Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flexible generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Low-Cost Sulfur Thermal Storage for Increased Flexibility and Improved Economics of Fossil-Fueled Electricity Generating Units (Final Report)

The US electric grid relies on conventional fossil fuel power plants for reliable and secure power, but these plants suffer from physical and financial strain due to the influx of inexpensive and variable solar and wind electricity. Conventional power plants need to generate electricity flexibly and on-demand to accommodate these renewable resources on the grid. Integrating a low-cost thermal energy storage (TES) gives fossil assets the ability to regulate their output efficiently and optimize the plant operation to maximize revenue in the wholesale electricity market. Element 16’s TES concept uses sulfur, a byproduct of the oil & gas industry, as the storage media that is 10 times cheaper than molten salt used in commercial two-tank TES technology. In this project, the team completed a detailed feasibility and technoeconomic study establishing the impact, cost and performance of molten sulfur TES system integrated with fossil assets.

20 FOSSIL-FUELED POWER PLANTS↗

Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation

This National Energy Technology Laboratory (NETL) study addresses the conceptual design of greenfield pulverized coal (PC) plants intended for flexible rather than high capacity factor baseload operation. The United States has plentiful, low-cost natural gas resources - studies of aggressive decarbonization scenarios of the US energy sector suggest that the variability of carbon-free power can be economically addressed using dispatchable natural gas-fueled generation. Globally, natural gas resources are not as plentiful or low cost; consequently, some regions of the world are anticipated to continue to rely upon coal generation, even as they pursue decarbonization efforts. To support the increased utilization of variable renewable generation in these coal-dependent regions, plant designs must target low-capacity factor coal plants with increased emphasis on flexibility attributes such as start-up times, ramp rates, minimum load, and part-load heat rates. While much work has been performed on the improvement of the flexibility for existing coal plants originally designed for baseload service, little public literature exists on clean sheet design for flexible operation. This conceptual design study aims to define the features, performance characteristics, and costs for greenfield coal plants intended for flexible operation. Quantifying these characteristics provides critical information required by utility owners, grid planners, energy market modelers, and energy policy decision makers in coal-dependent regions of the world to better understand how coal-fired power plants can support a transition to low carbon generation.

20 FOSSIL-FUELED POWER PLANTS↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

A Flexible Operation of Distributed Generation in Distribution Networks With Dynamic Boundaries

Distributed generators performing black start to form isolated microgrids offer a flexible and resilient solution to service restoration in distribution systems. Employing the dynamic microgrid concept, distributed generators can form isolated microgrids by changing their physical boundaries through smart switches and conventional circuit breakers. However, the flexibility of distributed generators has not been thoroughly investigated and utilised in existing works. To address this issue, this letter presents a new model to the reconfiguration formulation in active distribution networks considering different operation modes of distributed generators. Compared with the existing models, this study provides a new formulation supporting different DGs' operation modes and fully making use of their flexibility. Illustrative results on IEEE 34-test systems verify the effectiveness of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Argon Power Cycle, a zero emission, flexible and reliable power generation technology

The proposed project was aimed at assisting in the development of the Argon Power Cycle (APC), a zero emission, flexible, and efficient power generation technology. In the effort of bringing the APC to the market, NTS proposed in the scope of this project several partial but key activities to advance the development of the APC. These tasks encompassed 1) the analysis of the market, developing a techno-economic model with integrated market inputs, 2) further optimization of our chemical kinetics models for more accurate simulation of the process and 3) scale up of our original prototype to a larger, commercially viable platform. NTS expanded on this scope of work to secure additional R&D funding in amounts north of $7M, carry out customer discovery with the sponsorship of the NSF and grow the team’s engineering talent.

33 ADVANCED PROPULSION SYSTEMS↗

Analysis of curtailment at The Geysers geothermal Field, California

Geothermal energy has traditionally been viewed as a baseload energy source, but the rapid growth of intermittent renewable energy has led to a need for more flexibility in power generation to avoid mandatory curtailment imposed by grid operators. This study of curtailment at The Geysers provides insights into the magnitude, duration, frequency, temporal and spatial distribution, and potential causes of curtailment events between 2013 and 2018. Annual levels of curtailment range during this period from 9 to 47 GW h, representing 0.15 to 0.81 % of the net generation. Most curtailments occurred at the power plants connected to a lower capacity transmission line and may result from transmission constriction. There is a clear link between negative pricing and economic curtailment, especially when solar production is higher. Economic curtailment events tend to be only a few hours and vary in magnitude up to almost 300 MW, whereas transmission-related curtailment events can be up to several weeks in duration. It is likely that curtailment of geothermal power will be an increasing concern, and could be mitigated by flexible generation strategies and increases in energy storage. It is critical to know the nature of curtailment events so that flexible generation options can be assessed properly.

15 GEOTHERMAL ENERGY↗

Design and optimization of flexible decoupled high-temperature gas-cooled reactor plants with thermal energy storage

Advanced nuclear power plants are well-positioned for future zero-carbon grids, however, the need for flexible power generation will be required over the traditional emphasis on baseload generation for meeting historical demands. To achieve such flexibility, this work examines viable configurations for coupling nuclear energy production with thermal energy storage. Previous designs on nuclear-thermal energy storage configurations for advanced reactor designs, which utilized reactor steam as the heat source for charging the thermal energy storage, are restricted by the heat diversion ratio and efficiency losses, thus their impacts can be limited. In this context, this study proposes configurations for fully decoupling the nuclear reactor from the power cycle and positioning the storage as an intermediate loop, thereby achieving an unconstrained heat diversion ratio and improved efficiency. Compared with a standard high-temperature gas-cooled reactor’s power cycle, steady-state thermodynamic modeling and dispatch optimizations quantify the benefits of a steam reheat cycle within the fully decoupled thermal energy system to separate the plant cycle from the high-pressure primary side. These benefits are further detailed, compatible with required high-temperature and high-pressure conditions, through (1) open-source dynamic transient models that examine the impact of off-design operation on the systems, (2) the investigation of components design and costing and finally (3) sizing and dispatch optimization. The fully-decoupled design achieves a cycle efficiency of 43.1%, an enhancement over the vendor’s standard efficiency of 42.2% (Xe-100 design). Here, the proposed design offers strengthened physical barriers from the nuclear island as well as superior operational flexibility and power boosting. Dispatch optimization and market analysis reveal that thermal energy storage size is highly dependent on the peak patterns of electricity prices and the minimum generation level constraint imposed on the balance of plant. Evaluation of off-design operation demonstrates that the full decoupling design with the suggested fail-safe control mechanisms ensures a minimal impact on reactor parameters, even during rapid power ramping.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flexible Plant Operation and Generation Technical Program Plan for FY2023

This report presents the Technical Program Plan for Fiscal Years 2023-2027 (FY2023 to FY2027) for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability Program—Flexible Plant Operation and Generation Research Pathway. The objective of this pathway is to carry out the research needed to help nuclear power plants diversify revenue generation for the life of these plants. The purpose of these research and development activities is two fold: (1) to reduce the technical and economic risks of implementing FPOG applications and (2) to provide guidance on relevant safety and environmental operating license reviews, amendments, and renewals. This pathway provides a clear understanding of the benefits of nuclear energy beyond electricity markets. A detailed description of the research and development activities that have been completed and that are planned for FY2023—FY2027 are presented in this report. These activities include completing the development of analysis tools to perform technical and economic assessments of realistic market opportunities for producing secondary energy products near nuclear power plants. They also include developing and demonstrating engineering systems and control concepts to dispatch thermal and electrical power to an industrial user. Additionally, this plan includes developing guidance for addressing potential regulatory and licensing requirements. In addition, the formation, purpose, and activities of a group referred to as the Hydrogen Regulatory Research and Review Group is discussed. An overview is also provided on the potential benefits of the Infrastructure Investment and Jobs Act (IIJA) Bill that will support the commencement of Regional Clean Hydrogen Hubs, and the Inflation Reduction Act (IRA) that provides compelling production tax credits for nuclear electricity and clean hydrogen using nuclear energy.

08 HYDROGEN↗

An integer- N frequency synthesizer for flexible on-chip clock generation

A low-power integer-N frequency synthesizer for flexible on-chip clock generation has been designed in a 65 nm CMOS process. The circuit can be programmed to generate two independent low-jitter clocks between 30 MHz and 3 GHz that are locked to a 10–50 MHz reference input. The design uses a phase-locked loop (PLL) with a dual-tuned LC voltage-controlled oscillator (VCO), programmable feedback divider, and dual output dividers. The total power consumption from 1.2 V and 0.8 V supplies is 4.0 mW. In conclusion, experimental results confirm the functionality of the proposed synthesizer over a wide range of output frequencies.

47 OTHER INSTRUMENTATION↗

Flexible Siting Criteria and Staff Minimization for Micro-Reactors

The economic potential of micro-reactors is vast and underestimated. Commonly-emphasized applications include niche markets such as remote communities, mines and military bases. However, micro-reactors could be used as flexible energy generators also for larger markets, such as mobile and containerized agriculture and manufacturing facilities, district heating, micro-grids for data centers, sea ports, airports and hospitals. The implication is that micro-reactors may have to be deployed also in non-remote locations. Successful implementation of micro-reactors needs a navigable and predictable licensing process, technology-appropriate siting restrictions, risk-informed emergency and safety requirements, and practical operating and maintenance requirements. The primary goal of this project was to develop siting criteria that are tailored to micro-reactors deployable in densely-populated areas, e.g., urban environments. To achieve that goal, we compared the characteristics of the MIT research reactor (MITR) with those of leading micro-reactor concepts (e.g., eVinci, USNC, Aurora), and evaluated whether and how the MITR design basis (e.g., inherent safety features, engineered safety systems, source term, emergency planning and emergency operating procedures) and associated regulations may be applicable to these new micro-reactors as well. What makes MITR a unique analogue in this context is its small power rating (6 MWt) and physical size, mode of operations (24/7 with a somewhat more commercial flavor than typical university reactors), and especially its urban location. Of course significant differences exist, such as mission (power production vs. research) and the reactor design itself. Leveraging the MITR experience, this project was able to generate criteria that will allow micro-reactors to realize their full economic potential as flexible heat and electricity generators for a diverse portfolio of applications in non-remote locations. As such, the outcome of this project might encourage investment in and use of micro-reactors. A second goal of the project was to conceptualize a model of operations for micro-reactors that would minimize the staffing requirements, and thus reduce the cost of electricity and heat generated by these systems. Here too our approach was to systematically review the MITR experience and requirements, as well as survey the innovations in autonomous control technologies and monitoring (e.g., advanced sensors, drones, robotics, AI) that would permit a dramatic reduction in staffing at future micro-reactor installations. The scope of work was expanded after the start date to include also an evaluation of micro-reactor security, using the so-called consequence-based analysis, and the development of a methodology to perform dynamic risk assessment for micro-reactors, using system theory and modeling and simulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exploiting Task Tolerances in Mimicry-based Telemanipulation

We explore task tolerances, i.e., allowable position or rotation inaccuracy, as an important resource to facilitate smooth and effective telemanipulation. Task tolerances provide a robot flexibility to generate smooth and feasible motions; however, in teleoperation, this flexibility may make the user’s control less direct. In this work, we implemented a telema nipulation system that allows a robot to autonomously adjust its configuration within task tolerances. We conducted a user study comparing a telemanipulation paradigm that exploits task tolerances (functional mimicry) to a paradigm that requires the robot to exactly mimic its human operator (exact mimicry), and assess how the choice in paradigm shapes user experience and task performance. Our results show that autonomous adjustments within task tolerances can lead to performance improvements without sacrificing perceived control of the robot. Additionally, we find that users perceive the robot to be more under control, predictable, fluent, and trustworthy in functional mimicry than in exact mimicry.

42 ENGINEERING↗

Hierarchical Transactive Control of Flexible Building Loads Under Distribution LMP

With grid modernization efforts, future distribution networks, which consist of various distributed generators and flexible loads, will be more flexible and active. All new network components of distributed energy resources (DERs) drive and enable the transition towards a market-based distribution net-work that seeks the optimal allocation of all DERs. To address challenges associated with DERs, one promising solution is to utilize demand-side flexibility of building loads facilitated by demand response (DR) programs and provide ancillary grid services through distribution-level markets. Under this new paradigm, this paper proposes an efficient DR management strategy incorporating emerging price signals of distribution markets, i.e., distribution locational marginal price (DLMP), based on a hierarchical transactive control approach. The proposed approach establishes a two-layer decision-making framework; the upper layer formulates a bilevel model to obtain an optimal demand response (ODR) under DLMP, and the lower layer employs model-free control to dispatch the (aggregated) ODR to individual end users. Numerical case studies using a modified IEEE 33 test network are performed to verify the effectiveness of the proposed approach; load shifting and peak shaving for the distribution system operator and payments’ reduction for end users while maintaining their comfort.

Park, Byungkwon↗

Improving operational flexibility of integrated energy system with uncertain renewable generations considering thermal inertia of buildings

Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.

30 DIRECT ENERGY CONVERSION↗

Impacts of climate change on subannual hydropower generation: a multi-model assessment of the United States federal hydropower plant

Abstract Hydropower is a low-carbon emission renewable energy source that provides competitive and flexible electricity generation and is essential to the evolving power grid in the context of decarbonization. Assessing hydropower availability in a changing climate is technically challenging because there is a lack of consensus in the modeling representation of key dynamics across scales and processes. Focusing on 132 US federal hydropower plants, in this study we evaluate the compounded impact of climate and reservoir-hydropower models’ structural uncertainties on monthly hydropower projections. In particular, instead of relying on one single regression-based hydropower model, we introduce another conceptual reservoir operations-hydropower model in the assessment framework. This multi-model assessment approach allows us to partition uncertainties associated with both climate and hydropower models for better clarity. Results suggest that while at least 70% of the uncertainties at the annual scale and 50% at the seasonal scale can be attributed to the choice of climate models, up to 50% of seasonal variability can be attributed to the choice of hydropower models, particularly in regions over the western US where the reservoir storage is substantial. The analysis identifies regions where multi-model assessments are needed and presents a novel approach to partition uncertainties in hydropower projections. Another outcome includes an updated evaluation of Coupled Model Intercomparison Project Phase 5 (CMIP5)-based federal hydropower projection, at the monthly scale and with a larger ensemble, which can provide a baseline for understanding future assessments based on CMIP6 and beyond.

54 ENVIRONMENTAL SCIENCES↗