Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “generation mix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Life-cycle assessment of greenhouse gas and air emissions of electric vehicles: A comparison between China and the U.S.

We evaluated the fuel-cycle emissions of greenhouse gases (GHGs) and air pollutants (NOx, SO2, PM10, and PM2.5) of electric vehicles (EVs) in China and the United States (U.S.), two of the largest potential markets for EVs in the world. Six of the most economically developed and populated regions in China and the U.S. were selected. The results showed that EV fuel-cycle emissions depend substantially on the carbon intensity and cleanness of the electricity mix, and vary significantly across the regions studied. In those regions with a low share of coal-based electricity (e.g., California), EVs can reduce GHG and air pollutant emissions (except for PM) significantly compared with conventional vehicles. However, in the Chinese regions and selected U.S. Midwestern states where coal dominates in the generation mix, EVs can reduce GHG emissions but increase the total and urban emissions of air pollutants. In 2025, EVs will offer greater reductions in GHG and air pollutant emissions because emissions from power plants will be better controlled; EVs in the Chinese regions examined, however, may still increase SO2 and PM emissions. Reductions of 60–85% in GHGs and air pollutants could be achieved were EVs charged with 80% renewable electricity or the electricity generated from the best available technologies of coal-fired power plants, which are futuristic power generation scenarios.

Electric vehicles↗

Generation of tunable and broadband far-infrared laser pulses during two-color filamentation

Tunable far-infrared laser pulses were generated efficiently during two-color filamentation in air. Understanding the creation of few-cycle far-infrared laser pulses is important since it is at the frontier between two possible generation mechanisms. The first one is the four-wave mixing generation, associated to the generation of wavelengths from ultraviolet up to mid-infrared laser pulses. The second process is the formation of transient photocurrent, which was recently used to describe the generation of submillimetric (terahertz) waves. Comparison between experiments and simulations revealed that the four-wave mixing mechanism is dominant for the far-infrared generation during two-color filamentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for leptoquark pair production decaying into $te^- \bar{t}e^+$ or $t\mu ^- \bar{t}\mu ^+$ in multi-lepton final states in pp collisions at $\sqrt{s} = 13\,\textrm{TeV}$ with the ATLAS detector

A search for leptoquark pair production decaying into $te^- \bar{t}e^+$ or $t\mu ^- \bar{t}\mu ^+$ in final states with multiple leptons is presented. The search is based on a dataset of pp collisions at $\sqrt{s}=13~\text {TeV}$ recorded with the ATLAS detector during Run 2 of the Large Hadron Collider, corresponding to an integrated luminosity of 139 fb -1 . Four signal regions, with the requirement of at least three light leptons (electron or muon) and at least two jets out of which at least one jet is identified as coming from a b-hadron, are considered based on the number of leptons of a given flavour. The main background processes are estimated using dedicated control regions in a simultaneous fit with the signal regions to data. No excess above the Standard Model background prediction is observed and 95% confidence level limits on the production cross section times branching ratio are derived as a function of the leptoquark mass. Under the assumption of exclusive decays into $te^{-}$ ($t\mu ^{-}$ ), the corresponding lower limit on the scalar mixed-generation leptoquark mass $m_{\textrm{LQ}_{\textrm{mix}}^{\textrm{d}}}$ is at 1.58 (1.59) TeV and on the vector leptoquark mass $m_{{\tilde{U}}_1}$ at 1.67 (1.67) TeV in the minimal coupling scenario and at 1.95 (1.95) TeV in the Yang–Mills scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comprehensive Well to Wheel Analysis for Plug-in-Hybrid Electric Vehicles in the U.S.

The U.S. electric power infrastructure is a strategic national asset that is underutilized most of the time. With the proper changes in the operational paradigm, it could generate and deliver the necessary energy to fuel the majority of the U.S. light-duty vehicle (LDV) fleet. In doing so, it would reduce greenhouse gas emissions, improve the economics of the electricity industry, and reduce the U.S. dependency on foreign oil. This paper estimates the regional percentages of the energy requirements for the U.S. LDV stock that could potentially be supported by the existing infrastructure, based on the 12 modified North American Electric Reliability Council regions, as of 2002. For the United States as a whole, about 70% of LDV fleet in the U.S. could be supported by the existing infrastructure with some degree of load management. This has an estimated gasoline displacement potential of 6.5 million barrels of oil equivalent per day, or approximately 52% of the nation's oil imports. The paper also discusses the impact on overall emissions of criteria gases and greenhouse gases as a result of shifting emissions from millions of individual vehicles to a few hundred power plants. Overall, PHEVs could reduce greenhouse gas emissions with regional variations dependent on the local generation mix. Total NOX emissions may or may not increase, dependent on the use of coal generation in the region. Any additional SO2 emissions associated with the expected increase in generation from coal power plants would need to be cleaned up to meet the existing SO2 emissions constraints. Particulate emissions would increase in 8 of the 12 regions. The emissions in urban areas are found to improve across all pollutants and regions as the emission sources shift from millions of tailpipes to a smaller number of large power plants in less-populated areas. This paper concludes with a discussion about possible grid impacts as a result of the PHEV load as well as the likely impacts on the plant and technology mix of future generation-capacity expansions.

01 COAL, LIGNITE, AND PEAT↗

Production and Transformation of Mixed-Valent Nanoparticles Generated by Fe(0) Electrocoagulation

Mixed-valent iron nanoparticles (NP) generated electrochemically by Fe(0) electrocoagulation (EC) show promise for on-demand industrial and drinking water treatment in engineered systems. This work applies multiple characterization techniques (in situ Raman spectroscopy, XRD, SEM, and cryo-TEM) to investigate the formation and persistence of magnetite and green rust (GR) NP phases produced via the Fe(0) EC process. Current density and background electrolyte composition were examined in a controlled anaerobic system to determine the initial Fe phases generated as well as transformation products with aging. Fe phases were characterized in an aerobic EC system with both simple model electrolytes and real groundwater to investigate the formation and aging of Fe phases produced in a system representing treatment of arsenic-contaminated ground waters in South Asia. Two central pathways for magnetite production via Fe(0) EC were identified: (i) as a primary product (formation within seconds when DO absent, no intermediates detected) and (ii) as a transformation product of GR (from minutes to days depending on pH, electrolyte composition, and aging conditions). Furthermore, this study provides a better understanding of the formation conditions of magnetite, GR, and ferric (oxyhydr)oxides in Fe EC, which is essential for process optimization for varying source waters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Behind-the-Meter Solar Accounting in Renewable Portfolio Standards

If a behind-the-meter solar photovoltaic (BTM PV) system is adopted, how does that influence the total amount of renewable electricity in its state in the long run (i.e., after the existence of the generator is reflected in the relevant utility's generation mix)? Would we expect the total amount of renewable generation to increase on a 1:1 basis with the BTM PV's generation? Or could it be something more, or something less? We show in this paper that the answer can depend on two key elements of how BTM PV is accounted for in a state’s renewable portfolio standard (RPS): (1) whether renewable energy certificates (RECs) from BTM PV can be used for RPS compliance, and (2) whether load served by generation from BTM PV counts as load covered by the RPS. These two elements combine into four possible accounting options, and we characterize the implications of each under the simplifying assumptions that the RPS is binding and the BTM PV RECs are used for compliance when allowed. For example, if load served by BTM PV generation counts toward the RPS load and BTM PV RECs cannot be used for compliance, the presence of BTM does not change the amount of RECs that the utility is required to retire, and yet additional RECs will be retired by the BTM PV owner - therefore, the total amount of renewable generation would increase on a 1:1 basis with the BTM PV generation. In contrast, under a common RPS design in which BTM PV RECs can be used for compliance and the load served by BTM PV generation is not covered by the RPS, the presence of BTM PV and transfer of RECs for compliance can actually decrease the total amount of renewable generation in the state, relative to a situation in which there is no BTM PV.

14 SOLAR ENERGY↗

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Addressing energy storage needs at lower cost via on-site thermal energy storage in buildings

Cost-effective energy storage is a critical enabler for the large-scale deployment of renewable electricity. Significant resources have been directed toward developing cost-effective energy storage, with research and development efforts dominated by work on lithium ion (Li-ion) battery technology. Though Li-ion batteries have many attractive qualities, it is not clear whether they can provide an affordable levelized cost of storage (LCOS) for certain applications, such as buildings. Buildings consume most of the world's electricity, and as much as 50% of their consumption goes toward meeting thermal loads. Thermal energy storage (TES) can provide a cost-effective alternative to Li-ion batteries for buildings; however, two questions remain to be answered. First, how much of total building energy storage requirements can be met via thermal storage for building loads? Second, can the LCOS for TES be favorable compared with Li-ion batteries? In this perspective, using the United States as a case study, we show that the total requirement for TES in buildings is in the range of ~1200–4500 electrical GW h, depending on the fraction of solar versus wind in the generation mix. Furthermore, we show that with at least 25% wind generation, all of the storage needed by buildings to support the grid can be met by TES. We also introduce a framework to calculate LCOS for on-site TES in buildings to enable a direct comparison with electrical storage technologies such as Li-ion batteries. This is not trivial, because the input energy type for TES (electricity) differs from the output energy type (thermal energy), and the efficiency can depend on ambient conditions. Our LCOS analysis shows that in many situations, TES can be more cost-effective for buildings than Li-ion batteries. We conclude our perspective by discussing future research and development opportunities that can significantly advance the deployment of TES for buildings to help enable a renewable electricity-dependent grid.

25 ENERGY STORAGE↗

Chapter 9: Impact of Variable Renewable Energy Sources on Bulk Power System Planning and Operations

Wind and solar photovoltaics (PV) have experienced remarkable growth in recent years, with many consequent benefits within and outside of power systems. At the same time, wind and solar PV have unique characteristics relative to the historically dominant dispatchable technologies like coal, gas, and nuclear power plants that have required and will continue to require changes in power system planning and operations. This chapter discusses planning and operational challenges of integrating wind and solar PV into bulk power systems. We first present the key characteristics of wind and solar PV that differentiate it from conventional technologies, such as variable and uncertain electricity generation, asynchronous interconnection to the power system, and near-zero marginal costs. We then link these characteristics to power system planning and operational challenges at low through high wind and solar penetrations. Finally, we discuss near- and long-term solutions to those challenges, such as diversifying the generation mix and wind and solar fleets, improving system flexibility, diversifying ancillary service products, and integrating generation and transmission planning.

bulk power system↗

The IEEE Reliability Test System: A Proposed 2019 Update

The evolving nature of electricity production, transmission and consumption necessitates an update to the IEEE's Reliability Test System, which was last modernized in 1996. The update introduced here introduces a generation mix more representative of modern power systems, with the removal of several nuclear and oil generating units and the addition of natural gas, wind, solar photovoltaics, concentrating solar power, and energy storage. The update includes assigning the test system a geographic location in the southwestern United States to enable the integration of spatio-temporally consistent wind, solar, and load data with forecasts. Further updates include common RTS transmission modifications in published literature, definitions for reserve product requirements and market simulation descriptions to enable benchmarking of multi-period power system scheduling problems. The final section reflects example results from a production cost modeling simulation on the updated RTS system data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Singlet generation in mixed-state quantum networks

We study the generation of singlets in quantum networks with nodes initially sharing a finite number of partially entangled bipartite mixed states. We prove that singlets between arbitrary nodes in such networks can be created if and only if the initial states connecting the nodes have a particular form. We then generalize the method of entanglement percolation, previously developed for pure states, to mixed states of this form. As part of this, we find and compare different distillation protocols necessary to convert groups of mixed states shared between neighboring nodes of the network into singlets. In addition, we discuss protocols that only rely on local rules for the efficient connection of two remote nodes in the network via entanglement swapping. Further improvements of the success probability of singlet generation are developed by using particular forms of ''quantum preprocessing'' on the network. This includes generalized forms of entanglement swapping and we show how such strategies can be embedded in regular and hierarchical quantum networks.

74 ATOMIC AND MOLECULAR PHYSICS↗

Realistic model for SU(5) grand unification

A grand unified model based on SU(5) and supersymmetry is presented. Pairs of superfields belonging to 15 and 15 representations are newly introduced, two pairs with even and one pair with odd matter parity. Improper mass relations in the minimal model between charged leptons and d-type quarks are corrected. Neutrinos have nonvanishing masses, with large angles for generation mixings of the leptons being compatible with the small angles of the quarks. A new source for lepton-number generation in the early universe is provided.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental and analytical evaluation of a hydro-pneumatic compressed-air Ground-Level Integrated Diverse Energy Storage (GLIDES) system

In recent times, there has been a significant increase in intermittent renewable electricity capacity additions to the generation mix. This, coupled with an aging electrical grid that is poorly equipped to handle the ensuing mismatch between generation and use, has created a strong need for flexible, advanced bulk energy storage technologies. In this paper, one such technology recently invented and demonstrated at Oak Ridge National Laboratory is introduced and characterized. Similar to compressed-air energy storage, the Ground-Level Integrated Diverse Energy Storage (GLIDES) technology is based on gas compression/expansion, however, liquid-piston compression and expansion are utilized. In common with pumped-storage hydroelectricity, hydraulic turbomachines (pump/turbine) are utilized for energy storage and recovery, however, pressure vessels are utilized to create artificial elevation (head) difference, allowing pressure head of several thousands of feet to be reached. Furthermore, this paper reports on the experimental performance of the first GLIDES proof-of-concept prototype, and presents formulation and results from a validated physics-based simulation model.

25 ENERGY STORAGE↗

On dynamics of fermion generations

The hierarchy of fermion masses and electroweak (EW) symmetry breaking without elementary Higgs is studied on the basis of strong gauge-field distributions governing the EW dynamics. The mechanism of symmetry breaking due to quark bilinear condensation is generalized to the case, when higher field correlators are present in the EW vacuum. Resulting wave functional yields several minima of quark bilinears, giving masses of three (or more) generations. Mixing is suggested to be due to kink solutions of the same wave functional. For a special form of this mixing ('coherent mixing') a realistic hierarhy of masses and CKM coefficients is obtained and arguments in favor of the fourth generation are given. Possible important role of topological charges for CP-violating phases and small masses of the first generation is stressed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conventional Generation Asset Management with Renewable Portfolio Standards Using Real Options

The transition to a more renewable generation mix under a competitive electricity market will require individual power producers to use sophisticated tools to value conventional generators. Owners will need to understand what market prices signal new investments, temporarily suspending operation, reactivating mothballed generators or permanently abandoning a plant. Net present valuation from a traditional discounted cash flow analysis is limited in capturing the value of generation technologies, and it does not provide an optimal investment criterion. We present and evaluate a closed-form decision support framework using a Spark Spread Real Options approach to value generation assets and to capture optimal market price signals that minimizes financial risks of individual power producers under a transition towards a more renewable energy fleet. We evaluate the Spark Spread options valuation for capital budgeting without capacity payments. As an example, for a fixed heat rate of 10,000 Btu/kWh and a combined electricity and fuel price annual volatility1 of 58%, the Spark Spread option valuation gives a positive value for a unit of installed generating capacity at electricity prices below $\$$40/MWh. Given the same conditions, a traditional net present value (NPV) cash flow has no value for a unit of installed capacity for electricity prices below $\$$40/MWh. Accounting for the inevitable volatility in electricity and fuel prices can allow firms to see more value in fossil plants than does the traditional approach.

17 WIND ENERGY↗

A flavorful factoring of the strong CP problem

Motivated by the intimate connection between the strong CP problem and the flavor structure of the Standard Model, we present a flavor model that revives and extends the classic ${m_u=0}$ solution to the strong CP problem. QCD is embedded into a $SU(3)_1\times SU(3)_2 \times SU(3)_3$ gauge group, with each generation of quarks charged under the respective $SU(3)$. The non-zero value of the up-quark Yukawa coupling (along with the strange quark and bottom-quark Yukawas) is generated by contributions from small instantons at a new scale $M \gg \Lambda_{QCD}$. The Higgsing of $SU(3)^3\to SU(3)_c$ allows dimension-5 operators that generate the Standard Model flavor structure and can be completed in a simple renormalizable theory. The smallness of the third generation mixing angles can naturally emerge in this picture, and is connected to the smallness of threshold corrections to $\bar\theta$. Remarkably, $\bar\theta$ is essentially fixed by the measured quark masses and mixings, and is estimated to be close to the current experimental bound and well within reach of the next generation of neutron and proton EDM experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗