Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Head on Comparison of Self- and Nano-Assemblies of Gamma Peptide Nucleic Acid Amphiphiles

Peptide nucleic acids (PNAs) are nucleic acid analogs with hybridization properties and enzymatic stability superior to that of DNA. In addition to gene targeting applications, PNAs have garnered significant attention as bio-polymers due to the Watson–Crick-based molecular recognition and flexibility of synthesis. Here, in this work, PNA amphiphiles are engineered using chemically modified gamma PNA (8 mer in length) containing hydrophilic diethylene glycol units at the gamma position and covalently conjugated lauric acid (C12) as a hydrophobic moiety. Gamma PNA ($\gamma$PNA) amphiphiles self-assemble into spherical vesicles. Further, nano-assemblies (NA) are formulated using the amphiphilic $\gamma$PNA as a polymer via ethanol injection-based protocols. Comprehensive head-on comparison of the physicochemical and cellular uptake properties of PNA derived self- and NA is performed. Small-angle neutron and X-ray scattering analysis reveal ellipsoidal morphology of $\gamma$PNA NA that results in superior cellular delivery compate to the spherical self-assembly. Next, the functional activities of $\gamma$PNA self-and NA in lymphoma cells via multiple endpoints, including gene expression, cell viability, and apoptosis-based assays are compared. Overall, it is established that $\gamma$PNA amphiphile is a functionally active bio-polymer to formulate NA for a wide range of biomedical applications.

59 BASIC BIOLOGICAL SCIENCES↗

Gamma-ray spectra analyses of molten salts in spent nuclear fuels pyroprocessing facilities for mass measurement

To evaluate radioactive tracer dilution and gamma spectroscopy as a safeguards technique for monitoring the mass of liquid salt in molten salt systems, the gamma spectroscopy data of salt samples from the pyroprocessing facilities in Idaho National Laboratory were acquired and analyzed. The primary focus is the uncertainty analysis of the gamma radioactivity of 154 Eu isotope in the molten salts. The facilities include an electrorefiner for pyroprocessing spent oxide fuels (SOF-ER) and Mark-IV ER for processing the metallic fuels from Experimental Breeder Reactor-II (EBR-II). The relative gamma radioactivity uncertainty was consistently at 3% for 137 Cs for both Mark-IV ER and SOF-ER salts. However, for 154 Eu, it was 8% for SOF-ER salt and 7% for Mark-IV ER salt. Here, the main reason for the higher uncertainty for 154 Eu is believed to be the lower counting statistics in gamma spectroscopy. To improve the gamma radioactivity uncertainty of isotope 154 Eu, a longer data acquisition time (12 h instead of 4 h) and a higher count rate gamma detector for gamma spectroscopy were tested and it was found that the uncertainty for 154 Eu was significantly improved from 7% or 8–3%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observation of the Gamma-Ray Binary HESS J0632+057 with the H.E.S.S., MAGIC, and VERITAS Telescopes

The results of gamma-ray observations of the binary system HESS J0632 + 057 collected during 450 hr over 15 yr, between 2004 and 2019, are presented. Data taken with the atmospheric Cherenkov telescopes H.E.S.S., MAGIC, and VERITAS at energies above 350 GeV were used together with observations at X-ray energies obtained with Swift-XRT, Chandra, XMM-Newton, NuSTAR, and Suzaku. Some of these observations were accompanied by measurements of the Hα emission line. A significant detection of the modulation of the very high-energy gamma-ray fluxes with a period of 316.7 ± 4.4 days is reported, consistent with the period of 317.3 ± 0.7 days obtained with a refined analysis of X-ray data. The analysis of data from four orbital cycles with dense observational coverage reveals short-timescale variability, with flux-decay timescales of less than 20 days at very high energies. Flux variations observed over a timescale of several years indicate orbit-to-orbit variability. The analysis confirms the previously reported correlation of X-ray and gamma-ray emission from the system at very high significance but cannot find any correlation of optical H$α$ parameters with fluxes at X-ray or gamma-ray energies in simultaneous observations. The key finding is that the emission of HESS J0632 + 057 in the X-ray and gamma-ray energy bands is highly variable on different timescales. The ratio of gamma-ray to X-ray flux shows the equality or even dominance of the gamma-ray energy range. This wealth of new data is interpreted taking into account the insufficient knowledge of the ephemeris of the system and discussed in the context of results reported on other gamma-ray binary systems.

79 ASTRONOMY AND ASTROPHYSICS↗

The Third Fermi Large Area Telescope Catalog of Gamma-Ray Pulsars

We present 294 pulsars found in GeV data from the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope. Another 33 millisecond pulsars (MSPs) discovered in deep radio searches of LAT sources will likely reveal pulsations once phase-connected rotation ephemerides are achieved. A further dozen optical and/or X-ray binary systems colocated with LAT sources also likely harbor gamma-ray MSPs. This catalog thus reports roughly 340 gamma-ray pulsars and candidates, 10% of all known pulsars, compared to ≤11 known before Fermi. Half of the gamma-ray pulsars are young. Of these, the half that are undetected in radio have a broader Galactic latitude distribution than the young radio-loud pulsars. The others are MSPs, with six undetected in radio. Overall, ≥236 are bright enough above 50 MeV to fit the pulse profile, the energy spectrum, or both. For the common two-peaked profiles, the gamma-ray peak closest to the magnetic pole crossing generally has a softer spectrum. The spectral energy distributions tend to narrow as the spindown power $\dot{E}$ decreases to its observed minimum near 10 33 erg s -1 , approaching the shape for synchrotron radiation from monoenergetic electrons. We calculate gamma-ray luminosities when distances are available. Our all-sky gamma-ray sensitivity map is useful for population syntheses. The electronic catalog version provides gamma-ray pulsar ephemerides, properties, and fit results to guide and be compared with modeling results.

79 ASTRONOMY AND ASTROPHYSICS↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

Mapping the cosmic gamma-ray horizon: the 1CGH catalogue of Fermi -LAT detections above 10 GeV

ABSTRACT We present the First Cosmic Gamma-ray Horizon (1CGH) catalogue, featuring $\gamma$-ray detections above 10 GeV based on 16 yr of observations with the Fermi Large Area Telescope (Fermi-LAT) satellite. After carefully selecting a sample of blazars and blazar candidates from catalogues in the literature, we performed a binned likelihood analysis and identified 2791 $\gamma$-ray emitters above 10 GeV, at >3$\sigma$ level, including 62 that are new $\gamma$-ray detections. For each source, we estimated the mean energy of the highest energy bin and analysed them in the context of the cosmic gamma-ray horizon. By adopting a reference model for the extragalactic background light (EBL), we identified a subsample of 525 sources where moderate to severe $\gamma$-ray absorption could be detected across the redshift range of 0–3. This work provides the most up-to-date compilation of detections above 10 GeV, along with their redshift information. We condense extensive results from the literature, including reports on observational campaigns dedicated to blazars and $\gamma$-ray sources, thereby delivering an unprecedented review of the redshift information for sources detected above 10 GeV. Additionally, we highlight key 1CGH sources where redshift information remains incomplete, offering guidance for future optical observation campaigns. The 1CGH catalogue aims to track the most significant sources for studying the $\gamma$-ray transparency of the Universe. Furthermore, it provides a targeted subsample where the EBL optical depth, $\tau _{(E,z)}$, can be robustly measured using Fermi-LAT data.

Arsioli, Bruno (ORCID:0000000181666602)↗

Gamma Dose Measurements in ZPPR-15

Gamma doses were measured in the Zero Power Plutonium Reactor (ZPPR) to provide data for validation of calculations of gamma heating in important reactor components. Stainless steel-encapsulated LiF thermoluminescent dosimeters (TLDs) were irradiated in two configurations in ZPPR-15B and one configuration in ZPPR-15D to provide gamma heating data for the Integral Fast Reactor design in the mid-1980s. The ZPPR-15 experimental records were used to develop detailed as-built Monte Carlo models for the gamma dose measurements in ZPPR-15B and ZPPR-15D. These Monte Carlo models can be converted to deterministic models for calculations with deterministic codes. The reported uncertainty in the published gamma dose measurements is just the statistical uncertainty in the TLD readout. In addition to this statistical uncertainty in the TLD readout, several corrections and other factors contribute to the total uncertainty for the gamma dose measurements. The total uncertainty for the gamma dose measurements can be significantly larger than the published statistical uncertainty for the TLD readout. All known contributions to the total uncertainty were analyzed, and a total uncertainty was derived for the ZPPR-15 gamma dose measurements.

36 MATERIALS SCIENCE↗

Characterizing the Gamma-Ray Emission Properties of the Globular Cluster M5 with the Fermi-LAT

Abstract We analyzed the globular cluster M5 (NGC 5904) using 15 yr of gamma-ray data from the Fermi Large Area Telescope (LAT). Using rotation ephemerides generated from Arecibo and FAST radio telescope observations, we searched for gamma-ray pulsations from the seven millisecond pulsars (MSPs) identified in M5. We detected no significant pulsations from any of the individual pulsars. In addition, we searched for possible variations of the gamma-ray emission as a function of orbital phase for all six MSPs in binary systems, but we did not detect any significant modulations. The gamma-ray emission from the direction of M5 is well described by an exponentially cutoff power-law spectral model, although other models cannot be excluded. The phase-averaged emission is consistent with being steady on a timescale of a few months. We estimate the number of MSPs in M5 to be between 1 and 10, using the gamma-ray conversion efficiencies for well-characterized gamma-ray MSPs in the Third Fermi-LAT Catalog of Gamma-ray Pulsars, suggesting that the sample of known MSPs in M5 is (nearly) complete, even if it is not currently possible to rule out a diffuse component of the observed gamma rays from the cluster.

Astronomy & Astrophysics↗

Angular Correlations of Gamma Rays from Fission Product Solution

Fission products from photon-induced fission are routinely used at Idaho National Laboratory as part of nuclear forensics activities. Typically, the focus is on fission products with relatively large fission yields (Ba-140, Mo-99, etc.). The nuclear data associated with the well-known isotopes have small uncertainties, and many have well-known angular correlations between emitted gamma-rays, if applicable. However, for isotopes with smaller fission yields or less intense gamma-ray emission intensities, the nuclear decay schemes and gamma-ray emission intensities may be less well-known. The Germanium Rotational Measurements for Angular Correlation (GeRMAC) system was designed to use two high-purity germanium (HPGe) detectors in a coincidence counting set-up but allows one of the HPGe detectors to rotate at a constant distance from a radioactive source, changing the relative angle between the two HPGe detectors. Angular correlations can then be determined from the relative photopeak areas between two gamma-rays emitted as part of the same nuclear decay. By recording the HPGe spectra in list mode, the angular correlations of gamma-rays emitted from complex sources, consisting of multiple isotopes, can be measured simultaneously and the individual isotope emissions can be isolated. Using the GeRMAC system, a multi-isotope fission product source, produced with photon-induced fission of U-238, was measured using a single rotational arc (180 degrees) to obtain the angular correlation between gamma-rays emitted by the large number of fission products contained in the solution with an angular accuracy of 1 degree. In particular, La-140 (38 gamma rays) and Nd-147 (26 gamma rays) are of interest to the nuclear forensics community.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Gamma Rays from Kilonova: A Potential Probe of r-process Nucleosynthesis

The mergers of compact binaries with at least one neutron star component are the potential leading sites of the production and ejection of r-process elements. Discoveries of galactic binary pulsars, short gamma-ray bursts, and gravitational-wave detections have all been constraining the rate of these events, while the gravitational wave plus broadband electromagnetic coverage of binary neutron star merger (GW170817) has also placed constraints on the properties (mass and composition) of the merger ejecta. But uncertainties and ambiguities in modeling the optical and infrared emission make it difficult to definitively measure the distribution of heavy isotopes in these mergers. In contrast, gamma rays emitted in the decay of these neutron-rich ejecta may provide a more direct measurement of the yields. We calculate the gamma production in remnants of neutron star mergers, considering two epochs: a kilonova epoch, lasting about two weeks, and a much later epoch of tens and hundreds of thousands of years after the merger. For the kilonova epoch, when the expanding ejecta is still only partially transparent to gamma radiation, we use 3D radiative transport simulations to produce the spectra. Futhermore, we show that the gamma-ray spectra associated with beta- and alpha-decay provide a fingerprint of the ejecta properties and, for a sufficiently nearby remnant, may be detectable, even for old remnants. We compare our gamma spectra with the potential detection limits of next generation detectors, including the Lunar Occultation Explorer (LOX), the All-sky Medium Energy Gamma-ray Observatory (AMEGO), and the Compton Spectrometer and Imager (COSI). We show that fission models can be discriminated via the presence of short-lived fission fragments in the remnant spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

CubeSats for Gamma-Ray Astronomy [Book Chapter]

After many years of flying in space primarily for educational purposes, CubeSats – tiny satellites with form factors corresponding to arrangements of “1U” units, or cubes, each 10 cm on a side – have come into their own as valuable platforms for technology advancement and scientific investigations. CubeSats offer comparatively rapid, low-cost access to space for payloads that can be built, tested, and operated by relatively small teams, with substantial contributions from students and early career researchers. Continuing advances in compact, low-power detectors, readout electronics, and flight computers have now enabled X-ray and gamma-ray sensing payloads that can fit within the constraints of CubeSat missions, permitting in-orbit demonstrations of new techniques and innovative high-energy astronomy observations. Gamma-ray-sensing CubeSats are certain to make an important contribution in the new era of multi-messenger, time-domain astronomy by detecting and localizing bright transients such as gamma-ray bursts, solar flares, and terrestrial gamma-ray flashes; however, other astrophysical science areas requiring long observations in a low-background environment, including gamma-ray polarimetry, studies of nuclear lines, and measurement of diffuse backgrounds, will likely benefit as well. Here we present the primary benefits of CubeSats for high-energy astronomy, highlight the scientific areas currently or soon to be studied, and review the missions that are currently operating, under development, or proposed. A rich portfolio of CubeSats for gamma-ray astronomy already exists, and the potential for a broad range of creative and scientifically productive missions in the near future is very high.

79 ASTRONOMY AND ASTROPHYSICS↗

Applications of HPGe-detected high energy gamma rays toward quantifying neutron emission rates and 234 U enrichment in UF 6 cylinders

This study presents a 234 U enrichment meter that uses high energy gamma and neutron count rate as measured by a portable, high-purity germanium gamma ray detector. Twenty-one 30B cylinders containing UF 6 of varying origin were analyzed with an HPGe detector for high-energy gamma ray and neutron counts. Excellent correlations (R 2 0.95) between various regions of 3.0 MeV gamma rays, neutron count rate, and uranium enrichment were found. These neutron and high-energy gamma data are used to create calibration-dependent enrichment meters for 234 U. The 234 U enrichment calculated from the neutron count rate and 4 – 6 MeV gamma count rate is more accurate than methods that rely on the 120.9 keV peak which is strongly attenuated inside commercial sized UF 6 cylinders. These neutron and high-energy gamma enrichment calculators can also be used to determine a 235 U enrichment, assuming mass-based enrichment from natural uranium, but the results are not as accurate as the traditional 185.7 keV peak enrichment meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of gamma-ray transmission through rectangular collimator slits for application in nuclear fuel spectrometry

Gamma-ray spectrometry is widely applied in several science fields, and in particular in non-destructive gamma scanning and gamma emission tomography of irradiated nuclear fuel. Usually, a collimator is used in the experimental setup, to selectively interrogate a region of interest in the fuel. For the optimization of instrument design, as well as for planning measurement campaigns, predictive models for the transmitted gamma-ray intensity through the collimator are needed. Commonly, Monte Carlo Radiation Transport tools are used for accurate prediction of gamma-ray transport, however, the long computation time requirements when used in low-efficiency experimental setups present challenges. Here, the full-energy peak intensity transmitted through a rectangular collimator slit was examined. A uniform planar surface source emitting isotropically was considered, and the rate of photons reaching an ideal counter plane on the opposite side of the collimator was evaluated by analytical integration. To find a closed-form primitive function, some idealizations were required, and thereby parametric models were obtained for the optical field of view, dependent on slit dimensions (length, height and width) and source-to-collimator distance. For contributions from outside the optical field of view, where a closed-form expression cannot be found, fast numerical integral methods were instead used. The results were validated using the Monte Carlo code MCNP6 and show an agreement within three percent for the numerical method. For the analytical method, deviations up to tens of percent were obtained, which is deemed to still be sufficient for instrument design and measurement planning, where often the order of magnitude of the count rate is not a priori known. The method is planned for use in iterative optimization routines in the design of Gamma Emission Tomography devices, as well as for the prediction of gamma spectra obtained in the planning of fuel inspections. An application of the proposed method was demonstrated in spectrum prediction for a short cooling-time fuel rod test from the Halden reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Machine learning framework for predicting uranium enrichments from M400 CZT gamma spectra

A machine learning framework was developed for predicting uranium enrichments from M400 CZT gamma spectra. This framework leverages the availability of a large amount of measured M400 gamma spectra and uses a recently updated version of Gamma Detector Response and Analysis Software (GADRAS) for gamma spectrum analysis and generation. It also leverages the existing machine learning modules in Python for gamma spectrum data processing, curation, model training, benchmarking, and optimization of the deep machine learning models. The framework is used to develop a deep learning model to analyze gamma spectra from a set of U 3 O 8 samples with enrichments ranging from 0.31 to 93.17% and UF 6 cylinders with enrichments ranging from 0.2 to 4.95%, and the model performance is tested using a set of measured spectra and the respective declared enrichment values. Results show that the model can correctly classify 99.35% of the U 3 O 8 sample enrichments, and can predict the samples’ enrichments within an average absolute error of 0.099% (in percentage points of enrichment). For the UF 6 cylinders, the average absolute error was approximately 0.03%, with an accuracy of 98% in classifying discrete enrichment values of UF 6 samples. Finally, the results also show that the model has performed significantly better in terms of predicting enrichments in UF 6 cylinders based on measured gamma spectra than the GEM code, with a standard deviation (of the relative errors) of 2.23% (compared with the 11.51% value for the GEM code) based on results from a set of test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Deep Search for Gamma-Ray Emission from the Accreting X-Ray Pulsar 1A 0535+262

Binary systems are a well-established subclass of gamma-ray sources. The high mass X-ray binary pulsar 1A 0535+262 has been considered to be a possible gamma-ray emitter for a long time, although former gamma-ray searches using the Fermi Large Area Telescope (LAT) and VERITAS data resulted in upper limits only. We aim at a deep search for gamma-ray emission and pulsations from 1A 0535+262 using more than 13 yr of Fermi-LAT data. The analysis was performed for both the whole Fermi-LAT data set, as well as for the X-ray outbursts that 1A 0535+262 has experienced since the launch of Fermi. Various X-ray observations have been used to generate the ephemeris for the pulsation search. We also investigate the long-term gamma-ray flux variability and perform orbital phase-resolved analysis for the outbursts. We did not detect any steady or pulsed gamma-ray emission from 1A 0535+262 during the whole Fermi-LAT mission span or its X-ray outbursts. We thus derived the deepest gamma-ray luminosity upper limits to date at the 95% confidence level to be around (2.3–4.7) × 10 32 erg s -1 depending on different spectral indices assumed, which results in a ratio of L γ to L X (2–150 keV) being (1.9–3.9) × 10 -6 .

79 ASTRONOMY AND ASTROPHYSICS↗

Interpolation of computed gamma-ray detector response functions

Gamma-ray spectra measured by traditional detectors contain features that result from a combination of the effects of detector materials/geometry, the incident gamma-ray energy, and the angle of entry. The features, such as the full-energy photopeak, Compton continuum, annihilation peak, and escape peaks, are governed by simple relationships depending on incident energy and have been known for a long time. Monte Carlo computer simulations of gamma rays interacting with a detector will show these features, and with a resolution function applied, the results should look similar to real measurements. The traditional approach to creating a detector response function requires many separate simulations of monoenergetic gamma rays striking the detector. This paper presents a new approach to developing computed detector response functions. The new approach involves a much smaller number of monoenergetic gamma-ray simulations and uses interpolation to quickly generate the responses of gamma rays that were not simulated. During the interpolation process, the underlying physics equations are used to accurately compute the response of a given energy gamma ray from the small set of simulations. Such work enables accelerated generation of synthetic radiation detector data.

Detector response↗

Methodology to Generate the Decay Gamma Source for a Second Target Station Target Wedge

This report details the specifics of applying the Position-Averaged Method methodology for the calculation of the rotating lasagna-style target wedge activation and the resulting decay gamma source terms. The methodology uses MCNP® Code Version 6.2.0 with the RNUCS patch coupled with CINDER2008 from the AARE V1.0 package. The process begins with model preparations that include ensuring impurities are included in the materials in the regions of interest along with segmentation of the geometry in order to capture the decay gamma source gradients. This report also details the physics models and other MCNP®, CINDER2008, and ADVANTG 3.2.0 related options used to calculate the decay gamma source terms. ADVANTG 3.2.0 is used to generate a weight window set to aid in convergence of the neutron fluxes in the initial MCNP® protons-on-target particle transport calculation to calculate the neutron fluxes and spallation products in the regions of interest. The neutron fluxes and spallation products are then used in the CINDER2008 transmutation calculation, and the decay gamma sources are generated by the AARE_GAMMA_SOURCE_SCRIPT as a part of the AARE V1.0 package. These decay gamma sources include the energy distributions as well as the necessary distributions to sample the location of the source using the cell rejection method. The gamma sources that are produced using the methodology may be used for a wide variety of analysis involving the target wedge. This report includes the material specifications, physics options, proton source term description, geometrical configuration, and post-processing details.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗