Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “galvanic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Exhibition of Stochastic Resonance in Vestibular Perception

Astronauts experience sensorimotor changes during spaceflight, particularly during G-transitions. Post flight sensorimotor changes include spatial disorientation, along with postural and gait instability that may degrade operational capabilities of the astronauts and endanger the crew. A sensorimotor countermeasure that mitigates these effects would improve crewmember safety and decrease risk. The goal of this research is to investigate the potential use of stochastic vestibular stimulation (SVS) as a technology to improve sensorimotor function. We hypothesize that low levels of SVS will improve sensorimotor perception through the phenomenon of stochastic resonance (SR), when the response of a nonlinear system to a weak input signal is enhanced by the application of a particular nonzero level of noise. This study aims to advance the development of SVS as a potential countermeasure by 1) demonstrating the exhibition of stochastic resonance in vestibular perception, a vital component of sensorimotor function, 2) investigating the repeatability of SR exhibition, and 3) determining the relative contribution of the semicircular canals (SCC) and otolith (OTO) organs to vestibular perceptual SR. A constant current stimulator was used to deliver bilateral bipolar SVS via electrodes placed on each of the mastoid processes, as previously done. Vestibular perceptual motion recognition thresholds were measured using a 6-degree of freedom MOOG platform and a 150 trial 3-down/1-up staircase procedure. In the first test session, we measured vestibular perceptual thresholds in upright roll-tilt at 0.2 Hz (SCC+OTO) with SVS ranging from 0-700 μA. In a second test session a week later, we re-measured roll-tilt thresholds with 0, optimal (from test session 1), and 1500 μA SVS levels. A subset of these subjects, plus naive subjects, participated in two additional test sessions in which we measured thresholds in supine roll-rotation at 0.2 Hz (SCC) and upright y-translation at 1 Hz (OTO) with SVS up to 700 μA. A sinusoidal galvanic vestibular stimulation (GVS) perceptual threshold was also measured on each test day and used to normalize the SVS levels across subjects. In roll-tilt thresholds with SVS, the characteristic SR curve was qualitatively exhibited in 10 of 12 subjects, and the improvement in motion threshold was significant in 6 subjects, indicating that optimal SVS improved passive body motion perception in a way that is consistent with classical SR theory. A probabilistic comparison to numeric simulations further validated these experimental results. On the second test session, 4 out of the 10 SR exhibitors showed repeated improvement with SVS compared to the no SVS condition. Data collection is ongoing for the last two test sessions in which SCC and OTO only perceptual motion recognition thresholds are being measured with SVS. The final results of these test sessions will give insight into whether vestibular perceptual SR can occur when only one type of vestibular sensor is sensing motion or if it is more evident when sensory integration between the SCC and OTO is occurring during the motion. The overall purpose of this research is to further quantify the effects of SVS on various sensorimotor tasks and to gain a more fundamental understanding of how SVS causes SR in the vestibular system. In the context of human space flight, results from this research will help in understanding how SVS may be practically implemented in the future as a component of a comprehensive countermeasure plan for G-transition adaptation.

Galvan-Garza, R. C.↗

Simple, nondestructive test identifies metals

Rapid, nondestructive test for identifying metals measures the characteristic potential difference produced by galvanic reaction between a reference electrode and the test metal. A drop of water is used as an electrolyte.

Dodds, D. J.↗

Valve seat pores sealed with thermosetting monomer

Hard anodic coating provides a smooth wear resistant value seating surface on a cast aluminum alloy valve body. Vacuum impregnation with a thermosetting monomer, diallyl phthalate, seals the pores on the coating to prevent galvanic corrosion.

Olmore, A. B.↗

Device removes hydrogen gas from enclosed spaces

Hydrogen-oxidant galvanic cell removes small amounts of hydrogen gas continually released from equipment, such as vented silver-zinc batteries, in enclosed compartments where air venting is not feasible. These cells are used in satellite compartments.

Carson, W. N.↗

Bio-grid system Final report

Feasibility of multiple bio-electrode arrays to sensor galvanic skin response signals during body movement

BODY MEASUREMENT /BIOL/↗

Tube swaging device uses explosive force

Tool joins a sleeve to a tube by explosive swaging, thus providing a leakproof, lightweight, and strong assembly. No new or different material is used in this method and therefore the thermal and galvanic properties are maintained.

Mc Smith, D. G.↗

Corrosion protection of aluminum alloys in contact with other metals

Study establishes the quality of chemical and galvanized protection afforded by anodized and aldozided coatings applied to test panels of various aluminum alloys. The test panels, placed in firm contact with panels of titanium alloys, were subjected to salt spray tests and visually examined for corrosion effect.

Kuster, C. A.↗

Cadmium plated steel caps seal anodized aluminum fittings

Cadmium prevents fracturing of hard anodic coating under torquing to system specification requirements, prevents galvanic coupling, and eliminates need for crush washers, which, though commonly used in industry, do not correct leakage problem experienced when anodized aluminum fittings and anodized aluminum cap assemblies are joined.

Padden, J.↗

Dynamic control models of the semicircular canals

Vestibular system semicircular canals mathematical model determination of galvanic stimulation and directional preponderance, considering visual, postural and vehicle orientation feedback loops

Young, L. R.↗

Effects of stress upon psychophysiological responses and performance following sleep deprivation

The usefulness of psychological and physiological variables in predicting performance under stress of 48 hours of sleep deprivation was investigated. Performance tests, with subjects of different ego strength personalities, in concept acquisition, reading comprehension, word association, word memory, and anagrams were conducted, and physiological measurements of (1) the phasic and tonic electrodermal, (2) galvanic skin response, (3) thermal skin resistance, (4) heart rate, (5) respiration, and (6) plethysmographic finger pulse volumn were recorded. It was found that the changes in the pattern of performance were the result of testing subjects at times when they would normally be sleeping, and that sleep deprivation longer than 48 hours must be maintained to produce changes in simple or well learned tasks.

Roessler, R.↗

Electromotive force measurements on cells involving beta-alumina solid electrolyte

Open circuit emf measurements have been made to demonstrate that a two-phase, polycrystalline mixture of beta- alumina and alpha-alumina could be used as a solid electrolyte in galvanic cells with reversible electrodes fixing oxygen or aluminum chemical potentials. These measurements indicate that such a two phase solid electrolyte can be used to monitor oxygen chemical potentials as low as that corresponding to Al, Al2O3 coexistence. The activity of Na2O in beta-alumina in coexistence with alpha-alumina was also determined by emf measurements.

Choudhury, N.↗

Ergonomics research methods

Various factors used in ergonomic research are given. They are: (1) anthrometric measurement, (2) polyeffector method of assessing the functional state of man, (3) galvanic skin reaction, (4) pneumography, (5) electromyography, (6) electrooculography, and (7) tachestoscopy. A brief summary is given of each factor and includes instrumentation and results.

Uspenskiy, S. I.↗

Dissimilar metals joint evaluation

Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.

Wakefield, M. E.↗

Titanium fasteners

Titanium fasteners are used in large quantities throughout the aircraft industry. Most of this usage is in aluminum structure; where titanium structure exists, titanium fasteners are logically used as well. Titanium fasteners offer potential weight savings to the designer at a cost of approximately $30 per pound of weight saved. Proper and least cost usage must take into consideration type of fastener per application, galvanic couples and installation characteristics of protective coatings, cosmetic appearance, paint adhesion, installation forces and methods available and fatigue performance required.

Phillips, J. L.↗