Estimating the Electric Fields Driving Lightning Dart Leader Development With BIMAP‐3D Observations

Abstract In this paper, a numerical dart leader model has been implemented to understand the leader's development and the corresponding electric field changes observed by the 3D broadband mapping and polarization (BIMAP‐3D) system. The model assumes the extending leader channel is equipotential and has a linear charge distribution induced by an ambient electric field. The charge distribution induced by the ambient field can be used to model the electric field change at the ground. We then find the ambient electric field which best fits the field change measurements at the two BIMAP stations. The estimated ambient electric field decreases in the direction of dart leader propagation. Our observations and modeling results are consistent with our earlier hypothesis that dart leader speed is proportional to the electric field at the leader tip. The model also supports our earlier analysis that leader speed variations near branch junctions were due to previous charge deposits near the junctions. The modeled tip electric field is generally lower than the breakdown field unless the pre‐dart‐leader channel has a significant temperature of 3,000 K. This is consistent with the fact that dart leaders typically do not form new branches into the virgin air. Furthermore, the tip field is generally close to the negative streamer stability field at ambient temperatures, explaining the nature of the narrow and well‐defined channel structure. In addition to the charge distribution and the ambient and tip electric field, the development of the channel potential and current distribution are also presented.

3D lightning mapping↗

Spokane Eco-District Campus Performance Under Alternative Electricity Rates: Benefits for virtual power plant participants and suppliers

Here, the respective benefits for virtual power plant participants and suppliers are revealed and compared under alternative electricity rate structures, including conventional large commercial electricity rates, large commercial electricity rates with special rates for demand-side generation, and dynamic hourly transactive prices. These three scenarios were explored using the capabilities of the Eco-District campus, a virtual power plant in Spokane, Washington, that is supplied electricity by Avista Utilities. The Eco-District Campus was modeled to host solar power generation, battery energy storage, and thermal energy resources that must be coordinated with building heating and cooling needs. First, the electricity supplier’s costs for energy, infrastructure, and energy losses were modeled. Then, the virtual power plant’s performance was modeled while presuming that its manager would minimize its costs under its electricity rate structure. The demand charges of conventional commercial electricity rates managed monthly peak, as would be expected, but hourly dynamic transactive pricing resulted in a striking alignment between the costs incurred by the supplier and the virtual power plant’s energy costs.

Electricity rates↗

County Electric Vehicle Home Charging Access Shares from the 2030 National Charging Network Study

This file contains modeled county-level home electric vehicle (EV) charging access shares from the study, "The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure" by Wood et al. (2023). These are based on modeling in "There's No Place Like Home: Residential Parking, Electrical Access, and Implications for the Future of Electric Vehicle Charging Infrastructure" by Ge et al. (2021). Wood, Eric, et al. 2023. The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure. Golden, CO: National Renewable Energy Laboratory. NREP/TP-5400-85654. https://www.nlr.gov/docs/fy23osti/85654.pdf . Ge, Yanbo, et al. 2021. There's No Place Like Home: Residential Parking, Electrical Access, and Implications for the Future of Electric Vehicle Charging Infrastructure. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-81065. https://www.nlr.gov/docs/fy22osti/81065.pdf .

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cross-sectoral synergies for household energy savings: the role of electric vehicles, solar photovoltaics, and remote work

Over the past two decades, new technologies and behavioral shifts – such as electric vehicles, solar photovoltaics, and increased work-from-home practices – have reshaped residential electricity consumption and cost. However, their combined or synergistic impact on a household’s electricity cost remains unexplored. Leveraging data from the 2020 Residential Energy Consumption Survey, this study uses a structural equation model to unravel the extent to which the bundled adoption of EV-PV and stay-at-home decisions impact the total electricity cost of households. Results indicate that adopting both EVs and PV reduces electricity costs by 31% despite a 16% rise in consumption. When combined with stay-at-home practices, households still experience a 13% cost reduction, even with a 25% increase in electricity consumption. In conclusion, these findings suggest that financial savings are not merely a byproduct of adopting new technologies or behavioral changes but could serve as a key consideration for household contemplating engagement with multiple modern energy solutions simultaneously.

14 SOLAR ENERGY↗

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

Retail Electricity Price and Cost Trends: 2024 Update [Slides]

Berkeley Lab’s "Retail Electricity Price and Cost Trends" summarizes recent trends in retail electricity price levels and price drivers in the United States. This report is intended to serve as a reference document for the diverse set of decision-makers impacted by changes in retail electricity prices and to provide a factual basis for assessing recent changes in retail electricity prices and key underlying drivers. National, regional, and state trends are reported for 2019 through 2023 using publicly-available data for: -Average retail electricity prices, retail sales, and utility revenues -Utility capital expenditures, operations and maintenance costs, and fuel and purchased power costs -Retail electricity sales impacts from behind-the-meter resources The report also includes qualitative case studies highlighting recent and/or regionally-specific issues contributing significantly to retail electricity price trends

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities

Electricity demand from large load customers such as data centers is projected to grow significantly in the near term. While data centers play an important role in advancing technology innovation and economic growth in the United States, data center energy needs present challenges and opportunities for electricity supply and infrastructure. This technical brief serves as a foundation for the discussion of issues and sharing of perspectives among utilities, regulators, large load customers, and other stakeholders. As utilities and regulators explore rate structures to address growing data center electricity demand, several issues have emerged: -Fair allocation of electricity system costs to large-load customers without unfair shifting of costs to other customers -Appropriate mitigation of the financial risks associated with stranded assets from underutilized utility system investments -Mitigation of operational and resource adequacy risks if electricity demand exceeds supply -Appropriate risk-sharing in commercializing newer electricity technologies such as advanced geothermal, small modular reactors, and long duration energy storage -Accommodating the diverse needs of large-load customers, such as having the option to match electricity consumption with output from carbon-free resources or using onsite generation to provide system capacity The technical brief also identifies key design elements that aim to address these issues and uses leading examples from pending and approved rate structures, agreements, and special contracts to ground the elements in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Year Electric Field Study at the North Slope of Alaska (OYESNSA) Field Campaign Report

The Global Electric Circuit (GEC) of the atmosphere provides a unique perspective on Earth’s changing climate. Monitoring this global electrical signature provides details of the global nature of electrified clouds and thunderstorms. The North Slope of Alaska (NSA) is a unique location for collecting these electric field measurements. Besides being at the opposite pole from many previous electric field measurements taken at Russia’s Vostok station in Antarctica, this site provides a rare opportunity to use other instruments at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s NSA observatory at Utqiaġvik (formerly known as Barrow), such as the Ka-band ARM Zenith Radar (KAZR), upward-facing micropulse lidar (MPL), vertical profile of meteorological measures, and other aerosol measurements. Since 2017, Texas A&M University at Corpus Christi (TAMUCC) has established an observational instrument package, including CS110 electric fields and anemometer, at ARM’s NSA observatory at Utqiaġvik. This enabled the unique opportunity to not only provide information about the global signature of the GEC, but also the physical inputs to the local electric field, by analyzing the physical properties of the simultaneous cloud, wind, and aerosol properties occurring with the vertical electric field.

54 ENVIRONMENTAL SCIENCES↗

Multi-Year Electric Field Study at the North Slope of Alaska (OYESNSA) Field Campaign Report

The Global Electric Circuit (GEC) of the atmosphere provides a unique perspective on Earth’s changing climate. Monitoring this global electrical signature provides details of the global nature of electrified clouds and thunderstorms. The North Slope of Alaska (NSA) is a unique location for collecting these electric field measurements. Besides being at the opposite pole from many previous electric field measurements taken at Russia’s Vostok station in Antarctica, this site provides a rare opportunity to use other instruments at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s NSA observatory at Utqiaġvik (formerly known as Barrow), such as the Ka-band ARM Zenith Radar (KAZR), upward-facing micropulse lidar (MPL), vertical profile of meteorological measures, and other aerosol measurements. Since 2017, Texas A&M University at Corpus Christi (TAMUCC) has established an observational instrument package, including CS110 electric fields and anemometer, at ARM’s NSA observatory at Utqiaġvik. This enabled the unique opportunity to not only provide information about the global signature of the GEC, but also the physical inputs to the local electric field, by analyzing the physical properties of the simultaneous cloud, wind, and aerosol properties occurring with the vertical electric field.

54 ENVIRONMENTAL SCIENCES↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Fleet-Level Fuel Impact of Hybrid-Electric Aircraft in United States

Here, this paper examines the impact of two potential solutions for increasing fuel efficiency and reducing emissions in commercial aviation: hybrid-electric propulsion and the use of drop-in synthetic aviation fuels (SAFs). The authors modeled three representative aircraft employed in the U.S. domestic market: a 70-seat regional turboprop, a 100-seat airliner, and a 180-seat airliner. These aircraft were retrofitted with hybrid-electric propulsion systems that integrate batteries and electric motors to provide additional torque to the propeller or fan. The authors explored various technological scenarios involving different battery specific energies, electric motor specific powers, and other relevant parameters. Flight performance models were used to analyze the range–payload capabilities of these new hybrid-electric aircraft and to compare them with their conventional counterparts. Subsequently, the authors virtually deployed the hybrid-electric aircraft on 2019 U.S. domestic commercial flights to assess the types and lengths of flights that could be serviced by this new fleet. We then compared the resulting fuel consumption, energy use, and emissions with those of a conventional fleet using a combination of jet fuel and SAF.

SAF↗

Hourly Electricity Demand Profiles for Each County in the Contiguous United States

This dataset provides estimated hourly electricity demand for each county in the contiguous United States from 2016-2023. The demand profiles represent the sum of two components: (1) Weighted averages of reported hourly demand profiles for North American Electric Reliability Corporation balancing authority (BA) regions and subregions, scaled to match annual estimates of county-level retail sales and direct use of electricity and weighted by the estimated percentage of county load served by each BA region or subregion. (2) Weighted averages of modeled hourly, county- and sector-level distributed photovoltaic (DPV) capacity factor profiles, scaled to match annual estimates of on-site consumption of DPV-generated electricity for each county and weighted by the percentage of consumption attributable to each sector Annual county-level retail sales are estimated by aggregating utility-reported sales to the state level and allocating the results to counties according to each county's share of state population. Annual county-level direct use is calculated by aggregating power plant-reported direct use values. Annual county-level on-site consumption of DPV-generated electricity is estimated by aggregating utility-reported net metering data to determine the amount of DPV-generated electricity sold back to the grid for each state, subtracting those values from modeled state-level DPV generation estimates, and allocating the results to counties according to each county's share of statewide modeled DPV generation. The open-source Python code used to develop this dataset is available at "Historical Load Data Repository" link below.

14 SOLAR ENERGY↗

Theoretical model of dielectrophoretic water vapor condensation during multiphase flow of electrically charged water droplets in air

Water droplet growth in air, influenced by vapor diffusion and electrical charging, has significant implications for indoor air quality, cloud formation, and aerosol dynamics. Here, this study presents a comprehensive theoretical model that describes the growth dynamics of electrically charged water droplets under external electric fields, incorporating diffusion, electrostatic, and dielectrophoretic forces to enhance understanding and practical applications in air dehumidification and environmental control. A theoretical model was established to analyze the growth dynamics of the charged water droplets. The approach extended the thermodynamic framework of the Modified Kelvin-Thomson equation by integrating electrostatic and dielectrophoretic effects, enabling a comprehensive evaluation of vapor concentration near the surface of charged droplets. A sensitivity analysis was performed to assess the roles of droplet size, electric field intensity, surface charge, and vapor concentration on condensation rates. The study progressed beyond the classical diffusion-limited growth of neutral droplets, addressing the behavior of charged droplets in electrohydrodynamic environments. The model highlighted the significance of dielectrophoretic drift flux for dipolar vapor molecules, especially in micron-sized droplets ranging from 10 to 100 µm. Findings demonstrated that, for smaller droplets subjected to elevated electrical charge, average growth rates varied from 0.3 to 1.6 µm/s if the air relative humidity increased from 50 to 100 %. Analytical results are corroborated by numerical simulations, which exhibited strong concordance, thereby validating the proposed theoretical approach. This research introduced an innovative and scalable analytical methodology for electric field-enhanced droplet growth, offering valuable insights into the advancement of energy-efficient air dehumidification, water desalination, and atmospheric water harvesting technologies.

42 ENGINEERING↗

Analytic Nuclear Gradients Including Oriented External Electric Fields in a Molecule-Fixed Frame

Electric-field-assisted chemistry has attracted much attention in recent years, particularly in the context of oriented external electric fields for controlling molecular structure and reactivity. Such fields have been explored in a wide range of applications, including switching materials, nanoparticles, controllable catalysts, medicines, and clinical therapies. However, the determination of fixed fields in the laboratory frame becomes ineffective for flexible molecules, as conformational changes can significantly alter the relative orientation between the applied field and molecular structure. In this work, we propose two molecular reference frames─the principal axis frame and the local reference frame─to define oriented electric fields within the molecular framework. These coordinate systems powerfully eliminate ambiguities in the relative orientation between the applied field and the molecule. Analytic nuclear gradients in the presence of external electric fields are derived and implemented, with an initial application to field-dependent geometry optimizations of cis - and trans -formanilide. Analysis of the resulting field-induced equilibrium structures reveals distinct structural responses, validating the accuracy and robustness of the proposed formalism. The analytic gradient framework enables systematic investigations of molecular properties and reactivity under arbitrarily oriented electric fields, opening new opportunities for computational modeling and rational design in electric-field-controlled chemistry.

electric fields↗

Real-World Cyber Security Demonstration for Networked Electric Drives

In this article, we present the design and implementation of a cyber-physical security testbed for networked electric drive systems, aimed at conducting real-world security demonstrations. To our knowledge, this is one of the first security testbeds for networked electric drives, seamlessly integrating the domains of power electronics and computer science, and cybersecurity. By doing so, the testbed offers a comprehensive platform to explore and understand the intricate and often complex interactions between cyber and physical systems. The core of our testbed consists of four electric machine drives, meticulously configured to emulate small-scale but realistic information technology (IT) and operational technology (OT) networks. This setup both provides a controlled environment for simulating a wide array of cyber-attacks, and mirrors potential real-world attack scenarios with a high degree of fidelity. The testbed serves as an invaluable resource for the study of cyber-physical security, offering a practical and dynamic platform for testing and validating cybersecurity measures in the context of networked electric drive systems. As a concrete example of the testbed's capabilities, we have developed and implemented a Python-based script designed to execute step-stone attacks over a wireless local area network (WLAN). This script leverages a sequence of target IP addresses, simulating a real-world attack vector that could be exploited by adversaries. To counteract such threats, we demonstrate the efficacy of our developed cyber-attack detection algorithms, which are integral to our testbed's security framework. Furthermore, the testbed incorporates a real-time visualization system using InfluxDB and Grafana, providing a dynamic and interactive representation of networked electric drives and their associated security monitoring mechanisms. This visualization component not only enhances the testbed's usability but also offers insightful, real-time data for researchers and practitioners, thereby facilitating a deeper understanding of cyber-physical security dynamics in networked electric drive systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric Vehicle Supply Equipment (EVSE) Site Assessment Report for the U.S. Army Corps of Engineers Chena Site Near Fairbanks, Alaska

This report presents an analysis of the requirements for charging station installation and electric vehicle operation at the US Army Corps of Engineers - Chena Site, located in a cold weather climate in the Fairbanks North Star Borough, AK. The report includes findings from a site visit, and a detailed electric vehicle (EV) charging site plan with cost estimates. Cost for three 50-ampere pedestal chargers located on the edge of the existing parking lot is estimated at $\$$53,100, and the cost of three 80-ampere chargers is estimated at $\$$89,400. The authors did not assess the cost of a heated garage. The USACE Chena site reaches extreme cold temperatures of -40 Degrees Celsius (-40 Degrees Fahrenheit) and below in a typical winter, often for days on end. Considerations of operating EVs as well as electrical vehicle supply equipment (EVSE) at this site can be applicable to other cold or extremely cold locations. Interviews with EV users in cold climates and a literature review indicated that EVs operate well but have significantly decreased range compared to 21 Degrees Celsius (70 Degrees Fahrenheit) operations. Some strategies such as prewarming the vehicle while it is plugged in and using heated seats and steering wheel instead of cabin heat, can improve cold weather performance. Storing the EV in a garage would mean the battery and cabin are automatically preheated, the battery would not age as rapidly as when the vehicle is stored outside, and problems with charging the vehicle are less likely. Lowest temperate-rated Electric Vehicle Supply Equipment (EVSE), as electric vehicle chargers are known as, are rated to -40 Degrees Celsius (-40 Degrees Fahrenheit), and sometimes malfunction. No EVSE is rated to the temperatures that USACE Chena site experienced for more than a week in winter 2023-4, of -50 Degrees Celsius (-45 Degrees Fahrenheit) and which are typical for the area. If reliability is a must, entities may want to consider a heated garage to minimize potential problems with charging equipment. There is a companion technical report to this titled "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska" that examines the data on EV and EVSE cold-weather functionality in more detail. (Esparza, Truffer Moudra, and Hodge 2024).

33 ADVANCED PROPULSION SYSTEMS↗

An Additively Manufactured Fe-3Si Stator for a High-Performance Electrical Motor

Additive manufacturing (AM) has the potential to produce novel high-performance electrical machines, enabling the direct printing of complex shapes and the simultaneous processing of multiple feedstocks in a single build. We examined the properties and functional performance of Fe-3 wt.% Si materials that were printed via selective laser melting, machined down to thin laminates, and stacked to form a stator core of a prototype brushless permanent-magnet electrical motor. Big Area Additive Manufacturing of Nd2Fe14B (NdFeB)–polyphenylene sulfide (PPS) bonded magnets was performed, with them then being magnetized and used for the rotor. The magnetic, mechanical, and electrical properties of the as-printed and various heat-treated thin laminates and the back electromotive force (EMF) of the electrical motors at different rotational speeds were measured. The thin laminates exhibit a maximum relative permeability of 7494 at an applied field of 0.8 Oe and a core loss of about 20 W/lb at 60 Hz with the maximum induction of 15 kg. In addition to the demonstration of AM printing, motor assembly, and complete characterization of printed Fe-3 wt.% Si, this report highlights the areas of improvement needed in printing technologies to achieve AM built electrical motors and the need for isotropic microstructure refinements to make the laminates appropriate for high-mechanical-strength and low-loss rotational electrical devices.

36 MATERIALS SCIENCE↗

Local Electric Field Effects on Water Dissociation in Bipolar Membranes Studied Using Core–Shell Catalysts

The local electric field strength is thought to affect the rate of water dissociation (WD) in bipolar membranes (BPMs) at the catalyst–nanoparticle surfaces. Here, we study core–shell nanoparticles, where the core is metallic, semiconducting, or insulating, to understand this effect. The nanoparticle cores were coated with a WD catalyst layer (TiO2 or HfO2) via atomic layer deposition (ALD), and the morphology was imaged with transmission electron microscopy. Irrespective of the core material, these core–shell catalysts displayed comparable WD overpotentials at optimal mass loading, despite the hypothesized differences in the electric field strength across the catalyst particle suggested by continuum electrostatic simulations. Substantial atomic interdiffusion between the core and shell was ruled out by X-ray absorption spectroscopy, X-ray photoelectron spectroscopy, and diffuse reflectance optical measurements. However, the optimal mass loading of catalyst was roughly 1 order of magnitude higher for the conductive and high dielectric core materials than for the low dielectric insulating cores. These findings are consistent with the hypothesis that electric field screening within the core material focuses the electric field drop between particles such that larger film thicknesses can be tolerated. Collectively, these data support the idea that it is the local electric field at the molecular level that controls proton-transfer rates and that the metal core/dielectric-shell constructs introduced here modulate that field. Further materials and synthetic design may enable optimization of the electric field strength across the proton-transfer trajectory at the material surface.

Sarma, Prasad V↗