Effective and Environmentally Compliant Cleaner Solstice® Performance Fluid

On January 1, 2015, the United States Environmental Protection Agency identified exemptions on the continued use of the hydrochlorofluorocarbon (HCFC)-225ca and -225cb. As these solvents are commonly used in cleaning and verification of aerospace propulsion systems using liquid and gaseous oxygen, the NESC supported the Agency initiative to identify and characterize acceptable alternate fluids. Honeywell’s Solstice® Performance Fluid (PF), PF-high purity (HP), and PF-HP spray are an effective nonflammable cleaning solution system, with a favorable toxicity profile and low environmental impact. Solstice PF is suitable for electronics, metal, and precision cleaning. It can be used in vapor degreasing equipment and may be dispensed with a propellant to create an aerosol contact cleaner. Solstice PF has been shown to have negligible ozone depletion and a global warming potential of 1. With these characterized environmental and solvency properties, Solstice PF, PF-HP, or PF-HP spray may be an excellent choice for a variety of cleaning applications.

Effective Compliant Cleaner↗

Chemical Characterization and Thermal Stressing Studies of Perfluorohexane Fluids for Space-Based Applications

Perfluorohexane (PFH), C6F14, is a perfluorocarbon fluid. Several PFH fluids with different isomer concentrations were evaluated for use in an upcoming NASA space experiment. Samples tested included two commercially obtained high-purity n-perfluorohexane (n-PFH) fluids and a technical grade mixture of C6F14 branched and linear isomers (FC-72(TradeMark)). These fluids were evaluated for exact chemical composition, impurity purity and high temperature degradation behavior (pyrolysis). Our investigation involved simulated thermal stressing studies of PFH fluids under conditions likely to occur in the event of an atmospheric breach within the International Space Station (ISS) and subsequent exposure of the vapors to the high temperature and catalyst present in its Trace Contaminant Control Subsystem (TCCS). Exposure to temperatures in the temperature range of 200-450 C in an inert or oxidizing atmosphere, with and without the presence of catalyst was investigated. The most aggressive conditions studied were exposure of PFH vapors to 450 C in air and in the presence of TCCS (palladium) catalyst. Gas chromatography-mass spectrometry (GC-MS) and gas chromatography (GC) analyses were conducted on the perfluorohexane samples before and after pyrolysis. The FC-72 and n-PFH samples showed no significant degradation following pyrolysis even under the most aggressive study conditions. Some trace level impurities associated with the PFH samples such as linear perfluorocarbon monohydrides or monoiodides were destroyed by pyrolysis at the upper limit. Other trace level impurities such as olefinic or cycloolefinic perfluorocarbons were converted into oxidation products by pyrolysis. The purity of PFH following pyrolysis actually increased slightly as a consequence since these trace contaminants were effectively scrubbed from the samples. However, since the initial concentrations of the thermally-impacted impurities were so low, the net effect was trivial. A potential byproduct of exposure of perfluorohexane fluids to high temperatures is the production of perfluoroisobutene (PFiB), which is extremely toxic. An ultra-high sensitivity PFiB-specific analysis based on GC-MS with negative ion chemical ionization (NICI) detection was used to evaluate the samples following thermal stressing. The perfluorohexanes examined here under conditions reflective of the ISS TCCS environment showed no signs of PFiB production with an analytical detection limit of 10 part per billion (ppb v/v).

Arnold, William A.↗

Acoustic radiation damping of flat rectangular plates subjected to subsonic flows

The acoustic radiation damping for various isotropic and laminated composite plates and semi-infinite strips subjected to a uniform, subsonic and steady flow has been predicted. The predictions are based on the linear vibration of a flat plate. The fluid loading is characterized as the perturbation pressure derived from the linearized Bernoulli and continuity equations. Parameters varied in the analysis include Mach number, mode number and plate size, aspect ratio and mass. The predictions are compared with existing theoretical results and experimental data. The analytical results show that the fluid loading can significantly affect realistic plate responses. Generally, graphite/epoxy and carbon/carbon plates have higher acoustic radiation damping values than similar aluminum plates, except near plate divergence conditions resulting from aeroelastic instability. Universal curves are presented where the acoustic radiation damping normalized by the mass ratio is a linear function of the reduced frequency. A separate curve is required for each Mach number and plate aspect ratio. In addition, acoustic radiation damping values can be greater than or equal to the structural component of the modal critical damping ratio (assumed as 0.01) for the higher subsonic Mach numbers. New experimental data were acquired for comparison with the analytical results.

Lyle, Karen Heitman↗

Characterization of Jugular Venous Blood Flow During Acute Fluid Shifts

INTRODUCTION Exposure to weightlessness induces a headward fluid shift and redistribution of fluids, resulting in increased internal jugular vein (IJV) cross-sectional area and altered IJV blood flow dynamics, including stasis and retrograde flow. These findings may contribute to various risks of spaceflight, including thrombosis or other risks affected by cerebral venous blood flow. To date, our understanding of the cerebral venous outflow dynamics in weightlessness is limited to the left IJV assessed ~45 and ~150 days into spaceflight. Therefore, it is unknown how quickly the alterations in venous blood flow dynamics change as a result of weightlessness. The purpose of this study is to determine 1) if venous stasis is an immediate effect of weightlessness and therefore a risk for short-duration missions and 2) the effect of weightlessness on brachiocephalic venous flow. METHODS In this study, we investigated the effects of acute weightlessness during parabolic flight on the right and left IJV in 12 healthy subjects. Baseline ultrasound images were obtained on the ground (1g) in the seated and supine postures and during 0g parabolic flight. Each data collection session included 2D ultrasonography to quantify IJV cross-sectional area and Doppler ultrasonography to characterize venous blood flow patterns in the bilateral IJVs. RESULTS There was a similar pattern of response in the left and right IJV area across postures and g-levels. IJV area increased from seated to supine by 0.74 mm2 (95% CI: 0.56 to 0.91 mm2, p<.001) and increased further during weightlessness by 0.29 mm2 (95% CI: 0.11 to 0.47 mm2, p=.0015). IJV Doppler images revealed stagnant flow in the left IJV in one subject during 0g exposure that was not present during any imaging on the ground; the right IJV continued to show pulsatile, nominal flow patterns in both 0g and 1g. CONCLUSIONS This study characterized the immediate effect of the weightlessness-induced headward fluid shift on venous parameters in the left and right IJV. The left IJV appears to be more susceptible to flow alterations, including stagnant flow, during both short and long-duration exposure to weightlessness that may contribute to the risk of thrombosis inflight.

K Marshall-Goebel↗

Characterization of Jugular Venous Blood Flow During Acute Fluid Shifts

INTRODUCTION Exposure to weightlessness induces a headward fluid shift and redistribution of fluids, resulting in increased internal jugular vein (IJV) cross-sectional area and altered IJV blood flow dynamics including stasis and retrograde flow. These findings may contribute to various risks of spaceflight, including thrombosis or other risks affected by cerebral venous blood flow. To date, our understanding of the cerebral venous outflow dynamics is limited to the left IJV assessed ~45and ~150days into spaceflight. Therefore, it is unknown how quickly the alterations in venous blood flow dynamics change as a result of weightlessness. The purpose of this study is to determine 1) if venous stasis is an immediate effect of weightlessness, and therefore a risk for short-duration missions, and 2) the effect of weightlessness on brachiocephalic venous flow. METHODS In this study, we will determine the effects of acute weightlessness during parabolic flight on right and left IJV cross-sectional area, as well as blood flow dynamics through the IJV and brachiocephalic veins in 12 healthy subjects. Baseline ultrasound images will be obtained on the ground prior to the parabolic flight in the seated and supine postures to determine normal changes in blood flow with posture-induced fluid shifts in a 1genvironment. Subjects will then undergo parabolic flight withrepeated,~20 second exposure to 0g. Each data collection session will include 2D ultrasonography to quantify IJV cross-sectional area and Doppler ultrasonography to characterize venous blood flow patterns in the IJV and brachiocephalic veins. RESULTS Data collection for this study is planned to take place in October, 2021.CONCLUSIONS This study will characterize the immediate venous response in the left and right IJV and brachiocephalic veins upon entry into weightlessness. The results from this parabolic flight study will be compared with previous data from International Space Station crewmembers collectedafter~45 and ~150 days into spaceflight to provide a more complete understanding of the temporal profile of changes in venous blood flow dynamics during weightlessness and whether these findings develop in veins other than the left IJV. Supported by the NASA Human Research Program.

K Marshall-Bowman↗

Finite element computation of a viscous compressible free shear flow governed by the time dependent Navier-Stokes equations

A finite element algorithm for solution of fluid flow problems characterized by the two-dimensional compressible Navier-Stokes equations was developed. The program is intended for viscous compressible high speed flow; hence, primitive variables are utilized. The physical solution was approximated by trial functions which at a fixed time are piecewise cubic on triangular elements. The Galerkin technique was employed to determine the finite-element model equations. A leapfrog time integration is used for marching asymptotically from initial to steady state, with iterated integrals evaluated by numerical quadratures. The nonsymmetric linear systems of equations governing time transition from step-to-step are solved using a rather economical block iterative triangular decomposition scheme. The concept was applied to the numerical computation of a free shear flow. Numerical results of the finite-element method are in excellent agreement with those obtained from a finite difference solution of the same problem.

Cooke, C. H.↗

Numerical analysis of complex fluid-flow systems

Very flexible computer-assisted numerical analysis is used to solve dynamic fluid-flow equations characterizing computer-controlled heat dissipation system developed for Space lab. Losses caused by bends, ties, fittings, valves, and like are easily included, and analysis can solve both steady-state and transient cases. It can also interact with parallel thermal analysis.

Holland, R. L.↗

Ultrasonic frequency analysis

Technique is used for evaluation and characterization of materials, fluids, and biological tissue. Method eliminates problem of electrical drive pulse shape by slaving tracking generator to local oscillator of spectrum analyzer. Logic/timing generator is used to control pulse transmission and receiving sequence, pulse width, and pulse repetition rate.

Cantrell, J. H.↗

Low cost cryostat

A cryostat for use in a low or a substantially gravity-free environment adapted to cool an experiment through the use of helium 2, or helium in its super fluid state is characterized by a number of interchangeable daughter dewars and helium supply or mother dewar. A low pressure venting system is provided for converting helium contained in the mother dewar to a superfluid state for use as a primary cryogen. Each daughter dewar is adapted to be removably mounted in mated relation on the mother dewar and is characterized by support for an experiment package, a source of helium to be employed as a secondary cryogen. A heat pipe is suspended from each daughter dewar and adapted to be extended into the mother dewar for facilitating cooling of the secondary cryogen. A transfer of heat from the package to the primary cryogen, via the secondary cryogen, is accommodated as a film flow of helium 2 progresses from the heat pipe to the experiment dewar.

Stephens, J. B.↗

U-Th-Pb, Rb-Sr, and Sm-Nd isotopic systematics of lunar troctolitic cumulate 76535 - Implications on the age and origin of this early lunar, deep-seated cumulate

The U-Th-Pb, Rb-Sr, and Sm-Nd isotopic systematics of four lightly leached residues of pristine, high-Mg, troctolitic cumulate 76535 were analyzed in order to determine their ages and magma sources. The data indicate that the cumulate was in isotopic equilibrium with a fluid or magma characterized by a high U-238/Pb-204 (mu) value of 600 at 4.236 Ga. Two and three stage Pb evolution calculations define even greater source mu values of about 1000, assuming low lunar initial mu values between 5 and 40 prior to about 4.43 Ga. These results are similar to mu values for KREEP sources and are also consistent with values from 78235, suggesting that at least some high-Mg suite rocks were derived from magma sources with high-mu values similar to KREEP, and support that idea that these rocks postdate primary lunar differentiation and formation of ferroan anorthosites.

Premo, Wayne R.↗

Investigations in Martian Sedimentology

The purpose of this report is to investigate and discuss the Martian surface. This report was done in specific tasks. The tasks were: characterization of Martian fluids and chemical sediments; mass wasting and ground collapse in terrains of volatile-rich deposits; Mars Rover terrestrial field investigations; Mars Pathfinder operations support; and Martian subsurface water instrument.

Moore, Jeffrey M.↗

Novel Optical Diagnostic Techniques for Studying Particle Deposition Upon Large Cylinders in a Sheared Suspension

On a twelve-month voyage to Mars, one astronaut will require at least two tons of potable water and two tons of pure oxygen. Efficient, reliable fluid reclamation is therefore necessary for manned space exploration. Space habitats require a compact, flexible, and robust apparatus capable of solid-fluid mechanical separation over a wide range of fluid and particle densities and particle sizes. In space, centrifugal filtration, where particles suspended in fluid are captured by rotating fixed-fiber mat filters, is a logical candidate for mechanical separation. Non-colloidal particles are deposited on the fibers due to inertial impaction or direct interception. Since rotation rates are easily adjustable, inertial effects are the most practical way to control separation rates for a wide variety of multiphase mixtures in variable gravity environments. Understanding how fluid inertia and differential fluid-particle inertia, characterized by the Reynolds and Stokes numbers, respectively, affect deposition is critical in optimizing filtration in a microgravity environment. This work will develop non-intrusive optical diagnostic techniques for directly visualizing where and when non-colloidal particles deposit upon, or contact, solid surfaces: 'particle proximity sensors'. To model particle deposition upon a single filter fiber, these sensors will be used in ground-based experiments to study particle dynamics as in the vicinity of a large (compared with the particles) cylinder in a simply sheared (i.e., linearly-varying, zero-mean velocity profile) neutrally-buoyant, refractive-index matched solid-liquid suspension.

Yoda, M.↗

Numerical Simulations of High Enthalpy Pulse Facilities

Axisymmetric flows within shock tubes and expansion tubes are simulated including the effects of finite rate chemistry and both laminar and turbulent boundary layers. The simulations demonstrate the usefulness of computational fluid dynamics for characterizing the flows in high enthalpy pulse facilities. The modeling and numerical requirements necessary to simulate these flows accurately are also discussed. Although there is a large body of analysis which explains and quantifies the boundary layer growth between the shock and the interface in a shock tube, there is a need for more detailed solutions. Phenomena such as thermochemical nonequilibrium. or turbulent transition behind the shock are excluded in the assumptions of Mirels' analysis. Additionally there is inadequate capability to predict the influence of the boundary layer on the expanded gas behind the interface. Quantifying the gas in this region is particularly important in expansion tubes because it is the location of the test gas. Unsteady simulations of the viscous flow in shock tubes are computationally expensive because they must follow features such as a shock wave over the length of the facility and simultaneously resolve the small length scales within the boundary layer. As a result, efficient numerical algorithms are required. The numerical approach of the present work is to solve the axisymmetric gas dynamic equations using an finite-volume formulation where the inviscid fluxes are computed with a upwind TVD scheme. Multiple species equations are included in the formulation so that finite-rate chemistry can be modeled. The simulations cluster grid points at the shock and interface and translate this clustered grid with these features to minimize numerical errors. The solutions are advanced at a CFL number of less than one based on the inviscid gas dynamics. To avoid limitations on the time step due to the viscous terms, these terms are treated implicitly. This requires a block tri-diagonal matrix inversion along each line of cells normal to the wall. The cost of this inversion is more than offset by the larger allowable time step. The source terms representing the finite-rate chemical kinetics are also treated implicitly. An algebraic turbulence model for compressible flow is used. The flow in a low pressure shock tube is computed and the results are compared with Mirels'analysis. The driven gas is nitrogen at 70 Pa, and the incident shock speed is approximately 2.9 km/sec so that there is little dissociation. The simulations include a laminar boundary layer and are run until the limiting flow regime is achieved. At this limit, the shock and interface travel at the same velocity because the amount of driven gas between these two features remains the same: the mass flow across the shock is equal to the mass of gas being entrained at the interface by the boundary layer. Simulations with several grids are presented to establish the grid independence of the solution, Good agreement is achieved between Mirels' correlations and the computations. This is expected since the flow conditions are chosen to be consistent with the assumptions used in Mirels' analysis. This comparison adds credibility to the numerical approach and highlights some of the differences between the theory and the detailed simulations. In addition, simulations of the HYPULSE expansion tube are presented for two operating conditions and the computations are compared to experimental data. The operating gas for both cases is nitrogen. One test condition is at a total enthalpy of 15.2 MJ/Kg and a relatively low pressure of 2 kPa. This case is characterized by a laminar boundary layer and significant chemical nonequilibrium. in the acceleration gas. The second test condition is at a total enthalpy of 10.2 MJ/Kg and a pressure of 38 kPa and is characterized by a turbulent boundary layer. The simulations compare well with experiment and reveal that the nonuniformity in pressure observed during the test time is related to variations in the boundary layer displacement thickness.

Wilson, Gregory J.↗

Probe for Sampling of Interstitial Fluid From Bone

An apparatus characterized as both a membrane probe and a bone ultrafiltration probe has been developed to enable in vivo sampling of interstitial fluid in bone. The probe makes it possible to measure the concentration of calcium and other constituents of the fluid that may be relevant to bone physiology. The probe could be especially helpful in experimental studies of microgravitational bone loss and of terrestrial bone-loss disease states, including osteoporosis. The probe can be implanted in the bone tissue of a living animal and can be used to extract samples of the interstitial bone fluid from time to time during a long-term study. The probe includes three 12-cm-long polyacrylonitrile fibers configured in a loop form and attached to polyurethane tubing [inside diameter 0.025 in. (0.64 mm), outside diameter 0.040 in. (1 mm)]; the attachment is made by use of a 1-cm-long connecting piece of polyurethane tubing [inside diameter 0.035 0.003 in. (0.89 0.08 mm), outside diameter 0.060 0.003 in. (1.52 0.08 mm)]. At the distal end, a 2-cm-long piece of polyurethane tubing of the same inner and outer diameters serves as a connector to a hub. A 1-cm long piece of expanded poly (tetrafluoroethylene) tubing over the joint between the fibers and the connecting tubing serves as a tissue-in-growth site.

Janle, Elsa M.↗

A Data Mining Project to Identify Cardiovascular Related Factors That May Contribute to Changes in Visual Acuity Within the US Astronaut Corps

Many of the cardiovascular-related adaptations that occur in the microgravity environment are due, in part, to a well-characterized cephalad-fluid shift that is evidenced by facial edema and decreased lower limb circumference. It is believed that most of these alterations occur as a compensatory response necessary to maintain a "normal" blood pressure and cardiac output while in space. However, data from both flight and analog research suggest that in some instances these microgravity-induced alterations may contribute to cardiovascular-related pathologies. Most concerning is the potential relation between the vision disturbances experienced by some long duration crewmembers and changes in cerebral blood flow and intra-ocular pressure. The purpose of this project was to identify cardiovascular measures that may potentially distinguish individuals at risk for visual disturbances after long duration space flight. Toward this goal, we constructed a dataset from Medical Operation tilt/stand test evaluations pre- (days L-15-L-5) and immediate post-flight (day R+0) on 20 (3 females, 17 males). We restricted our evaluation to only crewmembers who participated in both shuttle and space station missions. Data analysis was performed using both descriptive and analytical methods (Stata 11.2, College Station, TX) and are presented as means +/- 95% CI. Crewmembers averaged 5207 (3447 - 8934) flight hours across both long (MIR-23 through Expedition16) and short (STS-27 through STS-101) duration missions between 1988 and 2008. The mean age of the crew at the time of their most recent shuttle flight was 41 (34-44) compared to 47 (40-54) years during their time on station. In order to focus our analysis (we did not have codes to separate out subjects by symptomotology) , we performed a visual inspection of each cardiovascular measures captured during testing and plotted them against stand time, pre- to post-flight, and between mission duration. It was found that pulse pressure most clearly differentiated the two mission types. Statistical analysis confirmed that pulse pressure was significantly higher before [45.6; (42.1 to 49.1)] and after [50.7; (46.9 to 54.6)] time on station compared with their most recent shuttle flight [31.6 (27.8 to 35.4), and 32.2 (28.3 to 36.0) respectively] even after correcting differences in age and cumulative number of mission hours. Without knowing the identity of which long duration crewmembers demonstrated visual changes, we were limited to examining whether certain crew regulate components of pulse pressure, systolic and diastolic blood pressure, differently due to microgravity exposure. To that end, we stratified crew into tertiles based on either their pre-flight measure of systolic or diastolic blood pressure. Those crew in the highest tertile for both systolic (lower tertile (n=8; 103-111), middle tertile (n=7; 113-121), and upper tertile (n=5; 125-136) and diastolic blood pressure (lower tertile (n=8; 58-64), middle tertile (n=7; 67-73), and upper tertile (n=5; 75-81) demonstrated less variability in pulse pressure between R+0 and L-10 (Figure 2). Interestingly, those crewmembers with the highest resting systolic blood pressure demonstrated either no change or in some instances an increase in total peripheral resistance, where those in the lower tertiles had lower values of total peripheral resistance compared to pre-flight levels. In this study, it was found that crewmembers in the highest tertile for both systolic and diastolic blood pressure demonstrated less variability in pulse pressure and that the decrease in variability was due in part to lower levels of compliance as indicated by similar or higher levels of total peripheral resistance after compared with before flight levels. Whether there is a relation between blood pressure regulation and total peripheral resistance in crew presenting with negative changes in visual acuity remains unknown.

Westby, Christian M.↗

LADEE Propulsion System Cold Flow Test

Lunar Atmosphere and Dust Environment Explorer (LADEE) is a NASA mission that will orbit the Moon. Its main objective is to characterize the atmosphere and lunar dust environment. The spacecraft development is being led by NASA Ames Research Center and scheduled for launch in 2013. The LADEE spacecraft will be operated with a bi-propellant hypergolic propulsion system using MMH and NTO as the fuel and oxidizer, respectively. The propulsion system utilizes flight-proven hardware on major components. The propulsion layout is composed of one 100-lbf main thruster and four 5-lbf RCS thrusters. The propellants are stored in four tanks (two parallel-connected tanks per propellant component). The propellants will be pressurized by regulated helium. A simulated propulsion system has been built for conducting cold flow test series to characterize the transient fluid flow of the propulsion system feed lines and to verify the critical operation modes, such as system priming, waterhammer, and crucial mission duty cycles. Propellant drainage differential between propellant tanks will also be assessed. Since the oxidizer feed line system has a higher flow demand than the fuel system does, the cold flow test focuses on the oxidizer system. The objective of the cold flow test is to simulate the LADEE propulsion fluid flow operation through water cold flow test and to obtain data for anchoring analytical models. The models will be used to predict the transient and steady state flow behaviors in the actual flight operations. The test activities, including the simulated propulsion test article, cold flow test, and analytical modeling, are being performed at NASA Marshall Space Flight Center. At the time of the abstract submission, the test article checkout is being performed. The test series will be completed by November, 2012

Williams, Jonathan Hunter↗

Resource Prospector Propulsion System Cold Flow Testing

Resource Prospector (RP) is a NASA mission being led by NASA Ames Research Center with current plans to deliver a scientific payload package aboard a rover to the lunar surface. As part of an early risk reduction activity, Marshall Space Flight Center (MSFC) and Johnson Space Flight Center (JSC) have jointly developed a government-version concept of a lunar lander for the mission. The spacecraft consists of two parts, the lander and the rover which carries the scientific instruments. The lander holds the rover during launch, cruise, and landing on the surface. Following terminal descent and landing the lander portion of the spacecraft become dormant after the rover embarks on the science mission. The lander will be equipped with a propulsion system for lunar descent and landing, as well as trajectory correction and attitude control maneuvers during transit to the moon. Hypergolic propellants monomethyl hydrazine and nitrogen tetroxide will be used to fuel sixteen 70-lbf descent thrusters and twelve 5-lbf attitude control thrusters. A total of four metal-diaphragm tanks, two per propellant, will be used along with a high-pressure composite-overwrapped pressure vessel for the helium pressurant gas. Many of the major propulsion system components are heritage missile hardware obtained by NASA from the Air Force. In parallel with the flight system design activities, a simulated propulsion system based on flight drawings was built for conducting a series of water flow tests to characterize the transient fluid flow of the propulsion system feed lines and to verify the critical operation modes such as system priming, waterhammer, and crucial mission duty cycles. The primary objective of the cold flow testing was to simulate the RP propulsion system fluid flow operation through water flow testing and to obtain data for anchoring analytical models. The models will be used to predict the transient and steady state flow behaviors in the actual flight operations. All design and build efforts, including the analytical modeling, have been performed. The cold flow testing of the propulsion system was set up and conducted at a NASA MSFC test facility. All testing was completed in the summer of 2014, and this paper documents the results of that testing and the associated fluid system modeling efforts.

Williams, Hunter↗