Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cost Efficient and Highly Weather-Resistant Solar Panel Backsheet Produced through Continuous Co-Extrusion Processing

The efficient generation and delivery of ‘clean energy” through photovoltaic (PV) technology relies heavily on the cost, performance and reliability of solar panels, along with the individual components used in assembly of those panels. In order to continue towards the Department of Energy’s (DOE) goals of driving costs down, the lifetime of high-output power generation equipment (i.e. solar modules) must be extended to reduce costs associated with power output degradation and replacement of failed or degraded panels. One of the major sources of module failures in the past 30 years has been the failure of the solar panel backsheet. Failure of this component causes severe output losses due to oxidation and yellowing of the module while creating safety concerns as the major electrical insulation of the module is compromised. Tomark-Worthen LLC was formed in 2012 with the goal of designing and manufacturing novel PV backsheets and encapsulants that would be produced in the United States of America and exceed expectations of domestic and international module producers. These backsheets would improve upon known backsheet design failures (i.e. Isovoltaic’s AAA backsheet) and create domestic manufacturing jobs in the PV sector. This goal became a reality with a first-generation product in 2018 and now, with the support of the DOE, Tomark-Worthen has launched a second-generation product known as PhotoMark® Reflections™ 205-3 and 360-3. This 2+ year effort began in late 2017 with a screening of potential polymeric materials and backsheet structural designs. Performance evaluations of each material provided the necessary data needed to select the proper material combinations and move forward into the design of the manufacturing process. These decisions were made by teaming with a local university, well-respected government laboratories, and private research organizations who provided the tools necessary to predict long-term performance of these materials in much shorter periods of time. Once the go/no-go criteria were met at the mid-point of the project, the effort transitioned to predicting 30+ year performance, achieving certifications, and improving manufacturing efficiencies designed to lower costs in order to be competitive in a cost-driven market. Major project accomplishments include recognition of the new backsheet by Underwriters Laboratories (UL) and international certification for 1000V and 1500V modules by TUV Sud. Both 1000V and 1500V products have been proven on several module manufacturing lines and initial customer orders have been received by both domestic and international module producers. Accelerated exposure testing has shown that the performance of this backsheet exceeds the prior polyamide-based backsheet known to fail in the field. Cost-models and initial customer orders have shown the ability to produce this backsheet at a cost acceptable to many domestic manufacturers, while International costs for standard backsheet remains extremely low. Tomark-Worthen remains one of the only U.S. companies manufacturing backsheet domestically and this has drawn interest from many domestic module manufacturers looking to improve their material supply logistics by avoiding long lead times and custom’s headaches while avoiding current tariffs on Chinese-made components. Along with the launch of a new PV backsheet, this project has provided a critical deliverable to the PV R&D community. This deliverable is the knowledge that not all polyamide-containing backsheets are doomed to failure as the earlier versions did. There has been a fear amongst the PV community to consider these materials due to the failure of one design. This effort has brought a new level of interest to the scientific community as it has been shown that polyamides can be used successfully in a well-designed backsheet. As we move forward from this project, we are excited to see how backsheet technology and manufacturing in the U.S. will continue to progress and grow.

14 SOLAR ENERGY↗

Benchtop-Scale High Temperature Molten Salt Electrochemical Reactors: Experimental Setup and Considerations

Molten salt electrochemical reduction (MSER) is the dominant production method for aluminum and titanium, and emerging technologies for producing other commodity metals with these highly electrified techniques have demonstrated promising results. However, the scale up of MSER of materials such as iron and silicon are limited by the challenging issues of materials compatibility and impurity control. This work describes an experimental MSER setup using both chloride and carbonate salts. This setup is designed for operations outside of a glovebox, which is practical from an industrial perspective, but creates unique challenges. This work serves as a practical guide to discuss some key operational difficulties such as temperature control, air and humidity, material compatibility, developing strong electrical measurements and techniques, and safety.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Transmission-Distribution Multi-Period Switching for Wildfire Risk Mitigation: Improving Speed and Scalability with Distributed Optimization: Preprint

With increasingly severe wildfire conditions driven by climate change, utilities must manage the risk of wildfire ignitions from electric power lines. During "public safety power shutoff'" events, utilities de-energize power lines to reduce wildfire ignition risk, which may result in load shedding. Distributed energy resources provide flexibility that can help support the system to reduce load shedding when lines are de-energized. We investigate a coordinated transmission-distribution optimization problem that balances wildfire risk mitigation and load shedding. We model distribution systems that include battery energy storage systems which may support loads when transmission lines are de-energized. This multi-period integrated transmission-distribution optimal switching problem jointly optimizes line switching decisions, the generators' setpoints, load shedding, and the batteries' states of charge, resulting in significant computational challenges. To improve scalability, we decompose the problem over both space and time and apply a distributed optimization algorithm. Using a large-scale synthetic California test case with realistic distribution models and real wildfire risk data, we show that distributed optimization can solve large-scale multi-period switching problems that are otherwise intractable for centralized solvers. We also discuss challenges and future directions for improving the distributed algorithm's convergence performance as the number of time periods increases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feasibility and Qualitative Risk Assessment of Fuel Cell Electric Bus Use for Emergency Backup Power for Airport Applications

Airports rely on robust backup power systems to maintain critical operations during emergencies. This paper investigates the feasibility of using hydrogen fuel cell electric buses (FCEBs) as emergency backup power sources, focusing on their technical specifications, operational challenges, and associated risks. Using Portland International Airport as a case study, the analysis evaluates the power output and hydrogen consumption of New Flyer’s 40’ Xcelsior Charge fuel cell buses, to provide power for key airport systems. Additionally, the paper explores the design and layout of how FCEBs can be connected to airport facilities, and addresses safety considerations, hydrogen supply logistics, and electrical compatibility. While FCEBs present significant advantages in terms of sustainability and resilience, their implementation requires careful planning, infrastructure investment, and adherence to safety standards. This research provides actionable insights for airport stakeholders seeking to transition to hydrogen-based backup power system.

08 HYDROGEN↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hazard and Operability Analysis for Operating, Refueling, and Maintenance of Fuel Cell Electric Buses

​​Since hydrogen vehicles can be implemented in heavy-duty transportation applications such as buses, it is important to understand safety hazards and risks of hydrogen fuel cell electric bus (FCEB) and refueling technology. We conducted a hazard and operability analysis for FCEB operation/driving, refueling, and maintenance/inspection. We identified failure modes and consequences and defined a qualitative risk metric as the product of the likelihood of a failure and the severity of the worst-ca

08 HYDROGEN↗

Development and Validation of a Simulation Tool to Predict the Combined Structural, Electrical, Electrochemical and Thermal Responses of Automotive Batteries

Battery safety is one of the most important design factors of electrified vehicles (EVs) since battery failure may lead to a catastrophic consequence. To improve the safety of battery systems in EVs, battery behaviors under various abuse conditions should be well understood. One way to examine battery response under extreme conditions is to conduct abuse tests in different scenarios. They can provide first-hand pass/fail information on battery safety, but they are usually expensive and time-consuming, which is inconvenient during design iterations and optimization. On the other hand, computational modeling can predict the battery behaviors in a more efficient and cost-effective way, which becomes an important tool to evaluate battery safety. Modeling battery responses and failure is challenging since it involves multiple coupled physical processes, needs to consider complex material properties and is computationally intensive. This project aims to develop a practical simulation tool to predict the combined structural, electrical, electrochemical, and thermal responses of automotive batteries to crash-induced crush and short circuit and validate it for conditions relevant to automotive crash. Advanced material constitutive models will be utilized to capture the mechanical response of cell components. Moreover, methods will be developed to reduce computational complexity of the model and allow battery safety simulations to extend from cell-level to module/pack level with affordable computational resources.

25 ENERGY STORAGE↗

Perspective—On the Safety of Aged Lithium-Ion Batteries

Concerns about the safety of lithium-ion batteries have motivated numerous studies on the response of fresh cells to abusive, off-nominal conditions, but studies on aged cells are relatively rare. This perspective considers all open literature on the thermal, electrical, and mechanical abuse response of aged lithium-ion cells and modules to identify critical changes in their behavior relative to fresh cells. We outline data gaps in aged cell safety, including electrical and mechanical testing, and module-level experiments. Understanding how the abuse response of aged cells differs from fresh cells will enable the design of more effective energy storage failure mitigation systems.

25 ENERGY STORAGE↗

Alternative Ratemaking in the US: A Prerequisite for Grid Modernization or an Unwarranted Shift of Risk to Customers?

With increasing frequency, investor-owned electric utilities are requesting preferred cost recovery for "grid modernization" in multiple forms, from multi-year rate plans to riders. Utilities' claims that massive grid investment is necessary, and that exceptional investment requires exceptional cost recovery, are typically accepted by policymakers with little challenge. It is difficult for policymakers to resist the siren call of grid modernization's perceived outcomes, from improved reliability and resilience to reduced risks to safety and new customer technology adoption (electric vehicles, distributed energy resources, and more). This paper provides a contrarian viewpoint that is virtually absent as policymakers consider alternative ratemaking practices. It introduces the possibility that excess grid investment in the name of modernization is not only possible, and economically harmful, but has already occurred, encouraged by alternative ratemaking. It provides examples of common grid modernization expenditures the authors have identified as cost-ineffective in the course of their work. It also describes traditional grid planning practices with proven ability to address changing requirements over time, calling into question the need for exceptional grid modernization investment plans. Most important, the paper explains the moral hazard inherent in alternative ratemaking, and the fundamental shift in ratemaking risks and responsibilities from utilities to customers that results. The perspectives this paper presents are critical for policymakers to understand before adopting, extending, or expanding alternative ratemaking practices in their respective jurisdictions.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Counter Data Paucity through Adversarial Invariance Encoding: A Case Study on Modeling Battery Thermal Runaway

Lithium-ion batteries, widely used for their durability and high energy storage, face the risk of internal short circuits leading to catastrophic thermal runaway events. These events, triggered by external stimuli like mechanical loads, pose safety concerns in applications such as electric vehicles. Detecting and understanding thermal runaway events is crucial, but physics-driven models struggle to explain the non-linear evolution of battery temperature during these events, considering factors like material composition and state-of-charge. Due to the rarity of these events and the cost of data collection, we propose a deep learning (DL) model to predict battery temperature responses during thermal runaway. The challenge lies in the scarcity of data, making traditional DL models prone to overfitting and learning low-quality representations of the complex process.Our approach introduces a novel few-shot architecture that incorporates an adversarially governed invariant encoding process. This architecture aims to distill "invariant" relationships by addressing distributional shifts in data across various battery properties, facilitating the detection of thermal runaway events. Specifically, our results demonstrate that deep learning models conditioned on these "invariant" representations outperform state-of-the-art baselines, achieving a remarkable 96.8% performance improvement in terms of the popular metric MAPE. This framework presents a promising direction for enhancing battery safety modeling, particularly in the context of rare and complex events like thermal runaway. Our code and code and dataset used for the paper are public1.

Tabassum, Anika [ORNL] (ORCID:0000000254600955)↗

Core inductive electric field during sawtooth crashes on DIII-D

Sawtooth crashes on tokamak plasmas exhibit relaxation much faster than resistive time scales via a mechanism not fully understood. Using core magnetic measurements from the Radial Interferometer-Polarimeter (RIP) diagnostic on the DIII-D tokamak, Grad–Shafranov equilibria constrained by internal magnetic measurements that have high time resolution (<1μs) can be computed, allowing analysis of how equilibrium parameters such as safety factor q, current density J, and parallel electric field E ∥ , particularly on-axis, evolve. At the sawtooth crash, on-axis safety factor q 0 is observed to rise by 5% but remain below 1 throughout the cycle, and on-axis current density J 0 is observed to drop by 5%. On-axis parallel electric field E ∥ (0) is found to be balanced by ηJ 0 (resistivity times on-axis current density) except during the 200 µs crash period, where E ∥ (0) reaches 22 V m –1 , exceeding ηJ 0 by a factor of more than 2000. These first measurements in tokamak plasmas verify that generalized Ohm's law is not balanced during the crash by resistive effects alone; this is a finding expected due to the relaxation being much faster than resistive timescales. As a result, measurement of the electric field during the tokamak sawtooth serves to illuminate the physical mechanisms at work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN↗

Enabling Structure/Interface Regulation for High Performance Ni-Rich Cathodes

Here, further commercialization of Ni-rich layered cathodes is hindered by severe structure/interface degradation and kinetic hindrance that occur during electrochemical operation, which leads to safety risks and reduced range in electric vehicles (EVs). Herein, by selecting elements with different solubility properties, a multifunctional strategy that synchronously fabricates perovskite-type SrZrO 3 coating and Sr/Zr co-doping is employed to strengthen the structure/interface stability and the Li + transport mobility of LiNi 0.85 Co 0.10 Mn 0.05 O 2 (NCM). Perovskite-type SrZrO 3 protective layers formed on the particle surface can substantially mitigate the unexpected interfacial side reactions and surface phase transitions. In addition, a robust crystal framework is constructed by optimizing local O coordination through the introduction of strong Zr-O bonds. Notably, Li + diffusion kinetics is effectively improved due to expanded cell parameters and O-Li-O slab spacing with the incorporation of large-diameter Sr pillar ions, as revealed by X-ray diffraction. As a result, the Sr/Zr-modified NCM achieves a remarkable capacity retention of 99.4% after 200 cycles at 1 C, and a high rate capacity of 168.9 mAh g -1 at 10 C. This work opens new avenues to develop high-performance NCM cathodes with high energy and high power for EVs with long calendar life.

25 ENERGY STORAGE↗

Assessment of Thermal Stratification in Versatile Test Reactor Transients

The Versatile Test Reactor (VTR) is a fast-spectrum test reactor currently being developed in the United States under the direction of the US Department of Energy. The conceptual design of the 300 MWth pool-type sodium-cooled fast reactor (SFR) has been led by the US National Laboratories in collaboration with General Electric-Hitachi and Bechtel National Inc. Safety performance analysis for the VTR conceptual design is being performed with the systems thermal-hydraulics (SYSTH) module of the SAS4A/SASSYS-1 liquid-metal reactor safety analysis code system. Since the current model of the VTR employs a simple perfect mixing model for large plena like the hot pool, it is not able to predict temperature variations that may develop during the transient. Prior work simulating the response of SFRs to postulated events like the Protected Station Blackout (PSBO) has shown that the phenomenon of thermal stratification, where stable thermal layers accumulate in the hot pool, may delay the transition to natural circulation and thus impact the predicted transient progression. Thus, an effort has begun to model this transient by integrating a Computational Fluid Dynamics (CFD) model of the hot pool into the SAS4A/SASSYS-1 model of the Primary Heat Transport System during the simulation of the PSBO event. A three-dimensional Volume-Of-Fluid CFD model of the VTR hot pool has been developed for the co-simulation of SAS4A/SASSYS-1 with CFD. In this work, the standalone SAS4A/SASSYS-1 calculation and the standalone CFD calculation based on the SAS4A/SASSYS-1 calculation result were produced on the Idaho National Laboratory High Performance Computing cluster, SAWTOOTH. At this time, only the standalone CFD and SAS4A/SASYS-1 simulation results are provided.

99 GENERAL AND MISCELLANEOUS↗

Recommended Actions to Improve Adapter Safety

With the rapid advancement and acceleration in the electric vehicle (EV) industry within the United States, major automakers and EV charging companies are increasingly adopting the North American Charging Standard (NACS) connector style, now officially known as J3400. This shift is expected to enhance charging infrastructure, providing a better customer experience by making it easier for all EV drivers to access a wider network of direct-current (DC) fast chargers (DCFCs). However, the adoption of the J3400 standard presents challenges for many EVs already on the roads and some currently coming off production lines that are equipped with the Combined Charging System (CCS) connector, which this report will refer to as the North American standard, CCS1. These vehicles will need adapters to use new or existing J3400 infrastructure. During this transition, several issues have emerged. Firstly, there is a need to standardize the new connector type to ensure it is interoperable, safe, and reliable. Second, existing CCS EV drivers need a way to access the J3400 network, which will require electric vehicle supply equipment (EVSE) or sites with both connector types, driver-provided adapters to physically convert from CCS to J3400, or EVSE with retained adapters designed for use with the EVSE. Third, adapter standards will need to be written to specify how they will be designed and what evaluations will be needed to ensure safe and reliable performance. To address these challenges, adapters that support different types of charging connectors will be essential. These adapters will play a crucial role in supporting the transition and ensuring continued service for legacy EVs with CCS inlets as the J3400 standard becomes the predominant one in the United States. Consequently, the National Charging Experience (ChargeX) Consortium has investigated and performed a teardown analysis on the different adapter versions on the market. The aim is to create a failure mode and effects analysis (FMEA) on what are expected to be the most common adapter types used in this transition. In order to support this work, we executed an FMEA exercise with the main goal of identifying gaps in the existing adapters' performance and conformance to the most common safety requirements of high-power and high-voltage devices. This effort focused on adapters provided by the driver, as these may present the highest safety and reliability risks. The recommendations made here apply to both retained and driver-provided adapters.

25 ENERGY STORAGE↗

Smart dim fuse: electrical load flexibility controller using sub-circuit voltage modulation and load sensing

Improved control of electrical power consumption is provided with “Smart Dim Fuses” (SDF) which can alter their output voltage as provided to the load circuits they are connected to. SDF units can replace conventional circuit breakers in electrical panels. The voltage control capability provided by SDF units can lead to improved control of electrical power consumption, since many loads can smoothly operate at lower power consumption when the voltage they are driven with decreases. SDF units can comply with relevant safety requirements, such as uninterrupted neutral connections between electrical mains and load circuits. SDF units can also provide a current limiting function that can substitute for the protective action of conventional circuit breakers.

Goldin, Aaron↗

Inverters: A Pivotal Role in PV Generated Electricity

This presentation discusses the pivotal role inverters play in PV generated electricity. Topics include: the inverter as the center of the system--increasingly becoming the brain, with more features and capabilities (hybrid systems, safety, islanding, monitoring, etc.); increasing inverter-based generated electricity associated with many renewable energy sources; increased dependence for grid support and forming capability; communication within the grid and security increasingly required; increasing complexity leads to more chances to fail; as in most PV segments, there is cost reduction pressure, which makes it more challenging to keep the reliability high.

ENGINEERING,SOLAR ENERGY↗