A structural and thermal packaging approach for power processing units for 30-cm ion thrusters

Solar Electric Propulsion (SEP) is currently being studied for possible use in a number of near earth and planetary missions. The thruster subsystem for these missions would consist of 30 centimeter ion thrusters with Power Processor Units (PPU) clustered in assemblies of from two to ten units. A preliminary design study of the electronic packaging of the PPU has been completed at Lewis Research Center of NASA. This study evaluates designs meeting the competing requirements of low system weight and overall mission flexibility. These requirements are evaluated regarding structural and thermal design, electrical efficiency, and integration of the electrical circuits into a functional PPU layout.

Maloy, J. E.↗

A structural and thermal packaging approach for power processing units for 30-cm ion thrusters

Solar Electric Propulsion (SEP) is currently being studied for possible use in a number of near earth and planetary missions. The thruster subsystem for these missions would consist of 30 centimeter ion thrusters with Power Processor Units (PPU) clustered in assemblies of from two to ten units. A preliminary design study of the electronic packaging of the PPU has been completed at Lewis Research Center of NASA. This study evaluates designs meeting the competing requirements of low system weight and overall mission flexibility. These requirements are evaluated regarding structural and thermal design, electrical efficiency, and integration of the electrical circuits into a functional PPU layout.

Maloy, J. E.↗

Preliminary Design of Low-Thrust Interplanetary Missions

For interplanetary missions, highly efficient electric propulsion systems can be used to increase the mass delivered to the destination and/or reduce the trip time over typical chemical propulsion systems. This technology is being demonstrated on the Deep Space 1 mission - part of NASA's New Millennium Program validating technologies which can lower the cost and risk and enhance the performance of future missions. With the successful demonstration on Deep Space 1, future missions can consider electric propulsion as a viable propulsion option. Electric propulsion systems, while highly efficient, produce only a small amount of thrust. As a result, the engines operate during a significant fraction of the trajectory. This characteristic makes it much more difficult to find optimal trajectories. The methods for optimizing low-thrust trajectories are typically categorized as either indirect, or direct. Indirect methods are based on calculus of variations, resulting in a two-point boundary value problem that is solved by satisfying terminal constraints and targeting conditions. These methods are subject to extreme sensitivity to the initial guess of the variables - some of which are not physically intuitive. Adding a gravity assist to the trajectory compounds the sensitivity. Direct methods parameterize the problem and use nonlinear programming techniques to optimize an objective function by adjusting a set of variables. A variety of methods of this type have been examined with varying results. These methods are subject to the limitations of the nonlinear programming techniques. In this paper we present a direct method intended to be used primarily for preliminary design of low-thrust interplanetary trajectories, including those with multiple gravity assists. Preliminary design implies a willingness to accept limited accuracy to achieve an efficient algorithm that executes quickly.

Sims, Jon A.↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

Solar Electric Propulsion for Mars Exploration

Highly propellant-efficient electric propulsion is being combined with advanced solar power technology to provide a non-nuclear transportation option for the human exploration of Mars. By virtue of its high specific impulse, electric propulsion offers a greater change in spacecraft velocity for each pound of propellant than do conventional chemical rockets. As a result, a mission to Mars based on solar electric propulsion (SEP) would require fewer heavy-lift launches than a traditional all-chemical space propulsion scenario would. Performance, as measured by mass to orbit and trip time, would be comparable to the NASA design reference mission for human Mars exploration, which utilizes nuclear thermal propulsion; but it would avoid the issues surrounding the use of nuclear reactors in space.

Hack, Kurt J.↗

NASA GRC Stirling Research Lab

The efficiency of conversion from thermal to electrical can be increased significantly by using the Stirling thermodynamic cycle •Alternate heating and cooling on volume of gas creates a pressure wave that drives a piston attached to an alternator •Heat can be supplied by any source –radioisotope •Cooling must also be provided for the waste heat portion of the cycle –radiant heat transfer to space •Up to 40% thermal-to-electric efficiency •Dynamic : has moving parts Cycle operation: •A displacer shuttles gas between the hot and cold ends to raise and lower the gas pressure •With displacer at the top, gas is pushed towards cold end, lowering the pressure •With displacer at the bottom, gas is pushed towards the hot-end, raising the pressure •The piston’s mechanical energy can then be utilized as desired –for electrical power it is coupled to an alternator •The motions of the piston and displacer can be controlled by mechanical linkages (kinematic) or by the working gas pressure (free piston)

Stirling Research Lab↗

One joule output from a diode-array-pumped Nd:YAG laser with side-pumped rod geometry

Output of 1.25 J per pulse (1.064 micron) with an absolute optical efficiency of 28 percent and corresponding electrical efficiency of 10 percent was demonstrated in a diode-array-pumped Nd:YAG laser using a side-pumped rod geometry in a master-oscillator/power-amplifier configuration. In Q-switched operation, an output of 0.75 J in a 17-ns pulse was obtained. The fundamental laser output was frequency doubled in KTP with 60 percent conversion efficiency to obtain 0.45 J in a 16-ns pulse at 532 nm. The output beam had high spatial quality with pointing stability better than 40 microrad and a shot-to-shot pulse energy fluctuation of less than +/-3 percent.

Kasinski, Jeffrey J.↗

High Performance Green LEDs for Solid State Lighting

The development of white LEDs for solid state lighting (SSL) has been driven in recent years by phosphor converted LEDs (pc-LEDs). However, losses (known as Stokes’ losses) between the blue pump LED and phosphor impose a fundamental efficiency limit of ~300 lm/W on pc-LEDs. White light can also be generated from color mixed LEDs (cm-LEDs), which employ red, green, blue, and amber LEDs and have a fundamental efficiency limit of ~400 lm/W. Efficient group III-nitride materials are used for the blue LED, while efficient group III-phosphide materials are used for the red LED component. Currently, the poor efficiency of green and amber LEDs (i.e. the “green gap”) is the primary limitation for cm-LEDs. Relative to nitride-based blue LEDs, green and amber nitride LEDs suffer from lower radiative recombination rates and higher nonradiative recombination rates, which ultimately lead to reduced internal quantum efficiency (IQE). The IQE represents the portion of all electron-hole recombination events that result in a photon. In addition, long-wavelength LEDs have lower electrical efficiency (EE) compared to their blue counterparts. Addressing the green gap, would ultimately enable cm-LEDs that rival or exceed the performance of pc-LEDs. Our project focused on III-nitride materials growth and characterization, device fabrication and testing, and semiconductor physics to understand efficiency limitations of green LEDs and develop solutions to these challenges. Insights gained during our research has led to novel long-wavelength LED designs which will enable efficient solid-state lighting.

30 DIRECT ENERGY CONVERSION↗

Carbonate Management to Enable Energy- and Carbon-Efficient CO 2 Electrolysis (Final Technical Report)

The rapid growth and plummeting cost of solar energy have spurred growing interest in using CO 2 electrolysis to produce chemicals and fuels as an alternative to conventional petrochemical processes. High-temperature (>800 °C) solid oxide electrolyzers that convert CO 2 into CO and O 2 have recently become commercially available. Low-temperature electrolysis cells offer the prospect of more convenient and flexible operation, which is critical for utilizing intermittent solar energy, and provide access to more valuable C 2+ products such as ethylene, ethanol, and propanol. Over the past 10 years, research in this area has yielded substantial progress in both fundamental understanding of the requisite electrocatalytic reactions and design of prototype devices. Leveraging insights from fuel cells and membrane water electrolyzers, researchers have developed electrolysis cells with gas diffusion electrodes (GDE) that have demonstrated high CO 2 electrolysis current densities (>100 mA cm –2 ) as well as promising selectivity and stability. Despite these advances, the energy efficiency (electrical energy-to-product) and carbon efficiency (CO 2 -to-product) of low-temperature CO 2 electrolysis remain far too low for large-scale deployment. A preponderance of evidence indicates that the principal source of efficiency losses is the rapid and thermodynamically favorable reaction of CO 2 with hydroxide (OH – ) to form carbonate (CO 3 2– ). Carbonate formation imposes steady-state electrolysis conditions that result in large voltage and CO 2 losses for all known (photo)electrochemical CO 2 cells. While much current research remains focused on CO 2 reduction catalyst design, this largely overlooked CO 3 2– problem presents a fundamental scientific barrier to creating a viable electrochemical option for converting solar energy into chemicals and fuels. The project pursues an integrated, multi-PI research effort that establishes a fundamental science of CO 3 2– management. PI Kanan and Co-PI Mani’s contribution to the project is to evaluate strategies to mitigate the CO 3 2– problem by changing the properties of the electrolyte and the environment in which CO 2 reduction catalysis takes place. Experimental studies showed that electrolytes composed of a high concentration of both CO 3 2– and HCO 3 – , which serve as moderately alkaline buffers, improved the cell voltage by compared to all-HCO 3 – electrolytes, but these buffered systems still show substantial CO 2 uptake that reduces pH over time. Computational studies developed a homogenized model of a CO 2 reduction catalyst layer that permits a low-cost exploration of the high-dimensional parameter space associated with catalyst layers on gas diffusion electrodes. The model was validated by accurately reproducing experimental data for the related but simpler reaction of CO reduction and then used to probe the effects of catalyst layer architecture on CO 2 reduction. Minimizing the size of catalyst and hydrophobic domains in the catalyst layer is predicted to mitigate CO 3 2– formation and thereby enable prolonged operation at elevated pH. In support of the CO 2 electrolysis studies, a new method for rapidly prototyping electrochemical cells was developed and validated. The method uses a combination of 3D printing and electroless plating to generate conductive cell components for evaluating new cell designs. The carbonate problem encompasses mass transport processes and acid-base reactions that are relevant to many other electrochemical systems. Investigation of strategies to address the carbonate problem led to an additional line of inquiry into the physicochemical phenomena that determine the efficiency of electrochemical acid-base production, which has numerous applications in the broader field of carbon management. New strategies for using the supporting electrolyte to inhibit H + /OH – recombination in electrochemical acid-base production were evaluated, leading to the development of a novel acid-base producing system that eliminates the need for ion exchange membranes and exhibits promising efficiency and current densities for scalable applications.

25 ENERGY STORAGE↗

Carbonate Management to Enable Energy- and Carbon-Efficient CO 2 Electrolysis (Final Technical Report)

The rapid growth and plummeting cost of solar energy have created great interest in using CO 2 electrolysis to produce chemical feedstocks and fuels such as carbon monoxide, ethylene, ethanol, and propanol. While research in CO 2 electrolysis has yielded substantial progress in both fundamental understanding of the requisite electrocatalytic reactions and design of prototype devices, the energy efficiency (electrical energy to-product) and carbon efficiency (CO 2 -to-product) of CO 2 electrolysis remain far too low for large-scale deployment. A preponderance of evidence indicates that the principal reason for these low efficiencies is the rapid and thermodynamically favorable reaction of CO 2 with hydroxide (OH–) to form carbonate , which forces CO 2 electrolysis cells to operate under conditions that result in large voltage and CO 2 losses. This “CO 3 2 – problem” presents a fundamental scientific barrier to creating a viable electrochemical option for converting solar energy into chemicals and fuels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and Analysis of a Thermophotovoltaic Integrated Self-Powered Furnace

This work investigates the energy efficiency and carbon reduction potential of self-powered residential building heating equipment using a thermodynamic modeling approach. An integrated thermophotovoltaic power module and residential scale furnace system (40,000 Btu/h) were modeled and studied in detail to assess the influence of different design configurations on primary energy efficiency. Operational characteristics such as total power generation, electrical efficiency, and heat recovery were examined in a self-powered system configuration. A sensitivity analysis was conducted to determine the influence of the electric grid’s carbon dioxide footprint (carbon intensity) and the cost of electricity on the environmental, as well as the economic, benefit associated with the self-powered configuration. Compared with a traditional furnace powered by an electric grid at a carbon intensity of 0.5 kg CO 2eq /kWh EL , the self-powered furnace was shown to decrease the annual carbon dioxide emissions by approximately 550 kg (~75% reduction), while also saving more than USD 200 in utility expenses, annually. Additionally, the carbon emission reduction potential of blending different concentrations of hydrogen in natural gas fuel was also studied.

14 SOLAR ENERGY↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High current, high bandwidth laser diode current driver

A laser diode current driver has been developed for free space laser communications. The driver provides 300 mA peak modulation current and exhibits an optical risetime of less than 400 ps. The current and optical pulses are well behaved and show minimal ringing. The driver is well suited for QPPM modulation at data rates up to 440 Mbit/s. Much previous work has championed current steering circuits; in contrast, the present driver is a single-ended on/off switch. This results in twice the power efficiency as a current steering driver. The driver electrical efficiency for QPPM data is 34 percent. The high speed switch is realized with a Ku-band GaAsFET transistor, with a suitable pre-drive circuit, on a hybrid microcircuit adjacent to the laser diode.

Copeland, David J.↗

Computational Analysis of the X-57 Maxwell Airplane at Unpowered Conditions (Preliminary Fuselage)

The X-57 Maxwell is an all-electric airplane that implements a distributed electric propulsion system to demonstrate that high-efficiency electric propulsion can be integrated with aerodynamics to increase the performance of an airplane. To this end, distributed electric fans were installed on the wing to provide increased flow over the wing at the low takeoff and landing speeds of the X-57. The low-speed lift augmentation allows for a reduction in wing area for cruise optimization. The X-57 wing area was reduced to 42 percent of the wing area of the baseline aircraft, a Tecnam P2006T. With this reduced wing area and the electric propulsion system, it is estimated that the X-57 will cruise on less than one-third the total energy compared to the baseline aircraft. To meet the cruise performance goal at a Mach number of 0.233 at an altitude of 8000 feet, the X-57 has a cruise lift coefficient of 0.7516 and needs to have a cruise drag coefficient of 0.05423 or less. The USM3D computational solver was used to investigate the X-57 performance, without the distributed electric propulsion high-lift system operating. The unpowered X-57 performance is of interest to quantify if the X-57 can meet the cruise drag performance goal, and to document the lift performance of the very small wing at takeoff and landing conditions. The primary configurations investigated in this paper include the cruise configuration with no flap deflection, a takeoff configuration with a 10◦ flap deflection, and a landing configuration with a 30◦ flap deflection. The conditions for the cruise configuration were a flight unit Reynolds number of 1.32E+06 per foot, an altitude of 8000 feet, a Mach number of 0.233, and angles of attack from −2° to 24° . At the cruise lift coefficient of 0.7516, the computed drag coefficient is 0.05275. This computed drag is less than the drag coefficient of 0.05423 that is required to meet the X-57 airplane performance goal. However, the computational airplane is a completely smooth geometry and does not account for protuberance drag, nor the drag from steps and gaps in the actual X-57 airplane. Therefore, based upon the CFD drag calculation there is a 10-percent margin to account for some of the differences between the as-built metal fuselage and empennage construction, and the smooth computational geometry. The computed cruise drag also does not account for an induced drag reduction due to the wing-tip propellers and a drag reduction due to laminar flow achieved on the wing. The computed lift to drag ratio is 14.14 at the cruise lift coefficient of 0.7516, and the maximum computed lift to drag ratio is 15.8. The maximum lift coefficient for the cruise configuration was 2.13 at an angle of attack of 15°. The conditions for the takeoff configuration with a 10° flap deflection were a flight unit Reynolds number of 0.986E+06 per foot, an altitude of 2500 feet, a Mach number of 0.149, and angles of attack from −2° to 22°. The maximum lift coefficient for the takeoff configuration was 2.21 at an angle of attack of 16°. The conditions for the landing configuration with a 30° flap deflection were a flight unit Reynolds number of 0.922E+06 per foot, an altitude of 2500 feet, a Mach number of 0.139, and angles of attack from −2° to 24°. The maximum lift coefficient for the landing configuration was 2.58 and occurred at two angles of attack, 10° and 14°. Based on the unpowered maximum lift coefficient of 2.58 for the 30° flap deflection, along with computations of the distributed electric propulsion lift augmentation (not shown in this paper), the X-57 Maxwell is estimated to meet its powered landing goal of a maximum lift coefficient of 4.0.

X-57 Maxwell Airplane↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

The water use of data center workloads: A review and assessment of key determinants

The global importance of data center water use is increasing with the rapid growth of digitalization and artificial intelligence. This study analyzes the factors influencing workload-level water use, measured in liters consumed per workload, to guide water-saving strategies in data centers. Our findings reveal workload-level water use variations exceeding 10,000-fold, driven by over 1000-fold differences in water consumption per kilowatt hour of server electricity consumed and approximately 10-fold differences in server workload efficiency. Key determinants are ranked as server efficiency, electrical grid water consumption factors, server utilization, cooling system type, infrastructure efficiency, climate zone, inactive server percentage, and server refresh cycle. Notably, there is no single recipe for minimizing water use; instead, optimal outcomes depend on tailored combinations of these factors. This analysis addresses critical knowledge gaps by identifying the determinants of data center water use and exploring their achievable minima under diverse site-specific constraints.

Data centers↗

NASA's X-57 High Lift Motor Controller: Detailed Design, Test Results, and Outcomes

NASA's X-57 all-electric aircraft was a research project aimed at investigating lightweight and efficient electric propulsion components. The general approach was to utilize a distributed electric propulsion (DEP) design. An essential component of this design was the High Lift Motor Controller (HLMC), a motor drive which provided power to the High Lift Motors (HLMs) and High Lift Propellers (HLPs) responsible for providing additional thrust for take-off and landing. This paper presents the detailed design, test results, and outcomes from the development of the HLMC, a 14 kW, 1kg, 98.3% efficient, outer mold line (OML) cooled, silicon carbide (SiC) MOSFET-based inverter and controller.

Electric Aircraft↗

Partially Turboelectric Aircraft Drive Key Performance Parameters

The purpose of this paper is to propose electric drive specific power, electric drive efficiency, and electrical propulsion fraction as the key performance parameters for a partially turboelectric aircraft power system and to investigate their impact on the overall aircraft performance. Breguet range equations for a base conventional turbofan aircraft and a partially turboelectric aircraft are found. The benefits and costs that may result from the partially turboelectric system are enumerated. A break even analysis is conducted to find the minimum allowable electric drive specific power and efficiency, for a given electrical propulsion fraction, that can preserve the range, fuel weight, operating empty weight, and payload weight of the conventional aircraft. Current and future power system performance is compared to the required performance to determine the potential benefit.