Engineering PapersSearch

SEARCH · Engineering Papers

Results for “grid modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Grid Reliability Statistics [SWR-25-45]

This codebase houses a suite of statistical and descriptive analyses of NERC GADS data of interest to grid modelers and planners. This repository is envisioned to house a collection of statistical and descriptive summaries of NERC GADS data, particularly summaries that on their own might be insufficient to warrant publication. In addition, it is intended to disseminate results rather than to enable reproduction as GADS is non-public.

Murphy, Sinnott [National Renewable Energy Laborat

Grid-Kitchen/grid-meta (33407-E)

A repository for extracting dehydrated metadata for distribution power grid model.

Duwadi, Kapil [Pacific Northwest National Laborato

Graph-Learning-Assisted State and Event Tracking for Solar-Penetrated Power Grids with Heterogeneous Data Sources

Unlike transmission systems, distribution systems do not typically contain sufficient metering to enable real-time state estimation. The lack of sufficient real-time measurements prohibits accurate and timely monitoring of the state of distribution systems. As a result, control and optimal operation of distribution systems, especially those containing large numbers of renewable generation units are not possible without proper data and information about the current state of the system. The main motivation of this project is to address this shortcoming by developing an approach which provides “predicted” real-time measurements so that they can be used to execute a distribution system state estimator. Thus, the objective of the project is to make the distribution systems fully observable, such that the hosting capacity for solar generation can be accurately estimated, and unnecessary solar curtailments can be avoided. In order to accomplish this goal, the project investigated the use of a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams obtained from AMI meters, SCADA as well as PMU measurements and created synchronous measurement snapshots for the state estimator (SE); and developed a hybrid robust SE which provides not only accurate state estimates but also real-time feedback for the ML model refinement.

14 SOLAR ENERGY

Data Center Market Report

The data center market is poised to explode in the coming decade due to undeniable drivers such as continued adoption of generative AI, increased data storage needs, and enterprise integration of AI in numerous industries [1] [2] [3]. Scalable power and increased computational capacity are at the forefront of considerations for hyperscalers, the major cloud service providers in this space. Lawrence Livermore National Laboratory is uniquely poised to help with informed decision making for data center market leaders during this phase of explosive expansion. National grid modeling expertise and cutting edge innovations in computer cooling systems place LLNL in an enviable position for creating economic impact in the data center industry by leveraging its expertise in these areas which can help the data center market keep up with growing demand.

97 MATHEMATICS AND COMPUTING

Advanced Computing Annual Report 2025 [Slides]

In Fiscal Year (FY) 2025, the National Laboratory of the Rockies (NLR) continued to advance computing as a cornerstone of energy innovation, expanding the Kestrel high-performance computing (HPC) system to 56 peak petaflops. This growth strengthened Kestrel's role as a national asset for applied energy research, enabling larger, more complex simulations and accelerating the integration of artificial intelligence (AI) methods across the laboratory's computing portfolio. In FY 2025, AI was a component of most projects running on Kestrel, underscoring its central role in modern energy science and engineering. Kestrel supported a broad and diverse set of 507 modeling and simulation projects, engaging 855 researchers across the U.S. Department of Energy's (DOE's) Office of Critical Minerals and Energy Innovation (CMEI) portfolio and other offices, as well as partners from industry, academia, and utilities. These efforts span critical materials discovery, energy systems modeling, grid modernization, advanced manufacturing, and other areas essential to strengthening U.S. energy security and competitiveness. Together, these collaborations produced 708 technical outputs, including 293 peer-reviewed publications, reflecting both the depth and impact of the science enabled by NLR's computing capabilities. This year's report highlights the growing importance and benefit of AI throughout NLR's research programs and features work by early career researchers who are helping shape the future of computing-enabled energy innovation. Explore these sections and the many project successes captured in the pages that follow.

97 MATHEMATICS AND COMPUTING

5-minute Wind Power Data based on WFIP2 WRF Simulation

The second Wind Forecast Improvement Project (WFIP2) was a public-private partnership funded by the U.S. Department of Energy and NOAA, aimed at enhancing the forecast skill of numerical weather prediction models for turbine-height winds in regions with complex terrain. An 18-month Weather Research and Forecasting (WRF) model simulation was conducted over the Pacific Northwest, with model outputs validated against observational data collected during WFIP2. Simulated wind speeds were used to estimate wind power generation using reV (the Renewable Energy Potential Model developed by NREL) at ten wind project sites. Two sets of results were produced: one using wind speeds extracted from the model grid cell at the project centroid, and another using wind speeds from the actual turbine locations. For each dataset, power output was calculated using both actual turbine-specific power curves and nine generic power curves to convert wind speed into power.

17 WIND ENERGY

The BTSbot-nearby Discovery of SN 2024jlf: Rapid, Autonomous Follow-up Probes Interaction in an 18.5 Mpc Type IIP Supernova

We present observations of the Type IIP supernova (SN) SN 2024jlf, including spectroscopy beginning just 0.7 days (∼17 hr) after first light. Rapid follow-up was enabled by the new BTSbot-nearby program, which involves autonomously triggering target-of-opportunity requests for new transients in Zwicky Transient Facility data that are coincident with nearby (D < 60 Mpc) galaxies and identified by the BTSbot machine learning model. Early photometry and nondetections shortly prior to first light show that SN 2024jlf initially brightened by >4 mag day −1 , quicker than ∼90% of Type II SNe. Early spectra reveal weak flash ionization features: narrow, short-lived (1.3 < τ[days] < 1.8) emission lines of Hα, He II , and C IV . Assuming a wind velocity of v w = 50 km s −1 , these properties indicate that the red supergiant progenitor exhibited enhanced mass loss in the last year before explosion. We constrain the mass-loss rate to $1{0}^{-4}\lt \dot{M}\,[{M}_{\odot }\,{\mathrm{yr}}^{-1}]\lt 1{0}^{-3}$ by matching observations to model grids from two independent radiative hydrodynamics codes. BTSbot-nearby automation minimizes spectroscopic follow-up latency, enabling the observation of ephemeral early-time phenomena exhibited by transients.

core-collapse supernovae

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]

EVs@Scale Next-Gen Profiles - EV Profile Capture 2024

As part of the U.S. DOE EVs@Scale consortium Next-Gen Profiles (NGP) project, the profile capture and analysis of production electric vehicles undergoing high power charging (HPC) is conducted over a wide range of conditions to explore variance and performance. Charge session parameters are collected from both the electric vehicle (EV) and electric vehicle supply equipment (EVSE) at a rate of 10Hz and entered into a time-series database for analysis. These charge profiles are captured under nominal and off-nominal conditions, exploring the impact of battery state of charge (SOC), battery temperature, vehicle condition, smart charge management (SCM), and EVSE limitations. Nominal conditions are defined to be ideal conditions that should transfer the maximum allowable energy in the minimum possible amount of time. Nominal condition profiles are compared across EVs to characterize state-of-the-art EV charging performance against one another. Off-nominal condition profiles are compared against its nominal condition profile counterpart to highlight the variance across less desirable starting conditions within a single EV. This EV Profile Capture 2024 report stands as an update from the EV Profile Capture 2023 report to include the additional EV & EVSE assets tested and analyzed in 2024. The major updates within this report include the addition of three next-generation electric vehicles, added test cases, and further analysis. This expansion of analysis includes power profiles, power distribution, quantifying SOC, energy and range performance, EVSE limitation impacts, boost converter performance, etc. Additionally, NGP time-series data has been used as input towards three national laboratory-led grid modelling efforts: ANL’s IEEE-37 HIL model, INL’s Caldera model, and NREL’s EVI-X model. A summary of these platforms and how NGP has worked to improve their effectiveness has also been added to this years’ report.

Thurston, Sam

Strengthening U.S. National Security Through Advanced Energy Innovation

NREL's work in strategic energy security is focused on keeping the United States secure and its citizens safe by applying expertise in advanced energy systems and technologies to prevent energy system disruptions from any source, natural or human. NREL pursues national security objectives by providing partners an accurate understanding of national and international security implications of global energy trends; novel installation, facility, and operational energy solutions; access to NREL R&D capabilities to incorporate advanced energy technologies and biomaterials into mission requirements; and the ability to test future technologies using large-scale grid modeling.

24 POWER TRANSMISSION AND DISTRIBUTION

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models

An Optimized Parameterization of Sub‐Grid Scale Advection for Convection Permitting Models

Convection‐permitting models (CPMs) explicitly resolve deep convection yet under‐resolve the organized lateral exchanges among drafts and their environment that control entrainment/detrainment, precipitation efficiency, and mesoscale structure. In this work, we introduce the Optimized Advection Scheme (OAS), which introduces a small rotation of the Cartesian frame of reference for the horizontal winds relative to other variables used in advection that induces cross‐gradient transport to mimic under‐resolved convective mixing. The rotation angle is selected to minimize the Kullback–Leibler divergence between the simulated and satellite observed precipitation intensity distributions, yielding a physically consistent perturbation that is computationally inexpensive and portable. Optimized Advection Scheme is implemented in WRF and evaluated over Amazon (April 2014). It shifts precipitation–precipitable‐water joint distributions toward lighter rain, reduces overly intense rates, and improves mesoscale convective system (MCS) lifetime and propagation. Mechanistically, the added cross‐gradient transport promotes convective detrainment and environmental mixing, which cools and moistens the mid‐troposphere, weakens downward momentum transport, alleviates excessive downwelling shortwave biases, and warms the surface temperature. The optimized rotation angle yields comparable improvements at 4‐km and 1‐km grid spacing, demonstrating resolution‐independent benefits across the CPM gray zone. By targeting the dynamical root of under‐mixed convective circulations, rather than tuning model microphysics or closures, OAS delivers robust, scale‐aware improvements in precipitation statistics, cloud vertical structure, and characteristics of MCS (MCSs), offering a practical pathway to more reliable CPM simulations for weather and climate applications.

CPM

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters

An Overview of Electric Vehicle Load Modeling Strategies for Grid Integration Studies

The adoption of electric vehicles (EVs) has emerged as a solution to reduce greenhouse gas emissions in the transportation sector, which has motivated the implementation of public policies to promote their use in several countries. However, the high adoption of EVs poses challenges for the electricity sector, as it would imply an increase in energy demand and possible impacts on the power quality (PQ) of the power grid. Therefore, it is important to conduct EV integration studies in the power grid to determine the amount that can be incorporated without causing problems and identify the areas of the power sector that will require reinforcements. Accurate EV load patterns are required for this type of study that, through mathematical modeling, reflect both the dynamic behavior and the factors that influence the decision to recharge EVs. This article aims to present an overview of EVs, examine the different factors considered in the literature for modeling EV load patterns, and review modeling methods. EV load modeling methods are classified into deterministic, statistical, and machine learning. The article shows that each modeling method has its advantages, disadvantages, and data requirements, ranging from simple load modeling to more accurate models requiring large datasets.

Computer Science

Achieving geometric accuracy in FFT-based micromechanical models using conformal grid

Owing to its efficiency, simplicity and robustness, the FFT-based method has become the standard for computation of mechanical fields in a heterogeneous periodic unit cell. One of the main disadvantages of the FFT-based method is the inaccurate representation of the initial microstructure on a regular grid of voxels, which can be alleviated through the use of distorted initial grids. Here, in this paper, a method for generation of distorted initial grids conforming to the microstructural features (e.g. straight/curved boundaries) is proposed. The method determines the positions of the grid nodes in the initial configuration by solving a system of springs connecting the nodes. Microstructures consisting of layers, Voronoi tessellation and circular/spherical inclusions are considered, and mechanical fields simulated using the FFT-based method. It is found that distorted initial grids, conforming to the microstructural features, lead to more accurate mechanical fields in comparison to the corresponding non-distorted initial grid solution. The effect of initial grid distortion on the convergence of the FFT-based method is analyzed and discussed.

36 MATERIALS SCIENCE

A Model Predictive Control to Improve Grid Resilience

The following article details a model predictive control (MPC) to improve grid resilience when faced with variable generation resources. This topic is of significant interest to utility power systems where distributed intermittent energy sources will increase significantly and be relied on for electric grid ancillary services. Previous work on MPCs has focused on narrowly targeted control applications such as improving electric vehicle (EV) charging infrastructure or reducing the cost of integrating Energy Storage Systems (ESSs) into the grid. In contrast, this article develops a comprehensive treatment of the construction of an MPC tailored to electric grids and then applies it integration of intermittent energy resources. To accomplish this, the following article includes a description of a reduced order model (ROM) of an electric power grid based on a circuit model, an optimization formulation that describes the MPC, a collocation method for solving linear time-dependent differential algebraic equations (DAEs) that result from the ROM, and an overall strategy for iteratively refining the behavior of the MPC. Next, the algorithm is validated using two separate numerical experiments. First, the algorithm is compared to an existing MPC code and the results are verified by a numerically precise simulation. It is shown that this algorithm produces a control comparable to existing algorithms and the behavior of the control carefully respects the bounds specified. Second, the MPC is applied to a small nine bus system that contains a mix of turbine-spinning-machine-based and intermittent generation in order to demonstrate the algorithm’s utility for resource planning and control of intermittent resources. This study demonstrates how the MPC can be tuned to change the behavior of the control, which can then assist with the integration of intermittent resources into the grid. The emphasis throughout the paper is to provide systematic treatment of the topic and produce a novel nonlinear control compatible design framework applicable to electric grids and the control of variable resources. This differs from the more targeted application-based focus in most presentations.

microgrid