Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “graphite crystal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Measurement of the X-ray emission of the solar atmosphere during a period of low activity

A large-area high-sensitivity X-ray spectrometer has been constructed and used to measure the 1.8- to 5.3-A X-ray emission of the sun under quiescent conditions. The instrument utilizes Bragg reflection from mosaic graphite crystals. The data indicate that the X-ray emission can best be accounted for by a multitemperature model of the solar atmosphere in which both the overall corona and active regions contribute to the X-ray spectrum. Theoretical calculations of the X-ray flux of a hot, optically thin plasma have been used to estimate the solar conditions at the time when the measurements were made.

Wolff, R. S.↗

The X-ray line and continuum emission from a solar active region

The X-ray spectrum of the quiet sun in the energy range 2.3 - 6.9 keV was observed from an Aerobee rocket using an uncollimated graphite crystal spectrometer. These results and spatial measurements made with an onboard modulation collimator are analyzed using solar models.

Landecker, P. B.↗

The X-ray line and continuum emission from a solar active region

The X-ray spectrum of the quiet sun in the energy range of 2.3-6.9 keV was observed from an Aerobee rocket using an uncollimated graphite crystal spectrometer. These results and spatial measurements made with an onboard modulation collimator are analyzed using solar models. Several methods of estimating coronal temperatures are used in the analysis and all yield results within the range of (4 plus or minus 1) million K.

Landecker, P. B.↗

Search for X-ray line emission from A0620-00

Measurements of the X-ray spectrum (1.85-7 keV) of A0620-00 obtained on 1975 October 17 and 1976 January 1-9 with the graphite crystal spectrometer on OSO-8 show a smooth continuum with an absence of emission lines. Upper limits are given for line emission from Si and S ions and are used to establish that the source is not optically thin. The results support a dense plasma model.

Kestenbaum, H. L.↗

Measurement of the X-ray polarization of the Crab Nebula

The graphite crystal X-ray polarimeters aboard the OSO-8 satellite were used to observe the Crab Nebula for six days from March 11 through March 17, 1976 (UT). Analysis of 15 orbits of quick-look data shows that the polarization and position angles at 2.6 and 5.2 keV are 15.7%(+ or - 1.5%) at 161.1(+ or - 2.8) deg and 18.3%(+ or - 4.2%) at 155.5(+ or - 6.6) deg, respectively. These results confirm the previous measurement and the hypothesis of synchrotron X-ray emission.

Weisskopf, M. C.↗

Search for thermal X-ray line emission from the Crab Nebula

Observations of the Crab Nebula from 1.85 to 8 keV obtained with the large-area graphite crystal spectrometer on OSO-8 show a smooth featureless continuum with an absence of X-ray emission lines from highly ionized Si and S. Upper limits on the line emission are used to derive an upper limit to the emission measure for a thermal source associated with the Crab Nebula. Existing evidence for an extended thermal source is discussed, and it is shown that the evidence is not contradicted by the upper limits set with the spectrometer data.

Kestenbaum, H. L.↗

A precision measurement of the X-ray polarization of the Crab Nebula without pulsar contamination

The linear X-ray polarization of the Crab Nebula has been precisely measured at 2.6 keV and 5.2 keV with the OSO 8 graphite crystal polarimeters. The 1.4 ms time resolution of these instruments permitted the removal of any contribution to the polarization from the pulsar. The nebular polarization is 19.2% plus or minus 1.0% at a position angle of 156.4 plus or minus 1.4 deg at 2.6 keV. At 5.2 keV the corresponding results are 19.5% plus or minus 2.8% at 152.6 plus or minus 4.0 deg.

Weisskopf, M. C.↗

An upper limit to the linear X-ray polarization of Scorpius X-1

A measurement of Sco X-1 with the graphite-crystal polarimeters on the OSO 8 satellite yields upper limits (3 sigmas) to the linear polarization of 2.7% and 4.9% at 2.6 keV and 5.2 keV, respectively. The results are discussed in terms of an accretion-disk model.

Weisskopf, M. C.↗

Search for X-ray line emission from Cassiopeia A

The large area graphite crystal spectrometer aboard OSO 8 has been used to search for X-ray line emission from Cas A from ions of Si, S, and Fe over the energy band 1.865 to 8 keV. No evidence was obtained for line emission. The upper limits for the Si and S line fluxes are used to establish upper limits on the abundances of these elements. The limit on the Fe line flux is consistent with the strength of the emission feature reported in proportional counter experiments. Questions of nonequilibrium in ionization in Cas A and the effects on X-ray line emission are considered.

Kestenbaum, H. L.↗

Solar X-ray flares observed with the Columbia University instrument on OSO-8

Observations of solar X-ray flares with a graphite-crystal spectrometer aboard the OSO 8 satellite are discussed. The development of the temperature and emission measure of a typical subflare is examined, and the temperature dependence of three Si satellite line systems is derived. Possible electron densities in the range between 10 to the 13th power and 10 to the 14th power per cu cm are determined from the intensities of He-like lines. The results indicate that it is always possible to fit a single-temperature model during all phases of flares and suggest that the energy in a coronal soft X-ray event is injected on time scales of minutes rather than instantaneously.

Parkinson, J. H.↗

Silicon X-ray line emission from solar flares and active regions

New observations of solar flare and active region X-ray spectra obtained with the Columbia University instrument on OSO-8 are presented and discussed. The high sensitivity of the graphite crystal panel has allowed both line and continuum spectra to be served with moderate spectral resolution. Observations with higher spectral resolution have been made with a panel of pentaerythritol crystals. Twenty-nine lines between 1.5 and 7.0 A have been resolved and identified, including several dielectronic recombination satellite lines to Si XIV and Si XIII lines which have been observed for the first time. It has been found that thermal continuum models specified by single values of temperature and emission measure have fitted the data adequately, there being good agreement with the values of these parameters derived from line intensity ratios.

Parkinson, J. H.↗

The Stellar X-ray Polarimeter - A focal plane polarimeter for the Spectrum X-Gamma mission

This paper describes an X-ray polarimeter that will be flown on the Spectrum X-Gamma mission. The instrument exploits three distinct physical processes to measure polarization: Bragg reflection from a graphite crystal, Thomson scattering from a metallic lithium target, and photoemission from a cesium iodide photocathode. These three methods allow polarization measurements over an energy band from 0.3 to 12 keV. The polarimeter will make possible sensitive measurements of several hundred known X-ray sources. X-ray polarization measurements will make it possible to constrain the geometry of gas flow in X-ray binaries, identify nonthermal emission in supernova remnants, test current models for X-ray emission in radio pulsars, determine the radiation mechanisms in active galactic nuclei, and search for inertial frame dragging (Lense-Thirring effect) around the putative black hole in Cygnus X-1.

Kaaret, P.↗

Presolar (?) corundum in the Orgueil meteorite

The discovery in chondritic meteorites of diamond, SiC, and poorly crystallized graphite that formed around other stars demonstrated conclusively that presolar dust survived the formation of the solar system to be incorporated into meteorites. The presolar nature of these grains is shown by the highly unusual isotopic compositions of their constituent elements. To date, all recognized types of presolar grains have been carbon rich and apparently formed around carbon stars, those with C/O greater than 1. The discovery of the first oxygen-rich grain with isotopic characteristics consistent with a presolar origin is reported. Oxygen-rich grains presumably form only around stars with C/O less than 1.

Huss, G. R.↗

SXRP - An X-ray polarimeter for the SPECTRUM-X-Gamma mission

The Stellar X-ray Polarimeter (SXRP) is a focal plane instrument which will be flown on the SPECTRUM-X-Gamma mission in 1993. The polarimeter is composed of two separate instruments: the first exploits the dependence on the polarization of the Bragg reflection from a graphite crystal, and of the Thomson scattering from a metallic lithium target. The second instrument makes use of the recently discovered polarization dependence of X-ray photoemission from CsI. The SXRP will permit sensitive measurements of several classes of galactic X-ray sources, such as X-ray pulsars, black-hole candidates and supernova remnants. Moreover, and for the first time, SXRP will be able to perform highly sensitive measurements of the brightest extragalactic sources.

Costa, E.↗

High Temperature Chemistry in the Columbia Accident Investigation

Initial estimates on the temperature and conditions of the breach in Columbia's wing focused on analyses of the slag deposits. These deposits are complex mixtures of the reinforced carbon/carbon (RCC) constituents, insulation material, and wing structural materials. However it was possible to clearly discern melted/solidified Cerachrome(R) insulation, indicating the temperatures had exceeded 1760 C. Current research focuses on the carbon/carbon in the path from the breach. Carbon morphology indicates heavy oxidation and erosion. Raman spectroscopy yielded further temperature estimates. A technique developed at Sandia National Laboratories is based on crystallite size in carbon chars. Lower temperatures yield nanocrystalline graphite; whereas higher temperatures yield larger graphite crystals. By comparison to standards the temperatures on the recovered RCC fragments were estimated to have been greater than 2700 C.

Jacobson, Nathan↗

Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays

Graphene is a single atomic layer of graphite. It is optically transparent and has high electron mobility, and thus has great potential to make transparent conductive electrodes. This invention contributes towards the development of graphene transparent conductive electrodes for next-generation microshutter arrays. The original design for the electrodes of the next generation of microshutters uses indium-tin-oxide (ITO) as the electrode material. ITO is widely used in NASA flight missions. The optical transparency of ITO is limited, and the material is brittle. Also, ITO has been getting more expensive in recent years. The objective of the invention is to develop a graphene transparent conductive electrode that will replace ITO. An exfoliation procedure was developed to make graphene out of graphite crystals. In addition, large areas of single-layer graphene were produced using low-pressure chemical vapor deposition (LPCVD) with high optical transparency. A special graphene transport procedure was developed for transferring graphene from copper substrates to arbitrary substrates. The concept is to grow large-size graphene sheets using the LPCVD system through chemical reaction, transfer the graphene film to a substrate, dope graphene to reduce the sheet resistance, and pattern the film to the dimension of the electrodes in the microshutter array. Graphene transparent conductive electrodes are expected to have a transparency of 97.7%. This covers the electromagnetic spectrum from UV to IR. In comparison, ITO electrodes currently used in microshutter arrays have 85% transparency in mid-IR, and suffer from dramatic transparency drop at a wavelength of near-IR or shorter. Thus, graphene also has potential application as transparent conductive electrodes for Schottky photodiodes in the UV region.

Li, Mary↗

Session 3: Irradiation and Thermal Stesses - NRC Graphite Behavior Model

Graphite anisotropic microstructure Graphite crystal structure and basal planes Response to irradiation and temperature C-axis and a-axis behavior The effect of porosity Nano-and micro-length scale Microscopic to macroscopic response Material property changes Defect length-scale factors Internal stress build-up Irradiation induced dimensional change Temperature effects Stress increases & property changes

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Graphite

The basis for graphite in nuclear core components. Why graphite, what makes it tick, what is it's behavior, and some speculation on graphite behavior. How does graphite fit into the discussion for different types of reactors and what types of reactors are considering graphite. The importance of graphite for future reactor designs and what work needs to be conducted in characterizing nuclear graphite.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗