Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “general submillimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

57 records · Page 4

Tunable Far Infrared Studies in Support of Stratospheric Measurements

This report summarizes research done under NASA Grant NAG5-4653. The research performed under this grant has been a collaboration between institutions including the Smithsonian Astrophysical Observatory, the National Institute of Standards and Technology, the University of Oregon, and the NASA Langley Research Center. The program has included fully line-resolved measurements of submillimeter and far infrared spectroscopic line parameters (pressure broadening coefficients and their temperature dependences, and line positions) for the analysis of field measurements of stratospheric constituents, far infrared database improvements, and studies for improved satellite measurements of the Earth's atmosphere. This research program is designed to enable the full utilization of spectra obtained in far infrared/submillimeter field measurements, such as FIRS-2, FILOS, IBEX, SLS, EosMLS, and proposed European Space Agency measurements of OH (e.g., PIRAMHYD and SFINX) for the retrieval of accurate stratospheric altitude profiles of key trace gases involved in ozone layer photochemistry. For the analysis of the spectra obtained in the stratosphere from far infrared measurements it is necessary to have accurate values of the molecular parameters (line positions, strengths, and pressure broadening coefficients) for the measured molecules and for possible interfering species. Knowledge of line positions is in increasingly good shape, with some notable exceptions. The increase in position information includes research that has been performed in the present program of research on HO2, H2O, H2O2, O3, HCl, HF, HBr, HI, CO, OH, and ClO. Examples where further line position studies are necessary include hot band and minor isotopomer lines of some of the major trace species (H2O, O3) and normal lines of some triatomic and larger molecules (NO2). Knowledge of strengths is in generally good shape, since most of the lines are from electric dipole transitions whose intensities are well determined from Stark effect measurements; exceptions include some molecules with large vibration-rotation interactions (NO2) and internal motions (H2O2 above the lowest torsional state). The line parameters that are still the least well determined are pressure broadening coefficients, and their temperature coefficients, These are strongly dependent on the quantum states involved in the transitions, in a way that is much more complex than the simple projection by directional cosine matrix elements involved in determination of rotational line strengths from static dipole moments. The following molecules have now been measured or detected in the atmosphere using far infrared and millimeter-wave emission spectroscopy from balloon- and satellite-borne spectrometers: OH, HO2, H2O (including minor isotopomers and hot band lines), H2O2, O3P, O2 (including minor isotopomers), O3 (including minor isotopomers and hot band lines), HOCl, HCl, HF, HBr, CIO, CO, CO2, N2O, NO2, N2O5, HNO3, ClNO3, and HCN. Many of these species have spectral lines that are saturated in stratospheric spectra. In these cases, the measured line equivalent widths are proportional to (line strength x Lorentz width) (exp 1/2) so that the pressure broadening coefficients are as important as the line intensities in determining concentration profiles. Interpretation of field measurements for these species have required ongoing measurement programs of pressure broadening measurements. Other species (HO2, HGCl, H2O2, HBr, and NO2, as examples) have required further line position studies in order to fully analyze the field measurements.

Chance, Kelly V.↗

Hydrogen Peroxide-Water-Ethanol-Monopropellant Blend for CubeSat Propulsion

Monopropellant propulsion that provides high performance and low hazards compared to state-of-art hydrazine are being investigated under NASA, DOD and commercially sponsored green propellant research and development programs. This NASAeffort looks at phosphate stabilized 50% hydrogen peroxide/water –ethanol blends to evaluate their stability and combustion behavior in submillimeter diameter microtube combustion apparatus for cubesat propulsion applications. Exploratory 7-day stabilitytests find no pressure rise in a sealed test tube environment at room temperature indicating at least short term stability of the mixture. Temperature rise during combustion testing in resistively heated nickel microtube apparatus shows that micro-combustion is achieved in the tube. Propellant density is approximately 1.2 g/cm3compared to 1.0 g/cm3for hydrazine. Theoretical specific impulse of the stoichiometric blend is 219 s at a chamber pressure of 20 psia and an area ratio of 30:1. Density-specific impulseof this blendis263 swhile hydrazine is only about 215-220 sin small reaction control system thrusters. This provides about 20-22% more density-specific impulse for the cubesat compared to hydrazine. The theoreticalcombustion temperature is2168°F, whichis thermally compatible with stainless steel materials of constructionand the nickel catalystused in the tests. Combustion test results are given for stoichiometric, as well as fuel-leanand fuel-richpropellant formulations. Thesetests focus on thermally and catalytically supported combustionin the microtube, whichrequires a microtube preheat temperature of about 900°F and sufficient residence time to achieve combustion that is stable and anchored in the tubewithout blowing through the tube unreacted. Thrust class is expected to be in the 10 mN range based on flow rate and estimated specific impulse.Power requirements are generally below 25 Wto heat the tube. Steady state combustion testing is typically conducted for 3 minutes and shows littledegradation of the hardware over multiple test cyclesindicating thatthere is little catalyst degradation over time and littlecatalyst deactivation due tothe phosphate stabilizer inthe hydrogen peroxide.

Monopropellant↗

Hydrogen Peroxide-Water-Ethanol Monopropellant Blend for CubeSat Propulsion

Monopropellant propulsion that provides high performance and low hazards compared to state-of-art hydrazine are being investigated under NASA, DOD and commercially sponsored green propellant research and development programs. This NASA effort looks at phosphate stabilized 50% hydrogen peroxide/water –ethanol blends to evaluate their stability and combustion behavior in submillimeter diameter microtube combustion apparatus for cubesat propulsion applications. Exploratory 7-day stability tests find no pressure rise in a sealed test tube environment at room temperature indicating at least short term stability of the mixture. Temperature rise during combustion testing in resistively heated nickel microtube apparatus shows that micro-combustion is achieved in the tube. Propellant density is approximately 1.2 g/cu.cm compared to 1.0 g/cu.cm for hydrazine. Theoretical specific impulse of the stoichiometric blend is 219 s at a chamber pressure of 20 psia and an area ratio of 30:1. Density-specific impulse of this blend is 263 s while hydrazine is only about 215-220 s in small reaction control system thrusters. This provides about 20-22% more density-specific impulse for the cube sat compared to hydrazine. The the oretical combustion temperature is 2168°F, which is thermally compatible with stainless steel materials of construction and the nickel catalyst used in the tests. Combustion test results are given for stoichiometric, as well as fuel-lean and fuel-rich propellant formulations. These tests focus on thermally and catalytically supported combustion in the microtube, which requires a microtube preheat temperature of about 900°F and sufficient residence time to achieve combustion that is stable and anchored in the tube without blowing through the tube unreacted. Thrust class is expected to be in the 10 m N range based on flow rate and estimated specific impulse. Power requirements are generally below 25 W to heat the tube. Steady state combustion testing is typically conducted for 3 minutes and shows little degradation of the hardware over multiple test cycles indicating that there is little catalyst degradation over time and little catalyst deactivation due to the phosphate stabilizer in the hydrogen peroxide.

Monopropellant↗