Rewarding Grid-Friendly Behavior: Estimating the Potential Bill Reduction and Load Shifting Benefits of Dynamic Prices

Shifting electric load from times of peak demand can be a key strategy to slow price growth as reducing peak demand avoids the cost of upgrading generation, transmission and distribution infrastructure. Utilities are releasing time-varying prices, such as time of use rates or dynamic prices, to incentivize grid-friendly load shifting. New dynamic price programs provide insight into the true cost of operating electricity grids and the potential economic benefits of load shifting. Program developers and device manufacturers need to understand the economic opportunities in terms of 1) the variation in prices across hours, days, and seasons; 2) the change in utility bills for customers who don’t shift load; and 3) the potential load shifted and economic value of different technologies if manufacturers or aggregators deploy price-responsive controls. This paper estimates possible impacts of dynamic price adoption and load shifting controls if customers paid the dynamic rate from one pilot program. Statistical analysis of historical prices identified annual and seasonal metrics as well as representative price curves for each circuit in the pilot. Simulations for residential technologies with price-responsive controls including unitary heat pump water heaters, central multifamily heat pump water heaters, heating & cooling + storage systems, and pool pumps estimated the potential impacts of highly dynamic prices both with and without load shifting controls. Results showed the potential to reduce electricity costs on representative days by 42-94% and reduce consumption during times of high electricity prices by 63-100% compared to baseline operation for those flex-friendly devices.

Grant, Peter↗

Duty cycle testing and performance evaluation of the SM-229 teleoperator

The first known experimental studies and analyses of teleoperator performance for specific duty cycles are discussed. The results are presented in two distinct areas as position usage patterns, and as three-dimensional power grids. The position usage patterns are a valuable means to assess the available motion range. The power grids are a unique concept for evaluating joint performance. Final conclusions contain recommendations to upgrade the teleoperator for optimum performance.

Stoughton, Robert S.↗

Data Assimilation Office (DAO) Operational Analyses and Reanalyses for Coordinated Enhanced Observing Period (CEOP)

The DAO operational assimilation system has produced and archived gridded data since 1998, and will continue through the CEOP period. However, major system upgrades and new assimilation variables will significantly affect the surface energy balance and data product. These changes will be discussed and the prospects for a CEOP reanalysis will be presented. W e will also review the data currently available and describe how to access the data.

Bosilovich, M.↗

Single Airfoil Gust Response Problem: Category 3, Problem 1

An unsteady aerodynamic code, called GUST3D (ref. 3), has been developed to solve equation (8) for flows with periodic vortical disturbances. The code uses a frequency-domain approach with second-order central differences and a pressure radiation condition in the far field. GUST3D requires as input certain mean flow quantities which are calculated separately by a potential flow solver. The solver calculates the mean ow using a Gothert's Rule approximation (ref. 3). On the airfoil surface, it uses the solution calculated by the potential code FLO36 (ref. 4). Figures 1-2 show the mean pressure along the airfoil surface for the two airfoil geometries. In Figures 3 - 8, we present the RMS pressure on the airfoil surface. Each figure shows three GUST3D solutions (calculated on grids with different far-field boundary locations). Three solutions are shown to provide some indication of the numerical uncertainty in the results. Figures 9 - 13 present the acoustic intensity. We again show three solutions per case. Note that no results are presented for the k1 = k2 = 2.0 loaded airfoil case, as an acceptable solution could not be obtained. A few comments need to be made about the results shown. First, since the last Workshop, the GUST3D code has been substantially upgraded. This includes implementing a more accurate far-field boundary condition (ref. 5) and developing improved gridding capabilities. This is the reason for any differences that may exist between the present results and results from the last Workshop. Second, the intensity results on the circle R = 4C were obtained using a Kirchoff method (ref. 6). The Kirchoff surface was the circle R = 2C. Finally, the GUST3D code is most accurate for low reduced frequencies. A new domain decomposition approach (ref. 7) has been developed to improve accuracy. Both the single domain and domain decomposition approaches were used in generating the present results.

Scott, James R.↗

Application of a Scalable, Parallel, Unstructured-Grid-Based Navier-Stokes Solver

A parallel version of an unstructured-grid based Navier-Stokes solver, USM3Dns, previously developed for efficient operation on a variety of parallel computers, has been enhanced to incorporate upgrades made to the serial version. The resultant parallel code has been extensively tested on a variety of problems of aerospace interest and on two sets of parallel computers to understand and document its characteristics. An innovative grid renumbering construct and use of non-blocking communication are shown to produce superlinear computing performance. Preliminary results from parallelization of a recently introduced "porous surface" boundary condition are also presented.

Parikh, Paresh↗

Queued Up: 2025 Edition – Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2024 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Queued Up: 2026 Edition, Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2025 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with https://www.interconnection.fyi. Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 50 non-ISO balancing areas), which collectively represent ~98% of currently installed U.S. electric generating capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Management Solution for Growing Loads at Airport Rental Facilities

Growing electrical loads across airport facilities could expand beyond local grid capacities. Coordinating flexible loads with generation and storage assets can reduce coincident peaks, mitigate costly upgrades, and reduce electricity costs. This report outlines how The Athena Team has developed a suite of tools, resources, and solutions to leverage load flexibility with energy assets to harness this value potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Global Surface Solar Energy Anomalies Including El Nino and La Nina Years

This paper synthesizes past events in an attempt to define the general magnitude, duration, and location of large surface solar anomalies over the globe. Surface solar energy values are mostly a function of solar zenith angle, cloud conditions, column atmospheric water vapor, aerosols, and surface albedo. For this study, solar and meteorological parameters for the 10-yr period July 1983 through June 1993 are used. These data were generated as part of the Release 3 Surface meteorology and Solar Energy (SSE) activity under the NASA Earth Science Enterprise (ESE) effort. Release 3 SSE uses upgraded input data and methods relative to previous releases. Cloud conditions are based on recent NASA Version-D International Satellite Cloud Climatology Project (ISCCP) global satellite radiation and cloud data. Meteorological inputs are from Version-I Goddard Earth Observing System (GEOS) reanalysis data that uses both weather station and satellite information. Aerosol transmission for different regions and seasons are for an 'average' year based on historic solar energy data from over 1000 ground sites courtesy of Natural Resources Canada (NRCan). These data are input to a new Langley Parameterized Shortwave Algorithm (LPSA) that calculates surface albedo and surface solar energy. That algorithm is an upgraded version of the 'Staylor' algorithm. Calculations are performed for a 280X280 km equal-area grid system over the globe based on 3-hourly input data. A bi-linear interpolation process is used to estimate data output values on a 1 X 1 degree grid system over the globe. Maximum anomalies are examined relative to El Nino and La Nina events in the tropical Pacific Ocean. Maximum year-to-year anomalies over the globe are provided for a 10-year period. The data may assist in the design of systems with increased reliability. It may also allow for better planning for emergency assistance during some atypical events.

Whitlock, C. H.↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Examples of State and Utility Actions on Proactive Planning and Investments

As states across the U.S. confront rising electricity demand, clean energy deployment, grid modernization imperatives, and the integration of large new loads, some regulators and utilities are shifting away from reactive, “just-in-time” investment approaches toward more proactive planning and investment frameworks. This report compiles examples of jurisdictional and utility actions that reshape planning processes, cost recovery mechanisms, and performance oversight to anticipate—rather than simply respond to—future grid needs. Several themes emerge from state actions examined in this report. First, legislatures and commissions are increasingly directing utilities to proactively upgrade their distribution and transmission systems, reflecting a shift toward a forward-looking system that aligns planning with state policy goals. Second, states are establishing long-term, iterative planning frameworks that often feature multi-year horizons, biannual or annual compliance reporting, structured opportunities for stakeholder engagement, and emphasis on collaboration among utilities, regulators, and stakeholders. Third, states are actively investigating innovative cost recovery mechanisms designed to support accelerated electrification and grid modernization, while balancing consumer advocates’ concerns regarding the ratepayer financial risks of premature investments. Fourth, performance metrics and reporting requirements are being developed to ensure transparency and accountability for proactive investments. Fifth, methodological improvements in planning—such as aligning load forecasting assumptions, incorporating sensitivities, and considering load management potential across building, vehicles, storage, and demand response—are recurring areas of stakeholder focus across jurisdictions. Overall, these developments signify a growing recognition among state regulators, utilities, and stakeholders that proactive planning—supported by clear definitions, consistent and transparent methodologies, robust performance metrics, and innovative cost recovery mechanisms—is a tool that can be used to address the scale and urgency of contemporary grid needs.

electricity market↗

Status of the Development of Flight Power Processing Units for the NASAs Evolutionary Xenon Thruster - Commercial (NEXT-C) Project

A pathfinder prototype unit and two flight power processing units (PPUs) are being developed by the Aerojet Rocketdyne Corporation in Redmond, Washington and ZIN Technologies in Cleveland, Ohio, in support of the NEXT-C Project. This project is being led by the NASA Glenn Research Center in Cleveland, Ohio, and will also yield two flight thrusters. This hardware is being considered to be provided as Government Furnished Equipment for the New Frontiers Program, and is applicable to a variety of planetary science missions and astrophysics science missions. The design of the NEXT-C PPU evolves from the hardware fabricated under the NEXT technology development project. The power processing unit operates from two sources: a wide input 80 to 160 V high-power bus and a nominal 28 V low-power bus. The unit includes six power supplies. Four power supplies (beam, accelerator, discharge, and neutralizer keeper) are needed for steady state operation, while two cathode heater power supplies (neutralizer and discharge) are utilized during thruster startup. The unit in total delivers up to 7 kW of regulated power to a single gridded-ion thruster. Significant modifications to the initial design include: high-power adaptive-delay control, upgrade of design to EEE-INST-002 compliance, telemetry accuracy improvements, incorporation of telemetry to detect plume-mode operation, and simplification of the design in select areas to improve manufacturability and commercialization potential. The project is presently in the prototype phase and preparing for qualification level environmental testing.

NASAaEuro(TM)s Evolutionary Xenon Thruster↗

An Open-Source Decarbonization Analytics Framework: Designing for Low-Carbon Emission Districts and Communities: Preprint

This paper introduces an open-source analytics framework designed to assist in creating low or net-zero carbon buildings and urban districts. Integrated within URBANopt, an open-source platform for energy analysis in districts and communities, this framework equips researchers, architects, engineers, and other stakeholders with tools to evaluate the carbon footprint implications of their design choices. The framework enables the analysis of various scenarios, incorporating both historical and future emission factors, and can span across different climate zones, each with distinct grid and emissions characteristics. The results showcase the framework's capability to evaluate the impact of design upgrades and control strategies on carbon emissions in districts and communities. An illustrative analysis using a hypothetical district in Denver, Colorado, shows reduced emissions from energy efficiency upgrades and control strategies, highlighting the sensitivity in their effects on emissions and energy use.

buildings energy efficiency↗

Combining CO2 Electrolysis with Biological Upgrading to Fuels and Chemicals: Turning Waste into Fuels

The utilization of flue gas-derived CO2 presents an opportunity to enhance carbon utilization in the bioethanol industry, contributing to the production of valuable products. In the context of a 90 million-gallon-per-year corn ethanol plant generating approximately 30 tons per hour of 99% pure CO2, a collaborative effort involving six national laboratories has been established. This initiative, known as the CO2 Reduction and Upgrading for e-Fuels (CO2RUe) Consortium, is funded by the Department of Energy's BioEnergy Technologies Office (BETO). The primary objective of the CO2RUe Consortium is to explore innovative approaches to harness CO2 as a valuable feedstock. This interdisciplinary consortium integrates electrochemistry with biological upgrading techniques, aiming to yield sustainable, value-added products and aviation fuels. The presentation will delve into the recent advancements in the realms of electrochemistry and biological upgrading, with a specific focus on formic acid and CO. Additionally, the talk will include an analysis of future electricity grid scenarios, technoeconomic evaluations, and life-cycle assessments. These assessments aim to provide a comprehensive understanding of the impacts of various conversion pathways on both cost and carbon intensity. The CO2RUe Consortium is at the forefront of steering the development of economically favorable and sustainable processes for CO2 utilization. The presentation will showcase the consortium's progress in driving the advancement of technology and processes, emphasizing the economic viability and sustainability of CO2 utilization within the broader context of the bioethanol industry.

biological upgrading↗

Comprehensive Life Cycle Analysis of Methanol Production and Methanol-to-Diesel Conversion

Methanol is a strategic chemical and intermediate in the manufacture of synthetic diesel, due to its versatility, diesel’s compatibility with existing infrastructure, and their role in industrial and transport applications. Conventional production methods for methanol, primarily steam methane reforming (SMR), rely on natural gas and are subject to the price variability due to market conditions and geopolitical events. They are also associated with greenhouse gas (GHG) emissions. Methanol and synthetic diesel production could be integrated with nuclear energy to stabilize fuel prices and insulate pricing from outside geopolitical events due to the relative stability of nuclear fuel as compared to natural gas. This could lead to increased transportation fuel security, reliability and resilience. An added benefit is the abatement of emissions when substituting nuclear energy for conventional energy from natural gas. This report presents a comprehensive life cycle analysis(LCA) framework which was developed to evaluate the GHG emissions reduction potential associated with nuclear integrated methanol production, methanol-to-diesel upgrading, and end-use combustion. Gate-to-gate methanol production and cradle-to-grave emissions were evaluated in, starting with a business-as-usual (BAU) SMR-based methanol plant, and then considering stepwise nuclear integration. Methanol-to-diesel (MTD) conversion was evaluated accounting for nuclear energy integration and hydrogen production via high-temperature steam electrolysis (HTSE) using electricity either from the grid or from a dedicated nuclear power system. This multi-step process diverts stable and reliable nuclear energy into the transportation sector by upgrading low energy dense natural gas into liquid fuels fully compatible with existing infrastructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Upgrades to the TRIUMF Fast Ion Counter, TRIFIC

TRIFIC, the TRIUMF Fast Ion Counter, is a downstream ionization chamber which provides beam composition monitoring and recoil tagging for in-beam reaction experiments. TRIFIC has been commissioned and deployed for use with radioactive isotope beams at the TRIUMF-ISAC facility. Recently, the detector has been upgraded to include an improved gas window that can accommodate higher beam rates and position-sensitive electrode grids for better position reconstruction.

Gaseous detectors↗

CAGI: Computer Aided Grid Interface. A work in progress

Progress realized in the development of a Computer Aided Grid Interface (CAGI) software system in integrating CAD/CAM geometric system output and/or Interactive Graphics Exchange Standard (IGES) files, geometry manipulations associated with grid generation, and robust grid generation methodologies is presented. CAGI is being developed in a modular fashion and will offer fast, efficient and economical response to geometry/grid preparation, allowing the ability to upgrade basic geometry in a step-by-step fashion interactively and under permanent visual control along with minimizing the differences between the actual hardware surface descriptions and corresponding numerical analog. The computer code GENIE is used as a basis. The Non-Uniform Rational B-Splines (NURBS) representation of sculptured surfaces is utilized for surface grid redistribution. The computer aided analysis system, PATRAN, is adapted as a CAD/CAM system. The progress realized in NURBS surface grid generation, the development of IGES transformer, and geometry adaption using PATRAN will be presented along with their applicability to grid generation associated with rocket propulsion applications.