Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Synthetic residential load models for smart city energy management simulations

The ability to control tens of thousands of residential electricity customers in a coordinated manner has the potential to enact system-wide electric load changes, such as reduce congestion and peak demand, among other benefits. To quantify the potential benefits of demand-side management and other power system simulation studies (e.g. home energy management, large-scale residential demand response), synthetic load datasets that accurately characterize the system load are required. This study designs a combined top-down and bottom-up approach for modelling individual residential customers and their individual electric assets, each possessing their own characteristics, using time-varying queueing models. The aggregation of all customer loads created by the queueing models represents a known city-sized load curve to be used in simulation studies. The three presented residential queueing load models use only publicly available data. An open-source Python tool to allow researchers to generate residential load data for their studies is also provided. The simulation results presented consider the ComEd region (utility company from Chicago, IL) and demonstrate the characteristics of the three proposed residential queueing load models, the impact of the choice of model parameters, and scalability performance of the Python tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Interior Cellular Shades in a Residential Building

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope and sometimes from unwanted solar heat gain. Window attachments can help to mitigate this demand by controlling the solar heat gains and enhancing the thermal resistance of the windows. In this study, the energy savings potential of cellular shades in residential homes is studied using experimental testing and energy simulations. The energy performance of the shading devices was experimentally tested during the heating season from December 2019 to May 2020 with a focus on cellular shades. Five shading devices—three single and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal (venetian) blinds using two nearly identical sideby-side rooms in a residential building with their exterior window facing east. Another objective of the experimental testing was to evaluate any impact of the side-channel of the shading device on energy savings. To observe the impact of the side-channels on energy savings, from shades in two of the test cases, cellular shades with side-channels were used. From the experimental testing, daily energy savings in the range of 9% to 23% were observed by considering data from 6 p.m. until 6 a.m. of the next day.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling subsurface and above-surface models for optimizing the design of borefields and district heating and cooling systems in the presence of varying water-table depth. In: Proceedings, 46th Workshop on Geothermal Reservoir Engineering

Dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes, without flow of groundwater. On the other hand, detailed simulation tools for subsurface heat and mass transfer exist, but these fall short in simulating above-surface energy systems. To support the design and operation of such systems, we have developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the ground. For the first, we use the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, we use the TOUGH simulator. TOUGH can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. In previous work, we described the coupling of these software packages, including how time-dependent boundary conditions for the borehole walls are synchronized for use in Modelica and TOUGH. We verified that the coupled Modelica/TOUGH code produced consistent results with the original Modelica code for an idealized problem in which heat transfer was purely by conduction in a uniform geologic medium. Here, we examine less idealized problems for which TOUGH’s advanced capabilities for modeling fluid flow are required. The first problem has a shallow vadose zone, and the second problem has a thicker vadose zone with a water-table depth that varies in time, which requires a fine vertical grid discretization for the TOUGH model.

Doughtry, Christine↗

Flexible Integration of Diverse HVAC Technologies in EnergyPlus via Python-Enabled Workflows

Analysis of advanced controls and novel system types is often not directly feasible in building energy simulation tools. Various techniques extend building energy simulation tool capabilities to allow the use of user-defined scripts and programs, but these approaches have limitations. The EnergyPlus Python plugin offers users new flexibility to use EnergyPlus to call an external Python module at specific points in the simulation, as well as to use Python to call EnergyPlus functionality through an application programming interface (API). This paper presents four case studies leveraging the EnergyPlus Python plugin to facilitate analysis of advanced controls and system types. The use of the Python plugin offers greater modularity and flexibility relative to previous approaches, is less error prone, and is simpler for users to adopt. The Python plugin allows EnergyPlus to be used in a more flexible manner and to accommodate the expanding realm of energy modeling applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of wind resource and energy production simulations for small wind turbines in the United States

Abstract. Due to financial and temporal limitations, the small wind community relies upon simplified wind speed models and energy production simulation tools to assess site suitability and produce energy generation expectations. While efficient and user-friendly, these models and tools are subject to errors that have been insufficiently quantified at small wind turbine heights. This study leverages observations from meteorological towers and sodars across the United States to validate wind speed estimates from the Wind Integration National Dataset (WIND) Toolkit, the European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis v5 (ERA5), and the Modern-Era Retrospective Analysis for Research and Applications, version 2 (MERRA-2), revealing average biases within ±0.5 m s−1 at small wind hub heights. Observations from small wind turbines across the United States provide references for validating energy production estimates from the System Advisor Model (SAM), Wind Report, MyWindTurbine.com, and Global Wind Atlas 3 (GWA3), which are seen to overestimate actual annual capacity factors by 2.5, 4.2, 11.5, and 7.3 percentage points, respectively. In addition to quantifying the error metrics, this paper identifies sources of model and tool discrepancies, noting that interannual fluctuation in the wind resource, wind speed class, and loss assumptions produces more variability in estimates than different horizontal and vertical interpolation techniques. The results of this study provide small wind installers and owners with information about these challenges to consider when making performance estimates and thus possible adjustments accordingly. Looking to the future, recognizing these error metrics and sources of discrepancies provides model and tool researchers and developers with opportunities for product improvement that could positively impact small wind customer confidence and the ability to finance small wind projects.

17 WIND ENERGY↗

The relative importance of building design parameters in reducing energy use and sensible heat release from buildings in light of forecasted future weather data and building coverage ratio

Buildings typically have a 60-to-75-year lifespan before they require significant maintenance or modifications. However, most builders evaluate the performance of their new buildings using whole-building energy simulation tools based on the current typical meteorological year (TMY) file or actual meteorological year. The energy use consumption and sensible heat release pattern observed from buildings could potentially change based on shifting global climates. Therefore, the recommended energy-efficiency design parameters might also change during these periods. In this study, we evaluate the role of different building design parameters, such as material reflectivity, HVAC COP, and insulation values, on building energy usage and sensible heat release from buildings with different building coverage ratios (BCR), based on the current and future weather file TMY (fTMY) for the middle of the century (2040–2060). The role of sensible heat release from buildings is not accounted for accurately while estimating building energy usage in most whole-building energy simulations. The study conducts a series of whole-building energy simulation analyses using EnergyPlus to evaluate the role of different design parameters based on TMY and fTMY weather conditions. The analysis is conducted for two hot desert climatic cities: Phoenix (USA) and Abu Dhabi (UAE). The results show that, for the base case in a future climate, the sensible heat release is reduced by an average of 30% due to the reduced delta T between the surface and ambient air. Further, the results show an increase in total energy consumption by 5% annually. The results also show that, for buildings with traditional coatings, shorter buildings release more heat than taller buildings. On the other hand, for buildings with reflective paints, shorter buildings release less heat than taller buildings. The findings from this study can be used by policymakers, utility companies, and builders to better understand the relative role of different building design parameters while constructing new and retrofitting existing buildings.

Alhazmi, Mansour [King Fahd University of Petroleu↗

Integration of Thermoelectric Modules to Vapor Compression Systems

This paper describes the technology of a thermoelectric (TE) integrated heat pump. It uses a TE heat pump to subcool the refrigerant liquid before entering the evaporator to enlarge the evaporating capacity; and elevate the heat in the refrigerant flow to a supplemental heating coil and discharge the capacity to the indoor air flow. Using the DOE/ORNL Heat Pump Design Model, four system configurations were modelled on a baseline two-speed heat pump, the baseline heat pump with adding a supplemental coil, the TE integrated heat pump having one stage TE heating to control a 20R liquid refrigerant temperature drop; and having two stages TE heating to control up to 40R temperature drop. The system models were used to produce performance curves for EnergyPlus building energy simulations. We selected template residential buildings, poorly insulated: pre-1990 buildings, and well-insulated: IECC2021 buildings; in five cold climate zones: 5A, 5B, 6A, 6B, 7. The building energy simulations demonstrated energy saving potentials, utility cost reductions and estimated payback periods.

Shen, Bo↗

Global energy balance simulations of shattered pellet injection

The dynamics of shattered pellet injection (SPI) shutdowns are simulated using a time-dependent global energy balance model, based on a modification of the KPRAD framework. The new SPI particle source in the model calculates the ablation of individual pellet fragments that enter the plasma as a temporally resolved plume, thus capturing the effects of earlier fragments on the ablation of those that follow, which has a significant impact on the overall assimilation. Despite the reduced physics and the global averaging of all quantities, results from a large number of DIII-D, KSTAR, and JET experiments are well reproduced, including the plasma cooling timescales, particle assimilation, and current quench (CQ) rates. Cooling timescales and CQ rates are in good agreement for pellets containing as little as ∼1% neon, while particle assimilations are most accurate for neon fractions above ∼15% by number of atoms. Below this, the assimilation tends to be overestimated due to the lack of radial transport in the particle balance, which becomes important in the low-Z limit. Predictive simulations of mixed-composition dual-SPI shutdowns in ITER are compared against those with the 3D non-linear magnetohydrodynamic code JOREK and are found to reproduce overall trends observed in the higher-fidelity modeling across a range of injection scenarios. The general success of the model points to the critical role of energy balance in determining SPI particle assimilation and the subsequent disruption dynamics and highlights the value of these simulations for experimental interpretation and for optimizing the deployment of computationally expensive, higher-fidelity models.

energy balance model↗

Update of ASHRAE Standard 140 Section 5.2 and Related Sections (BESTEST Building Thermal Fabric Test Cases)

This report documents new work intended to update the current building thermal fabric software-to-software comparative test specifications and example results of ANSI/ASHRAE Standard 140-2017, Sections 5.2.1, 5.2.2, 5.2.3, and related supporting sections. The Building Energy Simulation Test and Diagnostic Method (BESTEST) test specification and example results that provide the basis for these Standard 140 sections were originally published in 1995. The state of the art in building energy simulation modeling has advanced since then. Additionally, comments on the test specification over the years highlighted ambiguities, further necessitating the update to the original work. This new work was conducted for the U.S. Department of Energy (DOE) by Argonne National Laboratory (Argonne) and National Renewable Energy Laboratory (NREL), in collaboration with a working group of international experts associated with the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standing Standard Project Committee (SSPC) 140. SSPC 140 is responsible for ANSI/ASHRAE Standard 140. The new work, presented in this report, defined the test cases and specifications such that building energy simulation programs with time steps of one hour or less can perform the tests. Revisions to the test specification and update of example results follow the vetting process of iterative field trials established for previous BESTEST work that has been adapted for ASHRAE Standard 140.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Engagement: Hyperparameter Optimization of Generative Adversarial Network Models for High-Energy Physics Simulations

We present our SciDAC FASTMath-HEP partnership results for tuning generative adversarial models (GANs) for high energy physics applications. The GANs are used in hybrid simulations to accelerate otherwise time-consuming computations. We optimize for both, prediction accuracy and variability with the goal to find GAN architectures that are reliable and robust.

high energy physics↗

Establishing capabilities for quantum computing and simulations for energy applications

Quantum information science (QIS) is creating potential transformative opportunities to exploit intricate quantum mechanical phenomena in new ways for obtaining and processing information to advance many areas of science and engineering. Since the National Quantum Initiative Act was signed into law in 2018, developing QIS capability and competency is one of the most urgent tasks of DOE to make sure the US win the quantum race. The QIS contains four pillars: quantum computing, quantum simulations, quantum sensing, and quantum networking. To apply QIS in energy related applications, the key is to develop the capability of quantum computing & simulation tools. In this project, we propose to develop the capability of quantum computing and simulations at NETL to target fossil energy related problems. We will install a simulator (e. g. IBM qiskit) on the NETL supercomputer to simulate the environments of quantum computer. Based on the current available quantum algorithms for quantum chemistry, we will develop quantum computing codes to perform simulation which will focus on fossil energy sector challenges, including CO2 capture & conversion, sensing, and fuel conversion. We then will seek opportunities to run our codes on real quantum computers (such as IBM-Q, google Sycamore, etc.). Through this project, the new capability of quantum computing and simulations will be established at NETL. In addition, the NETL workforce in this area will be trained ready to conduct more complicated tasks in line with NETL missions to enhance the nation’s energy foundation.

97 MATHEMATICS AND COMPUTING↗

Quantifying the time‐specific kinetic energy of simulated rainfall using a dynamic rain gauge system

Abstract Raindrop impact derives from the kinetic energy of falling raindrops. Determining the kinetic energy of rainfall requires the size distribution and terminal velocity of raindrops, which necessitates complex instrumentation. To avoid this, empirical relations have been developed that relate rainfall intensity and the rate of kinetic energy, i.e., time‐specific kinetic energy (KE time ). In this study, a dynamic rain gauge system (DRGS) was used to quantify the KE time generated by a rainfall simulator without need of measuring raindrop size distributions or impact velocities. In a series of 10 rainfall tests, the KE time and rainfall intensity were 860.9 (±88.6) J m 2 h −1 and 72.1 (±1.9) mm h −1 , respectively. Estimated KE time was found to agree well with the power‐law relation presented by Petrů and Kalibová for high‐intensity simulated rainfall, which are the conditions when higher deviations occur. The DRGS may be a useful tool in quantifying the KE time of rainfall simulators in hopes to better understand raindrop impact mechanisms.

Wacha, Kenneth M.↗

Quantum Computing and Simulations for Energy Applications

While quantum computing (QC) is considered as a paradigm shift in our basic understanding of physical computation, effective implementation of QC in energy applications also depends on progress and development in the dimensions of both QC hardware and algorithms. To fully address the status and future challenges of QC applied within the energy sector, in this presentation, we firstly summarize recent advancements on the applications of QC to energy infrastructure and materials, complex energy system processes, advanced manufacturing, and energy system security. Then, we will demonstrate the results of QC performed both on a simulator and a quantum device targeting on energy-related applications.

Paudel, Hari P.↗

Simulation of energy loss of fractionally charged particles using Geant4

Over the years several rare-event search experiments have shown increasing interest to search for Fractionally Charged Particles (FCPs) within the data acquired in those experiments. This, in turn, has required the need for a framework to calculate accurately the energy loss expected from FCPs as they pass through the detector material. We have developed Monte Carlo methods within Geant4 to simulate for the first time energy loss of FCPs through different physics processes. The program can be used to calculate energy deposition distributions, a major component of any FCP search analysis, as they interact with detector material. We discuss the implementation and validation of the energy loss of FCPs using a typical detector material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of simulated wave energy converter responses to focused waves

Focused waves are increasingly used as a design method to predict extreme loads for offshore structures, such as wave energy converters (WECs). However, the ability of computational methods to accurately simulate the prescribed focused waves and resulting wave structure interactions is not well validated. This study uses two computational fluid dynamic methods, WEC-Sim and STAR-CCM+, to evaluate the responses of two taut-moored WEC-like buoys to three different focused waves. WEC-Sim is a computationally efficient, mid-fidelity model, based on linearised potential flow theory. In contrast, STAR-CCM+ is a high-fidelity, three-dimensional, unsteady, Reynolds-averaged Navier–Stokes-based model. The two buoy geometries considered are a hemispherical-bottom cylinder and a truncated cylinder with a cylindrical moon pool. Three prescribed focused waves are generated in both codes, and the simulated displacements and mooring loads are obtained for each of the hydrodynamic bodies. The resulting STAR-CCM+ generated focused waves have approximately the same accuracy, in comparison with the analytic solution, as experimentally generated focused waves. The WEC-Sim simulated responses, when using viscous coefficients tuned to the measured displacements, are, on average, within 11.5% of experimentally measured values, whereas the STAR-CCM+ simulated responses are, on average, within 14.2% of the experimental values.

16 TIDAL AND WAVE POWER↗

Learning to simulate high energy particle collisions from unlabeled data

In many scientific fields which rely on statistical inference, simulations are often used to map from theoretical models to experimental data, allowing scientists to test model predictions against experimental results. Experimental data is often reconstructed from indirect measurements causing the aggregate transformation from theoretical models to experimental data to be poorly-described analytically. Instead, numerical simulations are used at great computational cost. We introduce Optimal-Transport-based Unfolding and Simulation (OTUS), a fast simulator based on unsupervised machine-learning that is capable of predicting experimental data from theoretical models. Without the aid of current simulation information, OTUS trains a probabilistic autoencoder to transform directly between theoretical models and experimental data. Identifying the probabilistic autoencoder’s latent space with the space of theoretical models causes the decoder network to become a fast, predictive simulator with the potential to replace current, computationally-costly simulators. Here, we provide proof-of-principle results on two particle physics examples, Z-boson and top-quark decays, but stress that OTUS can be widely applied to other fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗