Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fast frequency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-pressure oxygen impact tester

To extend the compatibility evaluation of candidate materials in oxygen, a high-pressure oxygen impact tester has been designed, developed, and installed at NASA/MSFC, Huntsville, Alabama. The tester has an operating range from ambient to 69,000 newton/sq m (10,000 psig) pressures and from the normal boiling point of liquid oxygen to 394 K (121 C) temperatures. The tester was designed to deliver 97.63 joules (72 ft-lb) of impact energy; however, variable height and weight can be achieved for threshold analysis. The system is completely remote and highly automated to furnish safe, reliable operation. High-frequency, fast-response instrumentation capabilities are provided to ensure maximum information output with the hope of minimizing the number of tests required for material acceptance.

Raniere, F. D.↗

Flight test results of an active flutter suppression system installed on a remotely piloted research vehicle

Flight flutter test results of the first aeroelastic research wing of NASA's Drones for Aerodynamic and Structural Testing (DAST) program are presented. The implementation of the flutter suppression system and the flight test operation are described. The conduct of the flutter testing and the near-real time damping estimation algorithm are also described in detail. Flight data was obtained at Mach numbers up to 0.91 and was of high quality. Response to fast frequency sweep excitation provided reliable damping estimates and the open-loop flutter boundary was well defined. Evidence of angle-of-attack effects upon damping at high transonic Mach numbers is also presented. While the flutter suppression system provided augmented damping at speeds below the flutter boundary, an error in the implementation of the system gain caused the system to be less stable than predicted and the vehicle encountered system-on flutter on the third flight.

Edwards, J. W.↗

A fast, reliable algorithm for computing frequency responses of state space models

Computation of frequency responses for large order systems described by time invariant state space systems often provides a bottleneck in control system analysis. It is shown that banding the A-matrix in the state space model can effectively reduce the computation time for such systems while maintaining reliability in the results produced.

Wette, Matt↗

Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-ω) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-ω spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

Pressure Sensitive Paint↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New anemometer has fast response, measures dynamic pressure directly

A simple anemometer having a fast response to high frequency wind fluctuations by direct measurement of two drag-force components in orthogonal planes is described. It may be used to determine wind profiles to extensive heights and would be helpful in takeoff and landing of light planes.

Lynch, J. W.↗

Compensating for Range Migration in Synthetic-Aperture Radar

Correlation algorithm sharpens radar imagery. Azimuthal correlation of point-target response performed in frequency domain by fast Fourier transforms relatively efficient in arithmetic operations. Frequencydomain azimuthal response has simple form that enables correction for range migration made simultaneously and over wide area, thereby providing many picture elements.

Jin, M. Y.↗

Utilizing grid–supportive load response to shape resilient frequency control of the power grid

The increasing penetration of renewable energy sources and the retirement of conventional generation units have decreased system inertia, making power systems more vulnerable to resilience and stability issues. To address this problem, this paper proposes a novel approach using grid-supportive loads (GSLs) to provide a fast and concise primary frequency response and a deep deterministic policy gradient agent-based secondary controller to restore the system frequency to the nominal value. The proposed method is evaluated on the single-area and multi-area test systems. The simulation results demonstrate that using GSLs enhances the power system's stability and resilience. Compared to conventional controllers, the frequency nadir is improved with GSLs. Additionally, the proposed method effectively enhances resilience even with high penetration. These findings indicate that the proposed approach can improve the resilience and stability of power systems and provide a promising solution for future power systems. The results of this study underscore the importance of utilizing innovative approaches to enhance the stability and resilience of power systems in the context of high penetration of renewable energy sources and the retirement of conventional generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Providing Inertial Response on Dynamic Loads of Wind Turbine Drivetrains

There has been growing demand from the power industry for wind power plants to support power system operations. One such requirement is for wind turbines to provide ancillary services in the form of inertial response. When the grid frequency drops, it is essential for wind turbine generators (WTGs) to inject kinetic energy stored in their inertia into the grid to help arrest the frequency decline. However, the impacts of inertial response on the structural loads of the wind turbine have not been given much attention. To bridge this gap, this paper utilizes a holistic model for both fixed-speed and variable-speed WTGs by integrating the aeroelastic wind turbine model in FAST, developed by the National Renewable Energy Laboratory, with the electromechanical drivetrain model in SimDriveline and SimPowerSystems.

17 WIND ENERGY↗

Impact of Transportation Electrification on the System's Dynamic Frequency Response

Transportation electrification is an integral component of the energy decarbonization transition. This paper investigates the impact of distributed energy resources (DERs), including distributed photovoltaics (DPV) and electric vehicles (EVs), in the primary frequency response of the power grid. Increasing DER adoption poses challenges to maintaining grid frequency stability. However, DERs' ability to provide fast frequency regulation services-primary frequency response (PFR) and secondary frequency response (SFR)-can be exploited to recover the frequency after an N-1 contingency event in the system. This paper also investigates the importance of a droop control strategy through dynamic models of DPV and EV to provide the primary frequency regulation services following the contingency event. A dynamic EV model, based on the PVD1 model Western Electricity Coordinating Council (WECC) introduced, has been used for the simulation. Further, DERs' primary frequency response is studied for five different cases of DER penetration levels after the system is exposed to the generator trip. Additionally, different frequency regulation capacities of EVs are analyzed. The studies show that an increment in DERs capacity providing effective PFR can improve the system frequency nadir and stabilize the frequency faster after the generation trip contingency.

distributed energy resources↗

Impact of Transportation Electrification on the System's Dynamic Frequency Response: Preprint

Transportation electrification is an integral component of the energy decarbonization transition. This paper investigates the impact of distributed energy resources (DERs), including distributed photovoltaics (DPV) and electric vehicles (EVs), in the primary frequency response of the power grid. Increasing DER adoption poses challenges to maintaining grid frequency stability. However, DERs' ability to provide fast frequency regulation services-primary frequency response (PFR) and secondary frequency response (SFR)-can be exploited to recover the frequency after an N-1 contingency event in the system. This paper also investigates the importance of a droop control strategy through dynamic models of DPV and EV to provide the primary frequency regulation services following the contingency event. A dynamic EV model, based on the PVDl model Western Electricity Coordinating Council (WECC) introduced, has been used for the simulation. Further, DERs' primary frequency response is studied for five different cases of DER penetration levels after the system is exposed to the generator trip. Additionally, different frequency regulation capacities of EVs are analyzed. The studies show that an increment in DERs capacity providing effective PFR can improve the system frequency nadir and stabilize the frequency faster after the generation trip contingency.

ADVANCED PROPULSION SYSTEMS↗

Use-Phase Drives Lithium-Ion Battery Life Cycle Environmental Impacts When Used for Frequency Regulation

Battery storage systems are attractive alternatives to conventional generators for frequency regulation due to their fast response time, high cycle efficiency, flexible scale, and decreasing cost. However, their implementation does not consistently reduce environmental impacts. To assess these impacts, we employed a life cycle assessment (LCA) framework. Our framework couples cradle-to-gate and end-of-life LCA data on lithium-ion batteries with a unit commitment and dispatch model. The model is run on a 9-bus power system with energy storage used for frequency regulation. The addition of energy storage changes generator commitment and dispatch, causing changes in the quantities of each fuel type consumed. This results in increased environmental impacts in most scenarios. The impacts caused by the changes in the power system operation (i.e., use-phase impacts) outweigh upstream and end-of-life impacts in the majority of scenarios analyzed with the magnitude most influenced by electricity mix and fuel price. Of parameters specific to the battery, round trip efficiency has the greatest effect.

25 ENERGY STORAGE↗

Framework for Supporting Adaptive Droop Based Power Electronic Systems

The electric grid is evolving into an electrical network composed of power electronic converters interconnected with renewable and energy storage technologies. This requires the adoption of more advanced control such as volt/var regulation, fast frequency control, and active power frequency response. This work presents a communication and control framework to support dynamically changing droop control segments that can be used for different optimization schemes. Results are presented to work in a controller hardware in the loop testbed.

Starke, Michael↗

A spectral element approach to wave motion in layered solids

A matrix methodology similar to that of the finite element method is developed for the analysis of stress waves in layered solids. Because the mass distribution is modeled exactly, the approach gives the exact frequency response of each layer. The fast Fourier transform and Fourier series are used for inversion to the time/space domain. The impact of a structured medium with multiple layers is used to demonstrate the method. Comparison with existing propagator and direct global matrix methods show the present approach to be computationally more efficient.

Rizzi, S. A.↗

PV Inverter Fault Response Including Momentary Cessation, Frequency-Watt, and Virtual Inertia

This paper presents two photovoltaic (PV) inverter control methods and an analysis of the two under a significant three-phase transmission line fault contingencies in the Hawaiian island of Oahu power system. Simulations are presented for the two control methods on the island power system with a high penetration of PV generation, approximately 40% of the total. The two control methods discussed are similar: one is a proportional frequency-watt controller, and the second is a proportional-derivative controller, a frequency-watt controller with virtual inertia. Both methods can be beneficial for fast frequency support. The inverter model also emulates inverter fault response including 'momentary cessation' and recovery during low voltage events. The study presented in this paper utilizes a validated power system model of the Hawaiian island of Oahu, modified to include PV resources with the two custom developed control models. Dynamic simulations with PSS/E are presented during a significant transmission line three-phase fault contingency. Simulations are presented with and without PV reserve margin. In addition, a parameter sensitivity analysis is presented for the control methods. Results indicate both methods can significantly improve system response during fault events. Findings indicate that transmission faults can produce severe frequency events, and that fast recovery from momentary cessation is crucial to mitigate severity.

14 SOLAR ENERGY↗

Fast particles in drift wave turbulence

This study aims to incorporate the effects of fast particles into our present fluid model for tokamak transport. The parameter ε f = ω / ω f, where ω is the mode frequency and ω f is the typical frequency of the fast particles, which enters as a factor in front of the fast particle response. Thus, for trapped fast particles, where ω f = ω pres the precession frequency of the fast particles, this parameter is of order 10 – 2 for drift waves, and thus, the fast particle response can be neglected. However, ε f will be of order 1 for fast particle modes such as in the fishbone instability. An important turbulence property, affecting both these limits, is resonance broadening. Effects of resonance broadening have recently been considered for fast particle instabilities, often coupled directly to the linear growth rate, while we here consider the original Dupree formulation where the turbulence directly drives a nonlinear frequency shift. Resonance broadening has a general tendency to counteract dissipative wave particle resonances. This has been observed for fast particle instabilities. Here, there is a resonant external source for the fast particles, so the instability survives if this source is dominant over the resonance broadening. For drift waves, however, external sources are not resonant since ε f << 1. Furthermore, the resonance broadening is able to remove the dissipative wave particle resonance completely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗