Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronics analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Construction and Analysis of Electronic circuits

The Aviation Environmental Technical Branch produces many various types of aeronautical research that benefits the NASA mission for space exploration and in turn, produces new technology for our nation. One of the present goals of the Aviation Environmental Technical Branch is to create better engines for airplanes by testing supersonic jet propulsion and safe fuel combustion. During the summer of 2004, I was hired by Vincent Sattenvhite Chief executive of the Aviation Environmental Technical Branch to Assist Yves Lamothe with a fuel igniter circuit. Yves Lamothe is an electrical engineer who is currently working on safe fuel combustion testing. This testing is planned to determine the minimum ignition energy for fuel and air vapors of current and alternative fuels under simulated flight conditions. An air temperature bath will provide simulated flight profile temperatures and the heat fluxes to the test chamber. I was assigned with Yves to help complete the igniter circuit which consists of a 36k voltage supply an oscilloscope, and a high voltage transistor switch. During my tenure in the L.E.C.I.R.P. program I studied the basics of electricity and circuitry along with two other projects that I completed. In the beginning of my internship, I devote all of my time to research the aspects of circuitry so that I would be prepared for the projects that I was assigned to do. I read about lessons on; the basic physical concepts of electronics, Electrical units, Basic dc circuits, direct current circuit analysis, resistance and cell batteries, various types of magnetism , Alternating current basics, inductance, and power supplies. I received work sheets and math equations from my Mentor so that I could be able to apply these concepts into my work. After I complete my studies, I went on to construct a LED chaser circuit which displays a series of light patterns using a 555 timer. I incorporated a switch and motion detector into the circuit to create basic alarm system. This project challenged my ability to interpret a schematic and expand it. While I was still completing the LED chaser circuit I Also was given A Basic Stamp Toddler Robot to build and program. The Toddler robot can walk in 36 various styles using advanced robotics. I used many different programs to create movement and direction of the robot. Also the Toddler can use infrared vision to sense objects. This enables the robot to maneuver indefinitely without running into objects. During my tenure at the NASA Glen Research Center I definite utilized the NASA mission to educate. I learned valuable information to help in my up coming year as a freshman in college.

Thomas, Ashley N.↗

Electron-Diffraction Analysis of Growth of GaAs

Report describes experiments that used reflection high-energy-electron diffraction (RHEED) to investigate behavior of GaAs surfaces during and after growth by molecular-beam epitaxy (MBE). Experimental results show dynamic RHEED measurements useful both as probes of surface and growth kinetics and as methods for determining and reproducing surface and growth conditions.

Lewis, B. F.↗

Electron beam analysis induces Cl vacancy defects in a NaCl thin film

This work reports on the electron-induced modification of NaCl thin film grown on Ag(110). We show using low energy electron diffraction that electron beam bombardment leads to desorption and formation of Cl vacancy defects on NaCl surface. The topographic structure of these defects is studied using scanning tunneling microscopy (STM) showing the Cl defects as depressions on the NaCl surface. Most of the observed defects are mono-atomic vacancies and are located on flat NaCl terraces. Auger electron spectroscopy confirms the effect of electron exposure on NaCl thin films showing Cl atoms desorption from the surface. Using density functional theory taken into account the van der Waals dispersion interactions, we confirm the observed experimental STM measurements with STM simulation. Furthermore, comparing the adsorption of defect free NaCl and defective NaCl monolayer on Ag(110) surfaces, we found an increase of the adhesion energy and the charge transfer between the NaCl film and the substrate due to the Cl vacancy. In details, the adhesion energy increases between the NaCl film and the metallic Ag substrate from 30.4 meV Å –2 for the NaCl film without Cl vacancy and from 39.5 meV Å –2 for NaCl film with a single Cl vacancy. The charge transfer from the NaCl film to the Ag substrate is enhanced when the vacancy is created, from 0.63e – to 1.25e – .

Materials Science↗

Electron microprobe analysis program for biological specimens: BIOMAP

BIOMAP is a Univac 1108 compatible program which facilitates the electron probe microanalysis of biological specimens. Input data are X-ray intensity data from biological samples, the X-ray intensity and composition data from a standard sample and the electron probe operating parameters. Outputs are estimates of the weight percentages of the analyzed elements, the distribution of these estimates for sets of red blood cells and the probabilities for correlation between elemental concentrations. An optional feature statistically estimates the X-ray intensity and residual background of a principal standard relative to a series of standards.

Edwards, B. F.↗

Electron spectroscopy analysis

The Surface Science Laboratories at the University of Alabama in Huntsville (UAH) are equipped with x-ray photoelectron spectroscopy (XPS or ESCA) and Auger electron spectroscopy (AES) facilities. These techniques provide information from the uppermost atomic layers of a sample, and are thus truly surface sensitive. XPS provides both elemental and chemical state information without restriction on the type of material that can be analyzed. The sample is placed into an ultra high vacuum (UHV) chamber and irradiated with x-rays which cause the ejection of photoelectrons from the sample surface. Since x-rays do not normally cause charging problems or beam damage, XPS is applicable to a wide range of samples including metals, polymers, catalysts, and fibers. AES uses a beam of high energy electrons as a surface probe. Following electronic rearrangements within excited atoms by this probe, Auger electrons characteristic of each element present are emitted from the sample. The main advantage of electron induced AES is that the electron beam can be focused down to a small diameter and localized analysis can be carried out. On the rastering of this beam synchronously with a video display using established scanning electron microscopy techniques, physical images and chemical distribution maps of the surface can be produced. Thus very small features, such as electronic circuit elements or corrosion pits in metals, can be investigated. Facilities are available on both XPS and AES instruments for depth-profiling of materials, using a beam of argon ions to sputter away consecutive layers of material to reveal sub-surface (and even semi-bulk) analyses.

Gregory, John C.↗

New Insights into the Composition and Texture of Lunar Regolith Using Ultrafast Automated Electron-Beam Analysis

Sieved grain mounts of Apollo 16 drive tube samples have been examined using QEMSCAN - an innovative electron beam technology. By combining multiple energy-dispersive X-ray detectors, fully automated control, and off-line image processing, to produce digital mineral maps of particles exposed on polished surfaces, the result is an unprecedented quantity of mineralogical and petrographic data, on a particle-by-particle basis. Experimental analysis of four size fractions (500-250 microns, 150-90 microns, 75-45 microns and < 20 microns), prepared from two samples (64002,374 and 64002,262), has produced a robust and uniform dataset which allows for the quantification of mineralogy; texture; particle shape, size and density; and the digital classification of distinct particle types in each measured sample. These preliminary data show that there is a decrease in plagioclase modal content and an opposing increase in glass modal content, with decreasing particle size. These findings, together with data on trace phases (metals, sulphides, phosphates, and oxides), provide not only new insights into the make-up of lunar regolith at the Apollo 16 landing site, but also key physical parameters which can be used to design lunar simulants, and compute Figures of Merit for each material produced.

Rickman, Doug↗

Improved analysis of electron penetration and numerical procedures for space radiation shielding

Electron penetration calculational techniques are reviewed with regard to their suitability for shield analysis in future space operations. Methods based on the transmission factors of Mar are discussed and a correction term for low-energy electrons, which results in slightly conservative shield estimates, is derived. This modified Mar's method provides estimates of the dose for electrons that penetrate through shields of arbitrary elemental material with an atomic number greater than four. A complete computer algorithm is included.

Wilson, J. W.↗

A Graph Theory-Based Automated Twin Recognition Technique for Electron Backscatter Diffraction Analysis

Abstract The present article introduces a new software, Microstructure Evaluation Tool for Interface Statistics (METIS), that performs high-throughput microstructure statistical analysis from electron backscatter diffraction maps. Emphasis is placed on the detection of twin domains in hexagonal close-packed metals. The numerical framework on which METIS is built leverages graph theory, group structures, and associated numerical algorithms to automatically detect twins and unravel both their intrinsic characteristics features and those pertaining to their interactions. The proposed graphical interface allows for the detection and correction of unlikely twin/parent associations rendering the approach applicable to highly deformed microstructures. Twin statistics and microstructural data are classified and saved in a relational database that can be interrogated via either GUI or SQL requests to reveal a wide spectrum of features of the microstructure. Illustration of the approach is performed in the case of zirconium.

36 MATERIALS SCIENCE↗

Electronic component reliability analysis by data reduction system

Mechanized data reduction system has been designed to take advantage of the data handling capacity of computers and to reduce voluminous and unrelated test and performance data to a format useful for the rapid analysis of electronic component reliability.

Dimm, R. M.↗

Observation of a heated electron population associated with the 6300 A SAR arc emission

Conjunctive observations of the Dynamics Explorer satellite pair and the Pacific Northwest Laboratory scanning photometer unit at Richland, WA have allowed identification of the low energy, heated, electron population associated with the 6300 A Stable Auroral Red (SAR) arc emission. Measurements over the SAR arc on day 296 of 1981 show an enhanced flux in the low altitude 5-12 eV electrons. Analysis of this electron population shows them to be fairly Maxwellian, with temperatures on the order of 9900 + or - 1100 K and an earthward field aligned velocity of approximately 275 + or - 60 km/sec. The electrons are not accompanied by ion precipitation. The ion loss cone is empty at least as high as 6000 km. This fact may cast some doubt as to the role of the ring current ions in the SAR arc production.

Gurgiolo, C.↗

Cutoff probe using Fourier analysis for electron density measurement

This paper proposes a new method for cutoff probe using a nanosecond impulse generator and an oscilloscope, instead of a network analyzer. The nanosecond impulse generator supplies a radiating signal of broadband frequency spectrum simultaneously without frequency sweeping, while frequency sweeping method is used by a network analyzer in a previous method. The transmission spectrum (S21) was obtained through a Fourier analysis of the transmitted impulse signal detected by the oscilloscope and was used to measure the electron density. The results showed that the transmission frequency spectrum and the electron density obtained with a new method are very close to those obtained with a previous method using a network analyzer. And also, only 15 ns long signal was necessary for spectrum reconstruction. These results were also compared to the Langmuir probe's measurements with satisfactory results. This method is expected to provide not only fast measurement of absolute electron density, but also function in other diagnostic situations where a network analyzer would be used (a hairpin probe and an impedance probe) by replacing the network analyzer with a nanosecond impulse generator and an oscilloscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intracellular trafficking of superparamagnetic iron oxide nanoparticles conjugated with TAT peptide: 3-dimensional electron tomography analysis

Highlights: Black-Right-Pointing-Pointer We study the intracellular localisation of TAT-SPIONs using 3-D electron tomography. Black-Right-Pointing-Pointer 3-D images of TAT-SPIONs in a cell are clearly shown. Black-Right-Pointing-Pointer Release of TAT-SPIONs from endocytic vesicles into the cytoplasm is clearly shown. -- Abstract: Internalisation of nanoparticles conjugated with cell penetrating peptides is a promising approach to various drug delivery applications. Cell penetrating peptides such as transactivating transcriptional activator (TAT) peptides derived from HIV-1 proteins are effective intracellular delivery vectors for a wide range of nanoparticles and pharmaceutical agents thanks to their amicable ability to enter cells and minimum cytotoxicity. Although different mechanisms of intracellular uptake and localisation have been proposed for TAT conjugated nanoparticles, it is necessary to visualise the particles on a 3-D plane in order to investigate the actual intracellular uptake and localisation. Here, we study the intracellular localisation and trafficking of TAT peptide conjugated superparamagnetic ion oxide nanoparticles (TAT-SPIONs) using 3-D electron tomography. 3-D tomograms clearly show the location of TAT-SPIONs in a cell and their slow release from the endocytic vesicles into the cytoplasm. The present methodology may well be utilised for further investigations of the behaviours of nanoparticles in cells and eventually for the development of nano drug delivery systems.

60 APPLIED LIFE SCIENCES↗

A multiple gap plasma cathode electron gun and its electron beam analysis in self and trigger breakdown modes

In the present paper, a pseudospark discharge based multiple gap plasma cathode electron gun is reported which has been operated separately in self and trigger breakdown modes using two different gases, namely, argon and hydrogen. The beam current and beam energy have been analyzed using a concentric ring diagnostic arrangement. Two distinct electron beams are clearly seen with hollow cathode and conductive phases. The hollow cathode phase has been observed for ∼50 ns where the obtained electron beam is having low beam current density and high energy. While in conductive phase it is high current density and low energy electron beam. It is inferred that in the hollow cathode phase the beam energy is more for the self breakdown case whereas the current density is more for the trigger breakdown case. The tailor made operation of the hollow cathode phase electron beam can play an important role in microwave generation. Up to 30% variation in the electron beam energy has been achieved keeping the same gas and by varying the breakdown mode operations. Also, up to 32% variation in the beam current density has been achieved for the trigger breakdown mode at optimized trigger position by varying the gas type.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gaussian process analysis of electron energy loss spectroscopy data: multivariate reconstruction and kernel control

Abstract Advances in hyperspectral imaging including electron energy loss spectroscopy bring forth the challenges of exploratory and physics-based analysis of multidimensional data sets. The multivariate linear unmixing methods generally explore similarities in the energy dimension, but ignore correlations in the spatial domain. At the same time, Gaussian process (GP) explicitly incorporate spatial correlations in the form of kernel functions but is computationally intensive. Here, we implement a GP method operating on the full spatial domain and reduced representations in the energy domain. In this multivariate GP, the information between the components is shared via a common spatial kernel structure, while allowing for variability in the relative noise magnitude or image morphology. We explore the role of kernel constraints on the quality of the reconstruction, and suggest an approach for estimating them from the experimental data. We further show that spatial information contained in higher-order components can be reconstructed and spatially localized.

36 MATERIALS SCIENCE↗

py4DSTEM: A Software Package for Four-Dimensional Scanning Transmission Electron Microscopy Data Analysis

Scanning transmission electron microscopy (STEM) allows for imaging, diffraction, and spectroscopy of materials on length scales ranging from microns to atoms. By using a high-speed, direct electron detector, it is now possible to record a full two-dimensional (2D) image of the diffracted electron beam at each probe position, typically a 2D grid of probe positions. These 4D-STEM datasets are rich in information, including signatures of the local structure, orientation, deformation, electromagnetic fields, and other sample-dependent properties. However, extracting this information requires complex analysis pipelines that include data wrangling, calibration, analysis, and visualization, all while maintaining robustness against imaging distortions and artifacts. In this paper, we present py4DSTEM, an analysis toolkit for measuring material properties from 4D-STEM datasets, written in the Python language and released with an open-source license. We describe the algorithmic steps for dataset calibration and various 4D-STEM property measurements in detail and present results from several experimental datasets. We also implement a simple and universal file format appropriate for electron microscopy data in py4DSTEM, which uses the open-source HDF5 standard. We hope this tool will benefit the research community and help improve the standards for data and computational methods in electron microscopy, and we invite the community to contribute to this ongoing project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗