Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

A CHIL Validation of Machine Learning-Assisted Methods for Real-Time Controls of Solar PV for Grid Services

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been proposed; however, these technologies lack comprehensive validation under real-world application scenarios. This paper addresses this gap by designing and developing a controller-hardware-in-the-loop framework to evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. Simulation results indicate the superior performance of an ML-based approach compared to the conventional reference-control grouping-based approach, showcasing its potential to support grid stability and operational efficiency.

14 SOLAR ENERGY↗

A CHIL Validation of Machine Learning-Assisted Methods for Real-Time Controls of Solar PV for Grid Services: Preprint

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been proposed; however, these technologies lack comprehensive validation under real-world application scenarios. This paper addresses this gap by designing and developing a controller-hardware-in-the-loop framework to evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. Simulation results indicate the superior performance of an ML-based approach compared to the conventional reference-control grouping-based approach, showcasing its potential to support grid stability and operational efficiency.

closed-loop validation↗

Enabling Technology for Energy Sustainability: Power Electronic Converter Control for Renewables

To ensure high penetration of renewable energy sources into power grids, their interfacing inverters need to be designed to provide grid support functions. Important grid support functions include frequency and voltage support. To this end, the research community has recently invested heavily on grid-forming control pilot projects. Grid forming control aims to replace traditional grid following control, which is based on phase-locked loop and can achieve decoupled real and reactive power control. Here, in this article, we review the state-of-the-art grid following and forming technology and point out some deficiencies in dynamic performance in the widely adopted grid-forming control design. We also examine how to ensure that the vector control capable of decoupled real and reactive power regulation can also be achieved in the grid forming design. This type of design has been prototyped and shown great potential to enable retrofitting of large amounts of grid-following controllers through purely software algorithm update. The technology ensures reliable operation of power grids with high penetration of IBRs, thereby further reducing fossil fueled energy sources and cut down carbon emission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Practical low-temperature gasoline combustion for very high efficiency off-road, medium- and heavy-duty engines

Low-temperature gasoline combustion (LTGC) with additive-mixing fuel injection (AMFI) is a new combustion strategy that has been demonstrated to deliver 9%–25% better brake thermal efficiency than similar-sized market-leading diesel engines over the operating map. Moreover, the LTGC-AMFI engine shows near-zero smoke, and NOx emissions are 4–100 times lower than those of a diesel, sufficiently low that no aftertreatment, or only passive NOx aftertreatment, would be sufficient (diesel exhaust fluid is not required). LTGC-AMFI combustion is based on kinetically controlled compression ignition of a dilute charge with a variable amount of low-to-moderate fuel stratification. Fast combustion control is provided by adding minute amounts of an ignition-enhancing additive into the fuel each engine cycle to control its reactivity. This strategy was used to operate a medium-duty (MD) LTGC-AMFI engine at loads from idle to 16.3 bar BMEP and speeds from 600 to 2400 rpm with regular E10 gasoline, which covers nearly the entire operating map of a typical MD engine. Turbine-out temperatures were sufficient for an oxidation catalyst to control hydrocarbon and CO emissions. Autonomie simulations over the GEM ARB Transient and the GEM 55 mph Cruise driving cycles for class-6 trucks using this technology showed fuel economies of 8.1 and 11.4 mpg-gasoline-equivalent, respectively, corresponding to 18.6% and 13.4% improvements over a similar-size diesel engine. Engine-out NOx emissions were 0.024 and 0.01 g/bhp-h, respectively, well below current U.S. emission standards. These results show that switching from diesel to LTGC-AMFI engines would greatly reduce greenhouse gas (GHG) emissions for off-road, MD and HD applications, which will continue to rely on combustion engines because electrification is not practical in the foreseeable future. Finally, with their reduced fuel consumption, the lower cost of gasoline compared to diesel fuel, and much lower aftertreatment costs, LTGC-AMFI engines also offer a significantly lower total cost of ownership.

33 ADVANCED PROPULSION SYSTEMS↗

Update on Mitigation of Aerosol Impacts on Ash Deposition and Emission from Coal Combustion

Barr, in partnership with the University of North Dakota, Microbeam Technologies Inc., Envergex LLC, and MLJ Consulting, worked to develop a transformational technology that controls the formation of alkali aerosols found in coal ash. This technology mitigates ash deposition by injecting sorbents into the boiler and capturing volatile species responsible for boiler fouling, the primary cause for boiler outages. In this session, we’ll explore the science behind this technology and see some real-world results of its implementation.

01 COAL, LIGNITE, AND PEAT↗

Spin-Controllable Dynamics in Defect-Engineered Carbon Nanotubes as Single Photon Emitters: Data-Driven Modeling and Computations

Quantum technologies, such as quantum computing and sensing, require efficient single-photon emission (SPE) sources that operate at room temperature in telecom wavelengths. While several materials can serve as SPE sources, no single platform meets all the criteria for efficiency, ambient operation, and scalability. Single-walled carbon nanotubes (SWCNTs) with covalently attached molecules offer a promising solution. Their SPE can be easily tuned via modifications of the SWCNT's diameter, chirality, and bonded molecules, enabling emission across near-IR to telecom wavelengths at ambient conditions. However, to fully realize the potential of SWCNTs and unlock their quantum capabilities, a deeper understanding of how structural defects from molecular adducts affect their emission and competing photoexcited processes is essential. To address this gap in our knowledge, this project combined quantum chemistry calculations with data-driven methods of cheminformatics (QSAR) and machine learning (ML). The developed computational approaches have provided several design strategies for covalent functionalization of SWCNTs to improve their optical response. The collaboration with Los Alamos National Lab (LANL) enabled direct comparison of computational and experimental data, facilitating method validation. This partnership was enhanced through access to LANL's Center for Integrated Nanotechnologies (CINT) utilizing User Facility Program and summer internships, which provided three NDSU graduate students with hands-on experience at LANL. The outcomes of this project included (1) Advancing the current stage of computational methods in accurate modeling of non-adiabatic spin-dependent photoexcited dynamics and its applicability to nanosystems consisting of thousands of atoms, realized as open-access codes linked to existing DFT-based software; (2) Establishing the relationship between the structure of adducts and SWCNTs and intrinsic excitonic and spin properties of defect states for guiding novel synthetic strategies and experimental probes of chemically functionalized SWCNTs as near-IR emitting materials; (3) Generating virtual libraries of hypothetical functionalized SWCNTs for virtual screening of their chemical structures and optical properties, leveraging new functionalities of SWCNTs; (4) Offering a unique experience for NDSU graduate students that prepared them for future scientific careers related to materials modeling and big data processing. These results were summarized in 12 published journal papers and 3 recently submitted papers. One of a key finding is that the position of defect sites on the SWCNT surface primarily drives the emission redshift (up to 100 meV), while the polarity of the defect-inducing molecules has a much smaller effect (~10 meV). However, the electron-donating or withdrawing properties of a molecule influence selecting reactivity of defect sites. These insights important for optimizing synthetic protocols for desired emissions in SWCNTs. We also revealed that the interaction between two defects at various positions on the SWCNT enhances the redshift and optical activity of states, favoring strong near-IR emission. This suggests that manipulations in defect concentrations is a promising strategy for controlling efficient emission. Mostly important, the defect position was found controllable by the spin states of photoexcited intermediates: Excited aromatic molecules form ortho defects with SWCNTs at their singlet states in the presence of oxygen, while oxygen-free conditions favor para defects via the triplet-state mechanism. Additionally, a heat-activated [2+2] cycloaddition reaction facilitates divalent defect formation with fewer bonding positions that narrows emission bands. These groundbreaking findings have been experimentally validated and significantly advance our understanding of defect chemistry in SWCNTs. Using a novel encoding technique and 3D-MoRSE descriptors, we developed highly accurate ML/QSAR models to predict both the 3D structure and optical properties of SWCNTs with chemical defects. This model enabled the creation of a virtual library of 125,556 structures, providing new insights into the relationship between SWCNT-defect structure and emission.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Epitaxial strain tuning of Er 3+ in ferroelectric thin films

Er 3+ color centers are promising candidates for quantum science and technology due to their long electron and nuclear spin coherence times, as well as their desirable emission wavelength. By selecting host materials with suitable, controllable properties, we introduce new parameters that can be used to tailor the Er 3+ emission spectrum. PbTiO 3 is a well-studied ferroelectric material with known methods of engineering different domain configurations through epitaxial strain. By distorting the structure of Er 3+ -doped PbTiO 3 thin films, we can manipulate the crystal fields around the Er 3+ dopant. This is resolved through changes in the Er 3+ resonant fluorescence spectra, tying the optical properties of the defect directly to the domain configurations of the ferroelectic matrix. Additionally, we are able to resolve a second set of peaks for films with in-plane ferroelectric polarization. We hypothesize these results to be due to either the Er 3+ substituting different sites of the PbTiO 3 crystal, differences in charges between the Er 3+ dopant and the original substituent ion, or selection rules. Systematically studying the relationship between the Er 3+ emission and the epitaxial strain of the ferroelectric matrix lays the pathway for future optical studies of spin manipulation by altering ferroelectric order parameters.

36 MATERIALS SCIENCE↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

Control of Nonlinear Compton Scattering in a Squeezed Vacuum

Electromagnetic radiation by accelerated charges is a fundamental process in physics. Here, we introduce a quantum-optical framework for controlling the emission of radiation of an electron in an intense laser field via squeezed vacuum states. By engineering the quantum fluctuations of the emission modes, we demonstrate that the probability of nonlinear Compton scattering can be significantly enhanced or suppressed through tunable squeezing amplitude and angle. We show numerically that our predictions are experimentally accessible with current squeezing technologies, establishing a new paradigm for quantum control in high-intensity light-matter interactions.

Light-matter interaction↗

Evaluating Class 6 Delivery Truck Fuel Economy and Emissions Using Vehicle System Simulations for Conventional and Hybrid Powertrains and Co-Optima Fuel Blends

The US Department of Energy’s Co-Optimization of Engine and Fuels Initiative (Co-Optima) investigated how unique properties of bio-blendstocks considered within Co-Optima help address emissions challenges with mixing controlled compression ignition (i.e., conventional diesel combustion) and enable advanced compression ignition modes suitable for implementation in a diesel engine. Additionally, the potential synergies of these Co-Optima technologies in hybrid vehicle applications in the medium- and heavy-duty sector was also investigated. In this work, vehicles system were simulated using the Autonomie software tool for quantifying the benefits of Co-Optima engine technologies for medium-duty trucks. A Class 6 delivery truck with a 6.7 L diesel engine was used for simulations over representative real-world and certification drive cycles with four different powertrains to investigate fuel economy, criteria emissions, and performance. Comparisons were made between ultralow-sulfur diesel and a blend of 25% hexyl hexanoate with diesel. Model validation data were informed by 2019 model year Cummins ISB 6.7 L diesel engine maps and transient validation data in a pre-production hybrid configuration and a direct dyno coupled configuration with diesel fuel and a blend of 25% hexyl hexanoate with diesel.

33 ADVANCED PROPULSION SYSTEMS↗

Design and Optimization of Structured Multi-Functional Trapping Catalysts for Conversion of Hydrocarbons and NOx from Diesel and Advanced Combustion Engines

Oxides of nitrogen in the form of nitric oxide (NO) and nitrogen dioxide (NO 2 ) commonly referred to as NOx, is one of the two chemical precursors that lead to ground-level ozone, a ubiquitous air pollutant in urban areas. A major source of NOx is generated by equipment and vehicles powered by diesel engines, which have a combustion exhaust that contains NOx in the presence of excess O 2 . Vehicular emission control catalysts are ineffective in eliminating CO, hydrocarbons, and NO x during engine cold-start when exhaust temperatures are below 200°C. The objective of the project was to develop and demonstrate a multi-functional, catalyzed trap that enables vehicles with advanced combustion strategies to meet Tier 3 emissions standards while achieving the 150 °C challenge for sustained co-oxidation of HCs and CO and ≥90% NO trapping and release during warmup. Specifically, the multi-functional Lean HC+NOx (LHCNT) was developed for application in the exhaust aftertreatment of conventional diesel engines and engines having low temperature combustion (LTC) regimes. Activities included the design and synthesis of adsorbents and catalysts, screening and evaluation. Passive NOx absorbers (PNA), hydrocarbon (HC) traps, and oxidation catalysts (OC) were evaluated for use in series or as integrated devices. Predictive tools were developed utilizing the characterization and analysis of these materials, and an emission system was designed and optimized utilizing the catalyst systems. Microkinetic models were developed for the PNA for the simple NO-only feed and complex feed containing CO, H 2 , and model hydrocarbons (ethylene and dodecane). A first-principles, mechanistic-based model of the PNA was developed which utilized molecular-scale estimates (density functional theory) of energy barriers, mechanistic-based kinetics and realistic treatments of the flow and transport processes. Two new oxidation catalysts were developed (PdCu alloy, mixed copper-ceria-cobalt oxide), both of which significantly lessened the detrimental inhibition by CO on hydrocarbon and NO oxidation. A method for lessening the detrimental impact of CO on PNA activity was developed that involves use of an oxidation catalyst upstream of the PNA. The SwRI Ectolab TM burner system was applied to evaluate the baseline PNA material and confirmed performance comparable to the benchflow PNA studies using simulated exhaust. Spatially-resolved mass spectrometry (SpaciMS) was used to measure the transient spatial profiles of reacting species spanning the length of a three-function LHCNT containing PNA, HCT, and OC. The findings from this study provide diesel vehicle and catalyst companies valuable information to develop more cost effective emission control catalysts which helps to expand the use of more fuel efficient diesel power. The fundamental modeling and experimental tools and findings from this project can be applied to catalyst technologies used in the energy and chemical industries. The project led to 14 publications in the peer-reviewed literature with 2 additional currently under review. Finally, the project also led to training of several doctoral students who were placed in research jobs in industry and academia. Specifically, Mugdha Ambast (UH) has joined Cummins, Kevin Gu (UVa) has joined GM, and Abhay Gupta (UH) is to join Caterpillar.

42 ENGINEERING↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Ducted Fuel Injection And Cooled Spray Technologies For Particulate Control In Heavy-duty Diesel Engines (Final Report)

Cooled Spray (CS) and Ducted Fuel Injection (DFI) are in-cylinder technologies for diesel engines that can reduce particulate matter and soot emissions and data has been published showing that these technologies can reduce soot emissions by 75-100% for some engines at some operating conditions. However, little is known about scaling the devices for engine size. Additionally, the performance of either technology over the engine duty cycle has not been explored. This project addresses both of these points through single-cylinder engine investigations. The objectives of this project are to provide details about dimensional scaling of these devices and to demonstrate 75% PM reduction over a range of operating conditions on a single-cylinder engine. Two engines were used for this project: a 125mm bore optically accessible engine at Sandia National Laboratories and a 168mm bore metal engine at Southwest Research Institute. The optical engine was used to study the performance of DFI and CS inserts for a large injector orifice diameter injector that is characteristic of a locomotive engine and to perform scaling studies for DFI. The metal engine was used to perform scaling and alignment studies for CS and to evaluate the technology for both EGR and non-EGR engines over the engine operating map. Modifications were required for both engines to accept the prototype inserts being tested. The optical engine required a new fuel injector, cylinder head and piston so that tests could be run at the pressures and engine speeds required. Additionally, a novel rotating stage was designed for the optical engine to simplify alignment of the modules. The metal engine required a modified cylinder head to accept CS inserts and a modified piston to provide additional space around the fuel injector for the CS inserts. Tests on the optical engine showed that DFI reduces PM emissions for both small injector orifices (0.170mm diameter) and large injector orifices (0.290mm). For high load testing, the DFI modules were not as effective as at low load testing, but it was acknowledged that minimal geometric optimization was performed and more improvements may be possible. Comparing DFI to CS and conventional diesel combustion (CDC), DFI performed better than CS or CDC. The CS geometries used in these studies may not be ideal for that engine and additional modifications likely would improve performance. Tests on the metal engine showed PM reductions as high has 80% at some operating conditions with duty-cycle PM reductions of ~50% for EGR and non-EGR configurations. The CS testing on the metal engine showed that chamfering of the fuel passage inlet either through hydro-erosion or mechanical grinding provided significant improvements in the PM reduction capabilities of the insert. Additionally, alignment sensitivities were explored and the data show that the tolerance to misalignment is approximately 0.05 to 0.1mm for the inserts that were studied here. Air-fuel ratio was shown to be important in the effectiveness of the CS inserts. In several tests, it was shown that the CS inserts are more effective at reducing the PM for high-AFR operating conditions compared to low AFR conditions. In summary, multiple designs were evaluated on both engines. It was found that for the conditions and configurations studied here, a fuel passage diameter of ~2.5mm performed best overall. Significant duty-cycle PM reductions are possible using these technologies and sensitivities to AFR, alignment fuel passage diameter and inlet fuel passage shaping were explored and are reported here. More PM reduction may be possible with improved geometric design and attention to alignment practices.

02 PETROLEUM↗

Modeled Retrofit Package Performance for Schools

This report details modeled energy performance and savings from retrofit packages in prototypical school buildings in climate zones throughout the U.S. The information herein serves as a reference for elementary and secondary schools interested in implementing retrofit packages in their facilities for energy savings as well as health and safety benefits. School models developed for simulating package performance differentiated between rural and urban environments. Simulations were run for 10 distinct climate zones covering a range of climate conditions throughout the U.S. Results include savings estimates for electricity, natural gas, CO 2 emissions, and annual utility costs for nine different retrofit packages that combine energy conservation measures, including HVAC controls and equipment upgrades, lighting efficiency upgrades, and electrification technologies such as heat pumps for space conditioning and domestic hot water. Nine additional retrofit packages were also developed for elementary schools and modeled in two climate zones. Appendix B describes the additional retrofit packages and presents savings estimates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct Air Capture and Utilization System (DACUS): FEED Study of CarbonCapture Inc. DAC and CarbonCure Utilization Technologies Using United States Steel’s Gary Works Plant Waste Heat

The effects of climate change are drastically perceived through the alarming rates of severe events such as flooding, hurricanes, wildfires, global temperature rise, sea-level rise, and ocean acidification etc., which has prompted the nations across the globe to control & reduce greenhouse gas (GHG) emissions, by massive adoption of electric vehicles, switching to renewal energy sources and promoting sustainable green products. However, recent climate studies have shown that such efforts will not be enough to keep the global temperature rising under 1.5° Celsius by the year 2050, which lead to the development of multiple Direct Air Capture (DAC) technologies. A DAC system extracts CO2 directly from the atmosphere, which is either stored underground for long term or utilized in other processes. The DACUS proposed at U.S. Steel Corporation’s Gary Works Plant in Gary, Indiana, will include an innovative DAC technology from CarbonCapture Inc. (CCI), which will be collocated and powered by waste heat from the steel plant to capture CO2 from ambient air, and CarbonCure CO2 utilization technology- which is a commercial technology that is already installed and in use by early adopters in more than 150 concrete mixing plants across North America and Asia. The University of Illinois at Urbana Champaign spearheaded this Front-End Engineering Design (FEED) study project, which was funded by US Department of Energy (DOE), aimed at designing a state-of-the art DACU system that can remove minimum of 5,000 tonne/year net CO2 from air (based on cradle-to-gate LCA) and converting the captured CO2 into low carbon intensity products. The off takers of the low Carbon product produced by the DACUS have also been identified near the steel plant in the Indiana, Illinois & Wisconsin Region. This creates a full CO2 value chain and provides a means to assess the impact of this holistic approach on job creation, regional economic impact, and environmental justice. DACUS is a promising new technology for reducing greenhouse gas in the atmosphere. Operation costs are minimized by locating CCI’s innovative DAC collector at United States Steel's Gary Works site where waste heat is utilized. Carbon emissions are minimized in CO2 transportation. The captured CO2 will be permanently sequestered in concrete used as construction material. This DOE funded FEED study demonstrates a full CO2 value chain for a DACU system, supported by an industrial facility. If this project were constructed, it would have a very positive and lasting impact on both the environment and the community.

42 ENGINEERING↗

Design and Optimization of Structured Multi-Functional Trapping Catalysts for Conversion of Hydrocarbons and NOx from Diesel and Advanced Combustion Engines

Oxides of nitrogen in the form of nitric oxide (NO) and nitrogen dioxide (NO 2 ) commonly referred to as NOx, is one of the two chemical precursors that lead to ground-level ozone, a ubiquitous air pollutant in urban areas. A major source of NOx is generated by equipment and vehicles powered by diesel engines, which have a combustion exhaust that contains NOx in the presence of excess O 2 . Vehicular emission control catalysts are ineffective in eliminating CO, hydrocarbons, and NOx during engine cold-start when exhaust temperatures are below 200°C. The objective of the project was to develop and demonstrate a multi-functional, catalyzed trap that enables vehicles with advanced combustion strategies to meet Tier 3 emissions standards while achieving the 150 °C challenge for sustained co-oxidation of HCs and CO and ≥90% NO trapping and release during warmup. Specifically, the multi-functional Lean HC+NOx (LHCNT) was developed for application in the exhaust aftertreatment of conventional diesel engines and engines having low temperature combustion (LTC) regimes. Activities included the design and synthesis of adsorbents and catalysts, screening and evaluation. Passive NOx absorbers (PNA), hydrocarbon (HC) traps, and oxidation catalysts (OC) were evaluated for use in series or as integrated devices. Predictive tools were developed utilizing the characterization and analysis of these materials, and an emission system was designed and optimized utilizing the catalyst systems. Microkinetic models were developed for the PNA for the simple NO-only feed and complex feed containing CO, H 2 , and model hydrocarbons (ethylene and dodecane). A first-principles, mechanistic-based model of the PNA was developed which utilized molecular-scale estimates (density functional theory) of energy barriers, mechanistic-based kinetics and realistic treatments of the flow and transport processes. Two new oxidation catalysts were developed (PdCu alloy, mixed copper-ceria-cobalt oxide), both of which significantly lessened the detrimental inhibition by CO on hydrocarbon and NO oxidation. A method for lessening the detrimental impact of CO on PNA activity was developed that involves use of an oxidation catalyst upstream of the PNA. The SwRI Ectolab TM burner system was applied to evaluate the baseline PNA material and confirmed performance comparable to the benchflow PNA studies using simulated exhaust. Spatially-resolved mass spectrometry (SpaciMS) was used to measure the transient spatial profiles of reacting species spanning the length of a three-function LHCNT containing PNA, HCT, and OC. The findings from this study provide diesel vehicle and catalyst companies valuable information to develop more cost effective emission control catalysts which helps to expand the use of more fuel efficient diesel power. The fundamental modeling and experimental tools and findings from this project can be applied to catalyst technologies used in the energy and chemical industries. The project led to 14 publications in the peer-reviewed literature with 2 additional currently under review. Finally, the project also led to training of several doctoral students who were placed in research jobs in industry and academia. Specifically, Mugdha Ambast (UH) has joined Cummins, Kevin Gu (UVa) has joined GM, and Abhay Gupta (UH) is to join Caterpillar.

02 PETROLEUM↗

Impact of Connected Communities

Buildings account for 35% of CO 2 emissions and almost 40% of the United States’ energy use. High-performance homes and neighborhoods play an important role in supporting efforts to decarbonize the US power system by 2035. Significant reductions in CO 2 emissions within the residential sector can be realized through electrification of loads paired with the flexibility created by leveraging smart Internet of Things (IoT) capabilities to shift energy use based on grid signals, thus improving generation/distribution efficiency and maximizing the use of renewable generation capacity. All of this can be achieved while allowing smart home appliances and equipment to meet homeowner needs – including reducing power bills - while optimizing operation in conjunction with the grid using novel control techniques. The Grid-Interactive Efficient Buildings Roadmap by the US Department of Energy’s (DOE’s) Building Technologies Office (BTO) notes that implementing grid-interactive efficient building (GEB) technology has the potential to reduce CO 2 emissions by 80 million tons/year—roughly equivalent to 17 million cars. To achieve this vision, the US Department of Energy’s Oak Ridge National Laboratory (ORNL)—in collaboration with Southern Company Research & Development, Alabama Power, Georgia Power, BTO and the US DOE’s Office of Electricity (OE) —is developing and demonstrating novel connected communities at two locations. Southern Company in turn engaged with industry partners, including design firms, residential developers, and residential HVAC and appliance manufacturers because their participation would be critical to the success of the initial research project, as well as the future scaling to the Southern Company service territory and beyond. Impacts of the Connected Communities projects in Alabama and Georgia are outlined including: energy, grid services and data management learnings; homeowner feedback; vendor engagement; adoption by utilities; technical, policy and business model challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗