Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The incommensurate modulation of tetragonal tungsten bronze quantified by high resolution 4D STEM

Many members of the tetragonal tungsten bronze (TTB) family of oxides display an incommensurate periodic lattice distortion, the nature of which has been the subject of some controversy. Here we present a study of this structural modulation in the relaxor ferroelectric Ba 5 SmSn 3 Nb 7 O 30 (BSSN) by quantitative scanning transmission electron microscopy (STEM). Additionally, we characterize the modulation in BSSN by employing a fast, pixelated direct electron detector to perform high resolution phase contrast STEM imaging of the crystalline lattice. By quantitatively analyzing the images, we visualize the atomic structural correlations present in the material on both the cation and anion sublattices. This analysis reveals the incommensurate structure to have an octahedral tilting pattern and cooperative A2 site cation displacements, analogous to an Ama2 commensurate cell. Finally, we show that the modulation is composed of a structural motif with a period of 3 x $d_{1\bar{1}0}$ and modified by discommensurations, likely arise from frustrated octahedral tilting in the odd-valued periodicity.

Differential phase contrast↗

A method for crystallographic mapping of an alpha-beta titanium alloy with nanometre resolution using scanning precession electron diffraction and open-source software libraries

An approach for the crystallographic mapping of two-phase alloys on the nanoscale using a combination of scanned precession electron diffraction and open-source python libraries is introduced in this paper. This method is demonstrated using the example of a two-phase α/β titanium alloy. The data were recorded using a direct electron detector to collect the patterns, and recently developed algorithms to perform automated indexing and analyse the crystallography from the results. Very high-quality mapping is achieved at a 3 nm step size. The results show the expected Burgers orientation relationships between the α laths and β matrix, as well as the expected misorientations between α laths. A minor issue was found that one area was affected by 180° ambiguities in indexing occur due to this area being aligned too close to a zone axis of the α with twofold projection symmetry (not present in 3D) in the zero-order Laue Zone, and this should be avoided in data acquisition in the future. Nevertheless, this study demonstrates a good workflow for the analysis of nanocrystalline two- or multi-phase materials, which will be of widespread use in analysing two-phase titanium and other systems and how they evolve as a function of thermomechanical treatments.

36 MATERIALS SCIENCE↗

Electromagnetic wave absorption of multifunctional cementitious composites incorporating polyvinyl alcohol (PVA) fibers and fly ash: Effects of microstructure and hydration

Highlights: • The cementitious composite shows excellent wide-band electromagnetic wave absorption in a frequency range of 2–18 GHz. • The PVA fibers and the fly ash change the dielectric properties of the cementitious composite by Debye polarization. • The iron oxide of the cementitious binders contributes to the magnetic properties of the composites. • The impacts of the microstructure and the hydration of the cementitious composite on its microwave absorption are analyzed. This paper devises a novel method for the adjustment of the pore structure and the hydration of cement to improve the electromagnetic wave absorption of the cementitious composites incorporating polyvinyl alcohol (PVA) fibers and fly ash in a frequency range of 2–18 GHz. The underlying mechanism of the absorption is investigated to explore the possibility of the structural and functional integration of these composites. The electromagnetic parameters of the prepared cementitious composites and those of the raw materials are analyzed in a frequency range of 0.5–18 GHz. Moreover, the pore structure and the chemical environment of the cementitious composites are examined by mercury intrusion porosimetry (MIP), back-scattered electron detector (BSE), and X-ray photoelectron spectroscopy (XPS). The results indicate that the PVA fibers and the high-volume fly ash have a positive effect on electromagnetic wave absorption of the cementitious composites through the adjustment of their pore structure and hydration.

36 MATERIALS SCIENCE↗

From Gargamelle to MINERvA: exploring the structure of the nucleon with neutrinos

Neutrino scattering experiments have been exploring the structure of the nucleon with Deep-Inelastic Scattering for over 50 years. Although hints of nucleon structure were available using CERN’s first neutrino beam in the 1960s, the study actually started quantitatively in the early 1970s with the Gargamelle heavy liquid bubble chamber that produced first neutrino confirmation of scaling. This study of nucleon structure continued with both bubble chambers and more massive electronic detectors that, with higher energy neutrino beams and $Q^2$ reach, examined the breaking of this scaling while testing Quantum Chromodynamics. Here, a significant factor when including neutrino explorations of nucleon structure in the overall picture is that to gather significant statistics, neutrino experiments have had to use heavier nuclear targets. It has been experimentally demonstrated that the structure of the nucleon in the nuclear environment is indeed different than the free nucleon structure. Understanding this modified structure has played an important part in the experimental and theoretical exploration of nucleon structure by neutrinos and is one of the important goals of the on-going MINERvA experiment at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Internship In ISR-1 [Slides]

ISR-1 is the Space Science and Applications division, so much of what we work with involves satellites, detectors, electronics, radiation, etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Analysis and Mitigation of Pulse-Pile-Up Artifacts in Plasma Pulse-Height X-ray Spectra

Pulse pile-up in pulse-height energy analyzers increases when the incident rate of pulses increases relative to the inverse of the dead time per pulse of the detection system. Changes in the observed energy distributions with incident rate and detector-electronics-formed pulse shape then occur. Here, we focus on weak high energy tails in X-ray spectra, important for measurements on partially ionized, warm (50–500 eV average electron energy), pure hydrogen plasma. A first-principles two-photon pulse-pile-up model is derived specific to trapezoidal-shaped pulses; quantitative agreement is found between the measurements and the model’s predictions. The model is then used to diagnose pulse-pile-up tail artifacts and mitigate them in relatively low count-rate spectra.

2-photon↗

System and method for neutron and gamma radiation detection using non-homogeneous material scintillator

A scintillator system is disclosed for detecting incoming radiation. The system makes use of a scintillator structure having first and second dissimilar materials. The first dissimilar material emits a first color of light and the second dissimilar material emits a second color of light different from the first color of light. Either one, or both, of the first or second colors of light are emitted in response to receipt of the incoming radiation. A plurality of light detectors is disposed in proximity to the scintillator structure for detecting the first and second different colors of light and generating output signals in response thereto. A detector electronics subsystem is responsive to the output signals and provides an indication of colors emitted by the scintillator structure to infer at least one property of the incoming radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LSU-Argonne conversion electron spectrometer: A new detector for the X-Array and SATURN decay station

In this study, a new conversion electron detector has been commissioned at the ATLAS/ CARIBU facility at Argonne National Laboratory. The LSU-Argonne Conversion Electron Spectrometer (LACES) is a LN 2 -cooled Si(Li) detector system designed to be incorporated into a decay station that comprises the dedicated HPGe clover array with a box geometry (X -Array) and the Scintillator and Tape Using Radioactive Nuclei (SATURN) device. This integration enables simultaneous measurements of conversion electrons and gamma-rays in decay experiments, yielding novel information on transition multipolarities, electric monopole transitions, and isomeric states that decay mostly via conversion electrons. A measurement of the energy resolution of LACES yielded 2.3-keV FWHM at 975 keV for electrons and 1.3-keV FWHM at 75 keV for X-rays. A detailed study of the absolute detection efficiency (at 5 mm from the source) was performed, where this quantity was determined experimentally in the range of electron transition energies between 25.5 keV and 1047.8 keV and subsequently simulated using the GEANT4 code. Measurement and simulations are found to be in excellent agreement. A precise characterization, for this type of detector system, of the absolute detection efficiency for such a wide energy range is reported for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

Measurements of electrons from 𝜈𝑒 interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectra is derived, and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50 MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L , in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ~70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction and Commissioning of Gas Electron Multiplier (GEM) Detectors in Advanced Assembly Design for Low-Energy Applications at High Rates and Analysis of GEM Data From the Muse Experiment at PSI

The search beyond the Standard Model explores dark matter and a potential fifth force. DarkLight@ARIEL investigates the dark photon as a mediator between ordinary and dark matter. The experiment aims to measure the process e?Ta ? e?TaX ? e?Ta(e?e+), by detecting a charged lepton pair in the final state. The spectrometers will be instrumented with Gas Electron Multiplier (GEM) detectors with minimal material budget for tracking. A novel GEM construction technique is employed for fabricating 25 cm x 40 cm GEM detectors, where all layers are mechanically stretched and assembled within a double frame. The dissertation outlines physics motivation, methods, experimental setup, and the role of GEM detectors in DarkLight. A comprehensive discussion on GEM detectors, focusing on the "NS2" technique, including design, parts, assembly, testing, and performance evaluation will be discussed. The proton has garnered attention due to discrepancies in measuring its charge radius using muonic hydrogen and electron-based methods. The 2010 muonic hydrogen measurement of the proton charge radius Rp = 0.84184(67) fm, showed a significant 7? discrepancy compared to the previously known value of Rp = 0.8775(51) fm, giving rise to the proton radius puzzle. Through simultaneous measurements of e ? p and ? ? p elastic scattering, MUSE facilitates a precise and direct comparison of the proton radius. The physics background of the proton radius puzzle, measurement techniques, the approach adopted by the MUSE experiment, its significance and the experimental setup will be discussed. Furthermore, the role of GEM detectors, along with an in-depth analysis of their data and efficiency will be discussed and evaluated.

Mohammed Prem Nazeer, Sahara↗

Advanced silicon tracking detector developments for the future Electron-Ion Collider

The proposed Electron-Ion Collider (EIC) will operate high-luminosity high-energy electron+proton and electron+nucleus collisions at the collision energies from 20 GeV to 141 GeV to solve several fundamental questions in the high energy and nuclear physics fields. Its instantaneous luminosity can reach 10 33-34 cm -2 s -1 and the bunching crossing rate is around 10 ns. The EIC project has received CD1 approval from the US DOE in 2021 and moves toward the machine design and preparation for construction. To realize various particle measurements with high precision at the future EIC, a low material-budget and high-granularity silicon vertex and tracking detector with fine spatial and momentum resolutions and nearly 4π solid angle coverage is desired. The Monolithic Active Pixel Sensor (MAPS) and AC Coupled Low Gain Avalanche Diode (AC-LGAD) technologies stand out of several advanced technology options for the EIC silicon vertex and tracking detector subsystems. The MAPS technology has advanced features of low material budget, low power consumption, good radiation resistance and fine spatial resolution. The AC-LGAD technology can achieve fast timing resolution. Latest studies and progress of the EIC silicon vertex and tracking detector conceptual design, performance validations in simulation and ongoing MAPS and AC-LGAD R&D will be shown. Furthermore, schedule and plan of the EIC project detector development will be discussed as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of detectors at the electron ion collider with artificial intelligence

Abstract Artificial Intelligence (AI) for design is a relatively new but active area of research across many disciplines. Surprisingly when it comes to designing detectors with AI this is an area at its infancy. The electron ion collider is the ultimate machine to study the strong force. The EIC is a large-scale experiment with an integrated detector that extends for about ±35 meters to include the central, far-forward, and far-backward regions. The design of the central detector is made by multiple sub-detectors, each in principle characterized by a multidimensional design space and multiple design criteria also called objectives. Simulations with Geant4 are typically compute intensive, and the optimization of the detector design may include non-differentiable terms as well as noisy objectives. In this context, AI can offer state of the art solutions to solve complex combinatorial problems in an efficient way. In particular, one of the proto-collaborations, ECCE, has explored during the detector proposal the possibility of using multi-objective optimization to design the tracking system of the EIC detector. This document provides an overview of these techniques and recent progress made during the EIC detector proposal. Future high energy nuclear physics experiments can leverage AI-based strategies to design more efficient detectors by optimizing their performance driven by physics criteria and minimizing costs for their realization.

Instruments & Instrumentation↗

Forward silicon vertex/tracking detector design and R$\&$D for the future Electron-Ion Collider

The proposed high-luminosity high-energy Electron-Ion Collider (EIC) will provide a clean environment to precisely study several fundamental questions in the fields of high-energy and nuclear physics . A low material budget and high granularity silicon vertex/tracking detector is critical to carry out a series of hadron and jet measurements at the future EIC especially for the heavy flavor product reconstruction or tagging. The conceptual design of a proposed forward silicon tracking detector with the pseudorapidity coverage from 1.2 to 3.5 has been developed in integration with different magnet options and the other EIC detector sub-systems. The tracking performance of this detector enables precise heavy flavor hadron and jet measurements in the hadron beam going direction. The detector R&D for the proposed silicon technology candidates: Low Gain Avalanche Diode (LGAD) and radiation hard depleted Monolithic Active Pixel Sensor (MALTA), which can provide good spatial and timing resolutions, is underway. Bench test results of the LGAD and MALTA prototype sensors will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Michel Electron Selection with SPINE for DUNE Far Detector Simulation

Michel electrons are a valuable input for particle detector calibration due to their consistent kinetic energy distribution. This report details the evaluation of a Michel electron identification method's application to simulated data from the DUNE (Deep Underground Neutrino Experiment) far detector. This method, which relies on the neural network-based particle classification software SPINE (Scalable Particle Imaging with Neural Embeddings), was developed and calibrated using simulated data for the SBND (Short-Baseline Neutrino Detector) experiment before being applied to simulated DUNE data from a 1x2x6 subset of far detector modules.

Wilson, Dante [Colorado State U.]↗

Scientific computing plan for the ECCE detector at the Electron Ion Collider

The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing these challenges in the process of producing a complete detector proposal based upon detailed detector and physics simulations. Here, in this document, the software and computing efforts to produce this proposal are discussed; furthermore, the computing and software model and resources required for the future of ECCE are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗