Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

PLOT3D user's manual

PLOT3D is a computer graphics program designed to visualize the grids and solutions of computational fluid dynamics. Seventy-four functions are available. Versions are available for many systems. PLOT3D can handle multiple grids with a million or more grid points, and can produce varieties of model renderings, such as wireframe or flat shaded. Output from PLOT3D can be used in animation programs. The first part of this manual is a tutorial that takes the reader, keystroke by keystroke, through a PLOT3D session. The second part of the manual contains reference chapters, including the helpfile, data file formats, advice on changing PLOT3D, and sample command files.

Walatka, Pamela P.↗

Toward Relating Open- and Closed-Test Section Microphone Phased Array Aeroacoustic Measurements

Aeroacoustic measurements utilizing microphone phased arrays are becoming more commonplace in large-scale wind tunnels. However, for such costly tests it is difficult to assess the influence of a given facility's configuration on the acquired data. One such opportunity has recently arisen in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel, where the High-Lift configuration of the Common Research Model was tested in both open-jet and closed wall configurations. Acoustic data were acquired on the same model with the same specific hardware at the same Mach number; and for similar model angles of attack, array apertures, and array angles relative to the model location. Initial deconvolution comparisons using DAMAS appear poor. The closed test section results show contamination likely due to background noise and reflections. The open-jet results show severe blurring due to the decorrelation of acoustic waves passing through a turbulent free shear layer. However, accounting for image sources in the DAMAS grid reduces visual artifacts in the closed test section results, and a preliminary coherence correction technique mitigates the blurring in the open-jet results. Qualitatively, both tests identify similar source behavior. Quantitatively, summed spectra of the slat noise agree in some frequency bands but differ in others. Proposals that may mitigate the difference are given for each configuration, such as correcting for the array protective cover and applying background subtraction in the closed wall configuration, and further developing the coherence loss correction for deconvolution methods in the open-jet setup.

microphone array↗

A package for 3-D unstructured grid generation, finite-element flow solution and flow field visualization

A set of computer programs for 3-D unstructured grid generation, fluid flow calculations, and flow field visualization was developed. The grid generation program, called VGRID3D, generates grids over complex configurations using the advancing front method. In this method, the point and element generation is accomplished simultaneously, VPLOT3D is an interactive, menudriven pre- and post-processor graphics program for interpolation and display of unstructured grid data. The flow solver, VFLOW3D, is an Euler equation solver based on an explicit, two-step, Taylor-Galerkin algorithm which uses the Flux Corrected Transport (FCT) concept for a wriggle-free solution. Using these programs, increasingly complex 3-D configurations of interest to aerospace community were gridded including a complete Space Transportation System comprised of the space-shuttle orbitor, the solid-rocket boosters, and the external tank. Flow solutions were obtained on various configurations in subsonic, transonic, and supersonic flow regimes.

Parikh, Paresh↗

Structure- and Physics-Preserving Reductions of Power Grid Models

The large size of multiscale, distribution and transmission, power grids hinders fast systemwide estimation and real-time control and optimization of operations. This paper studies graph reduction methods of power grids that are favorable for fast simulations and follow-up applications. While the classical Kron reduction has been successful in reduced order modeling of power grids with traditional, hierarchical design, the selection of reference nodes for the reduced model in a multiscale, distribution and transmission, network becomes ambiguous. In this work we extend the use of the iterative Kron reduction by utilizing the electric grid's graph topology for the selection of reference nodes, consistent with the design features of multiscale networks. Additionally, we propose further reductions by aggregation of coherent subnetworks of triangular meshes, based on the graph topology and network characteristics, in order to preserve currents and build another power-flow equivalent network. Our reductions are achieved through the use of iterative aggregation of subgraphs that include general tree structures, lines, and triangles. Important features of our reduction algorithms include that (i) the reductions are either equivalent to the Kron reduction or otherwise produce a power-flow equivalent network; (ii) due to the mentioned power-flow equivalence, the reduced network can model the dynamic of the swing equations for a lossless, inductive, steady state network; (iii) the algorithms efficiently utilize hash tables to store the sequential reduction steps. The third feature allows for easy reintroduction of detailed models into the reduced, conceptual network and makes the final reduced order model backward compatible with a sequence of intermediate, partially reduced networks with varying resolution---the ordered sequence of iterative reductions corresponds to a sequence of reduced order models. The performance of our graph reduction algorithms and features of the reduced grids are discussed on a real-word transmission and distribution grid. We produce visualizations of the reduced models through open source libraries and release our reduction algorithms with example code and toy data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TU-H-206-07: Assessment of Geometric Distortion in EPI with a SPAMM Tagged Acquisition

Purpose: Echo planar imaging (EPI) is known to exhibit gross geometric distortion caused by multiple factors, including B0 inhomgeneity and transient eddy currents. However, diffusion weighted (DW) EPI has become indispensable for diagnosis and therapy assessment. We propose a methodology for quantifying distortion in EPI sequences that does not require the use of dedicated spatial accuracy phantoms, enabling flexibility in phantom design for QA of distortion effects in EPI protocols. Methods: The proposed methodology utilizes a saturation technique known as Spatial Modulation of Magnetization (SPAMM) that tags the imaging subject with saturated grid lines. Originally intended for tracking cardiac motion, these grids are applied to assess differences between diffusion weighting directions and b-values, or against a more geometrically robust sequence such as fast spin echo (FSE). The saturation preparation sequence consists of binomially weighted (e.g. 1-3-3-1) pulses interleaved with gradient blips along the frequency encode direction, followed by the same sequence with gradient blips in the phase encode direction. Three phantoms were assessed with these sequences: a spherical head-sized phantom, a large shimming phantom, and a modified PET ACR phantom that included compartments of water, air, oil, and Teflon. Each phantom was acquired with three sequences using parameters from a clinically appropriate protocol (22 cm head or 46 cm abdomen): a conventional DW-EPI sequence (3 DW directions), and both the DW-EPI and FSE sequences with tagging. Differences in grid locations were visualized with minimum intensity projection between images, and measured using intersecting locations on the grids. Results: Grid lines were clearly visualized on tagged images and enabled quantification of distortions. Maximum eddy current induced errors of 10.8 to 14.8 mm were observed in areas away from isocenter with DW gradients applied in various directions. Conclusion: SPAMM tagging provides a promising mechanism for assessing spatial distribution of distortion in EPI sequences.

60 APPLIED LIFE SCIENCES↗

Fast algorithms for visualizing fluid motion in steady flow on unstructured grids

The plotting of streamlines is an effective way of visualizing fluid motion in steady flows. Additional information about the flowfield, such as local rotation and expansion, can be shown by drawing in the form of a ribbon or tube. In this paper, we present efficient algorithms for the construction of streamlines, streamribbons and streamtubes on unstructured grids. A specialized version of the Runge-Kutta method has been developed to speed up the integration of particle paths. We have also derived closed-form solutions for calculating angular rotation rate and radius to construct streamribbons and streamtubes, respectively. According to our analysis and test results, these formulations are two to four times better in performance than previous numerical methods. As a large number of traces are calculated, the improved performance could be significant.

Ueng, S. K.↗

Ocular Outcomes Comparison Between 14- and 70-day Head-down Tilt Bed Rest

INTRODUCTION: Ophthalmological changes, including optic disc edema with optic nerve sheath distension, posterior globe flattening with hyperopic shift, choroidal folds and cotton wool spots have been detected in some astronauts involved in long-duration spaceflights. (sup 1) It is hypothesized that elevated intracranial pressure resulting from microgravity-induced cephalad fluid shifts may be responsible for most of these findings. Head-down tilt bed rest (HTDBR) is a ground-based microgravity analog which also produces cephalad fluid shifts. It is conceivable that prolonged HDTBR exposure may induce ocular changes similar to those experienced in microgravity. Therefore, the purpose of the present study was to compare structural and functional ocular outcomes between 14- and 70-day HDTBR in healthy human subjects. It is hypothesized that 70-d HDTBR induced ocular changes of greater magnitude as compared to 14-d HDTBR. METHODS: Two HDTBR studies were conducted at the NASA Flight Analogs Research Unit, located at The University of Texas Medical Branch at Galveston, TX. Identical NASA standard screening procedures and BR conditions (e.g., strict sleep-wake cycle, standardized diet, continuous video monitoring) were implemented in both studies. Participants spent 14 and/or 70 consecutive days in a 6deg HDT position and did not engage in exercise. Subjects received weekly ocular examinations before, during, and after HDTBR. Ocular testing included: distance and near best-corrected visual acuity (BCVA), cycloplegic refraction, intraocular pressure (IOP) measurement, color vision, red dot test, modified Amsler grid test, confrontational visual field, color fundus photography and Spectral-domain OCT scans of the macula and the optic disc. Pre/post HDTBR differences between the two studies will be evaluated for BCVA, spherical equivalent, IOP, retinal nerve fiber layer (RNFL) thickness and macular OCT parameters. RESULTS: 16 (12 males and 4 females) and 6 (5 males and 1 female) subjects participated in the 14 and 70-day HDTBR studies, respectively. One subject participated in both studies. The demographic and ophthalmological characteristics of the 14-day HDTBR study have been presented elsewhere.2 In the 70- day study, subjects age averaged 39.5 +/- 7.8 years; pre- and post-HDTBR Goldmann IOP were, on average, 15.4 and 14.6 mmHg in the right eye, and 15.3 and 14.4 mmHg in the left eye, respectively; preand post-HDTBR Spectralis OCT (Heidelberg Engineering, GmbH, Heidelberg, Germany) average RNFL thickness were 103.8 and 106 μm in the right eye, and 103 and 104.3 μm in the left eye, respectively. In both studies, color vision, red dot test, modified Amsler grid test and confrontational visual field were within normal limits at all time points; no changes were detected on stereoscopic color optic disc photography. For the above outcomes, preliminary results of the pre/post HDTBR differences between the two studies will be presented at the 2015 Human Research Program Investigators' Workshop. CONCLUSIONS: Although 14-day HDTBR did not seem to induce clinically relevant ocular changes, (sup 2) a systematic evaluation and comparison with the 70-day HDTBR study results will elucidate whether the magnitude of ocular structural and functional changes is affected by the time spent in the recumbent position. Further research will also address the effects of integrated resistance and aerobic training during HDTBR on the ocular outcomes. REFERENCES: 1. Mader TH et al. Optic disc edema, globe flattening, choroidal folds, and hyperopic shifts observed in astronauts after long-duration space flight. Ophthalmology. 2011;118(10):2058-69. 2. Taibbi G et al. Ocular outcomes evaluation in a 14-day head-down bed rest study. Aviat Space Environ Med. 2014;85(10):983-92.

Cromwell, R.L.↗

A Review of Visualization Methods for Cyber-Physical Security: Smart Grid Case Study

Cyber-Physical Systems (CPSs) are becoming increasingly complex and interconnected as they attempt to meet the demands of evolving society. As a result, monitoring and maintaining them becomes a more complex and demanding task for control system operators and cyber defenders. While the literature on visualization techniques in the context of cybersecurity is extensive, the same cannot be said for studies on visualization for the security of cyber-physical systems. This paper aims to fill that gap by: 1) defining the main features of a visualizations workflow for security visualizations in cyber-physical systems. The workflow includes the acquisition of cyber and physical data, processing of data, selection, and configuration of both visualization tools and end-user interactions. 2) Providing an overview of cyber-physical security visualization systems, with a focus on smart grids as a case study. Finally, we use the perspectives gained from this analysis to provide insights and directions for future research and design of cyber-physical visualization techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

GRAPEVINE: Grids about anything by Poisson's equation in a visually interactive networking environment

A proven 3-D multiple-block elliptic grid generator, designed to run in 'batch mode' on a supercomputer, is improved by the creation of a modern graphical user interface (GUI) running on a workstation. The two parts are connected in real time by a network. The resultant system offers a significant speedup in the process of preparing and formatting input data and the ability to watch the grid solution converge by replotting the grid at each iteration step. The result is a reduction in user time and CPU time required to generate the grid and an enhanced understanding of the elliptic solution process. This software system, called GRAPEVINE, is described, and certain observations are made concerning the creation of such software.

Sorenson, Reese L.↗

The effect of perspective displays on altitude and stability control in simulated rotary wing flight

The effect of perspective displays on flight performance is investigated using two simulation experiments. In the first, a perspective grid display was superimposed on computer-generated terrain and subjects attempted to maintain their initial attitude in a simulated hover using terrain and/or one of four grid patterns. Horizontal lines produced the best attitude control performance. In the second experiment, a square grid was studied in combination with various visual display configurations and grid attachment conditions. It was found that performance with the panel-mounted display was significantly worse than with the out-the-window or helmet-mounted displays. The results suggested that the partial grid attachment condition improved hovering performance with the panel-mounted display.

O'Donnell, K. A.↗

Knowledge Discovery for Smart Grid Operation, Control, and Situation Awareness -- A Big Data Visualization Platform

In this paper, a big data visualization platform is designed to discover the hidden useful knowledge for smart grid (SG) operation, control and situation awareness. The spawn of smart sensors at both grid side and customer side can provide large volume of heterogeneous data that collect information in all time spectrums. Extracting useful knowledge from this big-data poll is still challenging. In this paper, the Apache Spark, an open source cluster computing framework, is used to process the big-data to effectively discover the hidden knowledge. A high-speed communication architecture utilizing the Open System Interconnection (OSI) model is designed to transmit the data to a visualization platform. This visualization platform uses Google Earth, a global geographic information system (GIS) to link the geological information with the SG knowledge and visualize the information in user defined fashion. The University of Denver's campus grid is used as a SG test bench and several demonstrations are presented for the proposed platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Contingency Visualization for Real-Time Decision Support in Grid Operation

Contingency analysis is a key function in control centers to assess the impact of various combinations of power system component failures based on state estimates. Today's practice analyzes only a limited set of contingency cases and lacks of capabilities in presenting the results in a way that is easy to be understood by grid operators in a short time frame of seconds to minutes. This limits the ability to operate the power grid for better reliability and efficiency. Faster analysis of more cases is required to safely and reliably operate today's power grids which have a less margin and more intermittent renewable energy sources. This paper explores the advancements in high performance computing and visual analytics for improving the computational speed and the information representation in contingency analysis. A framework of advanced contingency analysis is proposed. Case studies using the Western Electricity Coordinating Council (WECC) system are presented to demonstrate the feasibility of the proposed framework. Comparative assessment by real power grid operators has been performed as part of a WECC operator training class. The assessment results demonstrate the validity of the proposed contingency analysis and visualization approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Structural and Functional Ocular Outcomes Between 14- and 70 Day Bed Rest

Purpose: To compare structural and functional ocular outcomes in healthy human subjects undergoing 14- and/or 70-day head-down-tilt bed rest (HDTBR). We hypothesized the amount of HDTBR-induced ocular changes be affected by the HDTBR duration. Methods: The studies were conducted at the NASA Flight Analogs Research Unit, The University of Texas Medical Branch at Galveston, Galveston, TX. Participants were selected using NASA standard screening procedures. Standardized NASA screening procedures and bed rest conditions (e.g., strict sleep-wake cycle, standardized diet, continuous video monitoring) were implemented in both studies. Participants maintained a 6deg HDTBR position for 14 and/or 70 consecutive days and did not engage in exercise. Weekly ophthalmological examinations were conducted in the sitting (pre/post-bed rest only) and HDT positions. Ocular outcomes of interest included: near best-corrected visual acuity (BCVA); spherical equivalent, as determined by cycloplegic autorefraction; Goldmann applanation tonometry and iCare (Icare Finland Oy, Espoo, Finland) intraocular pressure (IOP) measurement; color vision; red dot test; modified Amsler grid test; confrontational visual field; stereoscopic color fundus photography; Spectralis OCT (Heidelberg Engineering, GmbH, Heidelberg, Germany) retinal nerve fiber layer thickness (RNFLT), peripapillary and macular retinal thicknesses. Mixed-effects linear models were used to compare pre- and post-HDTBR observations between 14- and 70-day HDTBR for our continuously scaled outcomes.

Cromwell, R. L.↗

Wireless Sensor Network for Electric Transmission Line Monitoring

Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and cost effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications. On such a platform, it has been demonstrated in this project that wireless monitoring units can effectively deliver real-time transmission line power flow information for less than $500 per monitor. The data delivered by such a monitor has during the course of the project been integrated with a national grid situational awareness visualization platform developed by Oak Ridge National Laboratory. Novel vibration energy scavenging methods based on piezoelectric cantilevers were also developed as a proposed method to power such monitors, with a goal of further cost reduction and large-scale deployment. Scavenging methods developed during the project resulted in 50% greater power output than conventional cantilever-based vibrational energy scavenging devices typically used to power smart sensor nodes. Lastly, enhanced and new methods for electromagnetic field sensing using multi-axis magnetometers and infrared reflectometry were investigated for potential monitoring applications in situations with a high density of power lines or high levels of background 60 Hz noise in order to isolate power lines of interest from other power lines in close proximity. The goal of this project was to investigate and demonstrate the feasibility of using small form factor, highly optimized, low cost, low power, non-contact, wireless electric transmission line monitors for delivery of real-time, independent power line monitoring for the US power grid. The project was divided into three main types of activity as follows; (1) Research into expanding the range of applications for non-contact power line monitoring to enable large scale low cost sensor network deployments (Tasks 1, 2); (2) Optimization of individual sensor hardware components to reduce size, cost and power consumption and testing in a pilot field study (Tasks 3,5); and (3) Demonstration of the feasibility of using the data from the network of power line monitors via a range of custom developed alerting and data visualization applications to deliver real-time information to federal agencies and others tasked with grid reliability (Tasks 6,8).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ramping and Uncertainty Prediction Tool - Analysis and Visualization of Wind Generation Impact on Electrical Grid

RUT software is designed for use by the Balancing Authorities to predict and display additional requirements caused by the variability and uncertainty in load and generation. The prediction is made for the next operating hours as well as for the next day. The tool predicts possible deficiencies in generation capability and ramping capability. This deficiency of balancing resources can cause serious risks to power system stability and also impact real-time market energy prices. The tool dynamically and adaptively correlates changing system conditions with the additional balancing needs triggered by the interplay between forecasted and actual load and output of variable resources. The assessment is performed using a specially developed probabilistic algorithm incorporating multiple sources of uncertainty including wind, solar and load forecast errors. The tool evaluates required generation for a worst case scenario, with a user-specified confidence level.

Etingov, Pavel↗