Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “epoxy composite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Influence of sizing concentration on strength, stiffness, and porosity in textile grade carbon fiber (TCF)-Epoxy composites: Revealing inverse trends

The effect of fiber sizing (i.e., surface treatment) concentration (0 %, 1.36 %, 1.52 %, 1.94 %, and 2.13 %) on the mechanical properties (tensile, flexural, interlaminar shear strength (ILSS), and low velocity impact) of textile grade carbon fiber (TCF)-epoxy composite is examined. An inverse relationship between the strength and stiffness of the composite is observed with increased sizing concentration. The root mean square (RMS) roughness of the fiber surface increased from 17.8 nm (unsized) to 22.7 nm with 2.13 % sizing concentration. It was found that the tensile strength increased by 131 % from 221.4 ± 18.5 MPa (unsized) to 510.8 ± 28.05 MPa (for 1.36 % sizing) and further by 155 %–563.7 ± 14.95 MPa at 2.13 % sizing. On the contrary, the stiffness is initially increased by 126 % from 33.52 ± 7.80 GPa (unsized) to 75.9 ± 3.21 GPa (for 1.36 % sizing) but reduced with further increase in the sizing concentration. A single fiber pull-out test is simulated using the finite element method to validate the reverse trend in strength and stiffness. The varying sizing concentration is simulated by introducing an interface of varying thickness between fibers and matrix. Simulation results confirm that a thicker interface, corresponding to a higher sizing concentration, decreases interfacial shear stress, enhancing material strength while decreasing stiffness. The reverse trend in strength and stiffness with the sizing concentration aligns with experimental observations. In conclusion, the present study emphasizes the importance of sizing concentration for mechanical properties and provide a design criterion for customized high-strength and high-stiffness applications.

Porosity↗

Hygrothermal damage mechanisms in graphite-epoxy composites

T300/5209 and T300/5208 graphite epoxy laminates were studied experimentally and analytically in order to: (1) determine the coupling between applied stress, internal residual stress, and moisture sorption kinetics; (2) examine the microscopic damage mechanisms due to hygrothermal cycling; (3) evaluate the effect of absorbed moisture and hygrothermal cycling on inplane shear response; (4) determine the permanent loss of interfacial bond strength after moisture absorption and drying; and (5) evaluate the three dimensional stress state in laminates under a combination of hygroscopic, thermal, and mechanical loads. Specimens were conditioned to equilibrium moisture content under steady exposure to 55% or 95% RH at 70 C or 93 C. Some specimens were tested subsequent to moisture conditioning and 100 cycles between -54 C and either 70 C or 93 C.

Crossman, F. W.↗

Increased fracture toughness of graphite-epoxy composites through intermittent interlaminar bonding

Intermittent interlaminar bonding, which can lead to a large increase in the fracture surface area, was achieved through the introduction of thin perforated Mylar between the layers of a multi-layer continuous-filament graphite-epoxy composite. For the best optimum condition included in this study, fracture toughness was increased from about 100 kJ/sq m for untreated specimens to an average of about 500 kJ/sq m, while tensile strength dropped from 500 MPa to 400 MPa, and elastic modulus remained the same at about 75 GPa. An approximate analysis is presented to explain the observed improvement in toughness.

Felbeck, D. K.↗

Interphase tailoring in graphite-epoxy composites

The fiber-matrix interphase in graphite fiber-epoxy matrix composites is presently modified through the electrodeposition of a coating of the polymer poly(styrene-comaleic anhydride), or 'SMA' on the graphite fibers; optimum conditions have been established for the achievement of the requisite thin, uniform coatings, as verified by SEM. A single-fiber composite test has shown the SMA coating to result in an interfacial shear strength to improve by 50 percent over commercially treated fibers without sacrifice in impact strength. It is suggested that the epoxy resin's superior penetration into the SMA interphase results in a tougher fiber/matrix interface which possesses intrinsic energy-absorbing mechanisms.

Subramanian, R. V.↗

Large fracture toughness boron-epoxy composites

The high tensile strengths of strong interfacial bonding may be combined with the large fracture toughness of weak interfacial bonding in brittle fiber/brittle matrix composites by intermittently coating the filaments before layup so as to have random alternate weak and strong regions. Appropriate coating materials enable Cook-Gordon Mode I interfacial debonding to take place, which produces very long pull-out lengths with an associated large contribution to toughness. Unidirectional boron-epoxy composites have been so made which have toughnesses greater than 200 kJ/sq m while retaining rule of mixtures tensile strengths. Similar trends have been observed for crossply layups.

Atkins, A. G.↗

Laser Surface Preparation of Epoxy Composites for Secondary Bonding: Optimization of Ablation Depth

Surface preparation has been identified as one of the most critical aspects of attaining predictable and reliable adhesive bonds. Energetic processes such as laser ablation or plasma treatment are amenable to automation and are easily monitored and adjusted for controlled surface preparation. A laser ablation process was developed to accurately remove a targeted depth of resin, approximately 0.1 to 20 micrometers, from a carbon fiber reinforced epoxy composite surface while simultaneously changing surface chemistry and creating micro-roughness. This work demonstrates the application of this process to prepare composite surfaces for bonding without exposing or damaging fibers on the surface. Composite panels were prepared in an autoclave and had a resin layer approximately 10 micrometers thick above the fiber reinforcement. These composite panels were laser surface treated using several conditions, fabricated into bonded panels and hygrothermally aged. Bond performance of aged, experimental specimens was compared with grit blast surface treated specimens using a modified double cantilever beam test that enabled accelerated saturation of the specimen with water. Comparison of bonded specimens will be used to determine how ablation depth may affect average fracture energies and failure modes.

Palmieri, Frank L.↗

Flight service evaluation of Kevlar-49 epoxy composite panels in wide-bodied commercial transport aircraft

Kevlar-49 fairing panels, installed as flight service components on three l-1011's, were inspected after 8 years service. The fairings had accumulated a total of 62,000 hours, with one ship set having 20,850 hours service. Kevlar-49 components were found to be performing satisfactorily in service with no major problems. The only defects noted were minor impact damage, a few minor disbonds and a minor degree of fastener hole fraying and elongation. The service history to date indicates that Kevlar-49 epoxy composite materials have satisfactory service characteristics for use in aircraft secondary structures.

Stone, R. H.↗

Flight service evaluation of Kevlar-49 epoxy composite panels in wide-bodies commercial transport aircraft

Kevlar-49 fairing panels, installed as flight service components on three L-1011s, were inspected after 9 years of service. There are six Kevlar-49 panels on each aircraft: a left hand and right hand set of a wing body sandwich fairing; a solid laminate under wing fillet panel; and a 422 K (300 F) service aft engine fairing. The fairings have accumulated a total of 70,000 hours, with one ship set having over 24,000 hours service. The Kevlar-49 components were found to be performing satisfactorily in service with no major problems, or any condition requiring corrective action. The only defects noted were minor impact damage, a few minor disbonds and a minor degree of fastener hole fraying and elongation. These are for the most part comparable to damage noted on fiberglass fairings. The service history to date indicates that Kevlar-49 epoxy composite materials have satisfactory service characteristics for use in aircraft secondary structure.

Stone, R. H.↗

Flight service evaluation of kevlar-49 epoxy composite panels in wide-bodied commercial transport aircraft: Flight service report

Kevlar-49 fairing panels, installed as flight service components on three L-1011s, were inspected after 7 years service. There are six Kevlar-49 panels on each aircraft: a left hand and right hand set of a wing-body sandwich fairing; a slid laminate under-wing fillet panel; and a 422 K service aft engine fairing. The three L-1011s include one each in service with Eastern, Air Canada, and TWA. The fairings have accumulated a total of 52,500 hours, with one ship set having 17.700 hours service. The inspections were conducted at the airlines' major maintenance bases with the participation of Lockheed Engineering. The Kevlar-49 components were found to be performing satisfactorily in service with no major problems or any condition requiring corrective action. The only defects noted were minor impact damage and a minor degree of fastener hole fraying and elongation. These are for the most part comparable to damage noted on fiberglass fairings. The service history to date indicates that Kevlar-49 epoxy composite materials have satisfactory service characteristics for use in aircraft secondary structure.

Stone, R. H.↗

Flight service evaluation of Kevlar-49 epoxy composite panels in wide-bodied commercial transport aircraft

Kevlar-49 fairing panels, installed as flight service components on three L-1011s, were inspected after 10 years of service. There are six Kevlar-49 panels on each aircraft: a left-hand and right-hand set of a wing-body sandwich fairing; a solid laminate under-wing fillet panel; and a 422 K (300 F) service aft engine fairing. The three L-1011s include one each in service with Eastern, Air Canada, and TWA. The fairings have accumulated a total of 79,568 hours, with one ship set having nearly 28,000 hours service. The inspections were conducted at the airlines' major maintenance bases with the participation of Lockheed Engineering. The Kevlar-49 components were found to be performing satisfactorily in service with no major problems, or any condition requiring corrective action. The only defects noted were minor impact damage, a few minor disbonds and a minor degree of fastener hole fraying and elongation. These are for the most part comparable to damage noted on fiberglass fairings. The service history obtained in this program indicates that Kevlar-49 epoxy composite materials have satisfactory service characteristics for use in aircraft secondary structure.

Stone, R. H.↗

Investigation of Structural Properties of Carbon-Epoxy Composites Using Embedded Fiber-Optic Bragg Gratings

Real time monitoring of the mechanical integrity and stresses on key aerospace composite structures like aircraft wings, walls of pressure vessels and fuel tanks or any other structurally extended components and panels as in space telescopes is very important to NASA. Future military and commercial aircraft as well as NASA space systems such as Space Based Radar and International Space Station will incorporate a monitoring system to sense any degradation to the structure. In the extreme flight conditions of an aerospace vehicle it might be desirable to measure the strain every ten centimeters and thus fully map out the strain field of a composite component. A series of missions and vehicle health management requirements call for these measurements. At the moment thousands of people support a few vehicle launches per year. This number can be significantly reduced by implementing intelligent vehicles with integral nervous systems (smart structures). This would require maintenance to be performed only as needed. Military and commercial aircrafts have an equally compelling case. Annual maintenance costs are currently reaching astronomical heights. Monitoring techniques are therefore required that allow for maintenance to be performed only when needed. This would allow improved safety by insuring that necessary tasks are performed while reducing costs by eliminating procedures that are costly and not needed. The advantages fiber optical sensors have over conventional electro-mechanical systems like strain gauges have been widely extolled in the research literature. These advantages include their small size, low weight, immunity to electrical resistance, corrosion resistance, compatibility with composite materials and process conditions, and multiplexing capabilities. One fiber optic device which is suitable for distributed sensing is the fiber Bragg grating (FBG). This is a periodic perturbation in the refractive index of the fiber core. When a broadband light is coupled into the optical fiber sensor, a reflection peak will be obtained centered around a wavelength called Bragg-wavelength. The Bragg-wavelength depends on the refractive index and the period of the grating, which both change due to mechanical and thermal strain applied to the sensor. The shift in the Bragg-wavelength is directly proportional to the strain. Researchers at NASA MSFC are currently developing techniques for using FBGs for monitoring the integrity of advanced structural materials expected to become the mainstay of the current and future generation space structures. Since carbon-epoxy composites are the materials of choice for the current space structures, the initial study is concentrated on this type of composite. The goals of this activity are to use embedded FBG sensors for measuring strain and temperature of composite structures, and to investigate the effects of various parameters such as composite fiber orientation with respect to the optical sensor, unidirectional fiber composite, fabrication process etc., on the optical performance of the sensor. This paper describes an experiment to demonstrate the use of an embedded FBG for measuring strain in a composite material. The performance of the fiber optic sensor is determined by direct comparison with results from more conventional instrumentation.

Osei, Albert J.↗

Advanced resin systems for graphite epoxy composites

The value of resin/carbon fiber composites as lightweight structures for aircraft and other vehicle applications is dependent on many properties: environmental stability, strength, toughness, resistance to burning, smoke produced when burning, raw material costs, and complexity of processing. A number of woven carbon fiber and epoxy resin composites were made. The epoxy resin was commercially available tetraglycidylmethylene dianiline. In addition, composites were made using epoxy resin modified with amine and carboxyl terminated butadiene acrylonitrile copolymer. Strength and toughness in flexure as well as oxygen index flammability and NBS smoke chamber tests of the composites are reported.

Gilwee, W. J.↗

Influence of Fiber Volume and Alignment on Impact Resistance of Braided Carbon Fiber Epoxy Composites

The effect of axial tow alignment within a laminate ply stack on the impact penetration threshold for a series of composite panels was evaluated; specifically, the effect of a lateral shift in alignment to induce fiber nesting. Panels were fabricated from braided T700S carbon fiber and TenCate Advanced Composites's TC275-1 epoxy resin prepreg. Axial tows in each ply were aligned, offset, or rotated to evaluate the influence of such parameters on impact penetration resistance. Panel-to-panel variation in thickness, resin content, and fiber volume ratio were measured. Ultimately, process-related deviations drove penetration limits on impact. Influence of axial tow alignment was difficult to discern outside of the processing-induced variations between panels.

process variation↗

Investigation of Structural Properties of Carbon-Epoxy Composites Using Fiber-Bragg Gratings

Fiber Bragg-gratings are embedded in carbon-epoxy laminates as well as bonded on the surface of cylindrical structures fabricated out of such composites. Structural properties of such composites is investigated. The measurements include stress-strain relation in laminates and Poisson's ratio in several specimens with varying orientation of the optical fiber Bragg-sensor with respect to the carbon fiber in an epoxy matrix. Additionally, Bragg gratings are bonded on the surface of cylinders fabricated out of carbon-epoxy composites and longitudinal and hoop strain on the surface is measured.

Grant, J.↗

Distributed Sensing of Carbon-Epoxy Composites and Filament Wound Pressure Vessels Using Fiber-Bragg Gratings

Multiple Fiber Bragg-gratings are embedded in carbon-epoxy laminates as well as in composite wound pressure vessel. Structural properties of such composites are investigated. The measurements include stress-strain relation in laminates and Poisson's ratio in several specimens with varying orientation of the optical fiber Bragg-sensor with respect to the carbon fiber in an epoxy matrix. Additionally, fiber Bragg gratings are bonded on the surface of these laminates and cylinders fabricated out of carbon-epoxy composites and multiple points are monitored and compared for strain measurements at several locations.

Grant, J.↗

Effects of postcuring on mechanical properties of pultruded fiber-reinforced epoxy composites and the neat resin

The effects of postcuring on mechanical properties of pultruded fiber-reinforced epoxy-resin composites have been investigated. Composites with carbon, glass, and aramid reinforcement fibers were individually studied. The epoxy was a commercially-available resin that was especially developed for pultrusion fabrication. The pultrusions were conducted at 400 F with postcures at 400, 450, 500, and 550 F. Measurements of the flexural, shear, and interlaminar fracture-toughness properties showed that significant postcuring can occur during the pultrusion process. All three mechanical properties were degraded by the higher (500 and 550 F) temperatures; photomicrographs suggest that the degradation was caused at the fiber-resin interface for all three fiber types.

Long, Edward R., Jr.↗

Toughening reinforced epoxy composites with brominated polymeric additives

Cured polyfunctional epoxy resins including tris (hydroxyphenyl) methane triglycidyl ether are toughened by addition of polybrominated polymeric additives having an EE below 1500 to the pre-cure composition. Carboxy terminated butadiene acrylonitrile rubber is optionally present in the precure mixture as such or as a pre-formed copolymer with other reactants. Reinforced composites, particularly carbon reinforced composites, of these resins are disclosed and shown to have improved toughness.

Nir, Z.↗

Toughening reinforced epoxy composites with brominated polymeric additives

Cured polyfunctional epoxy resins including tris(hydroxyphenyl)methane triglycidyl ether are toughened by addition of polybrominated polymeric additives having an EE below 1500 to the pre-cure composition. Carboxy-terminated butadiene-acrylonitrile rubber is optionally present in the pre-cure mixture as such or as a pre-formed copolymer with other reactants. Reinforced composites, particularly carbon-reinforced composites, of these resins are disclosed and shown to have improved toughness.

Nir, Z.↗