Cosmic ray studies with a gas Cherenkov counter in association with an ionization spectrometer

The results from a balloon-borne gas Cherenkov counter (threshold 16.5 GeV/nucleon) and an ionization spectrometer are presented. The gas Cherenkov counter provides an absolute energy distribution for the response of the calorimeter for 5 or = Z 26 nuclei of cosmic rays. The contribution of scintillation to the gas Cherenkov pulse height was obtained by independently selecting particles below the gas Cherenkov threshold using the ionization spectrometer. Energy spectra were derived by minimizing the chi squared between Monte Carlo simulted data and flight data. Best fit power laws, dN/dE = AE-gamma, were determined for C, N, O, Ne, Mg, and Si. The power laws, all consistent with E (-2.7) are not good fits to the data. A better fit is obtained using the spectrum derived from the spectrometer. The data from the ionization calorimeter and the gas Cherenkov are thus completely self-consistent.

Balasubrahmanyan, V. K.↗

Cosmic ray studies with a gas Cerenkov counter in association with an ionization spectrometer

The results from a balloon-borne gas Cerenkov counter (threshold 16.5 GeV/nuc) and an ionization spectrometer are presented. The gas Cerenkov counter provides an absolute energy calibration for the response of the calorimeter for the Z range of 5-26 nuclei of cosmic rays. The contribution of scintillation to the gas Cerenkov pulse height has been obtained by independently selecting particles below the gas Cerenkov threshold using the ionization spectrometer. Energy spectra were derived by minimizing the chi-squared between a Monte Carlo simulated data and flight data. Best fit power laws were determined for C, N, O, Ne, Mg, and Si. The power laws, all consistent with E exp-2.7, are not good fits to the data. A better fit is obtained using the spectrum derived from the spectrometer.

Balasubrahmanyan, V. K.↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗

HgI2 low energy beta particle detector

An HgI2 device structure was designed and tested which allows HgI2 to be used to make low-energy beta-particle detectors. The devices detected tritium beta particles with an efficiency of about 25 percent. A protective encapsulant has been developed which should protect the devices for up to 20 years and will attenuate only a small fraction of the beta particles. It is noted that the devices hold significant promise to provide a practical alternative to liquid scintillation counters and gas flow-through proportional counters.

Shah, K. S.↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Machine learning for single-ended event reconstruction in PROSPECT experiment

The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, was a segmented antineutrino detector that successfully operated at the High Flux Isotope Reactor in Oak Ridge, TN, during its 2018 run. Despite challenges with photomultiplier tube base failures affecting some segments, innovative machine learning approaches were employed to perform position and energy reconstruction, and particle classification. This work highlights the effectiveness of convolutional neural networks and graph convolutional networks in enhancing data analysis. By leveraging these techniques, a 3.3% increase in effective statistics was achieved compared to traditional methods, showcasing their potential to improve analysis performance. Furthermore, these machine learning methodologies offer promising applications for other segmented particle detectors, underscoring their versatility and impact.

47 OTHER INSTRUMENTATION↗

Hydromagnetic wave heating of low density interstellar gas

The origin of the observed wave spectrum for hot gas in the ISM is considered theoretically. The governing equations for the generation, propagation, and dissipation of compressive waves are reviewed, and particular attention is given to the heating of warm neutral gas and the implications for radio-wave scattering. It is shown that little power from interactions between SN shocks and hot coronal gas reaches short wavelengths, and that scintillation probably does not originate in a warm weakly ionized gas.

Zweibel, Ellen G.↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Scintillator ageing of the T2K near detectors from 2010 to 2021

The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9–2.2% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator. The long component of the attenuation length of the wavelength shifting fibres was observed to degrade by 1.3–5.4% per year, while the short component of the attenuation length did not show any conclusive degradation.

47 OTHER INSTRUMENTATION↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

Here, we present results of several measurements of CsI[Na] scintillation response to 3–60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

47 OTHER INSTRUMENTATION↗

Laser calibration of the ATLAS Tile Calorimeter during LHC Run 2

This article reports the laser calibration of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2 data campaign. The upgraded Laser II calibration system is described. The system was commissioned during the first LHC Long Shutdown, exhibiting a stability better than 0.8% for the laser light monitoring. The methods employed to derive the detector calibration factors with data from the laser calibration runs are also detailed. These allowed to correct for the response fluctuations of the 9852 photomultiplier tubes of the Tile Calorimeter with a total uncertainty of 0.5% plus a luminosity-dependent sub-dominant term. Finally, we report the regular monitoring and performance studies using laser events in both standalone runs and during proton collisions. These studies include channel timing and quality inspection, and photomultiplier linearity and response dependence on anode current.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The acrylic vessel for JSNS 2 -II neutrino target

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS 2 -II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. Here, the specifications, design, and measured properties of the acrylic vessel are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a ton-scale water-based liquid scintillator detector

This study reports the performance and light yield of 1% concentration water-based liquid scintillator (WbLS) deployed in a 1000-liter detector. A light yield of 99± 15 photons per MeV is determined by comparing data with simulation. This result aligns with our previous light yield determination using smaller detectors, thus establishing a solid foundation for the ongoing development and deployment of WbLS in larger-scale detectors. In conclusion, the feasibility of in situ preparation and the stability of light yield in WbLS are demonstrated, reinforcing its suitability for long-term experimental endeavors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deployment of Water-based Liquid Scintillator in the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water Cherenkov neutrino detector installed on the Booster Neutrino Beam (BNB) at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is the research and development of new detector technologies and target media. Specifically, water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of Cherenkov light and scintillation. This paper presents the deployment of a 366 L WbLS vessel in ANNIE in March 2023 and the subsequent detection of both Cherenkov light and scintillation from the WbLS. Finally, this proof-of-concept allows for the future development of reconstruction and particle identification algorithms in ANNIE, as well as dedicated analyses within the WbLS volume, such as the search for neutral-current events and the hadronic scintillation component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a bi-solvent liquid scintillator with slow light emission

One of the most promising approaches for the next generation of neutrino experiments is the realization of large hybrid Cherenkov/scintillation detectors made possible by recent innovations in photodetection technology and liquid scintillator chemistry. The development of a potentially suitable future detector liquid with particularly slow light emission is discussed in the present publication. This cocktail is compared with respect to its fundamental characteristics (scintillation efficiency, transparency, and time profile of light emission) with liquid scintillators currently used in large-scale neutrino detectors. In addition, the optimization of the admixture of wavelength shifters for a scintillator with particularly high light emission is presented. Furthermore, the pulse-shape discrimination capabilities of the novel medium was studied using a pulsed particle accelerator driven neutron source. Beyond that, purification methods based on column chromatography and fractional vacuum distillation for the co-solvent DIN (Diisopropylnaphthalene) are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of radiation damage on the light yield and uniformity of candidate plastic scintillator tiles for the CMS hadron calorimeter upgrade

A study has been performed to understand the effects of radiation damage on various plastic scintillator tiles considered for a possible upgrade of the hadron calorimeter of the CMS detector. Measurements were made with unirradiated tiles and with tiles that had been irradiated in the CMS collision hall to a dose of 44 kGy. Results are presented for the tiles of different shapes in terms of the energy spectrum, efficiency as a function of the position at which each tile was hit, as well as light yield. All the tiles showed a light reduction of up to about 50%. The tiles with the shape currently used in the CMS detector did not see increased non-uniformity of light collection, while a significant disuniformity was observed for the tiles considered as alternatives.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of the cosmic ray tagger system for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system (∼ 1100 m 2 ), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗