The interaction between an impact-produced neutral gas cloud and the solar wind at the lunar surface

On Apr. 15, 1970, the Apollo 13 S-IVB stage impacted the nighttime lunar surface. Beginning 20 sec after impact, the Suprathermal Ion Detector Experiment and the Solar Wind Spectrometer observed a large flux of positive ions (maximum flux of about 3 x 10 to the 8th ions/sq cm/sec/ster) and electrons. Two separate streams of ions were observed: a horizontal flux that appeared to be deflected solar wind ions and a smaller vertical flux of predominantly heavy ions (greater than 10 amu), which probably were material vaporized from the S-IVB stage. An examination of the data shows that collisions between neutral molecules and hot electrons (50 eV) were probably an important ionization mechanism in the impact-produced neutral gas cloud. These electrons, which were detected by the Solar Wind Spectrometer, are thought to have been energized in a shock front or some form of intense interaction region between the cloud and the solar wind. Thus strong ionization and acceleration are seen under conditions approaching a collisionless state.

Lindeman, R. A.↗

SRAM As An Array Of Energetic-Ion Detectors

Static random-access memory (SRAM) designed for use as array of energetic-ion detectors. Exploits well-known tendency of incident energetic ions to cause bit flips in cells of electronic memories. Design of ion-detector SRAM involves modifications of standard SRAM design to increase sensitivity to ions. Device fabricated by use of conventional complementary metal oxide/semiconductor (CMOS) processes. Potential uses include gas densimetry, position sensing, and measurement of cosmic-ray spectrum.

Buehler, Martin G.↗

An experiment to study the nuclear component of primary cosmic rays

An apparatus has been designed and is being fabricated to study the charge composition, fluxes, and energy spectra of light nuclei in the energy region from 1 GeV to 100 GeV. The apparatus essentially consists of an array of a large number of particle detectors operated in coincidence and serving as a charged particle telescope. A mosaic silicon semiconductor detector, a plastic scintillation counter and a lucite Cerenkov detector are used to measure the charges of the incident nuclei. Two one-inch thick CsI detectors are used to study low energy particles. An ionization spectrometer is utilized to measure primary energies in the 1 to 100 GeV energy interval. A gas Cerenkov counter is being designed to distinguish between electrons and protons. It is planned to calibrate the apparatus at an accelerator using particles of known energy.

Paul, J. M.↗

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

Laboratory Investigation of the Effect of Venusian Weathering on Mineral Spectra

Introduction: The recent selection of two missions to Venus has renewed the importance of deter-mining weathering reactions between minerals and the Venusian atmosphere, and the spectral signatures of minerals before, during, and after these reactions. The rate at which weathering reactions progress also constrain show long unstable minerals will be present on the surface (e.g., [1]), and enables the use of mineralogy as a constraint on surface age(e.g., [2-3]).In order to gain an understanding of how mineral compositions and spectra change with weathering, we have begun conducting experiments in a 1 atm experimental setup at Wesleyan University. This setup exposes minerals to the temperature and most abundant gases of the Venus atmosphere (CO2, SO2, N2).We conducted initial experiments using biotite, calcite, and montmorillonite in order to test our methodology with minerals that may be relevant to recording the history of water on Venus. Methods: Experiments were conducted in Thermo Fisher Scientific Lindberg/Blue M Mini-Mite horizontal tube furnaces at Wesleyan University. Experiments used natural mineral chips and powders, and were conducted at 1 atmosphere and 460 °C under pre-mixed gases provided by Air Gas(Table 1). The furnaces are set up in a flow through configuration so that solid samples are exposed to a fixed gas composition, and quartz glass process tubes were used in all experiments (1/4” diameter for experiment V4, ½” diameter for all others). These conditions were maintained for the du-rations listed in Table 1, at which point the furnace was turned off with gas flowing until the sample was cool enough to extract under N2and be placed in a desiccator for storage. Run products were carbon coated and examined using a Hitachi SU5000 Field Emission Gun Scanning Electron Microscope (SEM) equipped with an EDAX Octane Pro EDS detector located at Wesley-an University. Visible-Near Infrared Spectroscopy (VNIR) analysis was performed on powdered samples under a nitrogen atmosphere using an ASD Fieldspec Proover the 350-2500 nm range. Powdered mineral samples were milled to a particle size of < 45μm and were spiked with an internal standard (Al2O3, corundum) to obtain quantitative mineralogy. Samples were analyzed using a Panalytical X’Pert pro X-ray Diffractometer (XRD), with an X’Celerator high speed detector and Co Kα radiation, with data collected at a step size of 0.02 ̊/minute step counting rate from 2 to 80 degrees 2θ at 45 mA/40kV in the X-ray Diffraction Laboratory located at NASA Johnson Space Center. Materials Data Inc (MDI) software suite, JadeTMv9 was used for Rietveld refinement to determine phase abundances and mineral identification by comparing XRD patterns to International Center for Diffraction Data (ICDD) database patterns. Table 1: Experimental matrix. Experiment Name Duration (Days)Gas Com-position (trace gas)MineralsV487SO2/N2(1.4%)Montmorillonite, biotiteV519SO2/N2(1.4%)CalciteV619CO2/SO2/N2(1.4% SO2, 2.1% N2)Montmorillonite, biotiteV828SO2/N2(1.4%)Biotite, calcite Results: Calcite. In both experiments, calcite was exposed to the SO2/N2gas mixture, and in both experimental run products, XRD analysis detected anhydrite, which is consistent with EDS measurements conducted in the SEM. The XRD analyses show greater amounts of anhydrite present after 28 days than 19, suggesting the calcite reaction progressed further given longer duration. Grain surface morphology as seen in the SEM also shows secondary mineral growth (Fig. 1). VNIR spectra show no change, as expected since anhydrite lacks spectral features in this wavelength range. Montmorillonite. Montmorillonite was exposed to two different gas mixtures, the SO2/N2mix and CO2/SO2/N2mix over different durations (87 and 19 days, respectively). VNIR analyses of both run products show a reduction in the 1441and1910 nm water features as well as a shift of the 1411 and 2011 nm features to shorter wavelengths that may indicate re-structuring in the crystal lattice and the production of amorphous phases [4]. XRD results are consistent with this, showing a shift of the 001 peak from 15Åto 10Åin both run products. The amount of X-ray amorphous material in the montmorillonite run products was greater than that present in the unreacted clay, being the greatest in the 87 day V4 experiment. No other secondary phases were detected in the run products, however sulfur was present in EDS analyses of powder samples.

A R Santos↗

A New Optical Aerosol Spectrometer

An optical particle spectrometer capable of measuring aerosol particle size distributions from 0.02 to 100 micrometers has been developed. This instrument combines several optical methods in one, in-situ configuration; it can provide continuous data collection to encompass the wide dynamic size ranges and concentrations found in studies of modeled planetary atmospheres as well as terrestrial air quality research. Currently, the system is incorporated into an eight liter capacity spherical pressure vessel that is appropriate both for flowthrough and for in-situ particle generation. The optical sizing methods include polarization ratio, The scattering, and forward scattering detectors, with illumination from a fiber-coupled, Argon-ion laser. As particle sizes increase above 0.1 micrometer, a customized electronics and software system automatically shifts from polarization to diffraction-based measurements as the angular scattering detectors attain acceptable signal-to-noise ratios. The number concentration detection limits are estimated to be in the part-per-trillion (ppT by volume) range, or roughly 1000 submicron particles per cubic centimeter. Results from static experiments using HFC134A (approved light scattering gas standard), flow-through experiments using sodium chloride (NaCl) and carbon particles, and dynamic 'Tholin' (photochemical produced particles from ultraviolet (UV)-irradiated acetylene and nitrogen) experiments have been obtained. The optical spectrometer data obtained with particles have compared well with particle sizes determined by electron microscopy. The 'Tholin' tests provided real-time size and concentration data as the particles grew from about 30 nanometers to about 0.8 micrometers, with concentrations ranging from ppT to ppB, by volume. Tests are still underway, to better define sizing accuracy and concentration limits, these results will be reported.

Fonda, Mark↗

OSO-8 soft X-ray wheel experiment: Data analysis

The soft X-ray experiment hardware and its operation are described. The device included six X-ray proportional counters, two of which, numbers 1 and 4, were pressurized with on-board methane gas supplies. Number 4 developed an excessive leak rate early in the mission and was turned off on 1975 day number 282 except for brief (typically 2-hour) periods up to day 585 after which it as left off. Counter 1 worked satisfactorily until 1975 day number 1095 (January 1, 1978) at which time the on-board methane supply was depleted. The other four counters were sealed and all except number 3 worked satisfactorily throughout the mission which terminated with permanent satellie shut-down on day 1369. This was the first large area thin-window, gas-flow X-ray detector to be flown in orbit. The background problems were severe and consumed a very large portion of the data analysis effort. These background problems were associated with the Earth's trapped electron belts.

Kraushaar, W. L.↗

Microgravity containerless processing in long drop tubes

Extensive experience in utilizing long drop tubes for studying effects of microgravity on the solidification of alloys was obtained. While some modifications are necessary to improve versatility, the facility proved to be most useful. Both an electron beam furnace and an electromagnetic levitation furnace can be used. The electron beam furnace is used with vacuum environments (0.00001 torr), whereas the levitation furnace is presently used only in inert gas environments (above 100 torr). Experiments are best applied to refractory alloys because of the sensitivity of the detectors now being used to observe solidification. Processing of lower melting point metals and alloys simply cannot be recorded. On the other hand, expected improvements in detector sensitivity will allow experimentation with relatively low melting alloys. In such cases, solidification will occur in flight only if higher inert gas pressure is used (100 to 760 torr) to increase heat loss by convection. Under these conditions microgravity conditions no longer apply. However, as shown by results to date, it is not microgravity as such that is important in drop tube solidification. Instead it is the containerless nature of the process that is significant, leading to large degrees of undercooling before solidification and therefore to unique alloys.

Bayuzick, R. J.↗

Measurements of atmospheric carbonyl sulfide during the NASA Chemical Instrumentation Test and Evaluation Project: Implications for the global COS budget

Atmospheric carbonyl sulfide COS concentrations were measured by three analytical systems during the Chemical Instrumentation Test and Evaluation (CITE 3) project. The three systems all used cryogenic sample preconcentration and gas chromatographic (GC) separation but differed in the method of detection. The FPD system used a flame photometric detector, the MS system used a mass selective detector, and the ECD-S system used a fluorinating catalyst followed by an electron capture detector. With the FPD system, we found a mean COS concentration of 510 ppt over the North Atlantic and 442 ppt over the Tropical Atlantic. With the ECD-S system, we found a mean COS concentration of 489 ppt over the North Atlantic and 419 ppt over the Tropical Atlantic. All three systems registered a latitudinal gradient in atmospheric COS of between 1.6 and 2.0 ppt per degree of latitude, with increasing COS concentrations northward which was similar to the gradient measured by Bingemer et al. (1990). It is difficult to reconcile the measured latitudinal concentration gradient with present theories of the global COS budget since the largest sink of COS is thought to be a flux to land plants, most of which are in the northern hemisphere.

Johnson, James E.↗

Chemical Detection and Identification Techniques for Exobiology Flight Experiments

Exobiology flight experiments require highly sensitive instrumentation for in situ analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical Instrumentation to detect and identify all species present. The minimal resources available onboard for such missions mandate that the instruments provide maximum analytical capabilities with minimal requirements of volume, weight and consumables. Advances in technology may be achieved by increasing the amount of information acquired by a given technique with greater analytical capabilities and miniaturization of proven terrestrial technology. We describe here methods to develop analytical instruments for the detection and identification of a wide range of chemical species using Gas Chromatography. These efforts to expand the analytical capabilities of GC technology are focused on the development of detectors for the GC which provide sample identification independent of the GC retention time data. A novel new approach employs Penning Ionization Electron Spectroscopy (PIES).

Kojiro, Daniel R.↗

Pioneer Venus Orbiter neutral gas mass spectrometer experiment

The Pioneer Venus Orbiter Neutral Mass Spectrometer (ONMS) is designed to measure the vertical and horizontal density variations of the major neutral constituents in the upper atmosphere of Venus. The mass spectrometer sensor includes a retarding potential ion source, hyperbolic quadrupole rod analyzer, and electron multiplier detector. The supporting electronic system consists of hybrid integrated circuits to reduce weight and power. The ONMS instrument was launched aboard the Pioneer Venus Orbiter on May 20, 1978, and turned on in orbit around Venus on December 4, 1978. It has operated flawlessly for over a Venus year (243 earth days) and has returned data of the composition of the major constituents in the Venus atmosphere between the altitudes of 150 and 350 km.

Niemann, H. B.↗

Studies of Light and Charge Produced by Alpha-Particles in High-Pressure Xenon

The results of measurements of scintillation light induced by alpha-particles in high-pressure Xe are presented. The ratio of N(sub ex)/N(sub i) and the intensity and time characteristics of the luminescence signal have been measured for different densities up to 0.74 g/cc. The role and mechanisms of the electron-ion recombination in high-pressure gas have been investigated. The existence of clusters and self-trapped excitons above 0.6 g/cc has been observed and discussed. This work is a part of a development program of high-pressure Xe detectors for low-energy gamma rays.

Bolotnikov, Aleksey↗

Quantitative Species Measurements in Microgravity Combustion Flames using Near-Infrared Diode Lasers

Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for characterizing dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Unfortunately, combustion is highly complicated by fluid mechanical and chemical kinetic processes, requiring the use of numerical modeling to compare with carefully designed experiments. More sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion as well as provide accurate feedback to improve the predictive capabilities of the models. Diode lasers are a natural choice for use under the severe conditions of low gravity experiments. Reliable, simple solid state operation at low power satisfies the operational restrictions imposed by drop towers, aircraft and space-based studies. Modulation wavelength absorption spectroscopy (WMS) provides a means to make highly sensitive and quantitative measurements of local gas concentration and, in certain cases, temperature. With near-infrared diode lasers, detection of virtually all major combustion species with extremely rapid response time is possible in an inexpensive package. Advancements in near-infrared diode laser fabrication technology and concurrent development of optical fibers for these lasers led to their use in drop towers. Since near-infrared absorption line strengths for overtone and combination vibrational transitions are weaker than the mid-infrared fundamental bands, WMS techniques are applied to increase detection sensitivity and allow measurement of the major combustion gases. In the first microgravity species measurement, Silver et al. mounted a fiber-coupled laser at the top of the NASA 2.2-sec drop tower and piped the light through a single-mode fiber to the drop rig. A fiber splitter divided the light into eight channels that directed the laser beam across a methane or propane diffusion jet flame. The light beams were recaptured by a set of gradient index lenses, coupled back into separate fiber optic lines, and transmitted back to detectors and electronics in the instrument package. In these experiments a 6-mm od fiber cable (containing the nine optical fibers) fell with the drop rig. Using separate detection and demodulation channels, spatial and temporal (up to 20 Hz) maps of water vapor and methane concentrations were obtained at differing heights in the flames. While this apparatus was useful from a demonstration standpoint, several drawbacks needed attention before useful scientific measurements could be obtained. First, eight lines of sight are somewhat insufficient for detailing the spatial profiles of the gas. Second, multiple detection channels operating in parallel are both expensive and present a challenge for accurate calibration. As a result, a newer scanning system was developed in our first contract under this program. The primary characteristic of this system is that it contains a single detection channel and achieves "continuous" spatial resolution by scanning the laser beam across the flame region, then directing this beam onto a single detector. Thus spatial measurements are converted to a temporal series of data. The true spatial resolution is limited only by the beam diameter and width of the sweep. In these experiments the beam is focused to about 1-mm diameter and scans across a region up to 4-cm wide.

Silver, Joel A.↗

The HEAO A-2 experiment on the spatial and spectral structure of the X-ray sky /0.2-60 keV/

The HEAO A-2 experiment is described which is designed to observe the spectral and spatial structure of cosmic X-radiation over the entire sky with the minimum sensitivity and cross checks required to achieve a number of objectives. Developments in X-ray astronomy are discussed which are relevant to the experiment, including setting a lower limit on the number of discrete sources contributing to the background flux, determining the spatial dependence of the flux, observations of the spectral components of discrete sources, and the study of X-ray absorption by interstellar gas and the atmospheres of binary stars associated with pulsating X-ray sources. It is shown that systematics-free measurements will be made by making simultaneous observations of single sources with several detectors, by using two-layer detectors to eliminate the effects of electron contamination, and by incorporating magnets into low-energy detectors to minimize electron contamination.

Boldt, E.↗

No Moving Parts

Under a NASA SBIR (Small Business Innovative Research), Research International developed the solid state micromachined pump used for cooling electronics in space, circulation of heat transfer fluids on spacecraft, and monitoring fire and gas hazards aboard naval warships. Incorporating Lewis Research Center's pumping technology, commercial applications for this product include both detection of toxins and pollutants in coal mines, and early warning smoke detectors for industrial applications.

Source record↗

Effects of Hydrogen on Tantalum Nitride Resistors

This document is a presentation about the investigation of drift reported in static frequency output from the analog circuit of a Multichannel Microwave Integrated circuit hybrid microelectronic filter module for space flight application. Electron Dispersion X-Ray Detector )EDAX) Analysis of the 35k ohm thin film Tantalum Nitride Chip resistors identified Palladium in the film. A catalytic reaction of Palladium and hydrogen produces mono atomic hydrogen. When the filter module cavities were filled with a 4 % hydrogen 96 % Nitrogen gas mixture at 25C and monitored the electrical performance for 24 hours. Some channels drifted in a similar pattern as the channel being investigated. Palladium was found on the resistors. The corrective actions taken are reviewed, which resulted in a stable circuit.

Weiler, James↗

Differential Mobility Spectrometry: Preliminary Findings on Determination of Fundamental Constants

The electron capture detector (ECD) has been used for 40+ years (1) to derive fundamental constants such as a compound's electron affinity. Given this historical perspective, it is not surprising that differential mobility spectrometry (DMS) might be used in a like manner. This paper will present data from a gas chromatography (GC)-DMS instrument that illustrates the potential capability of this device to derive fundamental constants for electron-capturing compounds. Potential energy curves will be used to provide possible explanation of the data.

Limero, Thomas↗

A quality monitor and monitoring technique employing optically stimulated electron emission

A light source directs ultraviolet light onto a test surface and a detector detects a current of photoelectrons generated by the light. The detector includes a collector which is positively biased with respect to the test surface. Quality is indicated based on the photoelectron current. The collector is then negatively biased to replace charges removed by the measurement of a nonconducting substrate to permit subsequent measurements. Also, the intensity of the ultraviolet light at a particular wavelength is monitored and the voltage of the light source varied to maintain the light a constant desired intensity. The light source is also cooled via a gas circulation system. If the test surface is an insulator, the surface is bombarded with ultraviolet light in the presence of an electron field to remove the majority of negative charges from the surface. The test surface is then exposed to an ion field until it possesses no net charge. The technique described above is then performed to assess quality.