Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid quality power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Smart-PGSim: Using Neural Network to Accelerate AC-OPF Power Grid Simulation

In this work we address the problem of accelerating complex power-grid simulation through machine learning ( ML). Specifically, we develop a framework, Smart-PGSim,which generates multitask-learning (MTL) neural network (NN)models to predict the initial values of variables critical to the problem convergence. MTL models allow information sharing when predicting multiple dependent variables while including customized layers to predict individual variables. We show that,to achieve the required accuracy, it is paramount to embed domain-specific constraints derived from the specific power-grid components in the MTL model. Smart-PGSim then employs the predicted initial values as a high-quality initial condition for the power-grid numerical solver (warm start), resulting in both higher performance compared to state-of-the-art solutions while maintaining the required accuracy. Smart-PGSim brings 2.60×speedup on average (up to 3.28×) computed over 10,000 problems, without losing solution optimality.

machine learning, neural networks↗

Open Power System Datasets and Open Simulation Engines: A Survey Toward Machine Learning Applications

A major factor behind the success of machine learning (ML) models in multiple domains is the availability and accessibility of large, labeled, and well-organized datasets for training and benchmarking. In comparison, power grid datasets face three major challenges: (i) real-world data is often restricted by regulatory constraints, privacy reasons, or security concerns, making it difficult to obtain and work with; (ii) synthetic datasets, which are created to address these limitations, often have incomplete information and are released using specialized tools, making them inaccessible to the broader community; and, (iii) input-output datasets are difficult to generate through simulation for non-experts because open-source simulators are not known outside the power system community. This survey addresses these challenges by serving as an entry point to publicly available datasets and simulators for researchers venturing in this area. We review the current landscape of open-source power network data, machine models, consumer demand profiles, renewable generation data, and inverter models. We also examine open-source power system simulators, which are crucial for generating high-quality, high-fidelity power grid datasets. We aim to provide a foundation for overcoming data scarcity and advance towards a structured web of datasets and simulators to support the development of ML for power systems.

42 ENGINEERING↗

Real-Time Optimization of Distribution-level Energy Resources [SWR-18-27]

Researchers at NREL have developed a novel real-time control architecture to optimize the operation of DERs at residential, commercial, and industrial levels. The real-time system enables (portions of) feeders to emulate virtual power plants providing services to the rest of the grid, while ensuring satisfaction of electrical limits and maximizing customers’ benefits. This system can be integrated with legacy hardware and/or new advanced systems to optimally manage both individually-controlled DERs and aggregations of DERs. By virtue of the proposed engineering approach, the DERs collectively regulate the powers at an electrical point to respond to grid dispatch signals such as an automatic generation control, a ramping signal, or a 5-minute dispatch. Overall, this architecture allows end customers to minimize their payments and partake in grid operations while guaranteeing power quality in the distribution network.

Dall-Anese, Emiliano↗

Guidelines for Implementing Advanced Distribution Management Systems: Requirements for DMS Integration with DERMS and Microgrids

This guideline focuses on the integration of DMS with DERMS and microgrids connected to the distribution grid by defining generic and fundamental design and implementation principles and strategies. It starts by addressing the current status, objectives, and core functionalities of each system, and then discusses the new challenges and the common principles of DMS design and implementation for integration with DERMS and microgrids to realize enhanced grid operation reliability and quality power delivery to consumers while also achieving the maximum energy economics from the DER and microgrid connections.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photovoltaic Microinverter Testbed for Multiple Device Interoperability

IEEE Standard 1547-2003 conformance of several interconnected microinverters was performed by Sandia National Laboratories (SNL) to determine if there were emergent adverse behaviors of co-located aggregated distributed energy resources. Experiments demonstrated the certification tests could be expanded for multi-manufacturer microinverter interoperability. Evaluations determined the microinverters' response to abnormal conditions in voltage and frequency, interruption in grid service, and cumulative power quality. No issues were identified to be caused by the interconnection of multiple devices.

42 ENGINEERING↗

ADMS Test Bed: Defining a Use Case for Data Improvement for ADMS Deployment: Preprint

Advanced distribution management systems (ADMS) provide a suite of tools for meeting the needs of a modern grid - higher reliability and power quality, improved resiliency and security, lower costs and enhanced customer participation. Data quality has two-fold impact on ADMS adoption: 1. Data quality improvement may constitute up to 25% of ADMS deployment costs. 2. The accuracy of data and models used by the ADMS greatly affect the utility's ability to meet the operational objectives. Thus, quantifying the data quality requirements and its impact on performance is critical to reducing the overall cost of deployment, enabling wider adoption and ensuring that the ADMS performs as specified. The paper offers the motivation, methodology and evaluation strategy for filling this critical gap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Value and Technology Assessment to Enhance the Business Case for the CERTS Microgrid

The CERTS Microgrid concept is an advanced approach for enabling integration of, in principle, an unlimited quantity of distributed energy resources into the electricity grid. A key feature of a microgrid, is its ability, during a utility grid disturbance, to separate and isolate itself from the utility seamlessly with no disruption to the loads within the microgrid (including no reduction in power quality). Then, when the utility grid returns to normal, the microgrid automatically resynchronizes and reconnects itself to the grid, in an equally seamless fashion. What is unique about the CERTS Microgrid is that it can provide this technically challenging functionality without extensive (i.e., expensive) custom engineering. In addition, the design of the CERTS Microgrid also provides high system reliability and great flexibility in the placement of distributed generation within the microgrid. The CERTS Microgrid offers these functionalities at much lower costs than traditional approaches by incorporating peer-to-peer and plug-and-play concepts for each component within the Microgrid. The predecessor to the current project involved the construction of and completion of initial testing using the world's first, full-scale, inverter-based, distributed generation test bed. The project demonstrated three advanced techniques, collectively referred to as the CERTS Microgrid concept, which collectively significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques are: (1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; (2) an approach to electrical protection within the microgrid that does not depend on high fault currents; and (3) a method for microgrid control that achieves voltage and frequency stability under both grid and islanded conditions without requiring high-speed communications. The work conducted in this phase of RD&D on the CERTS Microgrid Concept builds upon this base of technical accomplishments to prioritize, develop, and then demonstrate technology enhancements to further enhance the business case for microgrids. That is, having demonstrated the technical feasibility of microgrid functions, RD&D optimization efforts are now needed to accelerate commercial deployment. The current phase is a contribution to these efforts. This project involved seven distinct analysis, bench-, and full-scale testing tasks. The first five tasks were described in the original proposal submitted and awarded through DOE's solicitation. Two additional tasks were added to address issues that had been identified in the earlier, first phase of testing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An islanding detection methodology combining decision trees and Sandia frequency shift for inverter-based distributed generations

Distributed generations (DGs) for grid-connected applications require an accurate and reliable islanding detection methodology (IDM) for secure system operation. This paper presents an IDM for grid-connected inverter-based DGs. The proposed method is a combination of passive and active islanding detection techniques for aggregation of their advantages and elimination/minimisation of the drawbacks. In the proposed IDM, the passive method utilises critical system attributes extracted from local voltage measurements at target DG locations as well as employs decision tree-based classifiers for characterisation and detection of islanding events. The active method is based on Sandia frequency shift technique and is initiated only when the passive method is unable to differentiate islanding events from other system events. Thus, the power quality degradation introduced into the system by active islanding detection techniques can be minimised. Furthermore, a combination of active and passive techniques allows detection of islanding events under low power mismatch scenarios eliminating the disadvantage associated with the use of passive techniques alone. Finally, detailed case study results demonstrate the effectiveness of the proposed method in detection of islanding events under various power mismatch scenarios, load quality factors and in the presence of single or multiple grid-connected inverter-based DG units.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Export of reactive nitrogen from coal-fired power plants in the U.S.: Estimates from a plume-in-grid modeling study - article no. D04308

The export of reactive nitrogen (nitrogen oxides and their oxidation products, collectively referred to as NOy) from coal-fired power plants in the U.S. to the rest of the world could have a significant global contribution to ozone. Traditional Eulerian gridded air quality models cannot characterize accurately the chemistry and transport of plumes from elevated point sources such as power plant stacks. A state-of-the-science plume-in-grid (PinG) air quality model, a reactive plume model embedded in an Eulerian gridded model, is used to estimate the export of NOy from 25 large coal-fired power plants in the U. S. (in terms of NOx and SO{sub 2} emissions) in July 2001 to the global atmosphere. The PinG model used is the Community Multiscale Air Quality Model with Advanced Plume Treatment (CMAQ-APT). A benchmark simulation with only the gridded model, CMAQ, is also conducted for comparison purposes. The simulations with and without advanced plume treatment show differences in the calculated export of NOy from the 25 plants considered reflecting the effect of using a detailed and explicit treatment of plume transport and chemistry. The advanced plume treatment results in 31% greater simulated export of NOy compared to the purely grid-based modeling approach. The export efficiency of NOy (the fraction of NOy emitted that is exported) is predicted to be 21% without APT and 27% with APT. When considering only export through the eastern boundary across the Atlantic, CMAQ-APT predicts that the export efficiency is 24% and that 2% of NOy is exported as NOx, 49% as inorganic nitrate, and 25% as PAN. These results are in reasonably good agreement with an analysis reported in the literature of aircraft measurements over the North Atlantic.

01 COAL, LIGNITE, AND PEAT↗

Unstructured viscous grid generation by advancing-front method

A new method of generating unstructured triangular/tetrahedral grids with high-aspect-ratio cells is proposed. The method is based on new grid-marching strategy referred to as 'advancing-layers' for construction of highly stretched cells in the boundary layer and the conventional advancing-front technique for generation of regular, equilateral cells in the inviscid-flow region. Unlike the existing semi-structured viscous grid generation techniques, the new procedure relies on a totally unstructured advancing-front grid strategy resulting in a substantially enhanced grid flexibility and efficiency. The method is conceptually simple but powerful, capable of producing high quality viscous grids for complex configurations with ease. A number of two-dimensional, triangular grids are presented to demonstrate the methodology. The basic elements of the method, however, have been primarily designed with three-dimensional problems in mind, making it extendible for tetrahedral, viscous grid generation.

Pirzadeh, Shahyar↗

Unstructured viscous grid generation by advancing-layers method

A new method of generating unstructured triangular/tetrahedral grids with high-aspect-ratio cells is proposed. The method is based on new grid-marching strategy referred to as 'advancing-layers' for construction of highly stretched cells in the boundary layer and the conventional advancing-front technique for generation of regular, equilateral cells in the inviscid-flow region. Unlike the existing semi-structured viscous grid generation techniques, the new procedure relies on a totally unstructured advancing-front grid strategy resulting in a substantially enhanced grid flexibility and efficiency. The method is conceptually simple but powerful, capable of producing high quality viscous grids for complex configurations with ease. A number of two-dimensional, triangular grids are presented to demonstrate the methodology. The basic elements of the method, however, have been primarily designed with three-dimensional problems in mind, making it extendible for tetrahedral, viscous grid generation.

Pirzadeh, Shahyar↗

Development of a smart DC grid model

Smart grid and distributed generation should be the solution of the global climate change and the crisis energy of the main source of electrical power generation which is fossil fuel. In order to meet the rising electrical power demand and increasing service quality demands, as well as reduce pollution, the existing power grid infrastructure should be developed into a smart grid and distributed power generation which provide a great opportunity to address issues related to energy efficiency, energy security, power quality and aging infrastructure systems. The conventional of the existing distributed generation system is an AC grid while for a renewable resources requires a DC grid system. This paper explores the model of smart DC grid by introducing a model of smart DC grid with the stable power generation give a minimal and compressed circuitry that can be implemented very cost-effectively with simple components. The PC based application software for controlling was developed to show the condition of the grid and to control the grid become ‘smart’. The model is then subjected to a severe system perturbation, such as incremental change in loads to test the performance of the system again stability. It is concluded that the system able to detect and controlled the voltage stability which indicating the ability of power system to maintain steady voltage within permissible rangers in normal condition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power system effects and mitigation recommendations for DER cyberattacks

Extensive deployment of interoperable distributed energy resources (DER) is increasing the power system cyber security attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid‐support functions, which can drastically influence power quality, voltage, and bulk system frequency. Here, the authors investigate the impact to the cyber‐physical power system in scenarios where communications and operations of DER are controlled by an adversary. The findings show that each grid‐support function exposes the power system to distinct types and magnitudes of risk. The physical impact from cyber actions was analysed in cases of DER providing distribution system voltage regulation and transmission system support. Finally, recommendations are presented for minimising the risk using engineered parameter limits and segmenting the control network to minimise common‐mode vulnerabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating PEVs with Renewables and the Grid

This presentation is an overview of NREL's Electric Vehicle Grid Integration (EVGI) efforts toward integrating Plug-in Electric Vehicles (PEVs) with renewable energy and the grid. Efforts include managed charging, local power quality, emergency backup power, and bi-directional power flow. Discussion of future vehicle-related activities under the Grid Modernization Initiative by the Multi-Lab EV Smart Grid Working Group.

33 ADVANCED PROPULSION SYSTEMS↗

Development of economically viable, highly integrated, highly modular SEGIS architecture

Initiated in 2008, the SEGIS initiative is a partnership involving the U.S. DOE, Sandia National Laboratories, private sector companies, electric utilities, and universities. Projects supported under the initiative have focused on the complete-system development of solar technologies, with the dual goal of expanding renewable PV applications and addressing new challenges of connecting large-scale solar installations in higher penetrations to the electric grid. Petra Solar, Inc., a New Jersey-based company, received SEGIS funds to develop solutions to two of these key challenges: integrating increasing quantities of solar resources into the grid without compromising (and likely improving) power quality and reliability, and moving the design from a concept of intelligent system controls to successful commercialization. The resulting state-of-the art technology now includes a distributed photovoltaic (PV) architecture comprising AC modules that not only feed directly into the electrical grid at distribution levels but are equipped with new functions that improve voltage stability and thus enhance overall grid stability. This integrated PV system technology, known as SunWave, has applications for 'Power on a Pole,' and comes with a suite of technical capabilities, including advanced inverter and system controls, micro-inverters (capable of operating at both the 120V and 240V levels), communication system, network management system, and semiconductor integration. Collectively, these components are poised to reduce total system cost, increase the system's overall value and help mitigate the challenges of solar intermittency. Designed to be strategically located near point of load, the new SunWave technology is suitable for integration directly into the electrical grid but is also suitable for emerging microgrid applications. SunWave was showcased as part of a SEGIS Demonstration Conference at Pepco Holdings, Inc., on September 29, 2011, and is presently undergoing further field testing as a prelude to improved and expanded commercialization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Systematic adaptation of data delivery

This disclosure describes, in part, a system management component for use in a power grid data network to systematically adjust the quality of service of data published by publishers and subscribed to by subscribers within the network. In one implementation, subscribers may identify a desired data rate, a minimum acceptable data rate, desired latency, minimum acceptable latency and a priority for each subscription and the system management component may adjust the data rates in real-time to ensure that the power grid data network does not become overloaded and/or fail. In one example, subscriptions with lower priorities may have their quality of service adjusted before subscriptions with higher priorities. In each instance, the quality of service may be maintained, even if reduced, to meet or exceed the minimum acceptable quality of service for the subscription.

24 POWER TRANSMISSION AND DISTRIBUTION↗