Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cubic-meter scale laboratory fault re-activation experiments to improve the understanding of induced seismicity risks

Abstract To understand fluid induced seismicity, we have designed a large-scale laboratory experiment consisting of a one-cubic-meter sandstone with an artificial fault cut and fluid-injection boreholes. The sandstone block is assembled in a true triaxial loading frame and equipped with 38 piezoelectric sensors to locate and characterise acoustic emission events. The differential stress on the artificial fault is increased in stages to bring it towards a critically stressed state. After each stage of differential stress increase, fluids are injected at low pressures through boreholes to test the potential of fault re-activation. In addition, a high-pressure injection was conducted that created a hydraulic fracture from the injection borehole towards the artificial fault. The newly generated fluid pathway resulted in an activation of the complete block through a stick–slip movement. We compare acoustic emission measurements from the laboratory experiment with seismicity observations from the field-scale CO 2 injection at Decatur, Illinois, U.S., and conclude that the existence of fluid pathways plays a decisive role for the potential of induced seismicity.

47 OTHER INSTRUMENTATION↗

Transient Stability Study of IEEE 2800-2022 Standard Negative-Sequence-Current Compliant GFM IBRs

The primary function of grid-forming (GFM) inverter-based resources (IBRs) is to maintain voltage and fre- quency/phase angle stability; however, during unbalanced grid faults, IEEE Std. 2800-2022 requires IBRs to inject both positive- and negative-sequence reactive current. Enforcing compliance with this standard could compromise the stability of GFM IBRs under such fault conditions. This paper presents a preliminary transient stability study focused on the power angle stability of GFM IBRs operating in compliance with IEEE Std. 2800 during unbalanced faults. The goal is to assess potential stability issues associated with the standard's current injection requirements under fault ride-through conditions. The results show that injecting positive-sequence current with d-axis priority during unbalanced faults better preserves the power angle stability than the q-axis priority while still enabling negative-sequence current injection. These findings suggest that, to ensure stability, GFM IBRs might need to partially comply with IEEE Std. 2800 by prioritizing positive-sequence current injection along the d-axis.

14 SOLAR ENERGY↗

Analysis of Microseismicity and Reactivated Fault Size to Assess the Potential for Felt Events by CO 2 Injection in the Illinois Basin

The results of monitoring of carbon dioxide (CO 2 ) injection at the Illinois Basin—Decatur Project (IBDP) and the companion Illinois Industrial Carbon Capture and Sequestration Sources (IL-ICCS) project—have shown that reservoir response to fluid pressure changes can vary significantly at different injection locations within the same reservoir. Predrill reservoir characterization is important to identify potentially seismogenic faults. However, interpretations of newly reprocessed 3D seismic reflection data illustrate the challenges related to their identification in a region dominated by faulting with small vertical offsets. Faults interpreted in the 3D seismic volume range from ~300 to 1200 m wide and are in the same size range as faults that could have been the source of historical events up to Mw 2.7 in central Illinois. The array of monitoring sensors that was installed for the IBDP continues to collect data, as injection operates in IL-ICCS, the second injection well. CO 2 injection rates for the IL-ICCS well are on average 1.7 times the rates injected in the IBDP well, but a significantly reduced rate of induced seismicity is observed. This article presents results of passive seismic monitoring for the duration of the project to date, integrating active and passive seismic data to develop a new interpretation of the subsurface structure at the Decatur site that explicitly identifies pathways for fluid flow into the basement leading to induced seismicity, and provides a geological explanation for the sharp reduction of induced seismicity during injection at higher rates into the second well. The use of seismic moment to estimate the length of seismogenic slip planes in the local subsurface suggests that faults large enough to produce felt seismicity are unlikely to be present at or near the Decatur site.

Geochemistry & Geophysics↗

Phase II Field Demonstration at Lansing Smith Generating Plant, Southport, Florida (Final Report)

The Final Technical Report: Field Test Design and Pressure Management Strategies for Phase II Field Demonstration of Optimal Pressure Control, Plume Management, and Produced Water Strategies presents the culmination of multi-year efforts under the U.S. Department of Energy’s Brine Extraction and Storage Test (BEST) program, led by EPRI in partnership with Gulf Power at the Plant Smith site near Panama City, Florida. The project was designed to evaluate and demonstrate the technical feasibility of managing subsurface pressures and fluid movement associated with large-scale CO₂ injection, using low-salinity water as a proxy fluid. Through a combination of field injection testing, reservoir modeling, and optimization studies, the research team developed and refined active and passive brine extraction strategies aimed at controlling injection-induced pressure buildup, mitigating risks of fault activation, and managing plume migration. The field demonstration incorporated a new injection well (TIW-2), a new monitoring/extraction well (TEMW-A), and an existing well (TIW-1) repurposed for passive pressure relief. Complementary geophysical monitoring was designed to track plume development and evaluate the effectiveness of pressure management strategies. The report details the integrated workflow encompassing wellfield development, regulatory permitting, model calibration, and survey design. It includes a comprehensive electromagnetic (EM) modeling and inversion study used to develop a cost-effective, time-lapse geophysical monitoring plan capable of imaging the evolving low-salinity plume within the highly saline Lower Tuscaloosa formation. Reservoir simulation results guided the design of the 17-month injection program and the timing of active extraction to maintain formation pressures below a hypothetical fault reactivation threshold. Supporting analyses evaluated potential injectivity risks related to clay fines migration and geochemical incompatibility, identifying practical mitigation measures such as salinity and pH control. The final design recommends a series of crosswell EM surveys—conducted before, during, and after injection—as the most effective and economical approach for plume imaging, supplemented by continuous downhole pressure and flow monitoring. Collectively, the study provides a field-ready framework for cost-effective pressure management and monitoring in support of future CO₂ storage projects.

01 COAL, LIGNITE, AND PEAT↗

Unsupervised Clustering of Microseismic Events and Focal Mechanism Analysis at the CO 2 Injection Site in Decatur, Illinois

Characterization of induced microseismicity at a carbon dioxide (CO 2 ) storage site is critical for preserving reservoir integrity and mitigating seismic hazards. We apply a multilevel machine learning (ML) approach that combines the nonnegative matrix factorization and hidden Markov model to extract spectral representations of microseismic events and cluster them to identify seismic patterns at the Illinois Basin-Decatur Project. Unlike traditional waveform correlation methods, this approach leverages spectral characteristics of first arrivals to improve event classification and detect previously undetected planes of weakness. By integrating ML-based clustering with focal mechanism analysis, we resolve small-scale fault structures that are below the detection limits of conventional seismic imaging. Our findings reveal temporal bursts of microseismicity associated with brittle failure, providing insights into the spatio-temporal evolution of fault reactivation during CO 2 injection. This approach enhances seismic monitoring capabilities at CO 2 injection sites by improving fault characterization beyond the resolution of standard geophysical surveys.

Willis, Rachel Marie [Sandia National Laboratories↗

Transient evolution of permeability and friction in a slowly slipping fault activated by fluid pressurization

The mechanisms of permeability and friction evolution in a natural fault are investigated in situ. During three fluid injection experiments at different places in a fault zone, we measured simultaneously the fluid pressure, fault displacements and seismic activity. Changes in fault permeability and friction are then estimated concurrently. Results show that fault permeability increases up to 1.58 order of magnitude as a result of reducing effective normal stress and cumulative dilatant slip, and 19-to-60.8% of the enhancement occurs without seismic emissions. When modeling the fault displacement, we found that a rate-and-state friction and a permeability dependent on both slip and slip velocity together reasonably fit the fault-parallel and fault-normal displacements. This leads to the conclusion that the transient evolution of fault permeability and friction caused by a pressure perturbation exerts a potentially dominant control on fault stability during fluid flow.

58 GEOSCIENCES↗

Mechanisms for Microseismicity Occurrence Due to CO 2 Injection at Decatur, Illinois: A Coupled Multiphase Flow and Geomechanics Perspective

Here, we numerically investigate the mechanisms that resulted in induced seismicity occurrence associated with CO 2 injection at the Illinois Basin–Decatur Project (IBDP). We build a geologically consistent model that honors key stratigraphic horizons and 3D fault surfaces interpreted using surface seismic data and microseismicity locations. We populate our model with reservoir and geomechanical properties estimated using well-log and core data. We then performed coupled multiphase flow and geomechanics modeling to investigate the impact of CO 2 injection on fault stability using the Coulomb failure criteria. We calibrate our flow model using measured reservoir pressure during the CO 2 injection phase. Our model results show that pore-pressure diffusion along faults connecting the injection interval to the basement is essential to explain the destabilization of the regions where microseismicity occurred, and that poroelastic stresses alone would result in stabilization of those regions. Slip tendency analysis indicates that, due to their orientations with respect to the maximum horizontal stress direction, the faults where the microseismicity occurred were very close to failure prior to injection. These model results highlight the importance of accurate subsurface fault characterization for CO 2 sequestration operations.

58 GEOSCIENCES↗

Hydromechanical Modeling of Fault Rupture in Geologic CO 2 Sequestration: A Comparison of Two Failure Criteria

Abstract The large‐scale implementation of geological carbon sequestration has raised concerns about potential fault activation and induced seismicity, which could compromise storage integrity and pose seismic risks. We theoretically compared two failure criteria, Mohr‐Coulomb (MC) and Modified Cam‐Clay criteria (MCC), to assess fault rupture during CO 2 storage. Both criteria characterize fault behavior in a specific stress regime but differ in reducing the complexity of fault rupture to a few key mechanisms. Using a coupled hydromechanical model, we demonstrate that the choice of a failure criterion and the physics of fault weakening associated with these criteria strongly condition fault response to a given fluid injection. MC mainly relates rupture to friction, while MCC relates rupture to fault poro‐plasticity. Our findings highlight that the selection of a failure criterion, being inherently subjective, can significantly alter the predicted fault behavior during CO 2 storage, thereby impacting the reliability of geomechanical risk assessments.

Cao, M. [Energy Geosciences Division Lawrence Berk↗

Hydrogeologic Model Based on Reduced Complexity

This data set provides the basic hydrogeologic model used for development of the TOUGH2 reservoir modeling results for the Kimberlina site. The hydrogeologic model is based on the static geologic model provided as a separate data set but has some simplifications regarding the geologic layers. Some geologic layers have been merged for the hydrogeologic model because the hydrogeologic properties were very similar. The data set contains several files. The word file explains the structure of the data files. The pdf contains a table with the hydrogeologic properties. The data set also includes 15 thickness files for 15 geological layers (including 3 Vedder sand layers and 3 Vedder shale layers), three elevations files (with reference elevation at ground surface/model top at 9000 m), and one fault trace file for seven faults. Most users may only need 2-3 faults close to the injection well (also see the figure). The arrangement of these layer thickness and elevations files can be see from the three layer files (for Tecplot). To develop a grid structure, start with the Vedder top elevation (REFVedderTop.dat) and add/subtract the thicknesses of layers above/below.

3D Groundwater Model↗

Coupled Hydromechanical Modeling of Induced Seismicity From CO 2 Injection in the Illinois Basin

Injection of CO 2 for geologic carbon sequestration into deep sedimentary formations involves fluid pressure increases that engage hydromechanical processes that can cause seismicity by activation of existing faults. In this work, we use a coupled multiphase fluid flow and geomechanical simulator to model spatiotemporal fluid pressure and stress changes in order to study the poroelastic effect of CO 2 injection on faults in crystalline basement rock below the injection zone. The seismicity rate along features interpreted to be basement faults is modeled using Dieterich's rate-and-state earthquake nucleation model. The methodology is applied to microseismicity detected during CO 2 injection into the Mount Simon formation during the Illinois Basin—Decatur Project. The modeling accurately captures an observed reduction in seismicity rate when the injection in the second well was into a slightly shallower zone above the base of the Mount Simon formation. Moreover, the modeling shows that it is important to consider poroelastic stress changes, in addition to fluid pressure changes for accurately modeling of the observed seismicity rate.

58 GEOSCIENCES↗

Permeability-controlled migration of induced seismicity to deeper depths near Venus in North Texas

Abstract Migration of seismic events to deeper depths along basement faults over time has been observed in the wastewater injection sites, which can be correlated spatially and temporally to the propagation or retardation of pressure fronts and corresponding poroelastic response to given operation history. The seismicity rate model has been suggested as a physical indicator for the potential of earthquake nucleation along faults by quantifying poroelastic response to multiple well operations. Our field-scale model indicates that migrating patterns of 2015–2018 seismicity observed near Venus, TX are likely attributed to spatio-temporal evolution of Coulomb stressing rate constrained by the fault permeability. Even after reducing injection volumes since 2015, pore pressure continues to diffuse and steady transfer of elastic energy to the deep fault zone increases stressing rate consistently that can induce more frequent earthquakes at large distance scales. Sensitivity tests with variation in fault permeability show that (1) slow diffusion along a low-permeability fault limits earthquake nucleation near the injection interval or (2) rapid relaxation of pressure buildup within a high-permeability fault, caused by reducing injection volumes, may mitigate the seismic potential promptly.

58 GEOSCIENCES↗

Impact of Inverter-Based Resources on Grid Protection: A Review of Negative-Sequence Current Generation

The increasing integration of inverter-based resources (IBRs) in power grids poses challenges to traditional protection systems, primarily due to their different fault current signatures compared to conventional synchronous generators. Unlike synchronous generators whose fault response is dictated by their physical design, IBRs exhibit a wide range of fault characteristics due to manufacturer-specific control algorithms and settings. This dependence on proprietary control schemes makes modeling IBR behavior during faults significantly more complex, especially considering the rapid evolution of inverter technology and the diverse control strategies employed. While much research has focused on the positive-sequence current injections of IBRs during symmetrical faults, the understanding of negative-sequence current generation during non-symmetrical faults remains limited. This report provides an overview of current research on IBRs' negative-sequence current generation during unbalanced faults and its impact on protection schemes based on negative-sequence components. It covers both type III wind turbines and full-size converter-based IBRs. Additionally, this report reviews strategies for grid-forming controlled inverters to generate negative-sequence current during unbalanced faults, in addition to grid-following controlled ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Seismic Elastic Double-Beam Characterization of Faults and Fractures for CO₂ Storage Site Selection

Site characterization for underground injection and storage of gigatonne-scale CO₂ requires reliable and cost-effective methods to detect and characterize faults and fractures and to assess their stress state and fault activation potential. This is critical, as wastewater injection and disposal have been shown to activate faults and induce earthquakes, and CO₂ leakage remains a key concern for long-term storage. In this project, we developed seismic methods to detect and characterize large-scale sedimentary and crystalline basement faults and associated small-scale fractures below conventional seismic imaging resolution using multicomponent (9C) surface seismic data. Machine learning was used to automatically interpret large-scale faults, providing key information for estimating the maximum magnitude of potential induced earthquakes. High-fidelity imaging was achieved by exploiting redundancy across multiple elastic wave modes, where independent images from different modes and frequencies cross-validate each other. We also used our nonlinear signal comparison (NLSC) method for ground roll removal, improving data quality in complex near-surface conditions. The methods were validated using field data acquired in central Montana. Results show that basement faults extend into the sedimentary section and that small-scale fractures are widespread above the basement. The inferred stress orientation is consistent with regional stress data, and the estimated maximum induced earthquake magnitude is small (Mw ~2.3). The developed workflow provides a practical approach for fault and fracture characterization and for assessing induced seismicity and leakage risk. It is directly applicable to CO₂ storage site selection and to other subsurface systems.

02 PETROLEUM↗

Deep learning model for fast, science-based forecasting of fluid migration along faults in geologic carbon storage scenarios

Effective long-term geologic storage depends on robust site selection and credible, science-based forecasting of subsurface behavior to ensure storage integrity. For this work, we develop a deep learning–based reduced-order model (ROM) to quantify potential carbon dioxide (CO₂) and brine migration through geological faults. The ROM combines a Transformer model for binary classification and a Stacked Ensemble for regression, trained on a comprehensive dataset generated from 1400 physics-based reservoir simulations. Key geologic and operational parameters—including fault geometry, reservoir structure, and injection conditions—were systematically varied to capture a wide range of fluid migration scenarios. The ROM accurately predicts the onset of migration, cumulative migration volumes of both CO₂ and brine, and associated migration rates, as compared to an independent set of validation simulations, while significantly reducing computational cost compared to traditional simulation methods. Model performance was evaluated across diverse fault configurations, revealing that shallow reservoir geometry and fault angle are among the most influential factors governing migration behavior. Sensitivity analysis using SHapley Additive exPlanations (SHAP) provided interpretability, revealing distinct patterns in how geological and operational features drive transient versus cumulative migration outcomes. The ROM’s ability to rapidly simulate fault migration scenarios enables efficient sensitivity analyses, scenario evaluations, and decision support for site selection and monitoring design. This approach enhances the safety, scalability, and long-term operational performance of geologic carbon storage (GCS) systems by providing a robust, interpretable tool for predicting subsurface fluid migration and assessing fault-related migration potential.

42 ENGINEERING↗

Relocating microseismicity from downhole monitoring of the Decatur CCS site using a modified double-difference algorithm

SUMMARY The injection of CO2 at the Decatur carbon capture and storage site has generated significant microseismic activity, which occurs in distinct spatial clusters up to approximately 2.2 km from the primary injection well. Accurate and precise event locations are vital for the characterization of the microseismicity to help understand the reservoir response to the CO2 injection, whilst enabling the identification of minor faults and fractures below the resolution of conventional active seismic imaging. However, microseismic monitoring of fluid injection sites, such as Decatur, is often performed using a network of borehole sensors often from a single well. While these downhole sensors have excellent detection capabilities, their poor azimuthal coverage limits the ability to precisely determine event locations. We have developed a modified double-difference relocation algorithm suitable for both 1-D and 3-D velocity models, and which incorporates differential back azimuth observations to allow the benefits of the original double-difference algorithm to be applicable to a downhole microseismic monitoring setting. Applying the modified double-difference algorithm to the microseismicity at Decatur, we have successfully relocated 4293 events. The relocation included over 59 million observations for 757 285 event pairs, split across seven geographic regions. Despite the majority of observations being recorded in only two boreholes, with an almost identical azimuthal coverage, the results have shown to be reliable with significantly reduced residuals and low uncertainties associated with the final locations. We have analysed the residuals in terms of their association with each geographic region, data type, station and individual events, to fully appreciate their influence in the inversion and the fit of the data to the final set of event locations. For each region, the relocated seismicity has become less diffuse with improved clustering, and with newly visible linear features often orientated in a NE–SW direction. These results show the potential improvements that can be made to microseismic event locations recorded by a borehole network with a limited and variable azimuthal distribution.

58 GEOSCIENCES↗

A Boundary Element Model for Assessing Large‐Scale Pressurization in Faulted Geological Storage Systems

Assessing large-scale pressurization at the regional scale—a possible outcome of large subsurface storage applications such as wastewater injection and geological carbon sequestration—presents significant computational challenges. These challenges are particularly pronounced when accounting for complex geologic structures with multiple reservoir and caprock layers, fault zones, and wells. This study introduces a computationally efficient model that integrates single-phase semi-analytical solutions with a boundary element (BE) approach. The model simulates pressure propagation in multilayered 3D systems, including vertical faults, caprock, basement, and confining units. We apply this new model to a representative scenario involving CO 2 injection near a partially sealing fault with verification against an independent two-phase flow model. Results demonstrate that our model accurately captures far-field pressure responses and that, outside the CO 2 plume zone, pressure predictions from single-phase and two-phase models are nearly identical. This supports the use of single-phase models like ours for efficient estimation of far-field pressure changes. Additionally, we demonstrate its effectiveness at a large scale, incorporating multiple wells and faults. With its ability to represent multiple wells, fault zones, and geological heterogeneity, our model is well suited for assessments of basin-scale pressurization. Its computational efficiency also makes it a promising tool for integration with optimization frameworks aimed at designing and managing injection strategies in faulted storage systems.

Cihan, A. [Lawrence Berkeley National Laboratory (↗

Induced seismicity and geothermal energy production in the Salton Sea Geothermal Field, California

We analyze the relationship between geothermal energy production and seismic hazards in the Salton Sea Geothermal Field (SSGF) between 1972 and 2022. A clear increase in seismic activity accompanies geothermal energy production and is greatest to the east of the Brawley fault, where the amount of injection exceeds the amount of production. We estimate that, whereas there was a 2% chance of a M6.07 earthquake nucleating inside the SSGF within a fifty-year period prior to energy production (pre-production), there is an equal probability that a M6.70 earthquake nucleates there in a fifty-year period during which historically average energy production conditions persist (syn-production). Similarly, we estimate a 2% chance of a M7.15 and M6.92 occurring in the broader Brawley Seismic Zone (excluding the SSGF) within a fifty-year period during the pre- and syn-production eras, respectively. We find that linear regression models fail to reliably forecast the background seismicity rate as a function of fluid production and injection.

15 GEOTHERMAL ENERGY↗

Grid-Forming Inverters for Stability Improvements in Bulk Power Systems with High Inverter-Based Resources Penetration

The grid-forming inverter (GFM) has been considered recently as a means to enhance grid stability in areas with Inverter-based Resources (IBRs) concentration. This paper assesses the potential improvements the GFM can bring to Bulk-power Systems (BPS) through two distinct studies. The first study was conducted on West Texas in ERCOT with presence of more than 35GW of IBRs, the Grid-Following (GFL) batteries were replaced with GFM batteries. The results demonstrate that the GFM significantly improved the voltage profile and active power injection during and after a fault. The second study focused on a local area within ERCOT grid. In this case, a battery operating as GFL within the local study area was replaced with a GFM battery. The findings clearly illustrate that GFM can strengthen the area and allow a higher IBRs power generation and a higher power export from the local study area.

Quedan, Amro↗