Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hardness assurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comparison of a Probabilistic TID Hardness Assurance Method to Military Standards

The rapid evolution of electronics has heralded countless benefits to humanity, enabling increases in computing power while decreasing costs. However, the constantly changing semiconductor device landscape proves to be an immense challenge for the reliability community, especially for those concerned with radiation effects on microelectronics. Changes in device manufacturing, from device structure to processing steps, may and often do change the way the device responds to radiation. While radiation hardened parts are not as much of a reliability concern, they also lag behind commercial off-the-shelf, or COTS, parts in terms of computing capabilities, some by over a decade. Many missions may have no choice but to utilize COTS. As such, these missions need to ensure their parts are reliable in the face of total ionizing dose (TID). However, part and testing facility costs limit the amount of testing possible.

Chloe Champagne↗

Instructions for Plastic Encapsulated Microcircuit(PEM) Selection, Screening and Qualification.

The use of Plastic Encapsulated Microcircuits (PEMs) is permitted on NASA Goddard Space Flight Center (GSFC) spaceflight applications, provided each use is thoroughly evaluated for thermal, mechanical, and radiation implications of the specific application and found to meet mission requirements. PEMs shall be selected for their functional advantage and availability, not for cost saving; the steps necessary to ensure reliability usually negate any initial apparent cost advantage. A PEM shall not be substituted for a form, fit and functional equivalent, high reliability, hermetic device in spaceflight applications. Due to the rapid change in wafer-level designs typical of commercial parts and the unknown traceability between packaging lots and wafer lots, lot specific testing is required for PEMs, unless specifically excepted by the Mission Assurance Requirements (MAR) for the project. Lot specific qualification, screening, radiation hardness assurance analysis and/or testing, shall be consistent with the required reliability level as defined in the MAR. Developers proposing to use PEMs shall address the following items in their Performance Assurance Implementation Plan: source selection (manufacturers and distributors), storage conditions for all stages of use, packing, shipping and handling, electrostatic discharge (ESD), screening and qualification testing, derating, radiation hardness assurance, test house selection and control, data collection and retention.

King, Terry↗

Annual Conference on Nuclear and Space Radiation Effects, 14th, College of William and Mary, Williamsburg, Va., July 12-15, 1977, Proceedings

Topics related to processing and hardness assurance are considered, taking into account the radiation hardening of CMOS technologies, technological advances in the manufacture of radiation-hardened CMOS integrated circuits, CMOS hardness assurance through process controls and optimized design procedures, the application of operational amplifiers to hardened systems, a hard off-the-shelf SG1524 pulse width modulator, and the gamma-induced voltage breakdown anomaly in a Schottky diode. Basic mechanisms are examined, giving attention to chemical and structural aspects of the irradiation behavior of SiO2 films on silicon, experimental observations of the chemistry of the SiO2/Si interface, leakage current phenomena in irradiated SOS devices, the avalanche injection of holes into SiO2, the low-temperature radiation response of Al2O3 gate insulators, and neutron damage mechanisms in silicon at 10 K. Other subjects discussed are related to radiation effects in devices and circuits, space radiation effects, and aspects of simulation, energy deposition, and dosimetry.

Stahl, R. H.↗

Understanding how molecular hydrogen impacts the total dose and dose rate response of linear bipolar circuits

Recent Enhanced Low Dose Rate Sensitivity (ELDRS) investigations carried out by RLP Research, Arizona State University (ASU) and Jet Propulsion Laboratory (JPL) have shown significant differences in the degradation of bipolar micro-circuits with total dose in the presence of molecular hydrogen (H2) in packages. This has a significant impact on radiation hardness assurance and opens up opportunities to improve device performance. The general objectives of this program are to: 1. Determine the extent to which hydrogen contamination affects the total dose and dose rate response of linear bipolar circuits; 2. Develop a model that will enable the prediction of high dose rate (HDR) and low dose rate (LDR) response asymptotes and transition dose rates as a function of total dose, temperature, pressurized hydrogen, defect precursors, and other process dependent variables; 3. Explore the possibility of an accelerated hardness assurance method and possible hardening approaches; and 4. Extend the work to other technologies that have total dose response affected by hydrogen contamination.In this document, we xperimentally demonstrate with test transistors and circuits that hydrogen is correlated with ELDRS in bipolar linear circuits. We show that the amount of hydrogen determines: 1) the total dose response versus dose rate and 2) the transition dose rates between the high and low dose rate responses. The experimental results are supported with a steady state drift/diffusion analytical model as well as modeling calculations using COMSOL Multiphysics.

Pease, Ron↗

Board Level Proton Testing Book of Knowledge for NASA Electronic Parts and Packaging Program

This book of knowledge (BoK) provides a critical review of the benefits and difficulties associated with using proton irradiation as a means of exploring the radiation hardness of commercial-off-the-shelf (COTS) systems. This work was developed for the NASA Electronic Parts and Packaging (NEPP) Board Level Testing for the COTS task. The fundamental findings of this BoK are the following. The board-level test method can reduce the worst case estimate for a board's single-event effect (SEE) sensitivity compared to the case of no test data, but only by a factor of ten. The estimated worst case rate of failure for untested boards is about 0.1 SEE/board-day. By employing the use of protons with energies near or above 200 MeV, this rate can be safely reduced to 0.01 SEE/board-day, with only those SEEs with deep charge collection mechanisms rising this high. For general SEEs, such as static random-access memory (SRAM) upsets, single-event transients (SETs), single-event gate ruptures (SEGRs), and similar cases where the relevant charge collection depth is less than 10 μm, the worst case rate for SEE is below 0.001 SEE/board-day. Note that these bounds assume that no SEEs are observed during testing. When SEEs are observed during testing, the board-level test method can establish a reliable event rate in some orbits, though all established rates will be at or above 0.001 SEE/board-day. The board-level test approach we explore has picked up support as a radiation hardness assurance technique over the last twenty years. The approach originally was used to provide a very limited verification of the suitability of low cost assemblies to be used in the very benign environment of the International Space Station (ISS), in limited reliability applications. Recently the method has been gaining popularity as a way to establish a minimum level of SEE performance of systems that require somewhat higher reliability performance than previous applications. This sort of application of the method suggests a critical analysis of the method is in order. This is also of current consideration because the primary facility used for this type of work, the Indiana University Cyclotron Facility (IUCF) (also known as the Integrated Science and Technology (ISAT) hall), has closed permanently, and the future selection of alternate test facilities is critically important. This document reviews the main theoretical work on proton testing of assemblies over the last twenty years. It augments this with review of reported data generated from the method and other data that applies to the limitations of the proton board-level test approach. When protons are incident on a system for test they can produce spallation reactions. From these reactions, secondary particles with linear energy transfers (LETs) significantly higher than the incident protons can be produced. These secondary particles, together with the protons, can simulate a subset of the space environment for particles capable of inducing single event effects (SEEs). The proton board-level test approach has been used to bound SEE rates, establishing a maximum possible SEE rate that a test article may exhibit in space. This bound is not particularly useful in many cases because the bound is quite loose. We discuss the established limit that the proton board-level test approach leaves us with. The remaining possible SEE rates may be as high as one per ten years for most devices. The situation is actually more problematic for many SEE types with deep charge collection. In cases with these SEEs, the limits set by the proton board-level test can be on the order of one per 100 days. Because of the limited nature of the bounds established by proton testing alone, it is possible that tested devices will have actual SEE sensitivity that is very low (e.g., fewer than one event in 1 × 10(exp 4) years), but the test method will only be able to establish the limits indicated above. This BoK further examines other benefits of proton board-level testing besides hardness assurance. The primary alternate use is the injection of errors. Error injection, or fault injection, is something that is often done in a simulation environment. But the proton beam has the benefit of injecting the majority of actual SEEs without risk of something being missed, and without the risk of simulation artifacts misleading the SEE investigation.

Guertin, Steven M.↗

Model-Based Radiation Assurance for Satellites with Commercial Parts

Presents a methodology for modeling radiation hardness assurance activities into MBSE throughout the NASA project life cycle. Also includes information about quantitatively and qualitatively modeling radiation-induced failures with system models.

Radiation Hardness Assurance↗

A Confidence-Based Approach to Including Survivors in a Probabilistic TID Failure Assessment

A probabilistic total ionizing dose (TID) failure assessment is extended to include survivor data, enabling the bounding of failure probability to a desired confidence level (CL) without failure data. The extension provides an avenue for analyzing microelectronics tested for TID without reaching a failure mode, a scenario often encountered by missions utilizing commercial-off-the-shelf (COTS) technologies. Using the type-I censored likelihood formulation and a realistic upper bound on expected device performance, the failure probability space is bounded by confidence contours within the context of a variable environment. The framework accommodates any type of distribution assumed for the part failure or the environment under consideration. Furthermore, the framework can be utilized pre-emptively to plan future device TID tests, minimizing costs while meeting survival requirements. Heritage data may also be used as survivors to further minimize testing costs when parts are from the same lot, but the amount of constraint derived from heritage is limited. Altogether, the framework enables a formal, mathematically rigorous analysis of radiation tolerant devices tested to a maximum dose, as well as flight heritage, in a hardness assurance methodology.

confidence↗

A CubeSat-Payload Radiation-Reliability Assurance Case using Goal Structuring Notation

CubeSats have become an attractive platform for universities, industry, and government space missions because they are cheaper and quicker to develop than full-scale satellites. One way CubeSats keep costs low is by using commercial off-the-shelf parts (COTS) instead of space-qualified parts. Space-qualified parts are often costlier, larger, and consume more power than their commercial counterparts precluding their use within the CubeSat form-factor. Given typical power budgets, monetary budgets, and timelines for CubeSat missions, conventional radiation hardness assurance, like the use of space-qualified parts and radiation testing campaigns of COTS parts, is not practical. Instead, a system-level approach to radiation effects mitigation is needed. In this paper an assurance case for a system-level approach to mitigate radiation effects of a CubeSat science experiment is expressed using Goal Structuring Notation (GSN), a graphical argument standard. The case specifically looks at three main mitigation strategies for the radiation environment: total ionizing dose (TID) screening of parts, detection and recovery from single-event latch-ups (SEL) and single-event functional interrupts (SEFI). The graphical assurance case presented makes a qualitative argument for the radiation reliability of the CubeSat experiment using part and system-level mitigation strategies.

COTS↗

Confidence Level Based Approach to Total Dose Specification for Spacecraft Electronics

A confidence level based approach to total dose radiation hardness assurance is presented for spacecraft electronics. It is applicable to both ionizing and displacement damage dose. Results are compared to the traditional approach that uses radiation design margin and advantages of the new approach are discussed.

Total Dose Distributions in Space↗

Recent Advances and Future Challenges in Risk-Based Radiation Engineering

We cover a top-level introduction to hardness assurance (HA) from a robotic space system perspective, starting at the piece-part level. We discuss error sources inherent to presently-accepted HA practices and why they cause us to be risk-averse. We conclude by reviewing current proposals that move towards more risk-tolerant system design approaches as well as future challenges that will require these advanced techniques.

radiation effects↗

R-Gentic-SEAM Interface and Harmonization

SEAM is a useful resource for model-based radiation hardness assurance but can be technically challenging for new users. R-Gentic is a NASA developed website that aims at assisting engineers better understand the radiation concerns in their EEE parts. This work aims at providing an update on an ongoing effort to interface R-Gentic with SEAM. Once integration is completed, R-Gentic can be used to seed new SEAM projects, making project creation easier and more accessible.

Procedures↗

Radiation Assurance for the Space Environment

The space radiation environment can lead to extremely harsh operating conditions for spacecraft electronic systems. A hardness assurance methodology must be followed to assure that the space radiation environment does not compromise the functionality and performance of space-based systems during the mission lifetime. The methodology includes a definition of the radiation environment, assessment of the radiation sensitivity of parts, worst-case analysis of the impact of radiation effects, and part acceptance decisions which are likely to include mitigation measures.

Barth, Janet L.↗

Solid State Drive Radiation Assurance With Active Testing

Automotive and industrial grade SSDs were tested for TID and SEE response at the assembly level to investigate radiation tolerance trends and explore radiation hardness assurance best practices in commercial memory devices. SSDs were installed in passive NVMe extenders to place only the drive in the beam line. A digital I/O module connected to the test computer provided inhibit signals to block both facility beam delivery and power while attempting recovery from any device failure conditions (e.g., failed write, failed read, or unresponsive device).

Edward P Wilcox↗