Liquid crystals detect voids in fiber glass laminates

Liquid crystal solution nondestructively detects voids or poor bond lines in fiber glass laminates. A thin coating of the solution is applied by spray or brush to the test article surface, and when heated indicates the exact location of defects by differences in color.

Hollar, W. T.↗

Design Guide for glass fiber reinforced metal pressure vessel

Design Guide has been prepared for pressure vessel engineers concerned with specific glass fiber reinforced metal tank design or general tank tradeoff study. Design philosophy, general equations, and curves are provided for safelife design of tanks operating under anticipated space shuttle service conditions.

Landes, R. E.↗

Glass-fiber-reinforced polymeric film as an efficient protecting layer for stable Li metal electrodes

With numerous reports on protecting films for stable lithium (Li) metal electrodes, the key attributes for how to construct these efficient layers have rarely been fully investigated. Here, we report a rationally designed hybrid protective layer (HPL) with each component aligning with one key attribute; i.e., cross-linked poly(dimethylsiloxane) (PDMS) enhances flexibility, polyethylene glycol (PEG) provides homogeneous ion-conducting channels, and glass fiber (GF) affords mechanical robustness. A significant improvement of the electrochemical performance of HPL-modified electrodes can be achieved in Li/HPL@Cu half cells, HPL@Li/HPL@Li symmetric cells, and HPL@Li/LiFePO 4 full cells. Even with an industrial standard LiFePO 4 cathode (96.8 wt % active material), the assembled cell still exhibits a capacity retention of 90% after 100 cycles at 1 C. More importantly, the functionality of each component has been studied comprehensively via electrochemical and physical experiments and simulations, which will provide useful guidance on how to construct efficient protective layers for next-generation energy storage devices.

25 ENERGY STORAGE↗

Glass Fiber Reinforced Metal Pressure Vessel Design Guide

The Engineering Guide presents curves and general equations for safelife design of lightweight glass fiber reinforced (GFR) metal pressure vessels operating under anticipated Space Shuttle service conditions. The high composite vessel weight efficiency is shown to be relatively insensitive to shape, providing increased flexibility to designers establishing spacecraft configurations. Spheres, oblate speroids, and cylinders constructed of GFR Inconel X-750, 2219-T62 aluminum, and cryoformed 301 stainless steel are covered; design parameters and performance efficiencies for each configuration are compared at ambient and cryogenic temperature for an operating pressure range of 690 to 2760 N/sq cm (1000 to 4000 psi). Design variables are presented as a function of metal shell operating to sizing (proof) stress ratios for use with fracture mechanics data generated under a separate task of this program.

Landes, R. E.↗

Effects of Heat Flux, Oxygen Concentration and Glass Fiber Volume Fraction on Pyrolysate Mass Flux from Composite Solids

Experimental work on the effects of heat flux, oxygen concentration and glass fiber volume fraction on pyrolysate mass flux from samples of polypropylene/glass fiber composite (PP/G) is underway. The research is conducted as part of a larger project to develop a test methodology for flammability of materials, particularly composites, in the microgravity and variable oxygen concentration environment of spacecraft and space structures. Samples of PP/G sized at 30x30x10 mm are flush mounted in a flow tunnel, which provides a flow of oxidizer over the surface of the samples at a fixed value of 1 m/s and oxygen concentrations varying between 18 and 30%. Each sample is exposed to a constant external radiant heat flux at a given value, which varies between tests from 10 to 24 kW/m2. Continuous sample mass loss and surface temperature measurements are recorded for each test. Some tests are conducted with an igniter and some are not. In the former case, the research goal is to quantify the critical mass flux at ignition for the various environmental and material conditions described above. The later case generates a wider range of mass flux rates than those seen prior to ignition, providing an opportunity to examine the protective effects of blowing on oxidative pyrolysis and heating of the surface. Graphs of surface temperature and sample mass loss vs. time for samples of 30% PPG at oxygen concentrations of 18 and 21% are presented in the figures below. These figures give a clear indication of the lower pyrolysis rate and extended time to ignition that accompany a lower oxygen concentration. Analysis of the mass flux rate at the time of ignition gives good repeatability but requires further work to provide a clear indication of mass flux trends accompanying changes in environmental and material properties.

Rich, D. B.↗

Effects of Heat Flux, Oxygen Concentration and Glass Fiber Volume Fraction on Pyrolysate Mass Flux from Composite Solids

Experimental work on the effects of heat flux, oxygen concentration and glass fiber volume fraction on pyrolysate mass flux from samples of polypropylene/glass fiber composite (PP/G) is underway. The research is conducted as part of a larger project to develop a test methodology for flammability of materials, particularly composites, in the microgravity and variable oxygen concentration environment of spacecraft and space structures. Samples of PP/G sized at 30 x 30 x 10 mm are flush mounted in a flow tunnel, which provides a flow of oxidizer over the surface of the samples at a fixed value of 1 m/s and oxygen concentrations varying between 18 and 30%. Each sample is exposed to a constant external radiant heat flux at a given value, which varies between tests from 10 to 24 kW/sq m. Continuous sample mass loss and surface temperature measurements are recorded for each test. Some tests are conducted with an igniter and some are not. In the former case, the research goal is to quantify the critical mass flux at ignition for the various environmental and material conditions described above. The later case generates a wider range of mass flux rates than those seen prior to ignition, providing an opportunity to examine the protective effects of blowing on oxidative pyrolysis and heating of the surface. Graphs of surface temperature and sample mass loss vs. time for samples of 30% PPG at oxygen concentrations of 18 and 21% are presented in the figures below. These figures give a clear indication of the lower pyrolysis rate and extended time to ignition that accompany a lower oxygen concentration. Analysis of the mass flux rate at the time of ignition gives good repeatability but requires further work to provide a clear indication of mass flux trends accompanying changes in environmental and material properties.

Rich, D. B.↗

Low thermal flux glass-fiber tubing for cryogenic service.

Study of thin metallic liners which provide leak-free service in cryogenic propulsion plumbing systems and are overwrapped with a glass-fiber composite that provides strength and protection from handling damage. The composite tube is lightweight, strong, and has a very low thermal flux. The resultant reduced boiloff of stored cryogenic propellants yields a substantial weight savings for long-term missions (seven days or greater). Twelve styles of tubing ranging from 1/2 to 5 in. in diameter were fabricated and tested with excellent results for most of the concepts at operating temperatures from +70 to -423 F and operating pressures up to 3000 psi.

Hall, C. A.↗

Supersonic Panel Flutter Test Results for Flat Fiber-Glass Sandwich Panels with Foamed Cores

Flutter tests have been made on flat panels having a 1/4 inch-thick plastic-foam core covered with thin fiber-glass laminates. The testing was done in the Langley Unitary Plan wind tunnel at Mach numbers from 1.76 t o 2.87. The flutter boundary for these panels was found to be near the flutter boundary of thin metal panels when compared on the basis of an equivalent panel stiffness. The results also demonstrated that the depth of the cavity behind the panel has a pronounced influence on flutter. Changing the cavity depth from 1 1/2 inches to 1/2 inch reduced the dynamic pressure at start of flutter by 40 percent. No flutter was obtained when the spacers on the back of the panel were against the bottom of the cavity.

Tuovila, W. J.↗

Deposition Of Thin-Film Sensors On Glass-Fiber/Epoxy Models

Direct-deposition process devised for fabrication of thin-film sensors on three-dimensional, curved surfaces of models made of stainless steel covered with glass-fiber/epoxy-matrix composite material. Models used under cryogenic conditions, and sensors used to detect on-line transitions between laminar and turbulent flows in wind tunnel environments. Sensors fabricated by process used at temperatures from minus 300 degrees F to 175 degrees F.

Tran, Sang Q.↗

Making Glass-Fiber-Reinforced Coolant Tubes

New use found for heat-shrinkable sleeves. Smooth, noncontaminating channels for transporting cooling water in Space Shuttle Extravehicularmobility unit made of fiberglass tubing with aid of heat-shrinkable sleeves. Previously, glass fibers from inner walls of tubes contaminate water.

Curtin, F.↗

Self-Frequency-Doubling Glass-Fiber Laser

Specially prepared germanium and phosphorous-doped glass optical fiber doped with neodymium shown to act as self-frequency-doubling laser. Self-frequency-doubling fiber laser with further refinements, eliminates need for expensive, easily damaged, nonlinear crystals currently used. Enables one to avoid loss and damage mechanisms associated with interfaces of nonlinear crystals as well as to eliminate angle/temperature phase-matching tuning.

Selker, Mark D.↗

Polyimide fiber-glass composite resists high temperatures

Composites synthesized from bismaleimide have superior strength and oxidation resistance at elevated temperatures when compared with similar composites prepared with epoxy or silicon polymers of similar cost. Polyimide synthesis technique and processing method yield essentially void-free fiber-glass reinforced composites.

Gilwee, W. J.↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Ferrule and use thereof for cooling a melt spun hollow glass fiber as it emerges from a spinnerette

An improvement in the process of melt spinning thin walled, hollow fibers from relatively low melting glasses results if cooling of the emerging fiber is accomplished by use of a thin layer of gas to transfer heat from the fiber to a ferrule which fits closely to the spinnerette face and the individual fiber. The ferrule incorporates or is in contact with a heat sink and is slotted or segmented so that it may be brought into position around the moving fiber. Thinner walled, more uniform fibers may be spun when this method of cooling is employed.