Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “equivalent circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effect of Nanoscale Ce 0.8 Gd 0.2 O 2–δ Infiltrant and Steam Content on Ni–(Y 2 O 3 ) 0.08 (ZrO 2 ) 0.92 Fuel Electrode Degradation during High-Temperature Electrolysis

Studies of Ni–yttria-stabilized zirconia (YSZ) fuel electrode degradation mechanisms in solid oxide electrolysis cells (SOECs) are complicated by the different possible Ni–YSZ microstructures and compositions, and the variations in the H 2 /H 2 O ratio encountered in an electrolysis stack. Here, in this study, we describe a life testing scheme aimed at providing survey results on degradation as a function of the H 2 O–H 2 composition, with life tests carried out at five different steam contents from 90% to 10%. A Ni–YSZ-supported symmetric cell geometry is employed both with and without infiltrated nanoscale gadolinia-doped ceria (GDC). Impedance spectroscopy is utilized to observe changes in electrochemical characteristics during the life test, and a transmission-line-based equivalent circuit is used to model the data. Post-test electrode microstructures were observed. The results suggest that the GDC infiltrant reduces the electrode polarization resistance and provides more stable electrode polarization over a range of conditions.

08 HYDROGEN↗

Laboratory Electrical Conductivity of Marine Gas Hydrate

Methane hydrate was synthesized from pure water ice and flash frozen seawater, with varying amounts of sand or silt added. Electrical conductivity was determined by impedance spectroscopy, using equivalent circuit modeling to separate the effects of electrodes and to gain insight into conduction mechanisms. Silt and sand increase the conductivity of pure hydrate; we infer by contaminant NaCl contributing to conduction in hydrate, to values in agreement with resistivities observed in well logs through hydrate–saturated sediment. The addition of silt and sand lowers the conductivity of hydrate synthesized from seawater by an amount consistent with Archie's law. Here, all samples were characterized using cryogenic scanning electron microscopy and energy dispersive spectroscopy, which show good connectivity of salt and brine phases. Electrical conductivity measurements of pure hydrate and hydrate mixed with silt during pressure–induced dissociation support previous conclusions that sediment increases dissociation rate.

58 GEOSCIENCES↗

Electrical Properties of Carbon Dioxide Hydrate: Implications for Monitoring CO 2 in the Gas Hydrate Stability Zone

CO 2 and CH 4 clathrate hydrates are of keen interest for energy and carbon cycle considerations. While both typically form on Earth as cubic structure I (sI), we find that pure CO 2 hydrate exhibits over an order of magnitude higher electrical conductivity ( σ ) than pure CH 4 hydrate at geologically relevant temperatures. In this study, the conductivity was obtained from frequency-dependent impedance ( Z ) measurements made on polycrystalline CO 2 hydrate (CO 2 ·6.0 ± 0.2H 2 O by methods here) with 25% gas-filled porosity, compared with CH 4 hydrate (CH 4 ·5.9H 2 O) formed and measured in the same apparatus and exhibiting closely matching grain characteristics. The conductivity of CO 2 hydrate is 6.5 × 10 –4 S/m at 273K with an activation energy ( E a ) of 46.5 kJ/mol at 260–281 K, compared with ~5 × 10 –5 S/m and 34.8 kJ/m for CH 4 hydrate. Equivalent circuit modeling indicates that different pathways govern conduction in CO 2 versus CH 4 hydrate. Results show promise for use of electromagnetic methods in monitoring CO 2 hydrate formation in certain natural settings or in CO 2 /CH 4 exchange efforts.

58 GEOSCIENCES↗

Microstructural impacts on ionic conductivity of oxide solid electrolytes from a combined atomistic-mesoscale approach

Abstract Although multiple oxide-based solid electrolyte materials with intrinsically high ionic conductivities have emerged, practical processing and synthesis routes introduce grain boundaries and other interfaces that can perturb primary conduction channels. To directly probe these effects, we demonstrate an efficient and general mesoscopic computational method capable of predicting effective ionic conductivity through a complex polycrystalline oxide-based solid electrolyte microstructure without relying on simplified equivalent circuit description. We parameterize the framework for Li 7- x La 3 Zr 2 O 12 (LLZO) garnet solid electrolyte by combining synthetic microstructures from phase-field simulations with diffusivities from molecular dynamics simulations of ordered and disordered systems. Systematically designed simulations reveal an interdependence between atomistic and mesoscopic microstructural impacts on the effective ionic conductivity of polycrystalline LLZO, quantified by newly defined metrics that characterize the complex ionic transport mechanism. Our results provide fundamental understanding of the physical origins of the reported variability in ionic conductivities based on an extensive analysis of literature data, while simultaneously outlining practical design guidance for achieving desired ionic transport properties based on conditions for which sensitivity to microstructural features is highest. Additional implications of our results are discussed, including a possible connection between ion conduction behavior and dendrite formation.

25 ENERGY STORAGE↗

Acceptor dopant mediated electrical property modification in Bi0.5Na0.5TiO3-based piezoceramic

The effect of Mn and Fe dopants on the electromechanical and electrochemical properties of 0.88[Bi 0.5 Na 0.5 ]TiO 3 –0.08[Bi 0.5 K 0.5 ]TiO 3 –0.04[Bi 0.5 Li 0.5 ]TiO 3 piezoceramic is investigated with particular emphasis on complex impedance in the temperature range from 450 to 600 °C. The impedance spectra have been simulated with equivalent circuits in order to extract bulk and grain boundary characteristics and to determine activation energies of conduction. Mn and Fe dopants considerably enhance the mechanical quality factor and decrease the dielectric loss compared to the undoped composition. Mn doping leads to dramatically higher resistivity in the bulk and a modest increase in the bulk activation energy. On the other hand, conductivity increases dramatically via Fe doping with a significant lowering of activation energy in the bulk and corresponding raising of the activation energy at grain boundaries in comparison to Mn-doped and undoped ceramic. The bulk conductivity of Fe-doped piezoceramic reaches as high as 0.01 S cm -1 at 600 °C.

36 MATERIALS SCIENCE↗

Design and testing of a high perveance sheet beam electron gun

This paper presents the design, prototype engineering, and initial testing of a relatively low-voltage, high aspect ratio electron gun for versatile pulsed power applications. The sheet beam, diode electron gun is designed for (23–25) kV voltage and 6 µA/V1.5, as is required for x-band klystron, as a part of a compact Klylac delivering electron beam energy in the MeV range. The gun prototype was engineered, built, and tested using a Scandinova M1-0.5 modulator. Beam loss on the anode aperture is evaluated from transient waveforms and equivalent circuit modeling.

Instruments & Instrumentation↗

A model for K-shell x-ray yield from magnetic implosions at Sandia's Z machine

A zero-dimensional magnetic implosion model with a coupled equivalent circuit for the description of an imploding nested wire array or gas puff is presented. Circuit model results have been compared with data from imploding stainless steel wire arrays, and good agreement has been found. The total energy coupled to the load, Ej×B, has been applied to a simple semi-analytic K-shell yield model, and excellent agreement with previously reported K-shell yields across all wire array and gas puff platforms is seen. Trade space studies in implosion radius and mass have found that most platforms operate near the predicted maximum yield. In some cases, the K-shell yield may be increased by increasing the mass or radius of the imploding array or gas puff.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic simulation of a 50 mTorr capacitively coupled argon discharge over a range of frequencies and comparison to experiments

The effect of driving frequency in the range of 13.56–73 MHz on electron energy distribution and electron heating modes in a 50 mTorr capacitively coupled argon plasma discharge is studied using 1D-3V particle-in-cell simulations. Calculated electron energy probability functions exhibit three distinct “temperatures” for low-, mid-, and high-energy electrons at all the studied driving frequencies. When compared to published experimental data, the calculated probability functions show a reasonable agreement for the energy range resolved in the measurements (about 2–10 eV). Discrepancies due to limitations in experimental energy resolution outside this range lead to differences between computational and experimental values of the electron number density determined from the distribution functions, and the predicted effective electron temperature is within 25% of experimental values. The impedance of the discharge is interpreted in terms of a homogeneous equivalent circuit model, and the driving frequency dependence of the inferred combined sheath thickness is found to obey a known, theoretically derived, power law. The average power transferred from the field to the electrons (electron heating) is computed, and a region of negative heating near the sheath edge, particularly at higher driving frequencies, is identified. Analysis of the electron momentum equation shows that electron inertia, which on temporal averaging would be zero in a linear regime, is responsible for negative values of power deposition near the sheath edge at high driving frequencies due to the highly nonlinear behavior of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Modeling of Tandem Photovoltaics: A Yearlong Outdoor Degradation Analysis of a Ga⁢As//Si Minimodule

We present a performance modeling and degradation analysis framework for tandem photovoltaic modules, building upon established procedures for crystalline silicon devices and adapting them to account for the spectral sensitivity of multijunction technologies. The methodology employs filter criteria to select outdoor measurements close to standard test conditions (STC) under stable spectral and ambient conditions, followed by normalization of power production data with corrections for temperature, irradiance, and precipitable water vapor. We demonstrate this framework using a mechanically stacked four-terminal gallium arsenide (Ga⁢As) // silicon (Si) tandem solar minimodule deployed outdoors from October 2019 to January 2021 in Golden, Colorado, USA. We determined degradation rates of −4.1 ±0.2%/year for the Ga⁢As subcell and −2.5 ±0.9%/year for the Si subcell, with analysis of individual performance metrics indicating that packaging degradation, particularly delamination, was the dominant failure mode. Simulations using PVcircuit, an open-source equivalent-circuit solver, confirmed these findings. The presented methodology provides a reproducible foundation for performance modeling and degradation analysis of emerging tandem technologies.

14 SOLAR ENERGY↗

Capacitive response of biological membranes

We present a minimal model to analyze the capacitive response of a biological membrane subjected to a step voltage via blocking electrodes. Through a perturbative analysis of the underlying electrolyte transport equations, we show that the leading-order relaxation of the transmembrane potential is governed by a capacitive timescale, τ_{C}=λ_{D}L/D(2+Γδ^{M}/L/4+Γδ^{M}/λ_{D}), where λ_{D} is the Debye screening length, L is the electrolyte width, Γ is the ratio of the permittivity of the electrolyte to the membrane, δ^{M} is the membrane thickness, and D is the ionic diffusivity. This timescale is considerably shorter than the traditional RC timescale λ_{D}L/D for a bare electrolyte due to the membrane's low permittivity and finite thickness. Beyond the linear regime, however, salt diffusion in the bulk electrolyte drives a secondary, nonlinear relaxation process of the transmembrane potential over a longer timescale τ_{L}=L^{2}/4π^{2}D. A simple equivalent-circuit model accurately captures the linear behavior, and the perturbation expansion remains applicable across the entire range of observed physiological transmembrane potentials. Together, these findings underscore the importance of the faster capacitive timescale and nonlinear effects on the bulk diffusion timescale in determining transmembrane potential dynamics for a range of biological systems.

Farhadi, Jafar↗

Spatiotemporal dynamics of ionic reorganization near biological membrane interfaces

Electrical signals in excitable cells involve spatially localized ionic fluxes through ion channels and pumps on cellular lipid membranes. Common approaches to understand how these fluxes spread assume that the membrane and the surrounding electrolyte comprise an equivalent circuit of capacitors and resistors, which ignores the localized nature of transmembrane ion transport, the resulting ionic gradients and electric fields, and their spatiotemporal relaxation. Here, we consider a model of localized ion pumping across a lipid membrane, and use theory and simulation to investigate how the electrochemical signal propagates spatiotemporally in and out of plane along the membrane. The localized pumping generates long-ranged electric fields with three distinct scaling regimes along the membrane: a constant potential near-field region, an intermediate monopolar region, and a far-field dipolar region. Upon sustained pumping, the monopolar region expands radially in plane with a steady speed that is enhanced by the dielectric mismatch and the finite thickness of the lipid membrane. For unmyelinated lipid membranes in physiological settings, we find remarkably fast propagation speeds of ∼ 40 m / s , allowing faster ionic reorganization compared to bare diffusion. Together, our paper shows that transmembrane ionic fluxes induce transient long-ranged electric fields in electrolyte solutions, which may play hitherto unappreciated roles in biological signaling. Published by the American Physical Society 2025

Row, Hyeongjoo (ORCID:000000033623512X)↗

Greybox Thermal Parameter Identification of Electric Machine Stators

The parameters of electric machine thermal equivalent circuit networks are difficult to predict due to material and manufacturing uncertainties. In this paper, a Greybox system identification approach is used to identify parameters of electric machine stator lumped parameter thermal networks (LPTNs). LPTNs provide a low order, computationally efficient, dynamic model of temperatures at specific locations. Second and third order LPTN model structures are defined as state space equations with stator thermal parameters to be identified. To test the Greybox electric machine stator thermal system identification, five stator motorette prototypes were constructed with controlled variations in slot fill and slot liner thickness. The variation in the motorette thermal parameters and thermal time constants are detected using the Greybox identification. Special attention is given to the impact of sampling rate and Greybox data record length on parameter estimation accuracy.

33 ADVANCED PROPULSION SYSTEMS↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Impedance Emulation Control of Wave Energy Converters

Modeling and control of wave energy conversion (WEC) systems for maximum power extraction is challenging due to complex multiphysics that include fluids, mechanics, and machine drives. To uncover an intuitive model that clearly depicts WEC system operation, we utilize a force-current equivalent circuit framework which then enables us to design an impedance emulation control strategy. To provide context for our framework, we focus on a standard reference model-3 (RM3) point absorber device coupled to a permanent magnet synchronous generator. After the proposed extremum seeking controller is computed, we experimentally validate its performance on a platform that consists of two back-to-back connected inverters that emulate the WEC system.

wave energy conversion, impedance emulation, machi↗

Thermal Analysis of a Polypropylene Capacitor for Resonant Tuning Networks in WPT Applications

This study presents the thermal analysis of polypropylene capacitors operating at high frequencies and high currents used in the resonant tuning networks for electric vehicle (EV) wireless charging systems. The thermal analysis and performance results of the CELEM polypropylene capacitors are presented at different currents for a polyphase wireless power transfer (WPT) system while the study can be expanded to other capacitors by different manufacturers. Thermal equivalent circuit of the capacitor is derived and required cold plate size and design calculations are conducted by modeling the polypropene capacitor in MATLAB. The polypropene capacitor's finite element analysis (FEA) model is developed using COMSOL Multiphysics simulation software, and the thermal characteristics and analysis of the capacitor are presented in this paper.

Aktas, Ahmet↗

Power Layout Design of a GaN HEMTs-Based High-Power High-Efficiency Three-Level ANPC Inverter for 800 V DC Bus System

Multiple commutation paths exist for switching devices in a three-level active neutral point clamped (3L-ANPC) inverter operation based on the selected switching state and current direction. In addition, the capacitive coupling path of the nonswitching device is a key design aspect for enabling high voltage and high current operation of gallium nitride (GaN) switches in 3L-ANPC topology. A comprehensive study of the switching transient events of inner, outer, and clamping devices of 3L-ANPC is presented in this article. The commutation mechanisms for worst-case transient voltage overshoots (TVOs) are identified. A simplified equivalent circuit model is presented to determine the design criteria for the power layout structure's parasitic inductances. A power layout strategy satisfying the design criteria is then proposed using an insulated metal substrate power printed circuit board (PCB) to enable efficient high-power operation. The proposed design minimizes the commutation and capacitive coupling path inductances to 6 nH and 11.5 nH, respectively. This enables the fast switching operation of GaN HEMTs at 800 V dc, 36 A with a low TVO of 31% verified through experimental three-level double pulse test results. Experimental evaluation of a three-phase 3L-ANPC hardware prototype based on the proposed power layout shows 99% efficiency at 800 V, 9.5 kVA and 50 kHz switching frequency. The proposed design achieves a low case-to-ambient thermal resistance of 2.3 °C/W.

42 ENGINEERING↗

Linear Solvers for Collector Systems of Generalized Large-scale Inverter-Based Resources

Collector systems for inverter-based resources (IBRs) are typically represented by equivalent circuits for electromagnetic transient (EMT) simulations. Recent studies have revealed that modeling a detailed collector system is essential to accurately represent the behavior of IBRs, especially when dealing with partial tripping during external disturbances. However, there are several challenges in simulating a detailed EMT model of a collector system due to the time required to simulate such systems. Thus, this paper investigates the modeling of a detailed collector system, taking into account its configuration and components as defined in IEEE standard 2800. The configurations include the collector systems of generalized large-scale IBR plants. The components include the main IBR transformer, collector bus, and feeders with lines and/or cables. The EMT model of the collector system is represented by differential algebraic equations (DAEs) that are discretized to form linear equations that are solved using linear solvers. In this paper, linear solvers are proposed based on the Schur complement method, which are utilized for simulation of the EMT model of collector systems of generalized large-scale IBRs to accelerate simulation speed while maintaining the accuracy of the results. The proposed solvers are verified by comparing the performance to that of linear solvers provided in MATLAB.

Choi, Jongchan↗

Transient Stability Analysis of Direct Droop-Controlled Grid-Forming Inverter with Current Clipping as Current Limiting Control

This paper investigates the transient stability of the direct droop-controlled grid-forming (GFM) inverter which employs the current clipping-based approach for overcurrent limitation. An equivalent circuit model of the direct-droop GFM inverter with current clipping is developed for this purpose. It is shown that during overcurrent conditions, the GFM inverter with current clipping acts as a voltage source with a virtual resistance behind the inverter filters. To compute the parameters of this virtual resistance an analytical expression is given in the paper. Then utilizing the developed circuit, a criteria to exit current limiting during post-fault conditions is given. The developed analytical approaches are then validated through electromagnetic transient (EMT) simulation results in PSCAD software and finally concluding remarks are drawn.

Mohiuddin, Sheik Mohammad↗