Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluating Suit Fit Using Performance Degradation

The Mark III suit has multiple sizes of suit components (arm, leg, and gloves) as well as sizing inserts to tailor the fit of the suit to an individual. This study sought to determine a way to identify the point an ideal suit fit transforms into a bad fit and how to quantify this breakdown using mobility-based physical performance data. This study examined the changes in human physical performance via degradation of the elbow and wrist range of motion of the planetary suit prototype (Mark III) with respect to changes in sizing and as well as how to apply that knowledge to suit sizing options and improvements in suit fit. The methods implemented in this study focused on changes in elbow and wrist mobility due to incremental suit sizing modifications. This incremental sizing was within a range that included both optimum and poor fit. Suited range of motion data was collected using a motion analysis system for nine isolated and functional tasks encompassing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm only. The results were then compared across sizing configurations. The results of this study indicate that range of motion may be used as a viable parameter to quantify at what stage suit sizing causes a detriment in performance; however the human performance decrement appeared to be based on the interaction of multiple joints along a limb, not a single joint angle. The study was able to identify a preliminary method to quantify the impact of size on performance and to develop a means to gauge tolerances around optimal size. More work is needed to improve the assessment of optimal fit and to compensate for multiple joint interactions.

Margerum, Sarah E.↗

An Improved Cryosat-2 Sea Ice Freeboard Retrieval Algorithm Through the Use of Waveform Fitting

We develop an empirical model capable of simulating the mean echo power cross product of CryoSat-2 SAR and SAR In mode waveforms over sea ice covered regions. The model simulations are used to show the importance of variations in the radar backscatter coefficient with incidence angle and surface roughness for the retrieval of surfaceelevation of both sea ice floes and leads. The numerical model is used to fit CryoSat-2 waveforms to enable retrieval of surface elevation through the use of look-up tables and a bounded trust region Newton least squares fitting approach. The use of a model to fit returns from sea ice regions offers advantages over currently used threshold retrackingmethods which are here shown to be sensitive to the combined effect of bandwidth limited range resolution and surface roughness variations. Laxon et al. (2013) have compared ice thickness results from CryoSat-2 and IceBridge, and found good agreement, however consistent assumptions about the snow depth and density of sea ice werenot used in the comparisons. To address this issue, we directly compare ice freeboard and thickness retrievals from the waveform fitting and threshold tracker methods of CryoSat-2 to Operation IceBridge data using a consistent set of parameterizations. For three IceBridge campaign periods from March 20112013, mean differences (CryoSat-2 IceBridge) of 0.144m and 1.351m are respectively found between the freeboard and thickness retrievals using a 50 sea ice floe threshold retracker, while mean differences of 0.019m and 0.182m are found when using the waveform fitting method. This suggests the waveform fitting technique is capable of better reconciling the seaice thickness data record from laser and radar altimetry data sets through the usage of consistent physical assumptions.

CryoSat-2↗

Fitting Leak Test Report

Many Human Landing System flight elements are anticipated to implement mechanically connected joints in cryogenic fluid lines to simplify system assembly. These joints will need to survive launch vibration, while cold, and remain as leak‐free as possible to minimize commodity loss. Threaded fluid fittings should be qualified for use in their expected environments to reduce risk and ensure mission success. A new ground‐based test apparatus was developed and validated to obtain quantifiable low leak rate test data for a small component, such as a pressurized threaded fluid fitting, while in the temperature range of liquid hydrogen. A cryocooler is used to attain the cold test temperature and helium leakage from a pressurized fitting mounted within a vacuum test chamber is measured using a mass spectrometer leak detector. Two different sizes of Swagelok VCR fittings with three different types of seal rings were selected as the test articles for the initial proof of concept testing. Each fitting configuration was subjected to two consecutive cryogenic thermal cycles and cold leak measurement tests, followed by exposure to a high vibration test profile at ambient temperature on a shaker table, and then two additional cold leak measurement tests. Very low leak rates, below the acceptable leak rate threshold, were measured at the pressures tested. Several enhancements to the test hardware are discussed that would facilitate a comprehensive fitting qualification test campaign by enabling a higher test throughput rate and ensuring a repeatable test profile.

Cryogenic Fluid Management↗

Press-fit Connectors in Spaceflight Applications - Drivers and Challenges

Starting from the 1970s when press-fit technology was nascent and confined within the telecommunications industry, this technology has matured as its adoption has increased within high reliability applications such as medical devices and avionics. Press-fit connectors are strongly preferred in today’s designs because the smaller press-fit pins require smaller diameter holes which require smaller pads and allows more routing real-estate without taking exceptions to specs. The lack of solder for a press-fit connection makes the conductive path more predictable for high-speed digital design and impedance discontinuities can be minimized as the signal moves from the printed circuit board to the connector. Touch-up during manufacturing is also reduced and streamlines the assembly process. This presentation at the 2022 NEPP ETW will introduce the audience to press-fit connectors and its contact physics followed by a deeper dive into specific press-fit applications for space flight environments, including information on qualification, testing, and screening.

pressfit↗

INFLUENCE OF ACTN3 GENE ON MUSCLE HEALTH AND PHYSICAL FITNESS TO INFORM FUTURE INTERVENTIONS IN SPACEFLIGHT MISSIONS

INTRODUCTION: Exposure to reduced gravity environments leads to diminished muscle size, strength, and endurance. Preservation of physical fitness is critical for mission essential tasks such as extravehicular activities or adaptation to changes in gravity loads. Current countermeasures to maintain ISS astronauts’ muscle mass and fitness include dedicated time for a combination of cardiovascular exercise and resistance training. Countermeasure effectiveness is monitored through VO2 max and isometric mid-thigh pulls. It is important to understand both environmental and genetic contributors to astronaut physical fitness. Multiple genes, including ACTN3, are known to correlate with exercise phenotypes and have the potential to help personalize countermeasures based on an astronaut’s genotypic makeup. TOPIC: The ACTN3 gene encodes a protein expressed only in fast-twitch muscles and correlates with sprint and power phenotypes. A common polymorphism in ACTN3 gene is R577X (rs1815739), produced by a C−to−T base substitution resulting in a nonsense mutation from arginine (R) to a premature stop codon (X) present in approximately 18% of the population. This polymorphism causes an absence of α−actinin−3 in type II muscle fibers but does not lead to a disease phenotype. The RR genotype is associated with elite athletes, especially in sprint and power sports. The XX genotype is believed to be more common in endurance athletes. The ACTN3 gene also has potential associations with training adaptation, post-exercise recovery, and exercise-associated injuries. APPLICATION: Understanding how ACTN3 and other genetic determinates of fitness phenotypes affect astronaut physical performance can inform personalized exercise and recovery prescriptions. For example, individuals with the RR or RX genotype may respond better to high-load and low repetition exercise, while XX may benefit from high repetition with low weight exercise. Since the wild-type protein may confer more resistance to muscle damage, those individuals with the RR or RX genotype may benefit from high intensity interval training for improved VO2 max, whereas those with an XX genotype may benefit from low intensity, high volume endurance activity. Additionally, omics data related to health and performance could be used as biomarkers to monitor astronaut fitness and the effectiveness of training regimens during a mission. Learning objectives: • Learn about the phenotypic effects on muscle function and fitness secondary to R577X mutation in the ACTN3 gene • Learn how mutations in the ACTN3 gene may inform future countermeasures for future spaceflight missions

Lynn K Stanwyck↗

A Dynamic Trajectory Fit to Multisensor Fireball Observations

Meteorites with known orbital origins are key to our understanding of solar system formation and the source of life on Earth. Fireball networks have been developed globally in a unified effort to record and ultimately retrieve these cosmic samples. However, the accuracy of the determined orbit and the likelihood of meteorite recovery depend directly on the accuracy of the chosen meteoroid triangulation method. There are three leading techniques for meteoroid triangulation discussed in the literature: the method of planes, the straight-line least-squares method, and the multiparameter fit method. Here we describe an alternative method to meteoroid triangulation, called the dynamic trajectory fit. This approach uses the meteoroid’s 3D dynamic equations of motion to fit a realistic trajectory directly to multisensor line-of-sight observations. This method has the ability to resolve fragmentation events, fit systematic observatory timing offsets, and determine mass estimates of the meteoroid along its observable trajectory. Through a comprehensive Monte Carlo analysis of over 100,000 trajectory simulations, we find this new method to more accurately estimate meteoroid trajectories of slow entry events (<25 km s{sup −1}) and events observed from low convergence angles (<10°) compared to existing meteoroid triangulation techniques. Additionally, we triangulate an observed fireball event with visible fragmentation using the various triangulation methods to show that the proposed dynamic trajectory fit implementing fragmentation to best match the captured multisensor line-of-sight data.

79 ASTRONOMY AND ASTROPHYSICS↗

Differential baroreflex control of heart rate in sedentary and aerobically fit individuals

PURPOSE: We compared arterial, aortic, and carotid-cardiac baroreflex sensitivity in eight average fit (maximal oxygen uptake, VO2max = 42.2+/-1.9 mL x kg(-1) x min(-1)) and eight high fit (VO2max = 61.9+/-2.2 mL x kg(-1) x min(-1)) healthy young adults. METHODS: Arterial and aortic (ABR) baroreflex functions were assessed utilizing hypo- and hyper-tensive challenges induced by graded bolus injections of sodium nitroprusside (SN) and phenylephrine (PE), respectively. Carotid baroreflex (CBR) sensitivity was determined using ramped 5-s pulses of both pressure and suction delivered to the carotid sinus via a neck chamber collar, independent of drug administration. RESULTS: During vasoactive drug injection, mean arterial pressure (MAP) was similarly altered in average fit (AF) and high fit (HF) groups. However, the heart rate (HR) response range of the arterial baroreflex was significantly attenuated (P < 0.05) in HF (31+/-4 beats x min(-1)) compared with AF individuals (46+/-4 beats x min(-1)). When sustained neck suction and pressure were applied to counteract altered carotid sinus pressure during SN and PE administration, isolating the ABR response, the response range remained diminished (P < 0.05) in the HF population (24+/-3 beats x min(-1)) compared with the AF group (41+/-4 beats x min(-1)). During CBR perturbation, the HF (14+/-1 beats-min(-1)) and AF (16+/-1 beats-min(-1)) response ranges were similar. The arterial baroreflex response range was significantly less than the simple sum of the CBR and ABR (HF, 38+/-3 beats x min(-1) and AF, 57+/-4 beats x min(-1)) in both fitness groups. CONCLUSIONS: These data confirm that reductions in arterial-cardiac reflex sensitivity are mediated by diminished ABR function. More importantly, these data suggest that the integrative relationship between the ABR and CBR contributing to arterial baroreflex control of HR is inhibitory in nature and not altered by exercise training.

NASA Discipline Cardiopulmonary↗

A combinatorially complete epistatic fitness landscape in an enzyme active site

Protein engineering often targets binding pockets or active sites which are enriched in epistasis—nonadditive interactions between amino acid substitutions—and where the combined effects of multiple single substitutions are difficult to predict. Few existing sequence-fitness datasets capture epistasis at large scale, especially for enzyme catalysis, limiting the development and assessment of model-guided enzyme engineering approaches. We present here a combinatorially complete, 160,000-variant fitness landscape across four residues in the active site of an enzyme. Assaying the native reaction of a thermostable β-subunit of tryptophan synthase (TrpB) in a nonnative environment yielded a landscape characterized by significant epistasis and many local optima. These effects prevent simulated directed evolution approaches from efficiently reaching the global optimum. There is nonetheless wide variability in the effectiveness of different directed evolution approaches, which together provide experimental benchmarks for computational and machine learning workflows. The most-fit TrpB variants contain a substitution that is nearly absent in natural TrpB sequences—a result that conservation-based predictions would not capture. Thus, although fitness prediction using evolutionary data can enrich in more-active variants, these approaches struggle to identify and differentiate among the most-active variants, even for this near-native function. Overall, this work presents a large-scale testing ground for model-guided enzyme engineering and suggests that efficient navigation of epistatic fitness landscapes can be improved by advances in both machine learning and physical modeling.

biocatalysis↗

Modelling the Milky Way – I. Method and first results fitting the thick disc and halo with DES-Y3 data

ABSTRACT We present a technique to fit the stellar components of the Galaxy by comparing Hess Diagrams (HDs) generated from trilegal models to real data. We apply this technique, which we call mwfitting, to photometric data from the first 3 yr of the Dark Energy Survey (DES). After removing regions containing known resolved stellar systems such as globular clusters, dwarf galaxies, nearby galaxies, the Large Magellanic Cloud, and the Sagittarius Stream, our main sample spans a total area of ∼2300 deg2. We further explore a smaller subset (∼1300 deg2) that excludes all regions with known stellar streams and stellar overdensities. Validation tests on synthetic data possessing similar properties to the DES data show that the method is able to recover input parameters with a precision better than 3 per cent. We fit the DES data with an exponential thick disc model and an oblate double power-law halo model. We find that the best-fitting thick disc model has radial and vertical scale heights of 2.67 ± 0.09 kpc and 925 ± 40 pc, respectively. The stellar halo is fit with a broken power-law density profile with an oblateness of 0.75 ± 0.01, an inner index of 1.82 ± 0.08, an outer index of 4.14 ± 0.05, and a break at 18.52 ± 0.27 kpc from the Galactic centre. Several previously discovered stellar overdensities are recovered in the residual stellar density map, showing the reliability of mwfitting in determining the Galactic components. Simulations made with the best-fitting parameters are a promising way to predict Milky Way star counts for surveys such as the LSST and Euclid.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Abridged spectral matrix inversion: parametric fitting of X-ray fluorescence spectra following integrative data reduction

Recent improvements in both X-ray detectors and readout speeds have led to a substantial increase in the volume of X-ray fluorescence data being produced at synchrotron facilities. This in turn results in increased challenges associated with processing and fitting such data, both temporally and computationally. Herein an abridging approach is described that both reduces and partially integrates X-ray fluorescence (XRF) data sets to obtain a fivefold total improvement in processing time with negligible decrease in quality of fitting. The approach is demonstrated using linear least-squares matrix inversion on XRF data with strongly overlapping fluorescent peaks. This approach is applicable to any type of linear algebra based fitting algorithm to fit spectra containing overlapping signals wherein the spectra also contain unimportant (non-characteristic) regions which add little (or no) weight to fitted values, e.g. energy regions in XRF spectra that contain little or no peak information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dry heat sterilization as a method to recycle N95 respirator masks: The importance of fit

In times of crisis, including the current COVID-19 pandemic, the supply chain of filtering facepiece respirators, such as N95 respirators, are disrupted. To combat shortages of N95 respirators, many institutions were forced to decontaminate and reuse respirators. While several reports have evaluated the impact on filtration as a measurement of preservation of respirator function after decontamination, the equally important fact of maintaining proper fit to the users’ face has been understudied. In the current study, we demonstrate the complete inactivation of SARS-CoV-2 and preservation of fit test performance of N95 respirators following treatment with dry heat. We apply scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM/EDS), X-ray diffraction (XRD) measurements, Raman spectroscopy, and contact angle measurements to analyze filter material changes as a consequence of different decontamination treatments. We further compared the integrity of the respirator after autoclaving versus dry heat treatment via quantitative fit testing and found that autoclaving, but not dry heat, causes the fit of the respirator onto the users face to fail, thereby rendering the decontaminated respirator unusable. Our findings highlight the importance to account for both efficacy of disinfection and mask fit when reprocessing respirators to for clinical redeployment.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Analytic fits to atom-in-jellium shear modulus predictions

Fits to AJ shear modulus calculations from ρ0 to the limit of the corresponding AJ EOS table (usually 1000 ρ0), adjusted to reproduce STP shear modulus where possible. Fitting minimized the fractional difference, so low-pressure points would be reproduced accurately despite the wide-ranging tabulation. AJ calculations were at T=0. Isochoric variation G(T) has been small for all cases spot-tested so far, and may have either sign. The fitted equation usually matches the AJ data to within a few percent. Between numerical noise in the AJ calculation and probably-physical structure not captured by the equation, the deviation could be up to 20% in some places in most models, and 30% in a few. AJ does not capture structural phase transitions or phases stabilized by directional bonds, where the shear modulus may vary by a greater amount. Where possible, STP ρ,G were used as parameters, and low pressure AJ points were de-weighted or removed if necessary. Otherwise, such as where AJ fails to capture solid phases with a significantly different shear modulus, the AJ data were fitted as far down in pressure as possible, G0 was also fitted if necessary, and ρ0 was also adjusted if needed to keep G0>0. The resulting models are not intended for use at low pressure, though some are probably adequate for practical purposes

36 MATERIALS SCIENCE↗

GADRAS-DRF Validation for Safeguards and Custom Peak Fit Enhancements

In previous years, SGTech funded enhancements to the isotopics routine in the software called Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF), including the addition of peak fit customization capabilities. A project was also funded that focused on implementing a peak-based model fitting routine, allowing model fitting to be performed without dependence on export-controlled cross-sections. In FY25 significant improvements were made to the custom peak fitting interface, accompanied by several validation studies within GADRAS-DRF. These studies encompassed IsotopeID performance, distributed source analysis, isotopics validation, and activity estimation. Additionally, the peak-only model fitting option was validated using an HPGe measurement of a rotating drum with line sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved curve fits for the thermodynamic properties of equilibrium air suitable for numerical computation using time-dependent or shock-capturing methods, part 1

Simplified curve fits for the thermodynamic properties of equilibrium air were devised for use in either the time-dependent or shock-capturing computational methods. For the time-dependent method, curve fits were developed for p = p(e, rho), a = a(e, rho), and T = T(e, rho). For the shock-capturing method, curve fits were developed for h = h(p, rho) and T = T(p, rho). The ranges of validity for these curves fits were for temperatures up to 25,000 K and densities from 10 to the minus 7th power to 10 to the 3d power amagats. These approximate curve fits are considered particularly useful when employed on advanced computers such as the Burroughs ILLIAC 4 or the CDC STAR.

Tannehill, J. C.↗

Test fittings for dimensionally critical tubes

Method using lightweight fitting protects tubes and tube stubs during testing and through to final welding. Fitting does not interfere with final welding or brazing like temporary test fittings, and is not heavy like machined-on integral fittings with face-seal 0-rings. Fitting approach is adaptable to many types of components, including valves, transducers, and filters.

Hagler, R.↗

An interactive user-friendly approach to surface-fitting three-dimensional geometries

A surface-fitting technique has been developed which addresses two problems with existing geometry packages: computer storage requirements and the time required of the user for the initial setup of the geometry model. Coordinates of cross sections are fit using segments of general conic sections. The next step is to blend the cross-sectional curve-fits in the longitudinal direction using general conics to fit specific meridional half-planes. Provisions are made to allow the fitting of fuselages and wings so that entire wing-body combinations may be modeled. This report includes the development of the technique along with a User's Guide for the various menus within the program. Results for the modeling of the Space Shuttle and a proposed Aeroassist Flight Experiment geometry are presented.

Cheatwood, F. Mcneil↗

Simplified curve fits for the transport properties of equilibrium air

New, improved curve fits for the transport properties of equilibruim air have been developed. The curve fits are for viscosity and Prandtl number as functions of temperature and density, and viscosity and thermal conductivity as functions of internal energy and density. The curve fits were constructed using grabau-type transition functions to model the tranport properties of Peng and Pindroh. The resulting curve fits are sufficiently accurate and self-contained so that they can be readily incorporated into new or existing computational fluid dynamics codes. The range of validity of the new curve fits are temperatures up to 15,000 K densities from 10 to the -5 to 10 amagats (rho/rho sub o).

Srinivasan, S.↗

Comparison of aerobic fitness and space motion sickness during the Shuttle program

Space motion sickness (SMS) is an important problem for short-duration space flight; 71 percent of STS crewmembers develop SMS symptoms. The search for effective countermeasures and factors that correlate with sensitivity has been extensive. Recently, several investigators have linked aerobic fitness with motion sickness sensitivity in the 1-G or high-G environment. This paper compares the aerobic fitness of 125 Shuttle crewmembers with their SMS symptom category. Aerobic fitness data were obtained from the exercise tolerance test conducted nearest the time of launch. SMS data were derived from the medical debrief summaries. Mean maximum oxygen consumption values for crewmembers in four SMS categories (none, mild, moderate, severe) were 44.55, 44.08, 46.5, and 44.24 ml/kg per min, respectively. Scattergrams with linear regression analysis, comparing aerobic fitness and SMS symptom classification are presented. Correlation coefficients comparing SMS categories vs. aerobic fitness for men and women reveal no definite relationship between the two factors.

Jennings, Richard T.↗