Engineering PapersSearch

SEARCH · Engineering Papers

Results for “heat pump, ductless heat pump, heating, cooling, high efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,608 records · Page 4

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Nuclear Safety [Vol. 29, No. 1, January-March 1988]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. THE CHERNOBYL ACCIDENT: 1 Core History and Nuclide Inventory of the Chernobyl Core at the Time of Accident by Gerald Kirchner and Cornelius C. Noack; GENERAL SAFETY CONSIDERATIONS: 6 Nonprescriptive Nuclear Safety Regulation: The Example of Loss of Offsite Power by M. W. Golay, V. P. Manno, and C. Vlahoplus, Jr., 20 Nuclear Power Safety Goals in Light of the Chernobyl Accident by C. Whipple and C. Starr; ACCIDENT ANALYSIS: 29 Containment Loads from Severe Accidents—U.S. Program by W. Kerr and M. K. Dey; PLANT SAFETY FEATURES: 36 Safety Characteristics of Modern High-Temperature Reactors: Focus on German Designs by W. Kröger, H. Nickel, and R. Schulten; ENVIRONMENTAL EFFECTS: 49 Radiation Hormesis and Nuclear Safety by C. C. Congdon; OPERATING EXPERIENCES: 58 Evaluation of Nonradiological Water Chemistry at Power Reactors by Harvey Zibulsky, James J. Kottan, Walter J. Pasciak, Mary Ann Castrogivanni, and Sujit Banerjee, 64 Reactor Shutdown Experience Compiled by J. W. Cletcher, 67 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 85 General Administrative Activities Compiled by E. G. Silver, 94 Reports, Standards, and Safety Guides by D. S. Queener, 100 Status of Power-Reactor Projects Undergoing Licensing Review Compiled by E. G. Silver, 103 Proposed Rule Changes as of Sept. 30, 1987; ANNOUNCEMENTS: 5 Northwestern University Short Course on Radiation Safety, 28 International Approach to Nuclear Safety (After Three-Mile Island and Chernobyl), 57 RPI Short Course on Modern Developments in Boiling Heat Transfer and Two-Phase Flow, 107 20th DOE/NRC Nuclear Air Cleaning Conference, 110 Third International Topical Meeting on Nuclear Power Plant Thermal Hydraulics and Operations, 108 The Authors, 111 Indexes to Nuclear Safety, Volume 28.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH 2 ). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH 2 temperatures (20.3 – 24.2 K), pressures (100 – 350 kPa), and flow rates (0.010 – 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

Fuel Depot

Solar Heat for Industrial Processes: Integration with Chemical Reactors

The integration of solar thermal systems with chemical reactors has been proposed as part of a larger effort to develop and deploy solar heat for industrial processes (SHIP) technologies. A strong motivation for SHIP processes and technologies is the potential for high thermal efficiency coupled with low-cost thermal energy storage (TES) which can enable commercial deployment of such systems. While there are different ways to categorize SHIP technologies, one important such distinction is between directly irradiated systems and indirect off-sun process driven by a SHIP system. While directly irradiated systems can provide high thermal efficiencies and high fluxes, they usually require complex engineering solutions due to the need for redesigning the established processes and unit operations. In most cases, it is also more challenging to couple such a process to a TES system, losing some of the benefits of SHIP. On the other hand, using a SHIP system to drive an industrial process off-sun can allow better integration with existing process chains, easier TES capabilities, and potential for more applications fitting a specific SHIP technology. However, the integration of SHIP systems with the industrial processes is not fully explored in detail, especially in the case of high-temperature processes such as reforming, cracking, cement manufacturing, and iron/steelmaking. Many of these systems require heating fluxes of >50 kW/m^2, supplied via combustion of hydrocarbons in a fire box and benefitting from radiative heat transfer between the flue gases and the reaction zones. As such, using SHIP systems for such processes is more complex than providing the same thermal input in the form of a heat transfer medium (HTM) entering the reactor, kiln, or furnace. Moreover, in case convective heat transfer using SHIP is envisioned, for example using supercritical CO2 as the HTM from a particle receiver, the thermal integration might be more challenging than initially envisioned: lower heat transfer coefficients and limited approach temperature might require large flow rates, causing a mismatch between the process thermal requirements and the thermal capacity of the SHIP system. In addition, even if the heat exchange between SHIP and reactor is effective, there is still a cold leg HTM at the reaction temperature or slightly below it. Chemical plants usually include a set of heat exchangers, heat recovery steam generators, and even power generation units - in a tightly integrated design - to recover the flue gases which are eventually vented. With SHIP systems mostly operating on a closed HTM loop, bottoming the cold leg is crucial. In this talk, we will present different modeling results for a variety of syngas production reactions, using catalytic and chemical looping processes, and discuss some of the challenges and design considerations for off-sun chemical reactors using SHIP systems.

14 SOLAR ENERGY

Experimental Characterization of Additively Manufactured Nickel-Titanium Shape Memory Alloy Heat Pipes

Shape memory alloys (SMA) have been identified for use in spacecraft components as replacement for conventional deployment mechanisms. They may be used in thermal management components such as radiators to create self-deploying radiators. One SMA, NiTi, has also been developed for additive manufacturing processes. Heat pipes are a common way to create highly effective and lightweight spaceflight radiators, and heat pipes can also be made from NiTi and related alloys. The wick is the critical element of a functioning heat pipe, and recent progress over the past years has led to the development of additively manufactured heat pipe wicks in various materials. The combination of these efforts is the focus of this project: creating an additively manufactured, shape memory alloy self-deploying heat pipe radiator. This paper will focus on the experimental characterization of these additively manufactured NiTi heat pipes. The heat pipe coupons were additively manufactured by direct metal laser sintering (DMLS), with an integral liquid cooled condenser. Heat is input to the heat pipe via a thin film heater. Thermocouples were spot welded to the heat pipes to measure temperature at several axial locations. The heat pipes were tested with two working fluids: water and ethanol. Ethanol is not an ideal working fluid for heat pipes but is useful in characterizing them because it wets well to a wide variety of surfaces. Water is in general a superior working fluid for heat pipes, but its contact angle and therefore wicking performance strongly depends on the surface chemistry of the surface it is in contact with. A particular measurement of interest in this test is the evaporator to condenser thermal conductance, which will be compared in the full paper to recently published correlations for additively manufactured heat pipes. Experimental results for two straight geometry and one bellows geometry heat pipe will be presented. The bellows geometry is of interest for condenser of the self-deploying radiator design.

Additive manufacturing

Time evolution of a pumped molecular magnet—A time-resolved inelastic neutron scattering study

Introducing an experimental technique of time-resolved inelastic neutron scattering (TRINS), we explore the time-dependent effects of resonant pulsed microwaves on the molecular magnet Cr 8 F 8 Piv 16 . The octagonal rings of magnetic Cr 3+ atoms with antiferromagnetic interactions form a singlet ground state with a weakly split triplet of excitations at 0.8 meV. A 4.6 tesla field was applied to tune the splitting between two members of the triplet excited level |1$\rangle$ ↔ |2$\rangle$ to resonance with 105 GHz (0.434 meV) microwaves. The time-dependent occupations of the ground state |0$\rangle$, lower lying levels |1$\rangle$ and |2$\rangle$, and higher energy states |λ ≥ 3$\rangle$ were extracted during and after 20 s long microwave pulses incident along the (101) direction of a Cr 8 F 8 Piv 16 crystal held at 1.9 K. At significantly elevated spin temperatures, we found underpopulation relative to thermal equilibrium of |2$\rangle$ and spin-lattice thermalization time scales ranging from 1.6(2) s to 5.7(2) s depending on the power level. This contrasts with the relaxation time τ 1 (T → 0) = 27(5) 𝛍 s inferred for |2$\rangle$ from in situ Electron Spin Resonance measurements. By probing a broad range of excited states during intense microwave pumping, TRINS thus provides a first view of long lived excited states in a molecular antiferromagnet.

Science & Technology - Other Topics

A Comparison of Doppler Lidar Wind Sensors for Earth-Orbit Global Measurement Applications

Now, there are four Doppler lidar configurations which are being promoted for the measurement of tropospheric winds: (1) the coherent CO2 Lidar, operating in the 9 micrometer region using a pulsed, atmospheric pressure CO2 gas discharge laser transmitter, and heterodyne detection; (2) the coherent Neodymium doped YAG or Glass Lidar, operating at 1.06 micrometers, using flashlamp or diode laser optical pumping of the solid state laser medium, and heterodyne detection; (3) the Neodymium doped YAG/Glass Lidar, operating at the doubled frequency (at 530 nm wavelength), again using flashlamp or diode laser pumping of the laser transmitter, and using a high resolution tandem Fabry-Perot filter and direct detection; and (4) the Raman shifted Xenon Chloride Lidar, operating at 350 nm wavelength, using a pulsed, atmospheric pressure XeCl gas discharge laser transmitter at 308 nm, Raman shifted in a high pressure hydrogen cell to 350 nm in order to avoid strong stratospheric ozone absorption, also using a high resolution tandem Fabry-Perot filter and direct detection. Comparisons of these four systems can include many factors and tradeoffs. The major portion of this comparison is devoted to efficiency. Efficiency comparisons are made by estimating the number of transmitted photons required for a single pulse wind velocity estimate of + or - 1 m/s accuracy in the middle troposphere, from an altitude of 800 km, which is assured to be reasonable for a polar orbiting platform.

Robert T Menzies

Tracing Phase Transformation and Lattice Evolution in a TRIP Sheet Steel under High-Temperature Annealing by Real-Time In Situ Neutron Diffraction

Real-time in situ neutron diffraction was used to characterize the crystal structure evolution in a transformation-induced plasticity (TRIP) sheet steel during annealing up to 1000 °C and then cooling to 60 °C. Based on the results of full-pattern Rietveld refinement, critical temperature regions were determined in which the transformations of retained austenite to ferrite and ferrite to high-temperature austenite during heating and the transformation of austenite to ferrite during cooling occurred, respectively. The phase-specific lattice variation with temperature was further analyzed to comprehensively understand the role of carbon diffusion in accordance with phase transformation, which also shed light on the determination of internal stress in retained austenite. These results prove the technique of real-time in situ neutron diffraction as a powerful tool for heat treatment design of novel metallic materials.

Yu, Dunji [ORNL] (ORCID:0000000189467851)

Tensorized Interior Radiative Heat Transfer for a Scalable and Calibrated Building Energy Simulator

Building energy simulation is a critical tool for developing and testing advanced control strategies, such as Reinforcement Learning (RL), to provide demand flexibility and affordable energy costs. The recently introduced Smart Buildings Control Suite (sbsim) provides a lightweight, scalable, and data-calibrated simulation environment based on a 2D finite-difference model. However, the initial model primarily focused on conductive and convective heat transfer, neglecting the significant impact of long-wave radiative heat exchange between interior surfaces. This paper presents a significant extension to the sbsim framework by incorporating a physically-grounded model for interior radiative heat transfer. Our primary contribution is the development and integration of a fully tensorized radiative heat transfer module, which preserves the computational efficiency and scalability of the original simulator. This was achieved by developing a pipeline for view factor calculation, including an algorithm to identify directly seeing surfaces within complex floor plans, and formulating the net radiation equations for efficient execution on modern hardware accelerators. We validate the numerical accuracy of our tensorized implementation by comparing its results against a traditional iterative approach, demonstrating identical outcomes. This enhancement increases the physical fidelity of sbsim, enabling more accurate training of RL agents for building energy optimization.

Ham, Sang woo

Demonstration of gold nanorod systems for enhanced total efficiency: Experimental and numerical analysis

This study investigates the photothermal performance of gold nanorods engineered to exhibit longitudinal plasmon resonances at 695 nm, 780 nm, and 970 nm. The work combines synthesis, structural characterization, extinction measurements, numerical modeling, and controlled temperature experiments to quantify how nanorod geometry, resonance tuning, concentration, and chamber shape jointly influence heat generation. Transmission electron microscopy confirms that increasing nanorod aspect ratio systematically shifts the longitudinal plasmon peak toward the near-infrared region. Extinction measurements show strong agreement with theoretical predictions, validating the numerical model across two independent datasets. Three chamber geometries were tested under laser excitation at 640 nm, 808 nm, and 980 nm: an ascending stepped base, a flat base, and a descending stepped base. Without nanorods, the ascending geometry produced the highest efficiency due to enhanced natural convection. After introducing gold nanorods, all geometries exhibited substantial thermal enhancement, with total efficiencies exceeding 20%. The strongest improvement was obtained for nanorods resonant at 780 nm with a mass concentration of 4.6 mg/mL implemented on the descending stepped-base geometry. This performance resulted from the combined effect of spectral overlapping with the 808 nm laser, the highest nanorod concentration, and localized heat accumulation that intensified buoyancy-driven flow. The findings demonstrate that total efficiency is governed by a synergistic interplay between optical resonance, nanoparticle concentration, and macroscopic chamber design, revealing the system-level coupling between nanoscale plasmonic absorption and macroscale heat-transfer phenomena. The results provide a validated framework for tuning nanoscale plasmonic absorbers and optimizing thermal systems for applications requiring efficient light-to-heat conversion.

77 NANOSCIENCE AND NANOTECHNOLOGY

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

On the Stability Analysis of Astrophysical Cooling Functions

To model the temperature evolution of optically thin astrophysical environments at MHD scales, radiative and collisional cooling rates are typically either pretabulated or fit into a functional form and then input into MHD codes as a radiative loss function. Thermal balance requires estimates of the analogous heating rates, which are harder to calculate, and due to uncertainties in the underlying dissipative heating processes these rates are often simply parameterized. The resulting net cooling function defines an equilibrium curve that varies with density and temperature. Such cooling functions can make the gas prone to thermal instability (TI), which will cause departures from equilibrium. There has been no systematic study of thermally unstable parameter space for nonequilibrium states. Motivated by our recent finding that there is a related linear instability, catastrophic cooling instability, that can dominate over TI, here we carry out such a study. We show that Balbus instability criteria for TI can be used to define a critical cooling rate, Λc, that permits a nonequilibrium analysis of cooling functions through the mapping of TI zones. We furthermore illustrate how thermal conduction modifies the shape of TI zones. Upon applying a Λc-based stability analysis to coronal loop simulations, we find that loops undergoing periodic episodes of coronal rain formation are linearly unstable to catastrophic cooling instability, while TI is stabilized by thermal conduction.

Amanda Stricklan

Heat Transfer Fluids as Co‐Diluents in Localized High‐Concentration Electrolytes for High‐Rate Lithium Metal Batteries With Enhanced Safety

Localized high-concentration electrolytes (LHCEs) have been identified as promising electrolyte formulations for lithium metal batteries, due to their effective interphase formation and promotion of compact Li deposition, yet their practical implementation is often limited by reduced ion transport kinetics. In this study, two industrially established fluorinated ethers are identified for the first time in battery research as effective co-diluents as they combine a broad electrochemical stability window with a low viscosity and intrinsic non-flammability. Incorporating these components, commonly used as heat transfer fluids, yields safer, less flammable electrolyte formulations with enhanced ion mobilities. In particular, the ternary co-diluent formulation shows improved ion mobility by reducing the electrolyte's viscosity while limiting excessive ion clustering. Based on the improved electrolyte transport kinetics, lower overvoltages and higher Coulombic efficiencies at current densities ≥ 1 mA cm −2 are achieved with the ternary co-diluent blend, resulting in markedly extended cycle life in an application-oriented zero-excess pouch cell compared with the baseline system. Complementary electrochemical and ex situ analysis of harvested electrodes at moderate current densities reveals no discernible differences in interphase morphology and composition, suggesting enhanced ion mobility as the primary cause of the improved high-rate performance.

electrolyte diluent

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling