Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high field sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Probing topological phase transitions using high-harmonic generation

We report the prediction and realization of topological insulators have sparked great interest in experimental approaches to the classification of materials. The phase transition between non-trivial and trivial topological states is important, not only for basic materials science but also for next-generation technology, such as dissipation-free electronics. It is therefore crucial to develop advanced probes that are suitable for a wide range of samples and environments. Here we demonstrate that circularly polarized laser-field-driven high-harmonic generation is distinctly sensitive to the non-trivial and trivial topological phases in the prototypical three-dimensional topological insulator bismuth selenide. The phase transition is chemically initiated by reducing the spin–orbit interaction strength through the substitution of bismuth with indium atoms. We find strikingly different high-harmonic responses of trivial and non-trivial topological surface states that manifest themselves as a conversion efficiency and elliptical dichroism that depend both on the driving laser ellipticity and the crystal orientation. The origins of the anomalous high-harmonic response are corroborated by calculations using the semiconductor optical Bloch equations with pairs of surface and bulk bands. As a purely optical approach, this method offers sensitivity to the electronic structure of the material, including its nonlinear response, and is compatible with a wide range of samples and sample environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coupling Warm Rain With an Eddy Diffusivity/Mass Flux Parameterization: 2. Sensitivities and Comparison to Observations

Abstract This is the second part of the description and validation of the coupling of a warm‐rain microphysics scheme to a stochastic multi‐plume eddy‐diffusivity/mass‐flux parameterization. Part 1 provides the model description and initial validation of the parameterization in a single column model (SCM) against large eddy simulations. This manuscript provides additional comparisons against satellite observations of 500 unique simulation cases, an analysis of model parameter‐based sensitivities in those 500 cases, and an evaluation of the idealized LES case study paradigm for parameterization development. The SCM is forced by a weather reanalysis in the subtropical northeast Pacific region characterized by the stratocumulus‐to‐cumulus cloud transition. 18 scalar outputs are examined to identify the sensitivities to 22 of the model's parameters. The model is highly sensitive to parameters that determine the behavior of convective plumes, which collectively lead to the most sensitivity in 13 of the 18 outputs. Only a few parameters contribute sensitivities that are not highly correlated with those of other parameters. While forcing the model with two canonical field campaign cases results in similar picture of which parameters lead to high sensitivity in model outputs, the sensitivity magnitudes can be overestimated compared to when the model is forced by weather reanalyzes.

54 ENVIRONMENTAL SCIENCES↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

3D modeling of deep borehole electromagnetic measurements with energized casing source for fracture mapping at the Utah Frontier Observatory for Research in Geothermal Energy

Here, we present a 3D numerical modelling analysis evaluating the deployment of a borehole electromagnetic measurement tool to detect and image a stimulated zone at the Utah Frontier Observatory for Research in Geothermal Energy geothermal site. As the depth to the geothermal reservoir is several kilometres and the size of the stimulated zone is limited to several 100 m, surface-based controlled-source electromagnetic measurements lack the sensitivity for detecting changes in electrical resistivity caused by the stimulation. To overcome the limitation, the study evaluates the feasibility of using a three-component borehole magnetic receiver system at the Frontier Observatory for Research in Geothermal Energy site. To provide sufficient currents inside and around the enhanced geothermal reservoir, we use an injection well as an energized casing source. To efficiently simulate energizing the injection well in a realistic 3D resistivity model, we introduce a novel modelling workflow that leverages the strengths of both 3D cylindrical-mesh-based electromagnetic modelling code and 3D tetrahedral-mesh-based electromagnetic modelling code. The former is particularly well-suited for modelling hollow cylindrical objects like casings, whereas the latter excels at representing more complex 3D geological structures. In this workflow, our initial step involves computing current densities along a vertical steel-cased well using a 3D cylindrical electromagnetic modelling code. Subsequently, we distribute a series of equivalent current sources along the well's trajectory within a complex 3D resistivity model. We then discretize this model using a tetrahedral mesh and simulate the borehole electromagnetic responses excited by the casing source using a 3D finite-element electromagnetic code. This multi-step approach enables us to simulate 3D casing source electromagnetic responses within a complex 3D resistivity model, without the need for explicit discretization of the well using an excessive number of fine cells. We discuss the applicability and limitations of this proposed workflow within an electromagnetic modelling scenario where an energized well is deviated, such as at the Frontier Observatory for Research in Geothermal Energy site. Using the workflow, we demonstrate that the combined use of the energized casing source and the borehole electromagnetic receiver system offer measurable magnetic field amplitudes and sensitivity to the deep localized stimulated zone. The measurements can also distinguish between parallel-fracture anisotropic reservoirs and isotropic cases, providing valuable insights into the fracture system of the stimulated zone. Besides the magnetic field measurements, vertical electric field measurements in the open well sections are also highly sensitive to the stimulated zone and can be used as additional data for detecting and imaging the target. We can also acquire additional multiple-source data by grounding the surface electrode at various locations and repeating borehole electromagnetic measurements. This approach can increase the number of monitoring data by several factors, providing a more comprehensive dataset for analysing the deep-localized stimulated zone. The numerical analysis indicates that it is feasible to use the combination of the energized casing and downhole electromagnetic measurements in monitoring localized stimulated zone at large depths.

58 GEOSCIENCES↗

Development of a Small-Aperture Cos-theta Dipole Insert Coil Based on Bi2212 Rutherford Cable and Stress Management Structure

The U.S. Magnet Development Program (US-MDP) is developing high-field accelerator magnets with magnetic fields beyond the limits of Nb3Sn technology based on high temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212). However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are substantial in high-field accelerator magnets. To prevent large degradation of the Bi2212 coils and achieve the required field quality, an innovative design which provides turn positioning during coil fabrication and operation and manage azimuthal and radial strains/stresses in the coil has been proposed at FNAL. This paper describes the development of a small-aperture two-layer Bi2212 dipole coil with stress management. The main parameters of the Bi2212 wire and Rutherford cable, the design of coil stress management structure and its plastic model, the coil mechanical analysis in the dipole mirror configuration are presented and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Overview of Quantum Sensing Materials and Techniques for Energy Sector Applications

The energy sector is dependent upon highly sensitive sensing devices for a wide range of applications. Variables such as temperature, pH, electromagnetic fields, and pressure must be measured with high precision, often in harsh conditions (e.g. high temperature, pressure and humidity). These sensors are deployed in infrastructure such as transformers, pipelines, mines, nuclear power plants, and other areas to ensure safe operating conditions and uninterrupted, optimized service. Moreover, new opportunities for sensors have emerged due to the expansion of smart grids/meters, driverless vehicles, and the discovery of new oil/gas deposits. The continued maturation of quantum sensors offers exciting opportunities for quantum-enhanced measurements to improve sensitivity beyond the classical limit. Here, an overview of established and emerging quantum materials and methods for sensing applications will be provided. Opportunities within the energy sector for quantum sensors will then be analyzed, including oil/gas discovery, greenhouse gas emission monitoring, pH and ion sensing, current measurements, and quantum-enhanced spectroscopy, along with barriers such as quantum sensor platform miniaturization and ruggedization. A specific project at the National Energy Technology Laboratory involving the functionalization of qubits using metal-organic frameworks for enhanced quantum sensing will then be highlighted. Here, nitrogen vacancy centers (NV) in nanodiamonds, a commercially available qubit with long coherence times and utilizable quantum properties at room temperature, are encapsulated using the metal-organic framework ZIF-8. Significantly, the ZIF-8 coating increases the longitudinal spin relaxation lifetime of the NV centers, an important parameter for spin relaxometry-based quantum sensing experiments. These results demonstrate the importance of qubit functionalization as a crucial step for rationally designing high performance quantum sensors.

Crawford, Scott↗

Conceptual Design of A 20 T Dipole Based on Hybrid REBCO/Nb 3 Sn Cos-theta Coil

This paper presents a design concept of an HTS/LTS hybrid dipole with 50 mm aperture and 20 T nominal field based on a cos-theta coil and a cold iron yoke. The HTS part of magnet coil uses REBCO Twisted Stacked Tape cable. The LTS part is graded and made of two Nb3Sn Rutherford cables. Due to high sensitivity of HTS/LTS coils to large stresses and strains at high fields, a Stress Management (SM) concept combined with the cos-theta coil geometry is used. The results of magnet magnetic analysis are presented and discussed.

43 PARTICLE ACCELERATORS↗

Revealing nano-scale lattice distortions in implanted material with 3D Bragg ptychography

Small ion-irradiation-induced defects can dramatically alter material properties and speed up degradation. Unfortunately, most of the defects irradiation creates are below the visibility limit of state-of-the-art microscopy. As such, our understanding of their impact is largely based on simulations with major unknowns. Here we present an x-ray crystalline microscopy approach, able to image with high sensitivity, nano-scale 3D resolution and extended field of view, the lattice strains and tilts in crystalline materials. Using this enhanced Bragg ptychography tool, we study the damage helium-ion-irradiation produces in tungsten, revealing a series of crystalline details in the 3D sample. Our results lead to the conclusions that few-atom-large ‘invisible’ defects are likely isotropic in orientation and homogeneously distributed. A partially defect-denuded region is observed close to a grain boundary. These findings open up exciting perspectives for the modelling of irradiation damage and the detailed analysis of crystalline properties in complex materials.

42 ENGINEERING↗

Frequentist cosmological constraints from full-shape clustering measurements in DESI DR1

We present a frequentist analysis of clustering measurements from Data Release 1 of the Dark Energy Spectroscopic Instrument (DESI) using the standard profile likelihood method. While Bayesian inferences for effective field theory models of galaxy clustering can be highly sensitive to prior choices for extended cosmological models, frequentist inferences are not susceptible to such effects. We compare frequentist and Bayesian constraints for the parameter set {σ 8 , H 0 , Ω m , w 0 , w a } using the full-shape power spectrum multipoles, post-reconstruction baryon acoustic oscillation (BAO) measurements, and external datasets from the CMB and type Ia supernovae measurements. The frequentist confidence intervals are significantly shifted relative to the Bayesian credible intervals for the w 0 w a CDM model, unless supernovae data are included. When DESI full-shape and BAO data are fit jointly, we obtain the following 1σ frequentist confidence intervals for ΛCDM (w 0 w a CDM): σ 8 = 0.863 +0.048 -0.040 , H 0 = 68.96 +0.81 -0.80 km s -1 Mpc -1 , Ω m = 0.3034 ± 0.0110 (σ 8 = 0.782 +0.060 -0.036 , H 0 = 63.7 +4.2 -2.0 km s -1 Mpc -1 , Ω m = 0.378 +0.024 -0.047 , w 0 = -0.16 +0.10 -0.50 , w a = -3.0 +1.7 ), corresponding to 0.8σ, 0.3σ, 0.7σ (2.1σ, 4.1σ, 6.5σ, 6.3σ, 6.6σ) shifts between the maximum likelihood estimate and the Bayesian posterior mean for ΛCDM (w 0 w a CDM) respectively.

Bayesian reasoning↗

Overview of Quantum Sensing Materials and Techniques for Energy Sector Applications

The energy sector has become increasingly dependent upon highly sensitive sensing devices for a wide range of applications. Variables such as temperature, pH, electromagnetic fields, ions, and pressure must be measured with high precision, often in harsh conditions (e.g. highly corrosive environments due to high temperature, pressure and humidity). These sensors are deployed in infrastructure such as transformers, pipelines, mines, nuclear power plants, and other areas to ensure safe operating conditions and uninterrupted, optimized service. Moreover, new opportunities for sensors have emerged due to the expansion of smart grids/meters, driverless vehicles, and the discovery of new oil, gas, and critical mineral deposits. The continued maturation of quantum sensing technologies offers exciting opportunities for quantum-enhanced measurements within the energy sector that may provide significant improvements in sensitivity beyond the classical limit. Here, an overview of established and emerging quantum materials for sensing applications will be provided, from trapped ions to color centers in diamond and silicon carbide. Associated quantum sensing methods for these materials will be discussed, with an emphasis on platforms that are nearing commercial viability. Specific application opportunities within the energy sector for quantum sensors will then be analyzed, including oil/gas discovery, greenhouse gas emission monitoring, pH and ion sensing, current measurement in electric vehicle batteries, and quantum-enhanced spectroscopy. Remaining barriers, such as quantum sensor platform miniaturization and ruggedization, will also be analyzed. A specific project at the National Energy Technology Laboratory involving the functionalization of qubits using metal-organic frameworks for enhanced quantum sensing will also be highlighted. Here, nitrogen vacancy centers (NV) in nanodiamonds, a commercially available qubit with long coherence times and utilizable quantum properties at room temperature, are encapsulated in a controlled way using the metal-organic framework ZIF-8. The ZIF-8 provides a well-defined, porous scaffold that can be controlled to promote the selective uptake of specific target analytes, such as gas molecules or ions. The quantum sensing performance of this composite material is either preserved or enhanced following ZIF-8 encapsulation; the optically detected magnetic resonance response of the NV nanodiamonds with and without the ZIF-8 coating are identical, while the ZIF-8 coating increases the longitudinal spin relaxation lifetime (T1) of the NV centers, an important parameter for spin relaxometry-based quantum sensing experiments. Taken together, these results demonstrate the importance of qubit functionalization as a crucial step for rationally designing high performance quantum sensors.

Crawford, Scott↗

Dielectrophoresis assisted rapid, selective and single cell detection of antibiotic resistant bacteria with G-FETs

Time-consuming, expensive and low sensitivity diagnostic methods used for monitoring bacterial infections lead to unnecessary or delays in prescription of the right antibiotic treatment. Determining an optimal clinical treatment requires rapid detection and identification of pathogenic bacteria and their sensitivity to specific antimicrobials. However, diagnostic devices that meet all of these criteria have proven elusive thus far. Graphene field effect transistors (G-FET) are a promising solution, since they are highly sensitive to chemical/biological modification, can have fast detection times and can be placed on different substrates. Here, by integrating specific peptide probes over G-FETs, we present a proof-of-concept study for species and strain specific label-free detection of clinical strains of pathogenic bacteria with high specificity and sensitivity. We found that pyrene-conjugated peptides immobilized on G-FETs were capable of detecting pathogenic Staphylococcus aureus at the single-cell level and discriminate against other gram-positive and gram-negative bacterial pathogens. A similar device was able to discriminate between antibiotic resistant and sensitive strains of Acinetobacter baumannii , suggesting that these devices can also be used for detecting antibiotic resistive pathogens. Furthermore, a new means of enhancing attachment, electric-field assisted binding, reduced the detection limit to 104 cells/ml and the detection time to below 5 minutes. Here, the combination of single step attachment, inexpensive production, rapid, selective and sensitive detection suggest G-FETs plus pyrene-conjugated peptides are a new platform for solving major challenges faced in point of care diagnostics to fight infectious diseases and antimicrobial resistance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Narrow-line Seyfert 1 galaxies in Sloan Digital Sky Survey: a new optical spectroscopic catalogue

ABSTRACT Narrow-line Seyfert 1 (NLSy1) galaxies are an enigmatic class of active galactic nuclei (AGN) that exhibit peculiar multiwavelength properties across the electromagnetic spectrum. For example, these sources have allowed us to explore the innermost regions of the central engine of AGN using X-ray observations and have also provided clues about the origin of relativistic jets considering radio and gamma-ray bands. Keeping in mind the ongoing and upcoming wide-field, multifrequency sky surveys, we present a new catalogue of NLSy1 galaxies. This was done by carrying out a detailed decomposition of >2 million optical spectra of quasars and galaxies from the Sloan Digital Sky Survey Data Release 17 (SDSS-DR17) using the publicly available software ‘Bayesian AGN Decomposition Analysis for SDSS Spectra’. The catalogue contains 22656 NLSy1 galaxies which is more than twice the size of the previously identified NLSy1s based on SDSS-DR12. As a corollary, we also release a new catalogue of 52273 broad-line Seyfert 1 (BLSy1) galaxies. The estimated optical spectral parameters and derived quantities confirm the previously known finding of NLSy1 galaxies being AGN powered by highly accreting, low-mass black holes. We conclude that this enlarged sample of NLSy1 and BLSy1 galaxies will enable us to explore the low-luminosity end of the AGN population by effectively utilizing the sensitive, high-quality observations delivered by ongoing/upcoming wide-field sky surveys. The catalogue has been made public at https://www.ucm.es/blazars/seyfert.

Paliya, Vaidehi S. (ORCID:0000000177745308)↗

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING↗

Revealing Fermi surface evolution and Berry curvature in an ideal type-II Weyl semimetal

Abstract In type-II Weyl semimetals (WSMs), the tilting of the Weyl cones leads to the coexistence of electron and hole pockets that touch at the Weyl nodes. These electrons and holes experience the Berry curvature generated by the Weyl nodes, leading to an anomalous Hall effect that is highly sensitive to the Fermi level position. Here we have identified field-induced ferromagnetic MnBi 2-x Sb x Te 4 as an ideal type-II WSM with a single pair of Weyl nodes. By employing a combination of quantum oscillations and high-field Hall measurements, we have resolved the evolution of Fermi-surface sections as the Fermi level is tuned across the charge neutrality point, precisely matching the band structure of an ideal type-II WSM. Furthermore, the anomalous Hall conductivity exhibits a heartbeat-like behavior as the Fermi level is tuned across the Weyl nodes, a feature of type-II WSMs that was long predicted by theory. Our work uncovers a large free carrier contribution to the anomalous Hall effect resulting from the unique interplay between the Fermi surface and diverging Berry curvature in magnetic type-II WSMs.

36 MATERIALS SCIENCE↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conceptual Design of a HTS Dipole Insert Based on Bi2212 Rutherford Cable

The U.S. Magnet Development Program (US-MDP) is aimed at developing high-field accelerator magnets with magnetic fields beyond the limits of Nb 3 Sn technology. Recent progress with composite wires and Rutherford cables based on the first generation high-temperature superconductor Bi 2 Sr 2 CaCu 2 O 8-x (Bi2212) allows considering them for this purpose. However, Bi2212 wires and cables are sensitive to transverse stresses and strains, which are large in high-field accelerator magnets. This requires magnet designs with stress management concepts to control azimuthal and radial strains in the coil windings and prevent the degradation of the current carrying capability of Bi2212 conductor or even its permanent damage. This paper describes a novel stress management approach, which was developed at Fermilab for high-field large-aperture Nb 3 Sn accelerator magnets, and is now being applied to high-field dipole inserts based on Bi2212 Rutherford cables. The insert conceptual design and main parameters, including the superconducting wire and cable, as well as the coil stress management structure, key technological steps and approaches, test configurations and their target parameters, are presented and discussed.

43 PARTICLE ACCELERATORS↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concept of Very-Asymmetric lepton Collider for dark matter search

Accelerator-based searches for dark matter are aiming for high sensitivity and need an experimental setup with high luminosity. This field of research is often called intensity frontier physics. One of the best motivated portals of interaction between dark matter and ordinary matter is a dark photon which could be observed as a resonance in the invariant mass of the decay products. Electron–positron collisions are known to be the cleanest interaction for such a study. In this paper we propose a scheme for a collider which allows for a luminosity of a few orders of magnitude higher than could be obtained in a conventional symmetric collider and with a few times higher accessible mass than is possible using a positron beam and a fixed target approach. The key concept is based on asymmetric energies: a high-energy circulating positron beam and a low-energy high-intensity electron beam, and optimization of the beam interaction region. We present here a configuration of a collision region of 10 MeV electron and 4 GeV positron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗