Proof-mass actuator placement strategies for regulation of flexure during the SCOLE slew
An analysis was performed in order to find the best placement for proof-mass actuators and to determine the importance of placement, i.e., what is the sensitivity of beam flexure to actuator placement. The analysis was performed by using the NASTRAN finite element model for a flexible beam with 21 grid points on beam, by using the nonlinear DISCOS simulation of 20 deg slew and the use of a closed-loop linear quadratic regulator (lqr). Some conclusions reached are: (1) proof-mass actuators can reduce flexure amplitude and damp oscillations; (2) amplitude of deformations during slew is relatively insensitive to placement of actuators; (3) damping factor of oscillations is sensitive to actuator placement; and (4) the degree of controllability method indicates most effective placement for actuators.