Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Large-Area Time-Of-Flight (TOF) Upgrade for the STAR Detector

The STAR experiment at RHIC concentrates on the tracking of charged hadrons via ionization in gas- and silicon-based detectors, and the detection of electrons and photons via calorimetry, in a wide and azimuthally complete acceptance that's unique at RHIC. STAR's ability to directly identify the tracked charged hadrons is however limited to low momenta. Approximately half of the charged particles in the event at higher momenta cannot be directly identified, which hampers the physics reach of STAR in a number of key areas. To address this blind spot, STAR is presently constructing a large-area ({approx}50 m{sup 2}) Time-Of-Flight (TOF) system. This system is based on Multi-gap Resistive Plate Chambers (MRPCs). Prototype TOF systems based on this technology were operated in STAR during RHIC Runs 3 through 6, and the first 5 final-system trays were operated in the recent RHIC Run 8. A new 'start detector' for this system has also been constructed and operated in STAR. The performance of these detectors in STAR, and an update on the status of the construction of the full system, is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The resonant tunability, enhancement, and damping of plasma waves in the two-dimensional electron gas plasmonic crystals at terahertz frequencies

The ability to manipulate plasma waves in the two-dimensional-(2D)-electron-gas based plasmonic crystals is investigated in this work. It is demonstrated that the plasmon resonance of 2D plasmonic crystal can be tuned easily at terahertz frequency due to the wavevector quantization induced by the size effect. After calculating self-consistently by taking into account several potential mechanisms for the resonant damping of plasma waves, it can be concluded that the plasmon-plasmon scattering plays the dominant role. Based on the calculations, we can predict the scattering or inter-excitation among the oblique plasmons in the 2D crystal. The results can be extended to study 2D-electron-gas plasmonic waveguides, terahertz modulators, and detectors with electrostatic gating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A measurement of the absolute flux of cosmic-ray electrons

A balloon-borne superconducting magnet spectrometer was used to measure the absolute flux of cosmic-ray electrons. The instrument consisted of a gas Cerenkov detector, a momentum spectrometer, and a lead-scintillator shower counter. In order to determine electron flux in the interstellar medium, observed fluxes for energy loss in the atmosphere and the payload were corrected, taking into account solar modulation effects and bremsstrahlung energy losses. Fluxes were measured at an average atmospheric depth of 5.8 g/sq cm, and the solar modulation was 300 MeV. A cosmic-ray electron flux of 367 E to the exp(3.15 + or -0.2) per sq m/sr s GeV was obtained in the energy range 4.5-63.5 GeV. The uncertainty of the absolute (electron-positron) flux was 10 percent. A summary of the electron data is given in a table.

Golden, R. L.↗

Neutron Structure Function from BoNuS

The BoNuS experiment at Jefferson Lab's Hall B measured the structure of the quasi-free neutron via electron scattering off a deuteron target and detection of the slowly recoiling spectator protonat very backward angles. The very low momentum backward recoiling protons were detected by a novel radial time projection chamber featuring gas electron multipliers, augmenting the CLAS detector. Data were taken successfully in the Fall of 2005.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel infrared detector based on a tunneling displacement transducer

The paper describes the design, fabrication, and characteristics of a novel infrared detector based on the principle of Golay's (1947) pneumatic infrared detector, which uses the expansion of a gas to detect infrared radiation. The present detector is constructed entirely from micromachined silicon and uses an electron tunneling displacement transducer for the detection of gas expansion. The sensitivity of the new detector is competitive with the best commercial pyroelectric sensors and can be readily improved by an order of magnitude through the use of an optimized transducer.

Kenny, T. W.↗

Performance of the Three-Dimensional Track Imager (3-DTI) for Gamma-Ray Telescopes

We have been developing a gas time projection chamber for the imaging of gamma-rays between 0.3 - 50 MeV, the Three-Dimensional Track Imager (3DTI). The detector is being designed for use on satellite experiments for the imaging of astrophysical gamma-ray sources. Electrons produced by pair production or Compton scattering ionize the gas and these ionization electrons are detected by the cross-strip micro-well detector at the bottom of the chamber. Discrete component of front end electronics and time digitization electronics have been developed. We will present results of prototype microwell detector and laboratory set-up in various gas mixtures.

Son, Seunghee↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

A gating grid driver for time projection chambers

A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating grid is open, all wires have the same voltage allowing drift electrons, produced by the ionization of the detector gas molecules, to pass through to the anode wires. When the grid is closed, the wires have alternating higher and lower voltages causing the drift electrons to terminate at the more positive wires. Rapid opening of the gating grid with low pickup noise is achieved by quickly shorting the positive and negative wires to attain the average bias potential with N-type and P-type MOSFET switches. The circuit analysis and simulation software SPICE shows that the driver restores the gating grid voltage to 90% of the opening voltage in less than 0.20 µs, for small values of the termination resistors. When tested in the experimental environment of a time projection chamber larger termination resistors were chosen so that the driver opens the gating grid in 0.35 µs. In each case, opening time is basically characterized by the RC constant given by the resistance of the switches and terminating resistors and the capacitance of the gating grid and its transmission line. By adding a second pair of N-type and P-type MOSFET switches, the gating grid is closed by restoring 99% of the original charges to the wires within 3 µs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of nitrate-enhanced leachate recirculation on gaseous releases from a landfill bioreactor cell

This study evaluates the impact of nitrate injection on a full scale landfill bioreactor through the monitoring of gaseous releases and particularly N{sub 2}O emissions. During several weeks, we monitored gas concentrations in the landfill gas collection system as well as surface gas releases with a series of seven static chambers. These devices were directly connected to a gas chromatograph coupled to a flame ionisation detector and an electron capture detector (GC-FID/ECD) placed directly on the field. Measurements were performed before, during and after recirculation of raw leachate and nitrate-enhanced leachate. Raw leachate recirculation did not have a significant effect on the biogas concentrations (CO{sub 2}, CH{sub 4} and N{sub 2}O) in the gas extraction network. However, nitrate-enhanced leachate recirculation induced a marked increase of the N{sub 2}O concentrations in the gas collected from the recirculation trench (100-fold increase from 0.2 ppm to 23 ppm). In the common gas collection system however, this N{sub 2}O increase was no more detectable because of dilution by gas coming from other cells or ambient air intrusion. Surface releases through the temporary cover were characterized by a large spatial and temporal variability. One automated chamber gave limited standard errors over each experimental period for N{sub 2}O releases: 8.1 {+-} 0.16 mg m{sup -2} d{sup -1} (n = 384), 4.2 {+-} 0.14 mg m{sup -2} d{sup -1} (n = 132) and 1.9 {+-} 0.10 mg m{sup -2} d{sup -1} (n = 49), during, after raw leachate and nitrate-enhanced leachate recirculation, respectively. No clear correlation between N{sub 2}O gaseous surface releases and recirculation events were evidenced. Estimated N{sub 2}O fluxes remained in the lower range of what is reported in the literature for landfill covers, even after nitrate injection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn s magnetosphere, and a steady flux of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager1 . The ubiquitous, surface- hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 Km altitude (approximately 1hPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 141Dalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn's magnetosphere, and a steady flow of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager 1. The ubiquitous, surface-hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 km altitude (approximately lhPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 14lDalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

Associations between pesticide use and respiratory symptoms: A cross-sectional study in Southern Ghana

Background: Indiscriminate use of pesticides is a common practice amongst farmers in Low and Middle Income Countries (LMIC) across the globe. However, there is little evidence defining whether pesticide use is associated with respiratory symptoms. Objectives: This cross-sectional study was conducted with 300 vegetable farmers in southern Ghana (Akumadan). Data on pesticide use was collected with an interviewed-administered questionnaire. The concentration of seven organochlorine pesticides and 3 pyrethroid pesticides was assayed in urine collected from a sub-population of 100 vegetable farmers by a gas chromatograph equipped with an electron capture detector (GC-ECD). Results: A statistically significant exposure-response relationship of years per day spent mixing/applying fumigant with wheezing [30–60 days/year: prevalence ratio (PR)=1.80 (95% CI 1.30, 2.50); >60days/year: 3.25 (1.70–6.33), p for trend=0.003] and hours per day spent mixing/applying fumigant with wheezing [1–2 h/day: 1.20 (1.02–1.41), 3–5 h/day: 1.45 (1.05–1.99), >5 h/day: 1.74 (1.07–2.81), p for trend=0.0225]; days per year spent mixing/applying fungicide with wheezing [30–60 days/year: 2.04 (1.31–3.17); >60days/year: 4.16 (1.72–10.08), p for trend=0.0017] and h per day spent mixing/applying fungicide with phlegm production [1–2 h/day: 1.25 (1.05–1.47), 3–5 h/day: 1.55 (1.11–2.17), >5 h/day: 1.93 (1.17–3.19), p for trend=0.0028] and with wheezing [1–2 h/day: 1.10 (1.00–1.50), 3–5 h/day: 1.20 (1.11–1.72), >5 h/day: 1.32 (1.09–2.53), p for trend=0.0088]; h per day spent mixing/applying insecticide with phlegm production [1–2 h/day: 1.23 (1.09–1.62), 3–5 h/day: 1.51 (1.20–2.58), >5 h/day: 1.85 (1.31–4.15), p for trend=0.0387] and wheezing [1–2 h/day: 1.22 (1.02–1.46), 3–5 h/day: 1.49 (1.04–2.12), >5 h/day: 1.81 (1.07–3.08), p for trend=0.0185] were observed. Statistically significant exposure-response association was also observed for a combination of activities that exposes farmers to pesticide with all 3 respiratory symptoms. Furthermore, significant exposure-response associations for 3 organochlorine insecticides: beta-HCH, heptachlor and endosulfan sulfate were noted. Conclusions: In conclusion, vegetable farmers in Ghana may be at increased risk for respiratory symptoms as a result of exposure to pesticides. - Highlights: • Indiscriminate use of pesticides is common amongst farmers in Low and Middle Income Countries. • We examined associations between pesticide use and respiratory symptoms. • The concentration of organochlorine and pyrethroid pesticides was assayed in urine. • Significant exposure-response associations for beta-HCH, heptachlor and endosulfan sulfate were noted.

54 ENVIRONMENTAL SCIENCES↗

LArPix: demonstration of low-power 3D pixelated charge readout for liquid argon time projection chambers

In this work, we report the demonstration of a low-power pixelated readout system designed for three-dimensional ionization charge detection and digital readout of liquid argon time projection chambers (LArTPCs) . Unambiguous 3D charge readout was achieved using a custom-designed system-on-a-chip ASIC (LArPix) to uniquely instrument each pad in a pixelated array of charge-collection pads. The LArPix ASIC, manufactured in 180 nm bulk CMOS, provides 32 channels of charge-sensitive amplification with self-triggered digitization and multiplexed readout at temperatures from 80 K to 300 K . Using an 832-channel LArPix-based readout system with 3 mm spacing between pads, we demonstrated low-noise (0<50 e - RMS equivalent noise charge) and very low-power (<100 μW/channel) ionization signal detection and readout . The readout was used to successfully measure the three-dimensional ionization distributions of cosmic rays passing through a LArTPC, free from the ambiguities of existing projective techniques. The system design relies on standard printed circuit board manufacturing techniques, enabling scalable and low-cost production of large-area readout systems using common commercial facilities. This demonstration overcomes a critical technical obstacle for operation of LArTPCs in high-occupancy environments, such as the near detector site of the Deep Underground Neutrino Experiment (DUNE) .

47 OTHER INSTRUMENTATION↗

Enhancing Neutrino Event Reconstruction with Pixel-Based 3D Readout for Liquid Argon Time Projection Chambers

In this paper we explore the potential improvements in neutrino event reconstruction that a 3D pixelated readout could offer over a 2D projective wire readout for liquid argon time projection chambers. We simulate and study events in two generic, idealized detector configurations for these two designs, classifying events in each sample with deep convolutional neural networks to compare the best 2D results to the best 3D results. In almost all cases we find that the 3D readout provides better reconstruction efficiency and purity than the 2D projective wire readout, with the advantages of 3D being particularly evident in more complex topologies, such as electron neutrino charged current events. We conclude that the use of a 3D pixelated detector could significantly enhance the reach and impact of future liquid argon TPC experiments physics program, such as DUNE.

Adams, C↗