Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SU-E-T-127: Application of TG-119 for Evaluation of Proton Spot Scanning Based Planning and Treatment Delivery

Purpose: The clinical test cases presented in AAPM TG-119 are used to evaluate the accuracy of treatment planning and delivery through spot scanning proton beams. Methods: An IBA spot scanning delivery system has been commissioned to be used with the RayStation treatment planning system. Various test cases provided in TG-119 were used for planning and delivery verification. The CT dataset and structures as provided by TG-119 were imported into a mock patient. The plans were optimized using the multi field optimization (MFO) to achieve the desired goals. The planner was given the flexibility to achieve the given dose-volume goals by creating appropriate objectives and constraints. Beams were delivered to a phantom and measurements were performed at multiple depths using the MatrixxPT detector array. The analyses were performed on beam by beam basis and quantified using the gamma index. A tolerance of 3%/3 mm in 2D was used for gamma index analysis along with dose threshold of 10%. Results: The clinical goals for targets and critical structures were met or improved for all cases except the C-Shape target with difficult constraints. The minimum gamma index using the 3%/3mm as a criterion is 93.3% for one of the planes measured for C-Shape target. Using 2%/2mm as a criterion, the minimum gamma index drops to 70%. Only Prostate target has all the planes above >90% pass using the 2%/2mm criterion. Conclusion: The overall accuracy of the treatment planning and delivery is deemed clinically acceptable. The test cases with highly modulated beams can have steep gradients in the dose profiles that can reduce the gamma index pass rate. Gamma analysis based on 3D data may be needed for routine use of 2%/2mm criterion. In addition, improvements in modelling of spot profiles in dose engine may be required for further improving the gamma index pass rate.

60 APPLIED LIFE SCIENCES↗

Minimum feature size control in level set topology optimization via density fields

A level set topology optimization approach that uses an auxiliary density field to nucleate holes during the optimization process and achieves minimum feature size control in optimized designs is explored. The level set field determines the solid-void interface and the density field describes the distribution of a fictitious porous material using the solid isotropic material with penalization. These fields are governed by two sets of independent optimization variables which are initially coupled using a penalty for hole nucleation. The strength of the density field penalization and projection is gradually increased during the optimization process to promote a 0-1 density distribution. In addition, a second penalty regulates the evolution of the density field in the void phase. The treatment of the density field combined with the second penalty mitigate the appearance of small design features. The minimum feature size of optimized designs is controlled by the radius of the linear filter applied to the density optimization variables. The structural response is predicted by the extended finite element method, the sensitivities by the adjoint method, and the optimization variables are updated by a gradient-based optimization algorithm. Numerical examples investigate the robustness of this approach with respect to algorithmic parameters and mesh refinement. The results show the applicability of the combined density level set topology optimization approach for both optimal hole nucleation and for minimum feature size control in 2D and 3D. This comes, however, at the cost of a more complex problem formulation and additional computational cost due to an increased number of optimization variables.

42 ENGINEERING↗

Efficient optimal reconstruction of linear fields and band-powers from cosmological data

We present an efficient implementation of Wiener filtering of real-space linear field and optimal quadratic estimator of its power spectrum Band-powers. We first recast the field reconstruction into an optimization problem, which we solve using quasi-Newton optimization. We then recast the power spectrum estimation into the field marginalization problem, from which we obtain an expression that depends on the field reconstruction solution and a determinant term. We develop a novel simulation based method for the latter. We extend the simulations formalism to provide the covariance matrix for the power spectrum. We develop a flexible framework that can be used on a variety of cosmological fields and present results for a variety of test cases, using simulated examples of projected density fields, projected shear maps from galaxy lensing, and observed Cosmic Microwave Background (CMB) temperature anisotropies, with a wide range of map incompleteness and variable noise. For smaller cases where direct numerical inversion is possible, we show that our solution matches that created by direct Wiener Filtering at a fraction of the overall computation cost. Even more significant reduction of computational is achieved by this implementation of optimal quadratic estimator due to the fast evaluation of the Hessian matrix. This technique allows for accurate map and power spectrum reconstruction with complex masks and nontrivial noise properties.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-214: Intensity Modulated Proton Therapy (IMPT) Based On Passively Scattered Protons and Multi-Leaf Collimation: Prototype TPS and Dosimetry Study

Purpose. Intensity-modulated proton therapy is usually implemented with multi-field optimization of pencil-beam scanning (PBS) proton fields. However, at the view of the experience with photon-IMRT, proton facilities equipped with double-scattering (DS) delivery and multi-leaf collimation (MLC) could produce highly conformal dose distributions (and possibly eliminate the need for patient-specific compensators) with a clever use of their MLC field shaping, provided that an optimal inverse TPS is developed. Methods. A prototype TPS was developed in MATLAB. The dose calculation process was based on a fluence-dose algorithm on an adaptive divergent grid. A database of dose kernels was precalculated in order to allow for fast variations of the field range and modulation during optimization. The inverse planning process was based on the adaptive simulated annealing approach, with direct aperture optimization of the MLC leaves. A dosimetry study was performed on a phantom formed by three concentrical semicylinders separated by 5 mm, of which the inner-most and outer-most were regarded as organs at risk (OARs), and the middle one as the PTV. We chose a concave target (which is not treatable with conventional DS fields) to show the potential of our technique. The optimizer was configured to minimize the mean dose to the OARs while keeping a good coverage of the target. Results. The plan produced by the prototype TPS achieved a conformity index of 1.34, with the mean doses to the OARs below 78% of the prescribed dose. This Result is hardly achievable with traditional conformal DS technique with compensators, and it compares to what can be obtained with PBS. Conclusion. It is certainly feasible to produce IMPT fields with MLC passive scattering fields. With a fully developed treatment planning system, the produced plans can be superior to traditional DS plans in terms of plan conformity and dose to organs at risk.

60 APPLIED LIFE SCIENCES↗

Comparison of organ-at-risk sparing and plan robustness for spot-scanning proton therapy and volumetric modulated arc photon therapy in head-and-neck cancer

Purpose: Proton radiotherapy for head-and-neck cancer (HNC) aims to improve organ-at-risk (OAR) sparing over photon radiotherapy. However, it may be less robust for setup and range uncertainties. The authors investigated OAR sparing and plan robustness for spot-scanning proton planning techniques and compared these with volumetric modulated arc therapy (VMAT) photon plans. Methods: Ten HNC patients were replanned using two arc VMAT (RapidArc) and spot-scanning proton techniques. OARs to be spared included the contra- and ipsilateral parotid and submandibular glands and individual swallowing muscles. Proton plans were made using Multifield Optimization (MFO, using three, five, and seven fields) and Single-field Optimization (SFO, using three fields). OAR sparing was evaluated using mean dose to composite salivary glands (Comp{sub Sal}) and composite swallowing muscles (Comp{sub Swal}). Plan robustness was determined for setup and range uncertainties (±3 mm for setup, ±3% HU) evaluating V95% and V107% for clinical target volumes. Results: Averaged over all patients Comp{sub Sal}/Comp{sub Swal} mean doses were lower for the three-field MFO plans (14.6/16.4 Gy) compared to the three-field SFO plans (20.0/23.7 Gy) and VMAT plans (23.0/25.3 Gy). Using more than three fields resulted in differences in OAR sparing of less than 1.5 Gy between plans. SFO plans were significantly more robust than MFO plans. VMAT plans were the most robust. Conclusions: MFO plans had improved OAR sparing but were less robust than SFO and VMAT plans, while SFO plans were more robust than MFO plans but resulted in less OAR sparing. Robustness of the MFO plans did not increase with more fields.

60 APPLIED LIFE SCIENCES↗

Efficient Optimization of Energy Recovery From Geothermal Reservoirs With Recurrent Neural Network Predictive Models

Improving the long-term energy production performance of geothermal reservoirs can be accomplished by optimizing field development and management plans. Reliable prediction models, however, are needed to evaluate and optimize the performance of the underlying reservoirs under various operation and development strategies. In traditional frameworks, physics-based simulation models are used to predict the energy production performance of geothermal reservoirs. However, detailed simulation models are not trivial to construct, require a reliable description of the reservoir conditions and properties, and entail high computational complexity. Data-driven predictive models can offer an efficient alternative for use in optimization workflows. This paper presents an optimization framework for net power generation in geothermal reservoirs using a variant of the recurrent neural network (RNN) as a data-driven predictive model. The RNN architecture is developed and trained to replace the simulation model for computationally efficient prediction of the objective function and its gradients with respect to the well control variables. The net power generation performance of the field is optimized by automatically adjusting the mass flow rate of production and injection wells over 12 years, using a gradient-based local search algorithm. Two field-scale examples are presented to investigate the performance of the developed data-driven prediction and optimization framework. Furthermore, the prediction and optimization results from the RNN model are evaluated through comparison with the results obtained by using a numerical simulation model of a real geothermal reservoir.

15 GEOTHERMAL ENERGY↗

An automated analysis workflow for optimization of force-field parameters using neutron scattering data

Graphical abstract: - Highlights: • An automated workflow to optimize force-field parameters. • Used the workflow to optimize force-field parameter for a system containing nanodiamond and tRNA. • The mechanism relies on molecular dynamics simulation and neutron scattering experimental data. • The workflow can be generalized to any other experimental and simulation techniques. - Abstract: Large-scale simulations and data analysis are often required to explain neutron scattering experiments to establish a connection between the fundamental physics at the nanoscale and data probed by neutrons. However, to perform simulations at experimental conditions it is critical to use correct force-field (FF) parameters which are unfortunately not available for most complex experimental systems. In this work, we have developed a workflow optimization technique to provide optimized FF parameters by comparing molecular dynamics (MD) to neutron scattering data. We describe the workflow in detail by using an example system consisting of tRNA and hydrophilic nanodiamonds in a deuterated water (D{sub 2}O) environment. Quasi-elastic neutron scattering (QENS) data show a faster motion of the tRNA in the presence of nanodiamond than without the ND. To compare the QENS and MD results quantitatively, a proper choice of FF parameters is necessary. We use an efficient workflow to optimize the FF parameters between the hydrophilic nanodiamond and water by comparing to the QENS data. Our results show that we can obtain accurate FF parameters by using this technique. The workflow can be generalized to other types of neutron data for FF optimization, such as vibrational spectroscopy and spin echo.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Clinical Outcomes and Patterns of Disease Recurrence After Intensity Modulated Proton Therapy for Oropharyngeal Squamous Carcinoma

Purpose: A single-institution prospective study was conducted to assess disease control and toxicity of proton therapy for patients with head and neck cancer. Methods and Materials: Disease control, toxicity, functional outcomes, and patterns of failure for the initial cohort of patients with oropharyngeal squamous carcinoma (OPC) treated with intensity modulated proton therapy (IMPT) were prospectively collected in 2 registry studies at a single institution. Locoregional failures were analyzed by using deformable image registration. Results: Fifty patients with OPC treated from March 3, 2011, to July 2014 formed the cohort. Eighty-four percent were male, 50% had never smoked, 98% had stage III/IV disease, 64% received concurrent therapy, and 35% received induction chemotherapy. Forty-four of 45 tumors (98%) tested for p16 were positive. All patients received IMPT (multifield optimization to n=46; single-field optimization to n=4). No Common Terminology Criteria for Adverse Events grade 4 or 5 toxicities were observed. The most common grade 3 toxicities were acute mucositis in 58% of patients and late dysphagia in 12%. Eleven patients had a gastrostomy (feeding) tube placed during therapy, but none had a feeding tube at last follow-up. At a median follow-up time of 29 months, 5 patients had disease recurrence: local in 1, local and regional in 1, regional in 2, and distant in 1. The 2-year actuarial overall and progression-free survival rates were 94.5% and 88.6%. Conclusions: The oncologic, toxicity, and functional outcomes after IMPT for OPC are encouraging and provide the basis for ongoing and future clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac

Purpose: Linac-magnetic resonance (MR) systems have been proposed in order to achieve real-time image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to achieve better quality images while reducing hot and cold spots in treatment planning. An investigation of linac's performance in the longitudinal fringe magnetic fields of the MR imager is given. Methods: The open MR imager fringe magnetic field was modeled using the analytic solution of the magnetic field generated from current carrying loops. The derived solution was matched to the magnetic fringe field isolines provided for a 0.5 T open MR imager through Monte Carlo optimization. The optimized field solution was then added to the previously validated 6 MV linac simulation to quantify linac's performance in the fringe magnetic field of a 0.5 T MR imager. To further the investigation, linac's performance in large fringe fields expected from other imagers was investigated through the addition of homogeneous longitudinal fields. Results: The Monte Carlo optimization of the analytic current loop solution provided good agreement with the magnetic fringe field isolines supplied by the manufacturer. The range of magnetic fields the linac is expected to experience when coupled to the 0.5 T MR imager was determined to be from 0.0022 to 0.011 T (as calculated at the electron gun cathode). The effect of the longitudinal magnetic field on the electron beam was observed to be only in the electron gun. The longitudinal field changed the electron gun optics, affecting beam characteristics, such as a slight increase in the injection current and beam diameter, and an increasingly nonlaminar transverse phase space. Although the target phase space showed little change in its energy spectrum from the altered injection phase space, a reduction in the target current and spatial distribution peak intensity was observed. Despite these changes, the target phase space had little effect on the depth dose curves or dose profiles calculated for a 40x40 cm{sup 2} field at 1.5 cm depth. At longitudinal fields larger than 0.012 T, a drastic reduction in the injection current from the electron gun was observed due to a large fraction of electrons striking the anode. This further reduced the target current, which reached a minimum of 28{+-}2 mA at 0.06 T. A slow increase in the injection and target currents was observed at fields larger than 0.06 T due to greater beam collimation in the anode beam tube. Conclusions: In an effort to achieve higher quality images and a reduction in hot and cold spots in the treatment plan, a parallel configuration linac-MR system is presented. The longitudinal magnetic fields of the MR imager caused large beam losses within the electron gun. These losses may be eliminated through a redesign of the electron gun optics incorporating a longitudinal magnetic field, or through magnetic shielding, which has already been proven successful for the transverse configuration.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-fidelity state transfer over an unmodulated linear XY spin chain

We provide a class of initial encodings that can be sent with a high fidelity over an unmodulated, linear, XY spin chain. As an example, an average fidelity of 96% can be obtained using an 11-spin encoding to transmit a state over a chain containing 10 000 spins. An analysis of the magnetic-field dependence is given, and conditions for field optimization are provided.

36 MATERIALS SCIENCE↗

MO-F-16A-05: Spot-Scanning Proton Therapy Patient-Specific Quality Assurance: Our Methodology and Results From 295 Treatment Plans

Purpose: To report on the patient-specific quality assurance (PSQA) results for 295 spot-scanning proton therapy treatment plans from the MD Anderson PTC-Houston. We show how the results differed by treatment site and how they were affected by the treatment plan optimization method and by a range shifter in the treatment field. We also discuss some causes of PSQA problems. Methods: The PSQA procedure, which is designed to verify both the accuracy of the treatment planning system's (Eclipse™ v8.9) dose calculations and the dose delivery of the Hitachi PROBEAT synchrotron, consists of (1) an end-to-end test in which the beam is delivered and measured at the prescribed gantry angle, and (2) additional dose plane measurements made from gantry angle 270°. HPlusQA™ software automatically performs the gamma analysis with criteria 3% (dose tolerance), 3 mm (distance-to-agreement, DTA) and 2%, 2 mm. Passing is defined as at least 90% of the pixels having a gamma score less than 1. Results: The PSQA gamma passing rate was 96.2% for 3%, 3 mm, and 85.3% for 2%, 2 mm. The rate depended on the treatment site. For example, the 3%, 3 mm passing rate was 95% for head and neck plans, vs 100% for prostate plans. The passing rates of multi- vs. single-field optimization plans did not significantly differ. However, the rate for fields with range shifters was 94.8±0.6%, vs 99.0±0.6% for those without (p = 0.002). Longitudinal dose gradients caused most of the low scores. Overestimation of the calculated dose proximal to the spread-out Bragg peak (SOBP) caused many of the others. Conclusion: The planned and delivered doses consistently agreed within tolerance levels. Minor dose modeling deficiencies remain proximal to the SOBP. The 3% dose tolerance, 3 mm DTA, with 90% pixel passing rate is a reasonable action level for 2D gamma comparisons.

60 APPLIED LIFE SCIENCES↗

Self-consistent mean-field quantum approximate optimization

We introduce a self-consistent mean-field quantum optimization algorithm that approximates the ground state of classical Ising Hamiltonians. The algorithm decomposes the problem into independent subproblems and treats the interactions between them in a mean-field manner. These interactions are captured by a common environment, constructed self-consistently through a variational quantum circuit, and which modifies the subproblems to account for mutual influence while maintaining computational independence. Consequently, subproblems can be solved individually, avoiding the computational cost of the full problem. We explore the properties of the generated environment and assess the algorithm's performance through extensive numerical simulations on Sherrington-Kirkpatrick spin glasses. Furthermore, we apply it experimentally to a weighted maximum clique problem applied to molecular docking. This framework enables the solution of problems that would otherwise exceed the qubit and gate counts of current quantum hardware.

Dupont, Maxime [Rigetti Computing] (ORCID:00000001↗

Self-consistent mean-field quantum approximate optimization

We introduce a self-consistent mean-field quantum optimization algorithm that approximates the ground state of classical Ising Hamiltonians. The algorithm decomposes the problem into independent subproblems and treats the interactions between them in a mean-field manner. These interactions are captured by a common environment, constructed self-consistently through a variational quantum circuit, and which modifies the subproblems to account for mutual influence while maintaining computational independence. Consequently, subproblems can be solved individually, avoiding the computational cost of the full problem. We explore the properties of the generated environment and assess the algorithm's performance through extensive numerical simulations on Sherrington-Kirkpatrick spin glasses. Furthermore, we apply it experimentally to a weighted maximum clique problem applied to molecular docking. This framework enables the solution of problems that would otherwise exceed the qubit and gate counts of current quantum hardware.

Dupont, Maxime [Rigetti Computing] (ORCID:00000001↗

Self-consistent mean-field quantum approximate optimization

We introduce a self-consistent mean-field quantum optimization algorithm that approximates the ground state of classical Ising Hamiltonians. The algorithm decomposes the problem into independent subproblems and treats the interactions between them in a mean-field manner. These interactions are captured by a common environment, constructed self-consistently through a variational quantum circuit, and which modifies the subproblems to account for mutual influence while maintaining computational independence. Consequently, subproblems can be solved individually, avoiding the computational cost of the full problem. We explore the properties of the generated environment and assess the algorithm's performance through extensive numerical simulations on Sherrington-Kirkpatrick spin glasses. Furthermore, we apply it experimentally to a weighted maximum clique problem applied to molecular docking. This framework enables the solution of problems that would otherwise exceed the qubit and gate counts of current quantum hardware.

Dupont, Maxime [Rigetti Computing] (ORCID:00000001↗

Joint Estimation of Cardiac Toxicity and Recurrence Risks After Comprehensive Nodal Photon Versus Proton Therapy for Breast Cancer

Purpose: The study aims to perform joint estimation of the risk of recurrence caused by inadequate radiation dose coverage of lymph node targets and the risk of cardiac toxicity caused by radiation exposure to the heart. Delivered photon plans are compared with realistic proton plans, thereby providing evidence-based estimates of the heterogeneity of treatment effects in consecutive cases for the 2 radiation treatment modalities. Methods and Materials: Forty-one patients referred for postlumpectomy comprehensive nodal photon irradiation for left-sided breast cancer were included. Comparative proton plans were optimized by a spot scanning technique with single-field optimization from 2 en face beams. Cardiotoxicity risk was estimated with the model of Darby et al, and risk of recurrence following a compromise of lymph node coverage was estimated by a linear dose-response model fitted to the recurrence data from the recently published EORTC (European Organisation for Research and Treatment of Cancer) 22922/10925 and NCIC-CTG (National Cancer Institute of Canada Clinical Trials Group) MA.20 randomized controlled trials. Results: Excess absolute risk of cardiac morbidity was small with photon therapy at an attained age of 80 years, with median values of 1.0% (range, 0.2%-2.9%) and 0.5% (range, 0.03%-1.0%) with and without cardiac risk factors, respectively, but even lower with proton therapy (0.13% [range, 0.02%-0.5%] and 0.06% [range, 0.004%-0.3%], respectively). The median estimated excess absolute risk of breast cancer recurrence after 10 years was 0.10% (range, 0.0%-0.9%) with photons and 0.02% (range, 0.0%-0.07%) with protons. The association between age of the patient and benefit from proton therapy was weak, almost non-existing (Spearman rank correlations of −0.15 and −0.30 with and without cardiac risk factors, respectively). Conclusions: Modern photon therapy yields limited risk of cardiac toxicity in most patients, but proton therapy can reduce the predicted risk of cardiac toxicity by up to 2.9% and the risk of breast cancer recurrence by 0.9% in individual patients. Predicted benefit correlates weakly with age. Combined assessment of the risk from cardiac exposure and inadequate target coverage is desirable for rational consideration of competing photon and proton therapy plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗