Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fibrils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A contribution with review to the description of mineralization of bone and other calcified tissues in vivo

This manuscript considers certain aspects of mineral deposition in bone and other vertebrate calcifying tissues in order to examine physical, chemical, and biological factors important in the mineralization process. The paper in a discussion format principally presents a new data and the formulation of concepts based on such data as well as a summary of background material as necessary review. Mineralization is found to occur at spatially independent sites throughout the organic extracellular tissue matrices. Matrix vesicles and collagen fibrils each may serve as independent nucleation centers for mineral with vesicle mineralization being local and collagen mineralization dominating the tissues as a whole. Collagen fibril organization is suggested to be such that hole zones are aligned in three dimensions, creating extensive channels for mineral accommodation. Nucleation occurs initially in hole zones and crystal growth leads to the development of plate-like mineral particles whose orientation, disposition, and sizes within fibrils are detailed. Effects of diffusion, crystallinity, and critical nucleation and growth events are described with respect to their influence on mineral deposition in bulk and local regions of tissue matrices.

Review↗

Effect of varying ventricular function by extrasystolic potentiation on closure of the mitral valve.

Mitral regurgitant indexes were measured by roentgen videodensitometry in anesthetized dogs without thoracotomy before, during and after extrasystolic potentiation of ventricular contraction while the atria and ventricles were driven in normal temporal sequence simultaneously or in such a way as to induce atrial fibrillation. Small amounts of mitral reflux were observed with simultaneous atrial and ventricular driving and with atrial fibrillation in the control measurements before initiation of extrasystolic potentiation. Reflux became negligible during extrasystolic potentiation and increased beyond control levels after termination of extrasystolic potentiation.

Vandenberg, R. A.↗

Measurement and analysis of magnetic field variation during a class 2b flare

A digital analysis of high-time-resolution videomagnetograms taken during a class 2b flare that occurred at 60 deg east is reported. The data were obtained at the Big Bear Observatory and calibrated by a Mt. Wilson magnetogram. Changes of weak magnetic fields (less than 100 G) with an amplitude of 30% to 100% have been detected over 55% of the optical flare region, apparently taking place at the initial phase of the flare. Statistical considerations suggest a real flare association with most of these changes. H-alpha observations show that large changes took place over the footpoints of heavily inclined structures like penumbral fibrils, while smaller changes took place over the plage region. An apparent polarity reversal was found at the feet of erupted fibrils. Based on force-free field calculations these changes can be reasonably explained as a transformation of the current-carrying fields to potential fields which produced large changes in the field-line inclination and rotation.

Tanaka, K.↗

Initial dynamics of the EKG during an electrical defibrillation of the heart

In tests on 11 mature dogs, immobilized by means of an automatic blocking and synchronization system, artefact free EKG were obtained, beginning 0.04-0.06 sec after passage of a defibrillating current. Different versions of the start of fibrillation were noted, in application of the defibrillating stimulus in the early phase of the cardiac cycle. A swinging phenomenon, increasing amplitude, of fibrillation was noted for 0.4-1.5 sec after delivery of a subthreshold stimulus. Conditions for a positive outcome of repeated defibrillation were found, and a relationship was noted between the configuration of the exciting process with respect to the lines of force of the defibrillating current and the defibrillation threshold. It was shown that the initial EKG dynamics after defibrillation is based on a gradual shift of the pacemaker from the myocardium of the ventricles to the sinus node, through phases of atrioventricular and atrial automatism.

Bikov, I. I.↗

Evaluation of micron size carbon fibers released from burning graphite composites

Quantitative estimates were developed of micron carbon fibers released during the burning of graphite composites. Evidence was found of fibrillated particles which were the predominant source of the micron fiber data obtained from large pool fire tests. The fibrillation phenomena were attributed to fiber oxidation effects caused by the fire environment. Analysis of propane burn test records indicated that wind sources can cause considerable carbon fiber oxidation. Criteria estimates were determined for the number of micron carbon fibers released during an aircraft accident. An extreme case analysis indicated that the upper limit of the micron carbon fiber concentration level was only about half the permissible asbestos ceiling concentration level.

Sussholz, B.↗

Fracto-emission from single fibres of Kevlar

Fracto-emission (FE) is the emission of particles (e.g. electrons, ions and photons) during and following fracture. In this paper, we present data on electron emission (EE) and positive ion emission (PIE) from the tensile fracture of Kevlar single fibers. The fibers were initially fractured in pure tension, where a stranded form of fracture was observed, often with multiple peaks spread over several hundred microseconds. The loading condition was then changed by stretching and breaking the fibers over a dull metal edge. With this change in the loading, different forms of fracture were observed, each with distinctive forms of emission curves. When fracture was accompanied by extensive fibril formation, total emission was high and both EE and PIE decay times were long relative to fractures in which little fibril formation occurred. The results of this study suggest that FE has some applicability as a tool for the detection of fracture mechanisms of single fibers.

Dickinson, J. T.↗

A hillock and cloud model for faculae

A hillock model is used here to explain facular contrasts, allowing faculae to emit more energy than the surrounding unmagnetized photosphere. For downflows, horizontal motions converge near the photosphere and many fibril flux tubes are drawn together to form a large dark area, the sunspot. For upflows, the motions diverge near the photosphere and fibril flux tubes are dispersed over a larger area associated with faculae. The upflows transport material and energy, resulting in hotter than normal temperatures, which in turn cause the gas to expand compared with its surroundings. Buoyancy thus causes a 'network' of patchy hillocks, clouds, or geysers to form which allows the sun to reradiate the energy deficit associated with sunspots by locally increasing the effective surface area of the sun beyond that of a sphere. The consequences of this model for the physical form of the facular manifestation, the appearance of faculae from earth, and the 'energy balance' in active regions are addressed.

Schatten, Kenneth H.↗

A nonlinear analysis of an equilibrium craze. I - Problem formulation and solution. II - Simulations of craze and crack growth

A numerical method is developed for the determinations of the equilibrium shape of a craze in an infinite elastic plane whose fibrils exhibit very general nonlinear force-displacement behavior. The problem formulation is based on the superposition of the relevant elasticity Green's function; the solution of the resulting nonlinear problem is obtained by using Picard's successive approximation scheme. The model is used to investigate the effect of nonlinear fibril behavior on the mechanics of craze and crack growth, and the results are compared with the Dugdale model.

Ungsuwarungsri, T.↗

Nonlinear dynamics, fractals, cardiac physiology and sudden death

The authors propose a diametrically opposite viewpoint to the generally accepted tendency of equating healthy function with order and disease with chaos. With regard to the question of sudden cardiac death and chaos, it is suggested that certain features of dynamical chaos related to fractal structure and fractal dynamics may be important organizing principles in normal physiology and that certain pathologies, including ventricular fibrillation, represent a class of 'pathological periodicities'. Some laboratory work bearing on the relation of nonlinear analysis to physiological and pathophysiological data is briefly reviewed, with tentative theories and models described in reference to the mechanism of ventricular fibrillation.

Goldberger, Ary L.↗

The Extensional Rheology of Non-Newtonian Materials

The evolution of the transient extensional stresses in dilute and semi-dilute viscoelastic polymer solutions are measured with a filament stretching rheometer of a design similar to that first introduced by Sridhar, et al. The solutions are polystyrene-based (PS) Boger fluids that are stretched at constant strain rates ranging from 0.6 less than or equal to epsilon(0) less than or equal to 4s(exp -1) and to Hencky strains of epsilon greater than 4. The test fluids all strain harden and Trouton ratios exceeding 1000 are obtained at high strains. The experimental data strain hardens at lower strain levels than predicted by bead-spring FENE models. In addition to measuring the transient tensile stress growth, we also monitor the decay of the tensile viscoelastic stress difference in the fluid column following cessation of uniaxial elongation as a function of the total imposed Hencky strain and the strain rate. The extensional stresses initially decay very rapidly upon cessation of uniaxial elongation followed by a slower viscoelastic relaxation, and deviate significantly from FENE relaxation predictions. The relaxation at long times t is greater than or equal to 5 s, is compromised by gravitational draining leading to non-uniform filament profiles. For the most elastic fluids, partial decohension of the fluid filament from the endplates of the rheometer is observed in tests conducted at high strain rates. This elastic instability is initiated near the rigid endplate fixtures of the device and it results in the progressive breakup of the fluid column into individual threads or 'fibrils' with a regular azimuthal spacing. These fibrils elongate and bifurcate as the fluid sample is elongated further. Flow visualization experiments using a modified stretching device show that the instability develops as a consequence of an axisymmetry-breaking meniscus instability in the nonhomogeneous region of highly deformed fluid near the rigid endplate.

Spiegelberg, Stephen H.↗

Collagen Gel Contraction by Fibroblasts: The Role of Myosin 2 and Gravity Effects

Several lines of evidence suggest that collagen organization by connective tissue cells is sensitive to force. For instance, in flight experiments on rats the collagen fibrils which were produced under weightlessness and which were immediately next to the tendon fibroblasts were shown to be oriented randomly around the cells while the older fibrils right next to these and which were produced under 1 G, were highly organized.

Johnson-Wint, Barbara P.↗

Implantable Heart Aid

Medrad utilized NASA's Apollo technology to develop a new device called the AID implantable automatic pulse generator which monitors the heart continuously, recognizes the onset of ventricular fibrillation and delivers a corrective electrical shock. AID pulse generator is, in effect, a miniaturized version of the defibrillator used by emergency squads and hospitals to restore rhythmic heartbeat after fibrillation, but has the unique advantage of being permanently available to the patient at risk. Once implanted, it needs no specially trained personnel or additional equipment. AID system consists of a microcomputer, a power source and two electrodes which sense heart activity.

Source record↗

Space Derived Health Aids (AID, Heart Monitor)

CPI's spinoff from miniaturized pace circuitry is the new heart-assist device, the AID implantable automatic pulse generator. AID pulse generator monitors the heart continuously, recognizes onset of fibrillation, then administers a corrective electrical shock. A mini- computer, a power source, and two electrodes which sense heart activity are included in the unit. An associated system was also developed. It includes an external recorder to be worn by AID patients and a physician's console to display the data stored by the recorder. System provides a record of fibrillation occurrences and the ensuing defibrillation.

Source record↗

Asymmetric Stokes-V Profiles at the Penumbral Boundary of a Sunspot

We present the spectropolarimetric measurements of a sunspot in the active region NOAA 6958 (15S03W), situated near the central meridian disk passage. The follower polarity sunspot was somewhat symmetrically round shaped with an elongated penumbra. There were several opposite polarity magnetic elements at, and beyond the penumbral boundary. The H-alpha images of the sunspot show the bright emission regions near the penumbral boundary towards the sun-center, which was of opposite polarity with respect to the main spot. The net-circular polarization (NCP) map shows that NCP is negative in the inner part of the spot and positive at the penumbral boundary and near the H-alpha plage. The Doppler velocities were determined by measuring the center-of-gravity (COG) of the Stokes-I profile and zero-crossing (ZC) wavelength of the Stokes-V profiles. The COG velocity map in general agrees with the Evershed flow. In addition, it shows the up flow in the penumbral region. The ZC velocities show the strong down flow at the penumbral boundary. Double-lobed Stokes-V profiles are observed at the locations, where the penumbral fibrils terminate coinciding the H-alpha plage. The Double lobed profiles had an unshifted component similar to the Stokes-V profiles of the sunspot penumbra and a shifted component with a velocity of about 5 km/s. The amplitude of the second component increases along the penumbral fibril as a function of the distance from the center of the sunspot. In this paper we discuss the role of emerging flux in generating the observed double lobed profiles. Based on our present observations, we propose to observe with the Solar-B Spectropolarimeter for understanding the nature of emerging flux near the sunspots.

Choudhary, Debi Prasad↗

Quantitative determination of the mineral distribution in different collagen zones of calcifying tendon using high voltage electron microscopic tomography

High voltage electron microscopic tomography was used to make the first quantitative determination of the distribution of mineral between different regions of collagen fibrils undergoing early calcification in normal leg tendons of the domestic turkey, Meleagris gallopavo. The tomographic 3-D reconstruction was computed from a tilt series of 61 different views spanning an angular range of +/- 60 degrees in 2 degrees intervals. Successive applications of an interactive computer operation were used to mask the collagen banding pattern of either hole or overlap zones into separate versions of the reconstruction. In such 3-D volumes, regions specified by the mask retained their original image density while the remaining volume was set to background levels. This approach was also applied to the mineral crystals present in the same volumes to yield versions of the 3-D reconstructions that were masked for both the crystal mass and the respective collagen zones. Density profiles from these volumes contained a distinct peak corresponding only to the crystal mass. A comparison of the integrated density of this peak from each profile established that 64% of the crystals observed were located in the collagen hole zones and 36% were found in the overlap zones. If no changes in crystal stability occur once crystals are formed, this result suggests the possibilities that nucleation of mineral is preferentially and initially associated with the hole zones, nucleation occurs more frequently in the hole zones, the rate of crystal growth is more rapid in the hole zones, or a combination of these alternatives. All lead to the conclusion that the overall accumulation of mineral mass is predominant in the collagen hole zones compared to overlap zones during early collagen fibril calcification.

NASA Program Space Biology↗

Mineral and organic matrix interaction in normally calcifying tendon visualized in three dimensions by high-voltage electron microscopic tomography and graphic image reconstruction

To define the ultrastructural accommodation of mineral crystals by collagen fibrils and other organic matrix components during vertebrate calcification, electron microscopic 3-D reconstructions were generated from the normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo. Embedded specimens containing initial collagen mineralizing sites were cut into 0.5-micron-thick sections and viewed and photographed at 1.0 MV in the Albany AEI-EM7 high-voltage electron microscope. Tomographic 3-D reconstructions were computed from a 2 degree tilt series of micrographs taken over a minimum angular range of +/- 60 degrees. Reconstructions of longitudinal tendon profiles confirm the presence of irregularly shaped mineral platelets, whose crystallographic c-axes are oriented generally parallel to one another and directed along the collagen long axes. The reconstructions also corroborate observations of a variable crystal length (up to 170 nm measured along crystallographic c-axes), the presence of crystals initially in either the hole or overlap zones of collagen, and crystal growth in the c-axis direction beyond these zones into adjacent overlap and other hole regions. Tomography shows for the first time that crystal width varies (30-45 nm) but crystal thickness is uniform (approximately 4-6 nm at the resolution limit of tomography); more crystals are located in the collagen hole zones than in the overlap regions at the earliest stages of tendon mineralization; the crystallographic c-axes of the platelets lie within +/- 15-20 degrees of one another rather than being perfectly parallel; adjacent platelets are spatially separated by a minimum of 4.2 +/- 1.0 nm; crystals apparently fuse in coplanar alignment to form larger platelets; development of crystals in width occurs to dimensions beyond single collagen hole zones; and a thin envelope of organic origin may be present along or just beneath the surfaces of individual mineral platelets. Implicit in the results is that the formation of crystals occurs at different sites and times by independent nucleation events in local regions of collagen. These data provide the first direct visual evidence from 3-D imaging describing the size, shape, orientation, and growth of mineral crystals in association with collagen of a normally mineralizing vertebrate tissue. They support concepts that c-axial crystal growth is unhindered by collage hole zone dimensions, that crystals are organized in the tendon in a series of generally parallel platelets, and that crystal growth in width across collagen fibrils may follow channels or grooves formed by adjacent hole zones in register.

Non-NASA Center↗

Parabolic Flights in Support of the Ring-Sheared Drop (RSD) Module Aboard the ISS

The Ring-Sheared Drop module was conceived as a centimeter-scale, containerless biochemical reactor to study shearing flow at gas-liquid interfaces without complications associated with solid walls. The drop is constrained by a thin, stationary contact ring in one hemisphere and sheared by the steady rotation of another ring in the other hemisphere. The original experiment considers a 2.5 cm diameter drop of human insulin solution in order to examine the formation of amyloid fibrils without wall nucleation. Shear-induced amyloidogenesis is of wide interest due to the pathogenic role amyloid proteins play in diseases such as Alzheimer's, Parkinson's, prion diseases, and type-2 diabetes. Pinning full-scale drops of native protein solutions - prior to any fibrillization - was challenging and required a collaborative effort. In this talk we report on laboratory experiments, multiphase CFD simulations, and several parabolic flights to find strategies that are effective for constraining large drops of protein in microgravity.

Amir Hirsa↗

Subtle alternating electrocardiographic morphology as an indicator of decreased cardiac electrical stability

Observations from finite-element computer models, together with analytic developments based on percolation theory have suggested that subtle fluctuations of ECG morphology might serve as an indicator diminished cardiac electrical stability. With fixed-rate atrial pacing in canines, we have previously observed a pattern of alternation in T wave energy which correlated with cardiac electrical stability. We report here on a series of 20 canine experiments in which cardiac electrical stability (measured via Ventricular Fibrillation Threshold determination) was compared to a non-degenerate, multidimensional measurement of the degree of alternating activity present in the ECG complex morphology. The decrease in cardiac electrical stability brought on by both coronary artery occlusion and systemic hypothermia was consistently accompanied by subtle alternation in ECG morphology, with the absolute degree of alternating activity being significantly (negatively) correlated with cardiac electrical stability.

Ventricular Fibrillation↗