Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical cables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of Copper Catalytic Effects in Cable Insulation Polymers

This paper summarizes work performed to evaluate a phenomenon that occurs in electrical cable insulation polymers subjected to accelerated aging while in contact with copper metal. This effect, commonly known as the copper catalytic effect, is a result of chemical reactions that occur when copper ions diffuse into insulation polymers. This diffusion process is observed in various types of polymeric materials exposed to elevated temperatures and happens at the interface between the insulation and metallic components (e.g., conductor, shielding, etc.) in a cable. This polymer-metal interaction has only been observed in cables constructed with copper components (i.e., no interactions observed in cables with aluminum or other metal conductor/shielding) and results in a significant catalytic effect that increases the oxidation rate (e.g., aging) of the material. Under this research, the copper catalytic effects observed in cross-linked polyethylene, cross-linked polyolefin and ethylene propylene rubber insulated cables subjected to thermal accelerated aging were evaluated. These evaluations involved applying infrared spectroscopy, microscopy, and energy dispersive X-ray spectroscopy cross-sectional depth profiling to obtain an in-depth understanding of the aging characteristics of the materials under accelerated conditions. Based on the results of these assessments, the copper catalytic effect can have a significant impact on the mechanical, thermal, chemical, and electrical properties of cable insulation polymers. Here, the results acquired from this research provided the information needed to characterize the copper catalytic effects observed in these polymers, analyze how this phenomenon affected the polymer degradation process, and compare and understand the differences in the properties of the materials.

42 ENGINEERING↗

Non-Intrusive Impedance-Based Cable Tester

A non-intrusive electrical cable tester determines the nature and location of a discontinuity in a cable through application of an oscillating signal to one end of the cable. The frequency of the oscillating signal is varied in increments until a minimum, close to zero voltage is measured at a signal injection point which is indicative of a minimum impedance at that point. The frequency of the test signal at which the minimum impedance occurs is then employed to determine the distance to the discontinuity by employing a formula which relates this distance to the signal frequency and the velocity factor of the cable. A numerically controlled oscillator is provided to generate the oscillating signal, and a microcontroller automatically controls operation of the cable tester to make the desired measurements and display the results. The device is contained in a portable housing which may be hand held to facilitate convenient use of the device in difficult to access locations.

Medelius, Pedro J.↗

Consideration of Decabromodiphenyl Ether Flame Retardant in Thermal and Radiation Aging of Crosslinked Polyethylene Cable Insulation

Decabromodiphenyl ether (decaBDE) has been used as a flame-retardant additive in nuclear-grade electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. On January 6, 2021, the Environmental Protection Agency (EPA) published a final rule to phase out decaBDE. The 2021 rule set a two-year compliance deadline for “processing and distribution in commerce of decaBDE for use in wire and cable insulation in nuclear power generation facilities.” In recognition of industry concerns following a sudden discontinuation of decaBDE-containing Class 1E wire and cable essential for nuclear power operations and the time needed for qualifying the individual components using the alternative insulation technology, an extended compliance deadline was set in the finalized amendments to the 2021 rule as published by the Environmental Appeals Board on November 12, 2024. The 2024 rule set the compliance deadline for processing and distributing decaBDE-containing wire and cable insulation until the end of the service life of these materials. Since decaBDE has long been relied upon as the flame retardant in one of the most common cross-linked polyethylene (XLPE) nuclear cable insulation formulations, RSCC Firewall III insulation, questions have naturally arisen regarding whether changes in cable performance might be expected for XLPE containing a decaBDE alternative, especially for safety-related cables that must perform their safety function in a design basis event such as a loss of coolant accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detection of diffusion limited oxidation in thermally aged ethylene propylene rubber cable insulation material

The lifetime prediction of electrical cable insulation in nuclear power plants (NPPs) is primarily based on accelerated aging. Polymeric insulation exposed to accelerated aging at high temperatures may demonstrate diffusion limited oxidation (DLO) where oxygen within the material is consumed faster than can be supplied by diffusion from the surrounding air. This situation leads to equilibrium oxidation at the exposed surfaces and limited oxidation away from the surfaces. Therefore, DLO results in a heterogeneously aged material which can lead to underestimation of lifetime for in-service cable insulation. In this study, the presence of inhomogeneous aging caused by DLO was evaluated on cross-sectioned cable insulation specimens made of ethylene propylene rubber (EPR). The studies were performed on thermally aged specimens (165 °C, 1 day and 165 °C, 16 days) using local measurement techniques including nanoindentation, micro-Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM) - energy dispersive spectroscopy (EDS). All the results indicate some degree of heterogenous aging, with 165 °C, 16 days, aging demonstrating highest degree of oxidative degradation on the inside edges presumably caused due to copper catalyzed oxidation.

Pallaka, Madhusudhan Reddy↗

Cables and connectors: A compilation

A technological compilation on devices and techniques for various types of electrical cables and connections is presented. Data are reported under three sections: flat conductor cable technology, newly developed electrical connectors, and miscellaneous articles and information on cables and connector techniques.

Source record↗

Application of Cable Condition Monitoring Technologies to Assess Age-Related Degradation of Industrial Cables Installed in Harsh Environments

The aging of electrical cables has been the subject of substantial research and development (R&D) projects performed by national and international laboratories, universities, and private organizations for many years. This R&D was conducted to develop guidance, equipment, and techniques to support aging management of in-service cables in industrial facilities such as nuclear power plants, research reactors, waste facilities, and fuel fabrication plants. Through these research efforts, condition monitoring technologies have been developed that can determine the severity of age-related degradation that occurs in industrial cables and insulation polymers during service. This paper summarizes the results of aging assessments that were performed for cables installed in two U.S. nuclear power plants, one a pressurized water reactor and one a boiling water reactor. These cables had been in service for over 40 years and during plant operation were exposed to harsh environmental conditions including elevated temperatures and radiation. For these assessments, a comprehensive series of measurements was performed to assess the aged condition of the cables. These cables came from different manufacturers, were manufactured in different years, and were constructed with a variety of jacket and insulation polymers including chloro-sulfonated polyethylene (CSPE), cross-linked polyethylene (XLPE)/cross-linked polyolefin (XLPO), neoprene, and ethylene propylene rubber (EPR). The goal of these assessments was to determine the current aged condition of the cable polymers and provide an estimate of how long the cable insulation materials could remain exposed to their in-service environmental conditions before reaching their end-of-life condition. Both nuclear power plants have received license renewals to extend their operation from 40 to 60 years, and the utilities need objective evidence to show that critical components such as cables will be able to function safely and reliably during the extended operating period. Furthermore, the results of these assessments showed that the cables exhibited different aged conditions depending on the type of polymers they were constructed with and the environment they were exposed to during service. Some of the cables and insulation polymers showed signs of significant age-related degradation and were estimated to have approximately 5 years of remaining service life. Other cables exhibited no signs of significant age-related degradation and were estimated to have 50 years or more of remaining service life. Using the results of these cable aging assessments, plant personnel were able to (1) determine the overall aged condition of cables and insulation polymers using objective test results, (2) identify aged or degraded cables before they caused operability issues, and (3) avoid unnecessary and costly replacement of cables that can continue to operate safely and reliably.

36 MATERIALS SCIENCE↗

Cable manufacture

A survey is presented of flat electrical cable manufacturing, with particular reference to patented processes. The economics of manufacture based on an analysis of material and operating costs is considered for the various methods. Attention is given to the competitive advantages of the several processes and their resulting products. The historical area of flat cable manufacture is presented to give a frame of reference for the survey.

Gamble, P.↗

Handtool assists in bundling cables

Simple tool makes it possible to bundle electrical cables in channel or "tray" without requiring cables be lifted out. Procedure for bundling is faster and less awkward than lifting method. Used with commercially-available plastic ribbons that tie cables together, tool guides ribbon along tray wall, through bracket at bottom of tray, and up opposite wall. One end of ribbon locks in other end, securing cable bundle.

Stringer, E. J.↗

A polytetrafluorethylene insulated cable for high temperature oxygen aerospace applications

For electrical cables to function and survive in the severe high temperature oxygen environment that will be experienced in the external tanks of the space shuttle, extreme cleanliness and material purity is required. A flexible light weight cable has been developed for use in pure oxygen at worst case temperatures of -190 to +260 degrees Centigrade and pressures as high as 44 pounds per square inch absolute. A comprehensive series of tests were performed on cables manufactured to the best commercial practices in order to establish the basic guidelines for control of build configuration as well as each material used in construction of the cable.

Sheppard, A. T.↗

Sequential versus Simultaneous Aging of EPDM Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables are integral to power, control, and instrumentation systems within nuclear power plants (NPPs). Exposure of cable systems within nuclear containment to elevated temperatures and gamma radiation during decades-long operation of NPPs can lead to degradation of cable polymeric insulation. Prediction of nuclear cable insulation degradation is complicated as thermal and radiation stress are not additive. In this work, we explore the relative effects of simultaneous and sequential thermal and gamma irradiation on the aging of ethylene-propylene-diene (EPDM) elastomer insulation to better understand realistic scenarios of cable insulation degradation. Cable insulation samples of EPDM were subjected to up to 320 kGy of gamma radiation at a dose rate of 300 Gy/hr in two heating scenarios: (1) simultaneously aged samples were heated at 150°C during irradiation and (2) sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation at ambient temperature. The mass, tensile elongation at break, and carbonyl index were assessed to quantify aging of the polymers. The simultaneous aging scenario was found to the more severe of the two for EPDM insulation degradation.

ethylene-propylene-diene elastomer, EPDM, nuclear ↗

Universal Cable Brackets

Concept allows routing easily changed. No custom hardware required in concept. Instead, standard brackets cut to length and installed at selected locations along cable route. If cable route is changed, brackets simply moved to new locations. Concept for "universal" cable brackets make it easy to route electrical cable around and through virtually any structure.

Vanvalkenburgh, C.↗

Downlink Data Multiplexer

A multiplexer/demultiplexer system has been developed to enable the transmission, over a single channel, of four data streams generated by a variety of sources at different (including variable) bit rates. In the original intended application, replicas of this multiplexer/demultiplexer system would be incorporated into the spacecraft-to-ground communication systems of the space shuttles. The multiplexer of each system would be installed in the spacecraft, where it would acquire and process data from such sources as commercial digital camcorders, video tape recorders, and the spacecraft telemetry system. The demultiplexer of each system would be installed in a ground station. Purely terrestrial systems of similar design could be attractive for use in situations in which there are requirements to transmit multiple streams of high-quality video data and possibly other data over single channels. The figure is a block diagram of the multiplexer as configured to process data received via three fiber-optic channels like those of the International Space Station and one electrical-cable channel that conforms to the Institute of Electrical and Electronic Engineers (IEEE) 1394 standard. (This standard consists of specifications of a high-speed serial data interface, the physical layer of which includes a cable known in the art as "FireWire." An IEEE 1394 interface can also transfer power between the components to which it is connected.) The fiber-optic channels carry packet and/or bit-stream signals that conform to the standards of the Consultative Committee for Space Data Systems (CCSDS). The IEEE 1394 interface accepts an isochronous signal like that from a digital camcorder or a video tape recorder. The processing of the four input data streams to combine them into one output stream is governed by a statistical multiplexing algorithm that features a flow-control capability and makes it possible to utilize the transmission channel with nearly 100-percent efficiency. This algorithm allocates the available bandwidth of the transmission channel to the data streams according to a combination of data rates and preassigned priorities. Incoming data streams that demand too much bandwidth are blocked. Bandwidth not needed for a transmission of a given data stream is allocated to other streams as available. Priority is given to the IEEE 1394 stream. In addition to the four incoming data streams, the multiplexer transmits data on the status of the system. An operator can monitor and control the multiplexer via displays and controls on the multiplexer housing. The output of the multiplexer is connected via a coaxial cable with an impedance of 50 Ohms to an interface circuit compatible with the space-shuttle high-speed digital downlink, which operates at a rate of 48 Mb/s.

Holland, Douglas↗

The ARENA Test Bed – A Versatile Resource for I&C Development and Validation

The Accelerated and Real-time Experimental Nodal Assessment (ARENA) Test Bed at the Pacific Northwest National Laboratory (PNNL) is a versatile resource for development and validation of instrumentation and control (I&C) technologies. This capability was created to facilitate in-situ testing of nuclear electrical cables in various simulated operational environments. Using cable trays, a control box, and selected test components, low voltage cables can be staged to experience local adverse environments such as elevated temperature and water immersion. Cable condition can be continuously monitored over time to track the effect of local stresses using nondestructive assessment tools. A heads-up display (ARENA TV) plots key data in real-time for users. The ARENA Test Bed has recently been used to evaluate the potential for spread spectrum time domain reflectometry (SSTDR) to monitor thermal aging of a portion of live cable powering a three-phase motor. The arrangement provided the opportunity to directly compare the performance of the novel online SSTDR method with offline results from the more standard frequency domain reflectometry (FDR) method. The ability of SSTDR and FDR to identify the presence of water in immersed shielded and unshielded cables and to detect ground faults was also assessed. A digital twin is being developed to track and predict FDR signals from a thermally aging conceptual cable region to compare with measured signals from the ARENA physical counterpart. The test bed concept addresses an important need in nuclear I&C monitoring tool development. New tools and techniques can be developed in the test bed and validated versus known methods and physical measurements. Digital twins and machine learning engines can be populated with measured data in a controlled environment that would not be readily available in the actual nuclear power plant. Proposed monitoring strategies can be confirmed for effectiveness through objective evaluation. It is anticipated that the PNNL ARENA Test Bed will be a valuable resource in advancing nuclear plant instrumentation.

nuclear electrical cables, ARENA Test Bed, conditi↗

Program for Space Shuttle Payload Cabling

EXCABL is expert-system computer program developed to route electrical cables in Space Shuttle Orbiter payload bay for each mission. Automates cable-routing process and provides data for cable-installation documents. Automation increased speed and accuracy of payload-integration process, and expert system codifies knowledge cabling experts have acquired. Written in ART.

Schultz, Roger D.↗

Leading/lagging cable referencing platform for monitoring the health of underground cable networks

A system for detecting water trees in branching underground electrical cables includes a pulse generator configured to inject a pulse into a first underground cable that branches into a second underground cable and a third underground cable. The system includes a first sensor associated with the first cable, a second sensor associated with the second cable, and a third sensor associated with the third cable. The system includes a control device configured to obtain a first, second, and third signal associated with the first, second and third sensors, respectively. The control device determines a lead-lag relationship between the second and third signals and determines presence of a water tree within at least one of the second and third cable based on the lead-lag relationship. When presence of a water tree is determined, the control device generates a control action associated with repairing or replacing the second and/or third cable.

Burkes, Klaehn W.↗

Cable clamp bolt fixture facilitates assembly in close quarters

Cable clamp bolt holding fixture facilitates forming of electrical cable runs in limited equipment space. The fixture engages the threads of the short clamp bolt through the clamp and maintains tension against clamp tendency to open while the operator installs the nut without difficulty.

Sunderland, G. H.↗

Thermal and Electrical Conductivity Measurements of CDA 510 Phosphor Bronze

Many cryogenic systems use electrical cables containing phosphor bronze wire. While phosphor bronze's electrical and thermal conductivity values have been published, there is significant variation among different phosphor bronze formulations. The James Webb Space Telescope (JWST) will use several phosphor bronze wire harnesses containing a specific formulation (CDA 510, annealed temper). The heat conducted into the JWST instrument stage is dominated by these harnesses, and approximately half of the harness conductance is due to the phosphor bronze wires. Since the JWST radiators are expected to just keep the instruments at their operating temperature with limited cooling margin, it is important to know the thermal conductivity of the actual alloy being used. We describe an experiment which measured the electrical and thermal conductivity of this material between 4 and 295 Kelvin.

Tuttle, James E.↗