Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fast neutron imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

Grating-Based Imaging-Scattering with Portable Neutron Generator

Company: Adelphi Technology, Inc. Title: Grating-Based Imaging-Scattering with Portable Neutron Generator PI: Dr. Jay Theodore Cremer, Jr. Topic: 26a Statement of the problem or situation that is being addressed. Successful plant growth depends upon an efficient and robust root system. The plant root is part of a larger system of water and microbial flows in the soil system. While much effort has been exerted to develop an imaging system for water, microbes, and roots, the problem is challenging, and no widely accepted imaging method currently exists. The optical solutions use a highly modified soil system. X-ray imaging methods are insensitive to the soft tissues in the presence of sand. Thermal neutron imaging has been often tested, but found inadequate, due to limited access and low image resolution. This project will develop a new strategy for neutron imaging of plant/soil systems. The project will allow long duration experiments in greenhouse environments and increase the image information content to the micron scale. General statement of how this problem is being addressed. Portable, rugged thermal and fast neutron sources are being developed where portable means a two-soldier team can carry the source and power unit to survey rough terrain for explosives. In the past decade, microfabrication of X-ray and thermal/cold neutron optics has opened a new imaging strategy. The standard transmission image is now supplemented with simultaneous acquisition of a phase contrast image and an image revealing scattering features. In materials science, the interferometric neutron scattering image has been used to detect early crack formation in stressed additive manufacturing test samples. The detection requires sensitivity to scattering features at the 1-micron scale. By addition of our proposed grating-optic to Adelphi Technology’s radiographic/tomographic imaging system, which is based on portable thermal neutron source, the resulting thermal neutron scatter image of the plant/soil system, will reveal details at 1-micron. Commercial Applications and Other Benefits Neutron interferometry imaging has greater penetration through large metal components compared to industrial X-ray imaging. The low-cost, large area optics developed for greenhouse applications, combined with the robust, portable neutron generator, can then be marketed as a system for inspection of additive manufactured components. In the aerospace industry, all freshly printed components are validated with X-ray CT. Scheduled maintenance again requires X-ray CT as the ability to predict aerospace component lifetime does not yet exist. Large aerospace components are only partially observed with X-ray imaging. Key Words Neutron radiography/tomography, grating interferometry, thermal neutron generator imaging, plant root and soil imaging, rhizosphere imaging, deployable neutron imaging systems Summary for Members of Congress A rugged, portable source of thermal neutrons is adapted for neutron interferometry imaging with the addition of low-cost, 3D printed optics. The first application of our proposed deployable, compact thermal neutron generator imaging system, using a grating optic, is plant root/soil science in greenhouse settings and agricultural laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Investigation of a Scalable Fast Neutron Radiography Panel

Advances in flat-panel radiography device design have increased the use of radiation imaging as a nondestructive evaluation tool. Neutron radiography offers many advantages compared to photon-based radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear imaging to diagnose and correct target-driver registration at high-repetition-rate for improved reactor efficiency

Inertial Confinement Fusion produces energy from a burning plasma lasting a fraction of a nanosecond. Power plant designs based on Inertial Fusion Energy (IFE) will need to ignite targets 1-10 times a second, fired as projectiles into a chamber and delivering the driver to the target location. Driver asymmetry is known to impact ICF experiments at gain near unity and remains a candidate for primary yield degradation, and therefore fusion power plant energy output, for high-gain target designs. For a Fusion Power Plant (FPP), continuous and real-time monitoring of target performance provides an opportunity to stabilize or correct the target-driver registration. This requires x-ray and neutron imaging with a large field-of-view, sufficiently high resolution, fast analysis and to subtend a minimal solid angle. We introduce design criteria for such an imaging system that uses a coded aperture and time-gated, lens-coupled scintillators as a viable solution and outline the research steps required to field such a system. Integrating the imaging system into an IFE power plant as part of an active feedback loop could increase average power output by reducing the failure rate due to mis-aligned drivers with respect to the target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficiency Studies of Fast Neutron Tracking Using MCNP

Fast neutron identification and spectroscopy is of great interest to nuclear physics experiments. Using the neutron elastic scattering, the fast neutron momentum can be measured. Wang and Morris introduced the theoretical concept that the initial fast neutron momentum can be derived from up to three consecutive elastic collisions between the neutron and the target, including the information of two consecutive recoil ion tracks and the vertex position of the third collision or two consecutive elastic collisions with the timing information. Here, we also include the additional possibility of measuring the deposited energies from the recoil ions. In this paper, we simulate the neutron elastic scattering using the Monte Carlo N-Particle Transport Code (MCNP) and study the corresponding neutron detection and tracking efficiency. The corresponding efficiency and the scattering distances are simulated with different target materials, especially natural silicon (92.23%28Si, 4.67%29Si, and 3.1%30Si) and helium-4 (4He). The timing of collision and the recoil ion energy are also investigated, which are important characters for the detector design. We also calculate the ion traveling range for different energies using the software, “The Stopping and Range of Ions in Matter (SRIM)”, showing that the ion track can be most conveniently observed in 4He unless sub-micron spatial resolution can be obtained in silicon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast Neutron Radiography Simulations

Conclusions: Elements other than detector array can heavily impact performance; Must consider a variety of alterations to an imaging array to determine an optimal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Epithermal and Fast Neutron Radiography Facility HFIR Futures – Enhanced Capabilities Series (Vol. 8)

The Sustaining and Enhancing Nuclear Science Initiative at Oak Ridge National Laboratory (ORNL) was created to explore potential enhancements to scientific capabilities in the High Flux Isotope Reactor as part of a reactor pressure vessel replacement project. One proposed scientific enhancement included creation of an epithermal and fast neutron radiography station on the HB-3 beam tube with the capability to image highly radioactive specimens such as irradiated nuclear fuel rods, isotope production targets, or spallation neutron target materials. This document summarizes findings and recommendations from a working group of ORNL staff tasked with conceptualizing such a facility and includes a background of similar instruments at other research facilities, technical specifications, and an estimate of procurement cost and schedule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Converting existing optical detectors into fast x-ray detectors

Here, the very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NEREIDS

NEREIDS (NEutron REsonance Imaging Diagnostic Suite) is a research-grade toolkit for neutron resonance imaging, providing a Rust physics core, Python bindings, and NeXus/HDF5-compliant data I/O, with a path to fast, standalone GUI workflows for VENUS/MARS.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Here, three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synergistic effects of Al, Ga, and In doping on ZnO nanorod arrays grown via citrate-assisted hydrothermal technique for highly efficient and fast scintillator screens

To be used as efficient alpha particle scintillator in the fields of nuclear security, nuclear nonproliferation and high-energy physics, scintillator screens must have high light output and fast decay properties. While there has been a great deal of progress in scintillation efficiency, achieving fast decay time properties are still a challenge. In this work, the near band edge (NBE) UV luminescence and alpha particle induced scintillation properties of vertically aligned densely packed ZnO nanorods (NRs) doped with Al, Ga, and In have been thoroughly investigated. The high crystalline hexagonal wurtzite structure with a strong orientation through the c -axis plane (002) and aspect ratios in the range 13–22 have been observed for all ZnO NRs. Electron paramagnetic resonance (EPR) analysis exhibited paramagnetic signals at g ≈ 1.96 for all ZnO NRs. A cost effective green hydrothermal synthesis technique was employed to grow well-aligned NRs. Using citrate as an additive acting as a strong reducing agent in the solution during the crystal growth, defects on the surface are significantly suppressed, thereby enhancing the NBE UV emission. Significantly higher NBE UV emission was observed from the top surface of ZnO NRs in cathodoluminescence (CL) microscopy. Results show that citrate assisted donor doping of ZnO NRs not only reduces the defect emission and NBE self-absorption, but also induces fast decay time (~ 600–700 ps), which makes ZnO NRs a good candidate for fast alpha particle scintillator screens used in associated particle imaging for time and direction tagging of individual neutrons generated in D–T and D–D neutron generators.

36 MATERIALS SCIENCE↗

The Los Alamos neutron spectrometer for the Lunar Scout-1 mission

We review the current status of the Los Alamos program to develop a neutron spectrometer for the Lunar Scout-1 mission, which is the first of two such missions to obtain global compositional, gravity, topography, and image maps of the lunar surface during nominal one-year missions. The neutron spectrometer will measure fast and slow (epithermal and thermal) neutrons in the ranges of 0.5 MeV to 25 MeV and 0.01 eV to more than 1 keV, respectively. The neutron spectrometer will consist of two independent instruments, a fast-neutron one, and a thermal and epithermal one. The measured neutron fluxes are very sensitive to hydrogen in the top meter of the lunar surface and provide additional information about lunar composition.

Auchampaugh, George↗

Efficient Prompt Scintillation and Fast Neutron-Gamma Ray Discrimination Using Amorphous Blends of Difluorenylsilane Organic Glass and in-situ Polymerized Vinyltoluene

High performance radiation detection materials are an integral part of national security, medical imaging, and nuclear physics applications. Those that offer compositional and manufacturing versatility are of particular interest. In this work, we report a new family of radiological particle-discriminating scintillators containing bis(9,9-dimethyl-9H-fluoren-2- yl)diphenylsilane (compound “P2”) and in-situ polymerized vinyltoluene (PVT) that is phase stable and mechanically robust at any blend ratio. The gamma-ray light yield increases nearly linearly across the composition range, to ~16,400 photons/MeV at 75 % wt. P2. These materials are also capable of γ/n pulse shape discrimination (PSD) and between 20-50 % P2 loading are competitive with the PSD quality of commercially-available plastic scintillators. The 137 Cs scintillation rise and decay times are sensitive to P2 loading and approach the values for “pure” P2. Additionally, the radiation detection performance of P2-PVT blends can be made stable in 60°C air for at least 1.5 months with the application of a thin film of poly(vinylalcohol) to the scintillator surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗