Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables: Preprint

This paper performs a transient stability study of a real-world microgrid with 100% renewables to fully understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, the full-scale electromagnetic transient modeling of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid, which gives good references for the field deployment in terms of inverter configuration and coordination as well as the capabilities of black start and unplanned islanding.

100% renewable microgrid↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

PV-Fed Smart Inverters for Mitigation of Voltage and Frequency Fluctuations in Islanded Microgrids

The presence of low-inertia distributed generation (DG) units makes islanded microgrids vulnerable to voltage and frequency variations. Besides, the considerable difference between the inertia of synchronous-based and inverter-based DGs results in a power imbalance between supply and demand during abnormal conditions. As a result, both voltage and frequency of microgrid ac-bus start oscillating which might have severe consequences such as blackouts. This paper deploys the traditional controller of photovoltaic (PV) units to improve the dynamic behavior of islanded microgrids by suppressing the voltage and frequency fluctuations. To this end, an adaptive piecewise droop (APD) characteristic is proposed and employed in PV units to attain a faster balance between generation and consumption during transients, leading to an enhanced frequency response. Besides, the reactive-power control loop is equipped with a droop characteristic which enables the PV units to inject/absorb reactive power during transients and participate in voltage-profile enhancement of the system. Case study results are presented using PSCAD/EMTDC to confirm the validity of proposed method in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗

Disturbance Propagation Stability in Droop-Controlled Microgrids

The disturbance response of the angle dynamics for a droop-controlled islanded microgrid is characterized. Specifically, a notion of propagation stability is defined, which is concerned with spatial attenuation vs amplification of input- output responses in the network in a H8 or H2 sense. Criteria for propagation stability are developed, phrased in terms of the microgrid’s inverter control parameters. The input frequency range over which the network is susceptible to amplification is also characterized, in the case that the criteria are not met. Based on the formal analysis, a the design of resilient controls that trade off coherence and disturbance propagation goals is briefly conceptualized. Finally, the propagation stability analysis is illustrate using a 15-bus example microgrid network.

Roy, Sandip↗

Using Distributed Dynamic Voltage Restorers to Improve the Frequency Stability of Low-Inertia Networked Microgrids

This paper elucidates the novel concept of using distributed dynamic voltage restorers (DVRs), which are traditionally used to compensate for voltage sags, to improve the frequency stability of low-inertia networked microgrids. During frequency transients, the distributed DVRs rapidly regulate load voltages within an acceptable range, resulting in a fast change of load power consumption and helping improve frequency stability. To enable large-scale network simulation, a phasor-based model of DVRs is developed and validated against real data from a commercially available device. Finally, simulation results of a modified IEEE 123-node test feeder that comprises three microgrids and six DVRs verify the effectiveness of the proposed method.

Du, Wei↗

Ensemble voting-based fault classification and location identification for a distribution system with microgrids using smart meter measurements

This study presents an ensemble learning approach for fault classification and location identification in a smart distribution network containing photovoltaics (PV)-based microgrid. Lack of available data points and the unbalanced nature of the distribution system make fault handling a challenging task for utilities. The proposed method uses event-driven voltage data from smart meters to classify and locate faults. The ensemble voting classifier is composed of three base learners; random forest, k-nearest neighbours, and artificial neural network. The fault location (FL) task has been formulated as a classification problem where the fault type is classified in the first step and based on the fault type, the faulty bus is identified. The method is tested on IEEE-123 bus system modified with added PV-based microgrid along with dynamic loading conditions and varying fault resistances from 0 to 20 Ω for both unbalanced and balanced fault types. A further sensitivity analysis has been done to test the robustness of the proposed method under various noise levels and data loss errors in the smart meter measurements. The ensemble method shows improved performance and robustness compared to some previously proposed FL methods. Finally, the proposed method has been experimentally validated on a real-time simulation-based testbed using a state-of-the-art digital real-time simulator, industry standard DNP3 communication protocol and a cpu-based control centre running the FL algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Modeling of Sequential Service Restoration in Islanded Single Master Microgrids

This paper presents a methodology for generating restoration sequences in distribution systems and microgrids with emphasis on deriving optimal switching times for remote control switches (RCS). Microgrid architecture considered are assumed to be operating in islanded single master mode. Control methods for handling the unbalance inherent in distribution systems using single-phase controlled PQ inverters were developed and incorporated in the proposed method. The problem of considering simultaneously both energy optimization and dynamic stability of the system, which is lacking in existing methods, was addressed by studying the transient behavior of microgrids based on extended EMTP simulations and then approximate and incorporate these behaviors into the optimization formulation for restoration. The approach is based on multi-objective optimization of final restored load and total restoration time. The methodology was studied on a modified IEEE 123 node test feeder. An EMTP simulation in PSCAD of the formed microgrids was used to validate the accuracy of the dynamic and steady-state characteristics of the resulting systems. By considering the transient behavior of DGs during restoration, a better restoration sequence that does not trigger protection relays could be realized.

42 ENGINEERING↗

Networked Microgrid Topology Reconfiguration to Promote Fairness in Proactive Load Shedding

Increasing occurrences of natural disasters and grid emergency events consistently challenge the safe and reliable operations of power systems. During such emergency situations, system operators may proactively shed load to mitigate risks. However, uncoordinated implementation of load shedding may disrupt electricity supply and even lead to cascading failures. Meanwhile, it is crucial to address potential biases affecting different customers when executing load shedding. This paper addresses the dynamic topology reconfiguration problem for networked microgrids with distributed energy resources under emergency conditions. Specifically, we propose a novel rolling-horizon optimization model that integrates fairness-aware constraints into the networked microgrid topology reconfiguration. Unlike existing approaches that focus solely on efficiency or apply fairness considerations in static settings, our method explicitly incorporates temporal fairness constraints to restrict repeated or excessive load curtailment for load blocks. Moreover, the fairness-aware constraints are specifically developed for the context of dynamic networked microgrid topology reconfiguration, and are designed to be convex or amenable to linear reformulations, which offers a more tractable alternative to traditional models with non-convex formulations. Numerical studies on a modified IEEE 13-bus system and a larger-sized SMART-DS networked microgrid system demonstrate the performance of the proposed algorithm towards more fairness-aware networked microgrid topology reconfiguration decision-making.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ensuring Transient Stability With Guaranteed Region of Attraction in DC Microgrids

DC microgrids have promising applications in renewable integration due to their better energy efficiency when connecting DC components. However, they might be unstable since many loads in a DC microgrid are regulated as constant power loads (CPLs) that have a destabilizing negative impedance effect. As a result, the state trajectory displacement caused by abrupt load changes or contingencies can easily lead to instability. Many existing works have been devoted to studying the region of attraction (ROA) of a DC microgrid, in which the system is guaranteed to be asymptotically stable. Nevertheless, existing work either focuses on using numerical methods for ROA approximations that generally have no performance guarantees or cannot ensure a desired ROA for a general DC microgrid. To close this gap, this paper develops an innovative control synthesis algorithm to make a general DC microgrid have a theoretically guaranteed ROA, for example, to cover the entirety of its operating range regarding state trajectories. Here, we first study the nonlinear dynamics of a DC microgrid to derive a novel transient stability condition to rigorously certify whether a given operating range is a subset of the ROA; then, we formulate a control synthesis optimization problem to guarantee the condition’s satisfaction. This condition is a linear constraint, and the optimization problem resembles an optimal power flow problem and has a good computational behavior. Simulation case studies verify the validity of the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Networked Microgrids for Grid Resilience, Robustness, and Efficiency: A Review

Networked microgrids (NMGs) are clusters of microgrids that are physically connected and functionally interoperable. The massive and unprecedented deployment of smart grid technologies, new business models, and involvement of new stakeholders enable NMGs to be a conceptual operation paradigm for future distribution systems. Much work needs to be done, however, to enable NMGs to achieve seamless coordination, including physical, communication, and functional integration. In this paper, we review and summarize the state-of-the-art methodologies for operation and control of NMGs. Furthermore, we also specifically discuss the notion of dynamic boundaries for advanced microgrid applications. In addition, we introduce the opportunities, challenges, and possible solutions regarding NMGs for improving grid resilience, robustness, and efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy-Storage Fed Smart Inverters for Mitigation of Voltage Fluctuations in Islanded Microgrids

The continuous integration of intermittent low-carbon energy resources makes islanded microgrids vulnerable to voltage fluctuations. Besides, different dynamic response of synchronous-based and inverter-based distributed generation (DG) units can result in an instantaneous power imbalance between supply and demand during transients. As a result, the ac-bus voltage of microgrid starts oscillating which might have severe consequences such as blackouts. This paper modifies the conventional control scheme of battery energy storage systems (BESSs) to participate in improving the dynamic behavior of islanded microgrids by mitigating the voltage fluctuations. A piecewise linear-elliptic (PLE) droop is proposed and employed in BESS to achieve an enhanced voltage profile by injecting/absorbing reactive power during transients. In this way, the conventional inverter implemented in BESS turns into a smart inverter to cope with fast transients. Using the proposed approach in this paper, any linear droop curve with a specified coefficient can be replaced by a PLE droop curve. Compared with linear droop, an enhanced dynamic response is achieved by utilizing the proposed PLE droop. Case study results are presented using PSCAD/EMTDC to demonstrate the superiority of the proposed approach in improving the dynamic behavior of islanded microgrids.