Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “false positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Testing of Haar-Like Feature in Region of Interest Detection for Automated Target Recognition (ATR) System

The objectives of this project were to develop a ROI (Region of Interest) detector using Haar-like feature similar to the face detection in Intel's OpenCV library, implement it in Matlab code, and test the performance of the new ROI detector against the existing ROI detector that uses Optimal Trade-off Maximum Average Correlation Height filter (OTMACH). The ROI detector included 3 parts: 1, Automated Haar-like feature selection in finding a small set of the most relevant Haar-like features for detecting ROIs that contained a target. 2, Having the small set of Haar-like features from the last step, a neural network needed to be trained to recognize ROIs with targets by taking the Haar-like features as inputs. 3, using the trained neural network from the last step, a filtering method needed to be developed to process the neural network responses into a small set of regions of interests. This needed to be coded in Matlab. All the 3 parts needed to be coded in Matlab. The parameters in the detector needed to be trained by machine learning and tested with specific datasets. Since OpenCV library and Haar-like feature were not available in Matlab, the Haar-like feature calculation needed to be implemented in Matlab. The codes for Adaptive Boosting and max/min filters in Matlab could to be found from the Internet but needed to be integrated to serve the purpose of this project. The performance of the new detector was tested by comparing the accuracy and the speed of the new detector against the existing OTMACH detector. The speed was referred as the average speed to find the regions of interests in an image. The accuracy was measured by the number of false positives (false alarms) at the same detection rate between the two detectors.

neural network↗

Blind QC trend presentation

Blind testing is used to evaluate performance of the radiobioassay laboratory. DOE-STD-1112-2019 requires a radiobioassay program to perform blind testing at a documented frequency including accuracy, false positive, false negative, and sensitivity evaluations. INL trends accuracy determinations over time for bias, agreement, and precision. Trends have been identified for certain isotopes in urine and feces that have not been fully explained. This presentation will review those identified trends and discuss possible causes and solutions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantitative Detection of Single Molecules in Fluorescence Microscopy Images

Fluorescence imaging and counting of single molecules adsorbed or bound to surfaces are being employed in a number of quantitative analysis applications. Reliable molecular counts with knowledge of counting uncertainties, both false-positive and false-negative probabilities, are critical to these applications. By counting stationary single molecules on a surface, spatial criteria may be applied to the image analysis to improve confidence in detection, which is especially critical when detecting single fluorescent labels. In this work, we describe a simple approach to incorporating spatial criteria for counting single molecules by using an intensity threshold to locate regions with multiple, adjacent intense pixels, where the size of these regions is guided by the point-spread function of the microscope. By requiring multiple, spatially correlated bright pixels, false-positive events resulting from random samples of background noise are minimized. The reliability of detection is established by quantitative knowledge of the distributions of background and signals. By measuring and modeling both the background and single-molecule intensity distributions, false-positive and false-negative detection probabilities are estimated for arbitrary threshold parameters by using combinatorial statistics. From this theory, detection parameters can be optimized to minimize false-positive and false-negative probabilities, which can be calculated explicitly. For detection of single rhodamine 6G molecules at a threshold set at 2.5 times the standard deviation above background, the false-negative probability was only 1.5%, determined from distributions of single-molecule intensities on well-populated surfaces, and the false-positive probability from background noise was 2.8 spots per 50 × 50 μm image. Furthermore, the false-positive events compare favorably with theoretical probabilities calculated using combinatorial statistical analysis and simulated false-positive events counted in images of random noise.

36 MATERIALS SCIENCE↗

Optimally configuring a measurement system to detect diversions from a nuclear fuel cycle

The civilian nuclear fuel cycle is an industrial process that produces electrical power from the nuclear fission of uranium. Using a measurement system to accurately account for nuclear material, such as uranium, in a fuel cycle is important because of the possible loss or diversion of this potentially dangerous material. A measurement system is defined by a set of measurement methods, or “devices,” used to account for material flows and inventory values at specific locations in the fuel cycle. Here, we develop a simulation-optimization algorithm and an integer-programming model to find the best, or near-best, resource-limited measurement system with a high degree of confidence. The simulation-optimization algorithm minimizes a weighted sum of false positive and false negative diversion-detection probabilities while accounting for material quantities and measurement errors across a finite, discrete time horizon in hypothetical non-diversion and diversion contexts. In each time period, the estimated cumulative material unaccounted for is compared to a fixed or an optimized threshold value to assess if a “significant amount of material” is lost from a measurement system. The integer-programming model minimizes the population variance of the estimated material loss, i.e., material unaccounted for, in a measurement system. We analyze three potential problems in nuclear fuel cycle measurement systems: (i) given location-dependent device precisions, find the configuration of n devices at n locations ( n = 3) that gives the lowest corresponding objective values using the simulation-optimization algorithm and integer-programming model, (ii) find the location at which improving device precision reduces objective values the most using the simulation-optimization algorithm, and determine the effect of measurement frequency on measurement system configurations and objective values using the simulation-optimization algorithm. We obtain comparable results for each problem at least an order of magnitude faster than existing methods do. Using an optimized, rather than fixed, detection threshold in the simulation-optimization algorithm reduces the weighted sum of false positive and false negative probabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Global Sensitivity Analysis with Small Sample Sizes: Ordinary Least Squares Approach

A new version of global sensitivity analysis is developed in this paper. This new version coupled with tools from statistics, machine learning, and optimization can devise small sample sizes that allow for the accurate ordering of sensitivity coefficients for the first 10-30 most sensitive chemical reactions in complex chemical-kinetic mechanisms, and is particularly useful for studying the chemistry in realistic devices. A key part of the paper is calibration of these small samples. Because these small sample sizes are developed for use in realistic combustion devices, the calibration is done over the ranges of conditions in such devices, with a test case being the operating conditions of a compression ignition engine studied earlier. Compression ignition engines operate under low-temperature combustion conditions with quite complicated chemistry making this calibration difficult, leading to the possibility of false positives and false negatives in the ordering of the reactions. So an important aspect of the paper is showing how to handle the trade-off between false positives and false negatives using ideas from the multiobjective optimization literature. The combination of the new global sensitivity method and the calibration are sample sizes a factor of approximately 10 times smaller than were available with our previous algorithm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification

Purpose: To evaluate methods of pretreatment IMRT analysis, using real measurements performed with a commercial 2D detector array, for clinical relevance and accuracy by comparing clinical DVH parameters. Methods: We divided the work into two parts. The first part consisted of six in-phantom tests aimed to study the sensitivity of the different analysis methods. Beam fluences, 3D dose distribution, and DVH of an unaltered original plan were compared to those of the delivered plan, in which an error had been intentionally introduced. The second part consisted of comparing gamma analysis with DVH metrics for 17 patient plans from various sites. Beam fluences were measured with the MapCHECK 2 detector, per-beam planar analysis was performed with the MapCHECK software, and 3D gamma analysis and the DVH evaluation were performed using 3DVH software. Results: In a per-beam gamma analysis some of the tests yielded false positives or false negatives. However, the 3DVH software correctly described the DVH of the plan which included the error. The measured DVH from the plan with controlled error agreed with the planned DVH within 2% dose or 2% volume. We also found that a gamma criterion of 3%/3 mm was too lax to detect some of the forced errors. Global analysis masked some problems, while local analysis magnified irrelevant errors at low doses. Small hotspots were missed for all metrics due to the spatial resolution of the detector panel. DVH analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results, with the exception of very small volume structures such as the eyes and the lenses. Target coverage (D{sub 98} and D{sub 95}) of the measured plan was systematically lower than that predicted by the treatment planning system, while other DVH characteristics varied depending on the parameter and organ. Conclusions: We found no correlation between the gamma index and the clinical impact of a discrepancy for any of the gamma index evaluation possibilities (global, local, 2D, or 3D). Some of the tests yielded false positives or false negatives in a per-beam gamma analysis. However, they were correctly accounted for in a DVH analysis. We also showed that 3DVH software is reliable for our tests, and is a viable method for correlating planar discrepancies with clinical relevance by comparing the measured DVH of target and OAR's with clinical tolerance.

60 APPLIED LIFE SCIENCES↗

Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm

Purpose: The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. Methods: The authors describe a DIR based adaptive radiotherapy workflow, using CT and cone-beam CT (CBCT) imaging. The transformations that mapped the anatomy between the two time points were obtained using four different DIR approaches available in NiftyReg. These included a standard unidirectional algorithm and more sophisticated bidirectional ones that encourage or ensure inverse consistency. The forward (CT-to-CBCT) deformation vector fields (DVFs) were used to propagate the CT Hounsfield units and structures to the daily geometry for “dose of the day” calculations, while the backward (CBCT-to-CT) DVFs were used to remap the dose of the day onto the planning CT (pCT). Data from five head and neck patients were used to evaluate the performance of each implementation based on geometrical matching, physical properties of the DVFs, and similarity between warped dose distributions. Geometrical matching was verified in terms of dice similarity coefficient (DSC), distance transform, false positives, and false negatives. The physical properties of the DVFs were assessed calculating the harmonic energy, determinant of the Jacobian, and inverse consistency error of the transformations. Dose distributions were displayed on the pCT dose space and compared using dose difference (DD), distance to dose difference, and dose volume histograms. Results: All the DIR algorithms gave similar results in terms of geometrical matching, with an average DSC of 0.85 ± 0.08, but the underlying properties of the DVFs varied in terms of smoothness and inverse consistency. When comparing the doses warped by different algorithms, we found a root mean square DD of 1.9% ± 0.8% of the prescribed dose (pD) and that an average of 9% ± 4% of voxels within the treated volume failed a 2%pD DD-test (DD{sub 2%-pp}). Larger DD{sub 2%-pp} was found within the high dose gradient (21% ± 6%) and regions where the CBCT quality was poorer (28% ± 9%). The differences when estimating the mean and maximum dose delivered to organs-at-risk were up to 2.0%pD and 2.8%pD, respectively. Conclusions: The authors evaluated several DIR algorithms for CT-to-CBCT registrations. In spite of all methods resulting in comparable geometrical matching, the choice of DIR implementation leads to uncertainties in dose warped, particularly in regions of high gradient and/or poor imaging quality.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-11: On the Sensitivity of An EPID-Based 3D Dose Verification System to Detect Delivery Errors in VMAT Treatments

Purpose: To investigate the sensitivity of an EPID-based 3D dose verification system to detect delivery errors in VMAT treatments. Methods: For this study 41 EPID-reconstructed 3D in vivo dose distributions of 15 different VMAT plans (H&N, lung, prostate and rectum) were selected. To simulate the effect of delivery errors, their TPS plans were modified by: 1) scaling of the monitor units by ±3% and ±6% and 2) systematic shifting of leaf bank positions by ±1mm, ±2mm and ±5mm. The 3D in vivo dose distributions where then compared to the unmodified and modified treatment plans. To determine the detectability of the various delivery errors, we made use of a receiver operator characteristic (ROC) methodology. True positive and false positive rates were calculated as a function of the γ-parameters γmean, γ1% (near-maximum γ) and the PTV dose parameter ΔD{sub 50} (i.e. D{sub 50}(EPID)-D{sub 50}(TPS)). The ROC curve is constructed by plotting the true positive rate vs. the false positive rate. The area under the ROC curve (AUC) then serves as a measure of the performance of the EPID dosimetry system in detecting a particular error; an ideal system has AUC=1. Results: The AUC ranges for the machine output errors and systematic leaf position errors were [0.64 – 0.93] and [0.48 – 0.92] respectively using γmean, [0.57 – 0.79] and [0.46 – 0.85] using γ1% and [0.61 – 0.77] and [ 0.48 – 0.62] using ΔD{sub 50}. Conclusion: For the verification of VMAT deliveries, the parameter γmean is the best discriminator for the detection of systematic leaf position errors and monitor unit scaling errors. Compared to γmean and γ1%, the parameter ΔD{sub 50} performs worse as a discriminator in all cases.

60 APPLIED LIFE SCIENCES↗

Object detectability at increased ambient lighting conditions

Under typical dark conditions encountered in diagnostic reading rooms, a reader's pupils will contract and dilate as the visual focus intermittently shifts between the high luminance display and the darker background wall, resulting in increased visual fatigue and the degradation of diagnostic performance. A controlled increase of ambient lighting may, however, reduce the severity of these pupillary adjustments by minimizing the difference between the luminance level to which the eyes adapt while viewing an image (L{sub adp}) and the luminance level of diffusely reflected light from the area surrounding the display (L{sub s}). Although ambient lighting in reading rooms has conventionally been kept at a minimum to maintain the perceived contrast of film images, proper Digital Imaging and Communications in Medicine (DICOM) calibration of modern medical-grade liquid crystal displays can compensate for minor lighting increases with very little loss of image contrast. This paper describes two psychophysical studies developed to evaluate and refine optimum reading room ambient lighting conditions through the use of observational tasks intended to simulate real clinical practices. The first study utilized the biologic contrast response of the human visual system to determine a range of representative L{sub adp} values for typical medical images. Readers identified low contrast horizontal objects in circular foregrounds of uniform luminance (5, 12, 20, and 30 cd/m{sup 2}) embedded within digitized mammograms. The second study examined the effect of increased ambient lighting on the detection of subtle objects embedded in circular foregrounds of uniform luminance (5, 12, and 35 cd/m{sup 2}) centered within a constant background of 12 cd/m{sup 2} luminance. The images were displayed under a dark room condition (1 lux) and an increased ambient lighting level (50 lux) such that the luminance level of the diffusely reflected light from the background wall was approximately equal to the image L{sub adp} value of 12 cd/m{sup 2}. Results from the first study demonstrated that observer true positive and false positive detection rates and true positive detection times were considerably better while viewing foregrounds at 12 and 20 cd/m{sup 2} than at the other foreground luminance levels. Results from the second study revealed that under increased room illuminance, the average true positive detection rate improved a statistically significant amount from 39.3% to 55.6% at 5 cd/m{sup 2} foreground luminance. Additionally, the true positive rate increased from 46.4% to 56.6% at 35 cd/m{sup 2} foreground luminance, and decreased slightly from 90.2% to 87.5% at 12 cd/m{sup 2} foreground luminance. False positive rates at all foreground luminance levels remained approximately constant with increased ambient lighting. Furthermore, under increased room illuminance, true positive detection times declined at every foreground luminance level, with the most considerable decrease (approximately 500 ms) at the 5 cd/m{sup 2} foreground luminance. The first study suggests that L{sub adp} of typical mammograms lies between 12 and 20 cd/m{sup 2}, leading to an optimum reading room illuminance of approximately 50-80 lux. Findings from the second study provide psychophysical evidence that ambient lighting may be increased to a level within this range, potentially improving radiologist comfort, without deleterious effects on diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Orthogonal chemical genomics approaches reveal genomic targets for increasing anaerobic chemical tolerance in Zymomonas mobilis

Genetically engineered microbes have the potential to increase efficiency in the bioeconomy by overcoming growth-limiting production stress. Screens of gene perturbation libraries against production stressors can identify high-value engineering targets, but follow-up experiments needed to guard against false positives are slow and resource-intensive. In principle, the use of orthogonal gene perturbation approaches could increase recovery of true positives over false positives because the strengths of one technique compensate for the weaknesses of the other, but, in practice, two parallel screens are rarely performed at the genome scale. Here, we screen genome-scale CRISPRi (CRISPR interference) knockdown and transposon insertion libraries of the bioenergy-relevant Alphaproteobacterium, Zymomonas mobilis, against growth inhibitors commonly found in deconstructed plant material. Integrating data from the two gene perturbation techniques, we established an approach for defining engineering targets with high specificity. This allowed us to identify all known genes in the cytochrome bc1 and cytochrome c synthesis pathway as potential targets for engineering resistance to phenolic acids under anaerobic conditions, a subset of which we validated using precise gene deletions. Strikingly, this finding is specific to the cytochrome bc1 and cytochrome c pathway and does not extend to other branches of the electron transport chain. We further show that exposure of Z. mobilis to ferulic acid causes substantial remodeling of the cell envelope proteome, as well as the downregulation of TonB-dependent transporters. Our work provides a generalizable strategy for identifying high-value engineering targets from gene perturbation screens that is broadly applicable.

CRISPRi↗

Creation of a Robust and Generalizable Machine Learning Classifier for Patient Ventilator Asynchrony

Background: As healthcare increasingly digitizes, streaming waveform data is being made available from an variety of sources, but there still remains a paucity of performant clinical decision support systems. For example, in the intensive care unit (ICU) existing automated alarm systems typically rely on simple thresholding that result in frequent false positives. Recurrent false positive alerts create distrust of alarm mechanisms that can be directly detrimental to patient health. To improve patient care in the ICU, we need alert systems that are both pervasive, and accurate so as to be informative and trusted by providers. Objective: We aimed to develop a machine learning-based classifier to detect abnormal waveform events using the use case of mechanical ventilation waveform analysis, and the detection of harmful forms of ventilation delivery to patients. We specifically focused on detecting injurious subtypes of patient-ventilator asynchrony (PVA).Methods: Using a dataset of breaths recorded from 35 different patients, we used machine learning to create computational models to automatically detect, and classify two types of injurious PVA, double trigger asynchrony (DTA), breath stacking asynchrony (BSA). We examined the use of synthetic minority over-sampling technique (SMOTE) to overcome class imbalance problems, varied methods for feature selection, and use of ensemble methods to optimize the performance of our model. Results: We created an ensemble classifier that is able to accurately detect DTA at a sensitivity/specificity of 0.960/0.975, BSA at sensitivity/specificity of 0.944/0.987, and non-PVA events at sensitivity/specificity of .967/.980. Conclusions: Our results suggest that it is possible to create a high-performing machine learning-based model for detecting PVA in mechanical ventilator waveform data in spite of both intra-patient, and inter-patient variability in waveform patterns, and the presence of clinical artifacts like cough and suction procedures. Our work highlights the importance of addressing class imbalance in clinical data sets, and the combined use of statistical methods and expert knowledge in feature selection.

97 MATHEMATICS AND COMPUTING↗

Methods for threshold determination in multiplexed assays

Methods for determination of threshold values of signatures comprised in an assay are described. Each signature enables detection of a target. The methods determine a probability density function of negative samples and a corresponding false positive rate curve. A false positive criterion is established and a threshold for that signature is determined as a point at which the false positive rate curve intersects the false positive criterion. A method for quantitative analysis and interpretation of assay results together with a method for determination of a desired limit of detection of a signature in an assay are also described.

47 OTHER INSTRUMENTATION↗

Magnetic Resonance–Based Automatic Air Segmentation for Generation of Synthetic Computed Tomography Scans in the Head Region

Purpose: To incorporate a novel imaging sequence for robust air and tissue segmentation using ultrashort echo time (UTE) phase images and to implement an innovative synthetic CT (synCT) solution as a first step toward MR-only radiation therapy treatment planning for brain cancer. Methods and Materials: Ten brain cancer patients were scanned with a UTE/Dixon sequence and other clinical sequences on a 1.0 T open magnet with simulation capabilities. Bone-enhanced images were generated from a weighted combination of water/fat maps derived from Dixon images and inverted UTE images. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating segmentation errors (true-positive rate, false-positive rate, and Dice similarity indices using CT simulation (CT-SIM) as ground truth. The synCTs were generated using a voxel-based, weighted summation method incorporating T2, fluid attenuated inversion recovery (FLAIR), UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized Hounsfield unit (HU) differences between synCT and CT-SIM. A dosimetry study was conducted, and differences were quantified using γ-analysis and dose-volume histogram analysis. Results: On average, true-positive rate and false-positive rate for the CT and MR-derived air masks were 80.8% ± 5.5% and 25.7% ± 6.9%, respectively. Dice similarity indices values were 0.78 ± 0.04 (range, 0.70-0.83). Full field of view MAE between synCT and CT-SIM was 147.5 ± 8.3 HU (range, 138.3-166.2 HU), with the largest errors occurring at bone–air interfaces (MAE 422.5 ± 33.4 HU for bone and 294.53 ± 90.56 HU for air). Gamma analysis revealed pass rates of 99.4% ± 0.04%, with acceptable treatment plan quality for the cohort. Conclusions: A hybrid MRI phase/magnitude UTE image processing technique was introduced that significantly improved bone and air contrast in MRI. Segmented air masks and bone-enhanced images were integrated into our synCT pipeline for brain, and results agreed well with clinical CTs, thereby supporting MR-only radiation therapy treatment planning in the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate-Specific Antigen Velocity Before and After Elimination of Factors That Can Confound the Prostate-Specific Antigen Level

Purpose: Prostate-specific antigen (PSA) velocity, like PSA level, can be confounded. In this study, we estimated the impact that confounding factors could have on correctly identifying a patient with a PSA velocity >2 ng/ml/y. Methods and Materials: Between 2006 and 2010, a total of 50 men with newly diagnosed PC comprised the study cohort. We calculated and compared the false-positive and false-negative PSA velocity >2 ng/ml/y rates for all men and those with low-risk disease using two approaches to calculate PSA velocity. First, we used PSA values obtained within 18 months of diagnosis; second, we used values within 18 months of diagnosis, substituting the prebiopsy PSA for a repeat, nonconfounded PSA that was obtained using the same assay and without confounders. Results: Using PSA levels pre-biopsy, 46% of all men had a PSA velocity >2 ng/ml/y; whereas this value declined to 32% when substituting the last prebiopsy PSA for a repeat, nonconfounded PSA using the same assay and without confounders. The false-positive rate for PSA velocity >2 ng/ml/y was 43% as compared with a false-negative rate of PSA velocity >2 ng/ml/y of 11% (p = 0.0008) in the overall cohort. These respective values in the low-risk subgroup were 60% and 16.7% (p = 0.09). Conclusion: This study provides evidence to explain the discordance in cancer-specific outcomes among groups investigating the prognostic significance of PSA velocity >2 ng/ml/y, and highlights the importance of patient education on potential confounders of the PSA test before obtaining PSA levels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Kepler's multiple planet candidates. III. Light curve analysis and announcement of hundreds of new multi-planet systems

The Kepler mission has discovered more than 2500 exoplanet candidates in the first two years of spacecraft data, with approximately 40% of those in candidate multi-planet systems. The high rate of multiplicity combined with the low rate of identified false positives indicates that the multiplanet systems contain very few false positive signals due to other systems not gravitationally bound to the target star. False positives in the multi-planet systems are identified and removed, leaving behind a residual population of candidate multi-planet transiting systems expected to have a false positive rate less than 1%. We present a sample of 340 planetary systems that contain 851 planets that are validated to substantially better than the 99% confidence level; the vast majority of these have not been previously verified as planets. We expect ∼two unidentified false positives making our sample of planet very reliable. We present fundamental planetary properties of our sample based on a comprehensive analysis of Kepler light curves, ground-based spectroscopy, and high-resolution imaging. Since we do not require spectroscopy or high-resolution imaging for validation, some of our derived parameters for a planetary system may be systematically incorrect due to dilution from light due to additional stars in the photometric aperture. Nonetheless, our result nearly doubles the number verified exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvements of pre-emptive identification of particle accelerator failures using binary classifiers and dimensionality reduction

In this paper we look at the properties of the Spallation Neutron Source (SNS) Differential Beam Current Monitor (DCM) data and various methods of data transformation to improve pre-emptive detection of machine trips. In this study, the foundation of the approach is the analysis of new underlying data and understanding various properties with the goal of faster classification, higher precision and higher recall with the aim to reduce false positives as low as required. The result of the research presented in this paper are a binary classifier capable of predicting accelerator failures with millisecond classification time, 96% precision, 58% true positive and 0% false positive rate and optimization techniques enabling real-time implementations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The APOGEE Spectroscopic Survey of Kepler planet hosts: Feasibility, efficiency, and first results

The Kepler mission has yielded a large number of planet candidates from among the Kepler Objects of Interest (KOIs), but spectroscopic follow-up of these relatively faint stars is a serious bottleneck in confirming and characterizing these systems. We present motivation and survey design for an ongoing project with the Sloan Digital Sky Survey III multiplexed Apache Point Observatory Galactic Evolution Experiment (APOGEE) near-infrared spectrograph to monitor hundreds of KOI host stars. We report some of our first results using representative targets from our sample, which include current planet candidates that we find to be false positives, as well as candidates listed as false positives that we do not find to be spectroscopic binaries. With this survey, KOI hosts are observed over ∼20 epochs at a radial velocity (RV) precision of 100–200 m s{sup −1}. These observations can easily identify a majority of false positives caused by physically associated stellar or substellar binaries, and in many cases, fully characterize their orbits. We demonstrate that APOGEE is capable of achieving RV precision at the 100–200 m s{sup −1} level over long time baselines, and that APOGEE’s multiplexing capability makes it substantially more efficient at identifying false positives due to binaries than other single-object spectrographs working to confirm KOIs as planets. These APOGEE RVs enable ancillary science projects, such as studies of fundamental stellar astrophysics or intrinsically rare substellar companions. The coadded APOGEE spectra can be used to derive stellar properties (T{sub eff}, logg) and chemical abundances of over a dozen elements to probe correlations of planet properties with individual elemental abundances.

79 ASTRONOMY AND ASTROPHYSICS↗