Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating and cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Middle atmosphere project: A radiative heating and cooling algorithm for a numerical model of the large scale stratospheric circulation

A Curtis matrix is used to compute cooling by the 15 micron and 10 micron bands of carbon dioxide. Escape of radiation to space and exchange the lower boundary are used for the 9.6 micron band of ozone. Voigt line shape, vibrational relaxation, line overlap, and the temperature dependence of line strength distributions and transmission functions are incorporated into the Curtis matrices. The distributions of the atmospheric constituents included in the algorithm, and the method used to compute the Curtis matrices are discussed as well as cooling or heating by the 9.6 micron band of ozone. The FORTRAN programs and subroutines that were developed are described and listed.

Wehrbein, W. M.↗

Heat pipe cooling for scramjet engines

Liquid metal heat pipe cooling systems have been investigated for the combustor liner and engine inlet leading edges of scramjet engines for a missile application. The combustor liner is cooled by a lithium-TZM molybdenum annular heat pipe, which incorporates a separate lithium reservoir. Heat is initially absorbed by the sensible thermal capacity of the heat pipe and liner, and subsequently by the vaporization and discharge of lithium to the atmosphere. The combustor liner temperature is maintained at 3400 F or less during steady-state cruise. The engine inlet leading edge is fabricated as a sodium-superalloy heat pipe. Cooling is accomplished by radiation of heat from the aft surface of the leading edge to the atmosphere. The leading edge temperature is limited to 1700 F or less. It is concluded that heat pipe cooling is a viable method for limiting scramjet combustor liner and engine inlet temperatures to levels at which structural integrity is greatly enhanced.

Silverstein, Calvin C.↗

Prototype solar heating and cooling systems

Prototype solar heating and cooling systems are described. Development, manufacture, test, system installation, maintenance, problem resolution, and performance evaluation are discussed.

Source record↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Can Cooling and Heating Functions Be Modeled with Homogeneous Radiation Fields?

Abstract Cooling and heating functions describe how radiative processes impact the thermal state of a gas as a function of its temperature and other physical properties. In a most general case the functions depend on the detailed distributions of ionic species and on the radiation spectrum. Hence, these functions may vary on a very wide range of spatial and temporal scales. In this paper, we explore cooling and heating functions between 5 ≤ z ≤ 10 in simulated galaxies from the Cosmic Reionization On Computers project. We compare three functions: (1) the actual cooling and heating rates of hydrodynamic cells as a function of cell temperature, (2) the median cooling and heating functions computed using median interstellar medium (ISM) properties (median ISM), and (3) the median of the cooling and heating functions of all gas cells (instantaneous). We find that the median ISM and instantaneous approaches to finding a median cooling and heating function give identical results within the spread due to cell-to-cell variation. However, the actual cooling (heating) rates experienced by the gas at different temperatures in the simulations do not correspond to either summarized cooling (heating) functions. In other words, the thermodynamics of the gas in the simulations cannot be described by a single set of a cooling plus a heating function with a spatially constant radiation field that could be computed with common tools, such as CLOUDY.

79 ASTRONOMY AND ASTROPHYSICS↗

Market potential for solar heating and cooling in buildings

The use of solar heating and cooling for buildings as a method of conserving fossil fuels is discussed. The residential and commercial end use consumption of energy is tabulated. A survey to project the energy requirements for home and industry heating and cooling is developed. The survey indicates that there is a market potential for solar heating and cooling of buildings. A prediction of three to five billion dollars per year as the potential for solar heating and cooling is made.

Source record↗

Mobile heat pipe cooled fast reactor system

A mobile heat pipe cooled fast nuclear reactor may be configured for transportation to remote locations and may be able to provide 0.5 to 2 megawatts of power. The mobile heat pipe cooled fast reactor may contain a plurality of heat pipes that are proximate to a plurality of fuel pins inside the reactor. The plurality of heat pipes may extend out of the reactor. The reactor may be configured to be placed in a standard shipping container, and may further be configured to be contained within a cask and attached to a skid for easier transportation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mobile heat pipe cooled fast reactor system

A mobile heat pipe cooled fast nuclear reactor may be configured for transportation to remote locations and may be able to provide 0.5 to 2 megawatts of power. The mobile heat pipe cooled fast reactor may contain a plurality of heat pipes that are proximate to a plurality of fuel pins inside the reactor. The plurality of heat pipes may extend out of the reactor. The reactor may be configured to be placed in a standard shipping container, and may further be configured to be contained within a cask and attached to a skid for easier transportation.

McClure, Patrick Ray↗

On the minimum number of radiation field parameters to specify gas cooling and heating functions

Fast and accurate approximations of gas cooling and heating functions are needed for hydrodynamic galaxy simulations. We use machine learning to analyze atomic gas cooling and heating functions in the presence of a generalized incident local radiation field computed by Cloudy. We characterize the radiation field through binned radiation field intensities instead of the photoionization rates used in our previous work. We find a set of 6 energy bins whose intensities exhibit relatively low correlation. We use these bins as features to train machine learning models to predict Cloudy cooling and heating functions at fixed metallicity. We compare the relative SHapley Additive exPlanation (SHAP) value importance of the features. From the SHAP analysis, we identify a feature subset of 3 energy bins (0.5-1, 1-4, and 13-16Ry) with the largest importance and train additional models on this subset. We compare the mean squared errors and distribution of errors on both the entire training data table and a randomly selected 20% test set withheld from model training. The machine learning models trained with 3 and 6 bins, as well as 3 and 4 photoionization rates, have comparable accuracy everywhere, with errors ≳10 times smaller than for the interpolation table of Gnedin and Hollon (2012). We conclude that 3 energy bins (or 3 analogous photoionization rates: molecular hydrogen photodissociation, neutral hydrogen HI, and fully ionized carbon CVI) are sufficient to characterize the dependence of the gas cooling and heating functions on our assumed incident radiation field model.

79 ASTRONOMY AND ASTROPHYSICS↗

On the minimum number of radiation field parameters to specify gas cooling and heating functions

Fast and accurate approximations of gas cooling and heating functions are needed for hydrodynamic galaxy simulations. We use machine learning to analyze atomic gas cooling and heating functions computed by Cloudy in the presence of a generalized incident local radiation field. We characterize the radiation field through binned radiation field intensities instead of the photoionization rates used in our previous work. We find a set of 6 energy bins whose intensities exhibit relatively low correlation. We use these bins as features to train machine learning models to predict Cloudy cooling and heating functions at fixed metallicity. We compare the relative SHapley Additive exPlanation (SHAP) value importance of the features. From the SHAP analysis, we identify a feature subset of 3 energy bins ($0.5-1, 1-4$, and $13-16 \, \mathrm{Ry}$) with the largest importance and train additional models on this subset. We compare the mean squared errors and distribution of errors on both the entire training data table and a randomly selected 20% test set withheld from model training. The machine learning models trained with 3 and 6 bins, as well as 3 and 4 photoionization rates, have comparable accuracy everywhere, with errors $\gtrsim 10$ times smaller than for the interpolation table of Gnedin and Hollon (2012). We conclude that 3 energy bins (or 3 analogous photoionization rates: molecular hydrogen photodissociation, neutral hydrogen HI, and fully ionized carbon CVI) are sufficient to characterize the dependence of the gas cooling and heating functions on our assumed incident radiation field model.

79 ASTRONOMY AND ASTROPHYSICS↗

Heat pipe cooled rocket engines

A concept for a heat-pipe-cooled rocket engine, which involves the use of heat pipes to augment radiation cooling on small, low-flux rocket engines used for attitude control and stationkeeping on satellites, is discussed. Results of the thermal and performance analyses performed on a prototype heat cooled thrust chamber are presented, together with the results of fabrication experiments. A test plan for full-scale hot fire hardware testing is outlined.

Berkman, D. K.↗

Metal foam heat exchangers for air and gas cooling and heating applications

Improved heat exchangers according to several embodiments are provided. The heat exchangers provide improved heat transfer for air flow in wet and dry operating conditions, while minimizing pressure drop across the heat exchanger in some applications. According to one embodiment, an improved heat exchanger includes a plurality of metal foam fins between adjacent heat exchange conduits, the heat exchange conduits being arranged parallel to each other to define parallel flow paths between an inlet header and an outlet header. The metal foam fins occupy a cross-flow region between adjacent conduits, the fins having a fixed angular orientation or being rotatable in unison to vary the thermal capacitance of the heat exchanger.

Nawaz, Kashif↗

The Impact of Neutron Transfer Reactions on the Heating and Cooling of Accreted Neutron Star Crusts

Abstract Nuclear reactions heat and cool the crust of accreting neutron stars and need to be understood to interpret observations of X-ray bursts and long-term cooling in transiently accreting systems. It was recently suggested that previously ignored neutron transfer reactions may play a significant role in the nuclear processes. We present results from full nuclear network calculations that now include these reactions and determine their impact on crust composition, crust impurity, heating, and cooling. We find that a large number of neutron transfer reactions indeed occur and impact crust models. In particular, we identify a new type of reaction cycle that brings a pair of nuclei across the nuclear chart into equilibrium via alternating neutron capture and neutron release, interspersed with a neutron transfer. While neutron transfer reactions lead to changes in crust model predictions and need to be considered in future studies, previous conclusions concerning heating, cooling, and compositional evolution are remarkably robust.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Control development and sizing analysis for a 5th generation district heating and cooling network using Modelica

5th generation district heating and cooling system (5GDHC) are a relatively new concept. They use a single district loop near ambient temperature to provide heating and cooling. This paper improves on the modelling and control of a 5GDHC system called the reservoir network. The study updates the sewage heat exchanger plant model to more realistically represent seasonal changes, uses refined pump models with variable efficiency, introduces a ground coupled district pipe model to consider the inertia of the district network and implements a new control strategy for geothermal storage and sewage heat exchanger. The new approach reduced operating costs, mainly due to pumping cost for storage, sewage heat exchanger plant and distribution pump, while increasing the overall robustness of the approach in different sizing conditions. Thanks to the new controller, the pumping consumption was reduced by 21% with respect to the original baseline. Furthermore, the new control makes the system take better advantage of design changes, when reducing borehole field size and increasing the sewage heat exchanger size, the pumping energy savings become 29% with respect to the original baseline. Lastly, borehole field temperature stability was analyzed through 40 years of simulation.

Zanetti, Ettore↗