Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Condenser Microphone Protective Grid Correction for High Frequency Measurements

Use of a protective grid on small diameter microphones can prolong the lifetime of the unit, but the high frequency effects can complicate data interpretation. Analytical methods have been developed to correct for the grid effect at high frequencies. Specifically, the analysis pertains to quantifying the microphone protective grid response characteristics in the acoustic near field of a rocket plume noise source. A frequency response function computation using two microphones will be explained. Experimental and instrumentation setup details will be provided. The resulting frequency response function for a B&K 4944 condenser microphone protective grid will be presented, along with associated uncertainties

Lee, Erik↗

Low noise buffer amplifiers and buffered phase comparators for precise time and frequency measurement and distribution

Extremely low noise, high performance, wideband buffer amplifiers and buffered phase comparators were developed. These buffer amplifiers are designed to distribute reference frequencies from 30 KHz to 45 MHz from a hydrogen maser without degrading the hydrogen maser's performance. The buffered phase comparators are designed to intercompare the phase of state of the art hydrogen masers without adding any significant measurement system noise. These devices have a 27 femtosecond phase stability floor and are stable to better than one picosecond for long periods of time. Their temperature coefficient is less than one picosecond per degree C, and they have shown virtually no voltage coefficients.

Eichinger, R. A.↗

Combined Amplitude and Frequency Measurements for Non-Contacting Turbomachinery Blade Vibration

A method and apparatus for measuring the vibration of rotating blades, such as turbines, compressors, fans, or pumps, including sensing the return signal from projected energy and/or field changes from a plurality of sensors mounted on the machine housing. One or more of the sensors has a narrow field of measurement and the data is processed to provide the referenced time of arrival of each blade, and therefore the blade tip deflection due to vibration. One or more of the sensors has a wide field of measurement, providing a time history of the approaching and receding blades, and the data is processed to provide frequency content and relative magnitudes of the active mode(s) of blade vibration. By combining the overall tip deflection magnitude with the relative magnitudes of the active modes, the total vibratory stress state of the blade can be determined.

Platt, Michael J.↗

Construction and Calibration of a Difference Frequency Laser Spectrometer and New THZ Frequency Measurements of water and Ammonia

A three laser system based on 852nm DBR lasers has been constructed and used to generate radiation in the 750 GHz to 1600 GHz frequency region. The system works by locking two of the three lasers to modes of an ultra low expansion Fabry-Perot cavity. The third laser is offset locked to one of the cavity locked lasers with conventional microwave techniques. The signal from the offset laser and the other cavity locked laser are injected into a Master Oscillator Power Amplifier (MOPA), amplified and focused on a low temperature grown GaAs photomixer, which radiates the difference frequency. The system has been calibrated with molecular lines to better than one part in 10(exp 7). In this paper we present the application of this system to the v(sub 2) in inversion band of Ammonia and the ground and v(sub 2) states of water. A discussion of the system design, the calibration and the new spectral measurements will be presented.

Pearson, J. C.↗

A multi-frequency measurement of thermal microwave emission from soils: The effects of soil texture and surface roughness

An experiment on remote sensing of soil moisture content was conducted over bare fields with microwave radiometers at the frequencies of 1.4 GHz, 5 GHz, and 10.7 GHz during July - September of 1981. Three bare fields with different surface roughnesses and soil textures were prepared for the experiment. Ground truth acquisition of soil temperatures and moisture contents for 5 layers down to the depths of 15 cm was made concurrently with radiometric measurements. The experimental results show that the effect of surface roughness is to increase the soils' brightness temperature and to reduce the slope of regression between brightness temperature and moisture content. The slopes of regression for soils with different textures are found to be comparable, and the effect of soil texture is reflected in the difference of regression line intercepts at brightness temperature axis. The result is consistent with laboratory measurement of soils' dielectric permittivity. Measurements on wet smooth bare fields give lower brightness temperatures at 5 GHz than at 1.4 GHz.

Wang, J. R.↗

A multi-frequency measurement of thermal microwave emission from soils - The effect of soil texture and surface roughness

An experiment on remote sensing of soil moisture content was conducted over bare fields with microwave radiometers at the frequencies of 1.4 GHz, 5 GHz, and 10.7 GHz during July September of 1981. Three bare fields with different surface roughneses and soil textures were prepared for the experiment. Ground truth acquisition of soil temperatures and moisture contents for 5 layers down to the depth of 15 cm was made concurrently with radiometric measurements. The experimental results show that the effect of surface roughness is to increase the soils' brightness temperature and to reduce the slope of regression between brightness temperature and moisture content. The slopes of regression for soils with different textures are found to be comparable, and the effect of soil texture is reflected in the difference of regression line intercepts at brightness temperature axis. The result is consistent with laboratory measurement of soils' dielectric permittivity. Measurements on wet smooth bare fields give lower brightness temperatures at 5 GHz than at 1.4 GHz. Previously announced in STAR as N82-24550

Wang, J. R.↗

Super-resolved time–frequency measurements of coupled phonon dynamics in a 2D quantum material

Abstract Methods to probe and understand the dynamic response of materials following impulsive excitation are important for many fields, from materials and energy sciences to chemical and neuroscience. To design more efficient nano, energy, and quantum devices, new methods are needed to uncover the dominant excitations and reaction pathways. In this work, we implement a newly-developed superlet transform—a super-resolution time-frequency analytical method—to analyze and extract phonon dynamics in a laser-excited two-dimensional (2D) quantum material. This quasi-2D system, 1 T -TaSe 2 , supports both equilibrium and metastable light-induced charge density wave (CDW) phases mediated by strongly coupled phonons. We compare the effectiveness of the superlet transform to standard time-frequency techniques. We find that the superlet transform is superior in both time and frequency resolution, and use it to observe and validate novel physics. In particular, we show fluence-dependent changes in the coupled dynamics of three phonon modes that are similar in frequency, including the CDW amplitude mode, that clearly demonstrate a change in the dominant charge-phonon couplings. More interestingly, the frequencies of the three phonon modes, including the strongly-coupled CDW amplitude mode, remain time- and fluence-independent, which is unusual compared to previously investigated materials. Our study opens a new avenue for capturing the coherent evolution and couplings of strongly-coupled materials and quantum systems.

36 MATERIALS SCIENCE↗

Combined Optical and Radio-Frequency Measurements of a Lightning Megaflash by the FORTE Satellite

The optical and VHF instrumentation on the Fast On-Orbit Recording of Transient Events (FORTE) satellite is used to document the combined phenomenology evolution of a lightning “megaflash” – mesoscale lightning that propagates laterally over exceptional distances. We identify a FORTE flash whose maximum extent was 82 km and inferred length over multiple distinct branches exceeded 100 km. This flash lasted 1.2 s and produced 250 optical and 591 RF events. We find that the channel development mapped by FORTE’s pixelated lightning imager (LLS) occurred at a typical speed of 2.6x10 5 m s -1 and was accompanied by sustained periods of VHF emission that could individually exceed 100 ms in duration. The impulsive IC events generated by the flash indicate that this development occurred at altitudes between 3 and 8 km. Four +CG strokes were identified in the VHF waveform data that are responsible for two of the three highly-radiant LLS groups (two of the +CGs were not as optically bright as the others). These strokes occurred at different locations throughout the flash footprint with the most distant strokes separated by approximately 50 km. These space-based observations match previous observations of megaflashes as well as ground-based measurements of negative leader development during “spider” lightning, suggesting that FORTE is sensing the same phenomena.

Peterson, Michael Jay↗

Method and apparatus for measuring frequency and phase difference

The present invention is a system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams are directed toward a target and corresponding beams returning therefrom are detected. A digital difference circuit forms a pulse train from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display are correlative to target position relative to beams.

Shores, Paul↗

High Frequency Measurements of the Spectrum of Sgr A(sup *)

We report near-simultaneous interferometric measurements of the spectrum of Sgr A(sup *) over the 5 to 354 GHz range, and single-dish observations which have yielded the first detection of Sgr A(sup *) at 850 GHz. We confirm that Sgr A(sup *)'s spectrum rises more steeply at short mm wavelengths than at cm wavelengths, leading to a near-millimeter/submillimeter excess which dominates its luminosity. Below 900 GHz, Sgr A(sup *)'s observed luminosity is 70 +/- 30 solar luminosity). A new upper limit to Sgr A(sup *)'s 24.3 microns flux, together with a compilation of other extant IR data, imply a FIR spectral turnover, which can result either from an intrinsic synchrotron cutoff, or excess extinction near Sgr A(sup *). If the former applies, Sgr A(sup *)'s total synchrotron luminosity is less than 10(exp 3) solar luminosity, while in the latter case it is less than 3 x 10(exp 4) solar luminosity if spherical symmetry also applies.

Serabyn, E.↗

Method and apparatus for measuring frequency and phase difference

A system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams 152 and 152A are directed toward a target 153 and corresponding beams 154 and 154A returning therefrom are detected. A digital difference circuit 110 forms a pulse train 66 from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display 144 are correlative to target position relative to beams 152 and 152A.

Kobayashi, Herbert S.↗

Method of Detecting System Function by Measuring Frequency Response

Real time battery impedance spectrum is acquired using one time record, Compensated Synchronous Detection (CSD). This parallel method enables battery diagnostics. The excitation current to a test battery is a sum of equal amplitude sin waves of a few frequencies spread over range of interest. The time profile of this signal has duration that is a few periods of the lowest frequency. The voltage response of the battery, average deleted, is the impedance of the battery in the time domain. Since the excitation frequencies are known, synchronous detection processes the time record and each component, both magnitude and phase, is obtained. For compensation, the components, except the one of interest, are reassembled in the time domain. The resulting signal is subtracted from the original signal and the component of interest is synchronously detected. This process is repeated for each component.

Morrison, John L.↗