Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of electron beam irradiation on CrMnV and CrMnTiV high entropy alloys: Nano-mechanical, structural, and thermodynamic perspectives

Beam exit windows are crucial components of any particle accelerator as they provide an interface between the beamline vacuum and target material at atmospheric media. For high beam power machines, special materials and designs are required to withstand high radiation and mechanical loads, while minimizing energy loss during transition and maximizing window lifetime. This research investigates the impact of electron beam exposure to bulk CrMnV and CrMnTiV high entropy alloys (HEAs) with the primary goal of identifying suitable candidate materials for the design of robust and durable exit window settings. The selection criteria include intrinsic characteristics, power dissipation, and mechanical responses. According to the thermodynamic calculations, both equiatomic CrMnV and the addition of 7% of Ti with equiatomic CrMnV yield solid-solutions phases. The structural and mechanical properties of CrMnV and CrMnTiV samples were tested using field emission scanning electron microscopy, atomic force microscopy, scanning electron microcopy with energy dispersive x-ray spectroscopy, x-ray diffraction, and nanoindentation before and after exposure to a dose of ~66 kGy from a 10 MeV e-beam accelerator. Despite exhibiting beam transmission characteristics comparable to Cr and V, the indentation hardness of HEAs exceeded that of the Cr and V samples by five to six times. The examination of the CrMnTiV irradiated samples revealed organized deformation patterns depicting new features, which we suspect twinning and twin boundaries due to the addition of Ti to CrMnV. Ti, a hexagonal-close-packed crystal structure, is commonly known for deformation twinning behavior.

36 MATERIALS SCIENCE↗

Nonparaxial propagation of an intense relativistic electron beam through dense media

An envelope equation is used to explore the propagation of a focused electron beam through dense conductive media like partially ionized high-pressure gas, metal vapor plumes from beam-target interactions, or low-density solid-phase targets. Envelope equations have been a most useful tool for predicting experimental results of beam propagation in gas, and they are refined for the general problem of propagation through a dense medium. The envelope equation is modified to account for the large beam divergence resulting from multiple scattering. The envelope code results are in qualitative agreement with published experimental data. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Evaluation of the interfacial bonding strength between hafnia and silica layers deposited by electron-beam evaporation

Factors contributing to the mechanical strength of multilayer optical coatings involving alternating layers of electron-beam evaporated hafnia and silica is investigated. It is observed that upon rupture resulting from nanosecond laser damage, fragments consisting of layer pairs are produced. These pairs are formed as a result of a strong asymmetry in adhesion strength between interfaces, leading to preferential delamination at interfaces where silica is deposited on hafnia, and not the reverse, despite the fact that both interface types consist of the same pair of materials. The observed disparity in adhesion strength was further studied using nanomechanical scratch tests, revealing loads at which fracture occurs, and fracture morphology, both of which are highly dependent on deposition order. Based on these measurements, along with the morphological analysis of the nanostructure of the coatings, we conclude that the surface microstructure in each coating layer affects its adhesion strength with the succeeding layer. The findings outlined here are particularly relevant to the production of large aperture, high-performance optics designed for use in next-generation lasers.

adhesion strength↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Resistive hose modes in tokamak runaway electron beams II

Resistive hose instabilities of runaway electron (RE) beams immersed in resistive background plasmas are examined with analytic and numerical calculations. The RE beam-plasma equilibria considered are characteristic of the situation observed post-thermal quench in a tokamak disruption. An analytic linear dispersion relation is presented for the case of a uniform RE current density profile with a sharp boundary in cylindrical geometry. Initial value linear calculations for a more general profile in toroidal geometry find that reducing aspect ratio increases the resistive hose mode growth rates with fixed safety factor profile. Nonlinear calculations in cylindrical and toroidal geometry find that the resistive hose instability-driven fluctuations relax the gradient of the current density profile. In toroidal geometry, changes to the magnetic topology are observed as a result of the resistive hose activity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron beam irradiation effects on bulk metals: a comparative study of polycrystalline versus single-crystalline structures

This study investigates the effects of electron beam (e-beam) irradiation on the mechanical and structural properties of eight bulk metallic samples, comprising both polycrystalline (PC) and single-crystalline (SC) forms of Ni, Cr, V, and Ti. These metals were evaluated as potential candidates for beam exit windows in high-power (MW-class) particle accelerators. The primary objective is to identify metals capable of withstanding the conditions of high-power/MW-class e-beam accelerators and serve effectively as exit windows. Selection criteria were based on each metal’s intrinsic properties, power dissipation capability, and irradiation-induced changes in mechanical behavior, including hardness, elastic modulus, and defect density. Comprehensive characterization was conducted using field-emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM–EDS), X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), selected area electron diffraction (SAED), and nanoindentation, performed both before and after exposure to a ~¿66 kGy dose from a 10 MeV e-beam accelerator. Results revealed that e-beam irradiation induced hardening in PC Ni, whereas PC Ti, commonly used in beam exit windows, exhibited softening. The observed softening in PC Ti is attributed to grain coarsening, elongation, and the formation of twins and twin boundaries, in contrast to the smaller, compressed grains in the pristine (Pr) PC Ti samples, consistent with the Hall–Petch relationship. The stresses due to twinning are small and insignificant in influencing the overall hardening of the PC Ti irradiated sample when compared to the stresses due to the dislocation density. Conversely, SC Ti samples exhibited irradiation-induced hardening. The SC Ti irradiated samples developed additional irradiation-induced modifications in crystallographic texture of (100), (101), (110), (200), (112), (004), and (211) as evidenced from the XRD results, which could probably explain the hardening effect that is caused by irradiation.

36 MATERIALS SCIENCE↗

Crystal Orientation and Defect Mapping in Electron-Beam-Sensitive Zeolites with Near-Axis Transmission Kikuchi Diffraction

Porous materials are vital in catalysis, energy conversion, and environmental remediation. Understanding structural heterogeneity in zeolites is key to linking synthesis, framework intergrowths, and catalytic performance, yet current methods for phase identification and spatial mapping lack sufficient resolution or throughput. We present a high-throughput approach using near-axis transmission Kikuchi diffraction in a scanning electron microscope, achieving high phase and spatial resolution for electron-beam-sensitive zeolites, including ZSM-5 and, for the first time, Zeolite A. Here, this method enables direct visualization of intergrowth features that critically affect catalytic and adsorption behavior, bridging the gap between ensemble-averaged X-ray diffraction and high-resolution but low-throughput transmission electron microscopy. Combining nanoscale mapping with statistical sampling is highly suited for machine-learning pipelines guiding new structure function understanding and could be extended to other beam-sensitive porous materials such as metal–organic or covalent–organic frameworks.

crystallography↗

On Possibilities of Using Edge Radiation for X-ray and Electron Beam Diagnostics at Bending Magnet Beamlines of NSLS-II

Spectral flux density distributions of long-wavelength Edge Radiation, i.e. radiation generated by relativistic electrons at edges of bending magnets in a storage ring are described, both analytically and numerically. Possibilities of using this radiation for the alignment of optical components of bending magnet beamlines at NSLS-II and for non-destructive X-ray and electron beam diagnostics at these beamlines are discussed.

43 PARTICLE ACCELERATORS↗

Multimodal Defect Imaging of Pure Tungsten Components Fabricated via Electron Beam Powder Bed Fusion

The utilization of additive manufacturing (AM) techniques for refractory materials in high-temperature environments has significantly expanded because of the ability to fabricate geometrically complex components. Electron beam powder bed fusion (EB-PBF), which provides lower residual stress, a cleaner vacuum environment, and better efficiency for high melting point, is one of the best-suited AM methods to produce advanced refractory components. However, the property variation attributed to the heterogeneous microstructure and process-induced defects has hindered the widespread adoption of EB-PBF-produced material like tungsten. While numerous in-situ monitoring and defect detection methods have been demonstrated for EB-PBF, a workflow that compares and evaluates process-induced abnormalities from different imaging perspectives is still limited. This study examines a feature-embedded tungsten component manufactured via the EB-PBF process to demonstrate the defect detection capabilities of a multimodal defect imaging workflow. The predefined and process-induced defects are evaluated by harnessing various imaging techniques, including in-situ electron imaging, layerwise near-infrared (NIR) imaging, post-build high-energy x-ray computed tomography (CT), and conventional destructive metallography. The results highlight the strengths and limitations of distinctive defect imaging techniques concerning specific defect types, sizes, and conditions. It was found that electron imaging can provide more abnormal detection capabilities while maintaining a higher measuring accuracy, against the conventional metallography in this case study, compared with NIR and CT imaging techniques.

36 MATERIALS SCIENCE↗

Manufacturing Full-Scale High Gradient Copper Accelerators: Electron Beam Welding and Allied Processes

This DOE ARDAP-funded study examines the technical and business feasibility of manufacturing high-gradient normal conducting RF (NCRF) copper accelerating structures using electron beam welding (EBW) instead of conventional high-temperature brazing. The core motivation is material performance: brazing softens copper significantly, while hard copper alloys have demonstrated ~75% higher operational gradients in SLAC tests, making cold-joining techniques highly attractive. EBW, applied to split-cell (half or quadrant) structure designs, preserves copper hardness away from the weld joint and simplifies machining — but industrial process optimization remains immature and a substantial learning curve is expected. The business case was modeled for two scenarios: a greenfield EBW linac company (> $10M upfront costs, viable above ~30 units/year) and an EBW division added to an existing accelerator firm to reduce risk and upfront costs, at the expense of being less optimal structure for the higher volume production. The study concludes that without a significant increase in demand, private investment alone cannot sustain this capability, and recommends federal support through R&D grants, procurement incentives, and CAPEX cost-sharing to incubate domestic EBW-NCRF manufacturing — with the existing-company model.

43 PARTICLE ACCELERATORS↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Effect of threshold parameters on infrared segmentation methods for porosity detection in electron beam powder bed fusion

In-situ process monitoring has seen significant interest in additive manufacturing to address qualification and certification goals. This is especially prevalent in metal powder bed fusion processes such as electron beam powder bed fusion (PBF-EB), with layer-wise infrared imaging being commonly used to detect defects. Here, this work compares two different segmentation methods (static thresholding and statistical thresholding) used for detecting porosity from in-situ infrared imaging data for PBF-EB. Samples were manufactured at a variety of focus offset values to induce porosity. Then, the segmented infrared images were compared to ex-situ X-ray computed tomography scans, which served as a ground-truth reference for objective evaluation. Through this analysis framework, the influential parameters, static threshold and N-value (number of standard deviations above the mean pixel value), respectively, for both image segmentation methods were analyzed and compared for their effects on porosity detection. With optimal parameter settings, the two methods had similar porosity detection performance, but the statistical method performed better under a larger variety of parameter settings.

Infrared imaging↗

Large Angle Rocking Beam Electron Diffraction Utilizing Electron Direct Detector

Electron diffraction of a crystal is fundamentally a function of the potential of that crystal. The intensity of electron diffraction patterns is, as a result, sensitive to the charge density of atoms and bonding inside crystals. Experimentally, the traditional method to probe this information is quantitative Convergent Beam Electron Diffraction (CBED). Quantitative CBED or QCEBD is a method which uses dynamic diffraction theory to quantify CBED intensities and to extract information about crystal structure and bonding. The sensitivity of dynamical scattering is leveraged to measure crystal symmetry and crystal structure factors. At its limit, electron structure factors are measured at high accuracy allowing access to chemical bonding information, which corroborate theoretical calculations through multipole model refinements of the experimental charge density. The primary limit to QCBED is the requirement of a non-overlapping convergent beam. This subsequently limits QCBED to crystals with small unit cells which are stable under the focused probe.

Busch, Robert↗

Direct Acceleration of an Electron Beam with a Radially Polarized Long-Wave Infrared Laser

Direct laser acceleration with radially polarized lasers is an intriguing variant of laser-based particle acceleration that has the potential of offering GeV/cm-level energy while avoiding the instabilities and complex beam dynamics associated with plasma wakefield accelerators. A major limiting factor is the difficulty of generating high-power radially polarized beams. In this paper, we propose the use of CO2-based long-wave infrared (LWIR) lasers as a driver for direct laser acceleration, as the polarization insensitivity of the gain medium allows a radially polarized beam to be amplified. Additionally, the larger waist sizes, Rayleigh lengths, and pulse lengths associated with the long wavelength could improve the injection efficiency of the electron beam. By comparing acceleration simulations using a near-infrared laser and an LWIR laser, we show that the injection efficiency is indeed improved by up to an order of magnitude with the longer wavelength. Furthermore, we show that even sub-TW peak powers with an LWIR laser can provide MeV-level energy gains. Thus, radially polarized LWIR lasers show significant promise as a driver of a direct laser-driven demonstration accelerator.

43 PARTICLE ACCELERATORS↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗