At least 73 records · Page 4

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

High-Vacuum Triboelectric Charging of Space Materials

In the high-vacuum environment of space and the surface of the moon, static electricity on surfaces lacks the atmospheric dissipation mechanisms found on earth. As a result, the ubiquitous triboelectric charging mechanism can lead to high levels of charge on surfaces. This static charge can result in damage to sensitive devices, interfere with communications, and electrostatic levitation of lunar dust. At the NASA Electrostatics and Surface Physics Laboratory (ESPL), we use different apparatuses and techniques to tribo-charge materials in high-vacuum (10-5 torr), including a tribo-robot and a triboelectric regolith-material stage (TRMS). The tribo-robot is used to rub two materials together, and fieldmeters and electrometers can be used to determine how much charge is on the materials. The TRMS is used to drag different materials onto a bed of lunar simulant. This system is used to characterize how materials may interact with lunar dust using fieldmeters, electrometers, and laser scattering. Using these methods, we are building a database of how different space materials charge when contacting each other at high-vacuum, and how materials triboelectrically interact with the lunar surface.

Joseph Toth↗

Apparatus for simultaneous ion counting and current recording in mass spectrometry

Ion counting system is coupled to the last dynode of an Allen-type electron multiplier on the mass analyzer of a double focusing mass spectrometer. This leaves the anode available for an electrometer, making possible simultaneous measurements. Coupling is achieved by a ferrite core transformer and associated circuitry.

Kohl, F. J.↗

Experiment D010: Ion sensing attitude control

The feasibility of an attitude control system that uses environmental positive ions and an electrostatic detection system to measure spacecraft pitch and yaw is studied. The secondary objective was to measure the spatial and temporal variations of ambient positively charged particles along the orbital path of the Gemini 10 and 12 spacecrafts. The results proved that the use of a horizon detector in conjunction with pitch and yaw sensors would facilitate complete description of the spacecraft position and attitude. Furthermore, with the addition of a servosystem, the unit could be used as a complete automatic attitude-control system that would be applicable from the lowest satellite altitudes up to at least 10 earth radii. Also, results established that the charge density along the trajectory of the satellite could be determined by transmission of output voltages from the individual electrometers.

Sagalyn, R. C.↗

Experimental determination of cosmic ray charged particle intensity profiles in the atmosphere

Absolute cosmic-ray free air ionization and charged particle fluxes and dose rates throughout the atmosphere were measured on a series of balloon flights that commenced in 1968. Argon-filled ionization chambers equipped with solid-state electrometers, with different gas pressures and steel wall thicknesses, and a pair of aluminum-wall Gm counters have provided the basic data. These data are supplemented by measurements with air-filled and tissue equivalent ionization chambers and a scintillation spectrometer. Laboratory experiments together with analyses of the theoretical aspects of the detector responses to cosmic radiation indicate that these profiles can be determined to an overall accuracy of + or - 5 percent.

Lowder, W. M.↗

An investigation of geometry and noise corrections to San Marco-C neutral atmospheric composition experiment data

The problem of the calculation of ambient densities from San Marco-C neutral atmospheric composition experiment data is considered. A brief description is given of the data measurement method, followed by a description of both the theoretical and experimental data curves. Geometry, electrometer distortions, and noise effects are then studied in terms of their effects on the ideal data form. From these considerations two data reduction methods are evolved. The first is an iterative integration technique that exploits the symmetry of the experimental data about the minimum angle of attack. For the analysis of geometry effects, a second method using interval averaging was developed and studied.

Curtis, S. A.↗

Instrumentation for measuring low-level currents/voltages

Instrumentation consists of high-output resistance voltage measuring amplifier (electrometer) and current-to-frequency converter (current digitizer) coupled to set of timers and counters. Digital display of time-averaged signals with amplitudes varying over 11 decades is possible.

Richmond, R. G.↗

Average plasma environment at geosynchronous orbit

The average plasma environment at geosynchronous orbit (GSO) is derived from a whole year's worth of plasma data obtained by the UCSD electrostatic electrometer on board ATS 5. The result is primarily intended for use as a general reference for engineers designing a large spacecraft to be flown at GSO. A simple mathematical formula using a 3rd order polynomial is found to be adequate for representing the yearly averaged particle energy spectrum from 70 to 41,000 eV under different geomagnetic conditions. Furthermore, correlation analyses with the geomagnetic planetary index Kp and with the auroral electrojet index AE were carried out in the hope that the ground observations of the geomagnetic field variations can be used to predict the plasma variations in space. Unfortunately, the results indicate that such forecasting is not feasible by use of these two popular geomagnetic parameters alone.

Su, S. Y.↗

Retarding potential analyzer for the Pioneer-Venus Orbiter Mission

The retarding potential analyzer on the Pioneer-Venus Orbiter Mission has been designed to measure most of the thermal plasma parameters within and near the Venusian ionosphere. Parameters include total ion concentration, concentrations of the more abundant ions, ion temperatures, ion drift velocity, electron temperature, and low-energy (0-50 eV) electron distribution function. To accomplish these measurements on a spinning vehicle with a small telemetry bit rate, several functions, including decision functions not previously used in RPA's, have been developed and incorporated into this instrument. The more significant functions include automatic electrometer ranging with background current compensation; digital, quadratic retarding potential step generation for the ion and low-energy electron scans; a current sampling interval of 2 ms throughout all scans; digital logic inflection point detection and data selection; and automatic ram direction detection. Extensive numerical simulation and plasma chamber tests have been conducted to verify adequacy of the design for the Pioneer Mission.

Knudsen, W. C.↗