technologies. The cooling energy savings for a standard-performance building range from 37% to 84% and, for a high-performance building, from -9% to 70%.

25 ENERGY STORAGE↗

OpenStudio: An Open Source Integrated Analysis Platform; Preprint

High-performance buildings require an integrated design approach for all systems to work together optimally; systems integration needs to be incorporated in the earliest stages of design for efforts to be cost and energy-use effective. Building designers need a full-featured software framework to support rigorous, multidisciplinary building simulation. An open source framework - the OpenStudioSoftware Development Kit (SDK) - is being developed to address this need. In this paper, we discuss the needs that drive OpenStudio's system architecture and goals, provide a development status report (the SDK is currently in alpha release), and present a brief case study that illustrates its utility and flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Lighting Solutions Webtool Peer Review Report, Office Solutions

The Commercial Lighting Solutions (CLS) project directly supports the U.S. Department of Energy’s Commercial Building Energy Alliance efforts to design high performance buildings. CLS creates energy efficient best practice lighting designs for widespread use, and they are made available to users via an interactive webtool that both educates and guides the end user through the application of the Lighting Solutions. This report summarizes the peer review of the CLS webtool for offices. The methodology for the peer review process included data collection (stakeholder input), analysis of the comments, and organization of the input into categories for prioritization of the comments against a set of criteria. Based on this process, recommendations were developed for the release of version 2.0 of the webtool at the Lightfair conference in Las Vegas in May 2010. The report provides a list of the top ten most significant and relevant improvements that will be made within the webtool for version 2.0 as well as appendices containing the comments and short-term priorities in additional detail. Peer review comments that are considered high priority by the reviewers and the CLS team but cannot be completed for Version 2.0 are listed as long-term recommendations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗