Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “droplets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Interference of Backscatter from Two Droplets in a Focused Continuous Wave CO2 Doppler Lidar Beam

Interference due to the superposition of backscatter, beta, from two micron-sized droplets using a NASA/MSFC cw (continuous wave) CO2 Doppler lidar at 9.1 micrometer wavelength was detected for the first time. The resultant single beta signal from both droplets contained an interference structure with a well-defined periodicity which was accurately measured and compared with cw lidar theory. The agreement between measurements and theory is excellent, indicating that the interference arises because the droplets are moving at different speeds and, therefore, the relative droplet separation is not constant. This gives the superimposed beta signal from both droplets in the lidar beam moving in and out of constructive and destructive interference with a well-defined periodic structure. A measurement of a time-resolved signal pulse with an oscilloscope of the combined from two approx. 14.12 micrometers in diameter silicone oil droplets responding to the Gaussian lidar beam intensity at the lidar beam focus is shown. Full details of this laboratory experimental setup, particle generation method, measurement technique, and the cw lidar can be found elsewhere. The stream of silicone oil droplets resided at a Doppler-shift center frequency of f (sub D) approx. (3.4 plus or minus 0.2) MHz, giving droplet speed v approx.(21.9 plus or minus 1.3) ms (exp. -1). Also shown on a separate channel is the corresponding signature using an amplitude demodulator circuit designed to detect the amplitude envelope of f(sub D) within the pulse profile. beta from simultaneous droplet events show a complete cyclic interference structure of maximum and minimum. The average period T of the complete cycle of interference is 13.02 plus or minus.39 microseconds. Toward the right edge of the profile, the interference disappears because one of the droplets is leaving the lidar beam while the other one remains in the beam, thus, giving beta for a single droplet.

Jarzembski, Maurice A.↗

Combustion of Interacting Droplet Arrays in a Microgravity Environment

Investigations into droplet interactions date back to Rex et al. Annamalai and Ryan and Annamalai published extensive reviews of droplet array and cloud combustion studies. In the majority of the reviewed studies, the authors examined the change in the burning rate constant, k, (relative to that of the single droplet) that results from interactions. More recently, Niioka and co-workers have examined ignition and flame propagation along arrays of interacting droplets with the goal of relating these phenomena in this simplified geometry to the more practical spray configuration. Our work has focussed on droplet interactions under conditions where flame extinction occurs at a finite droplet diameter. In our previous work, we reported that in normal gravity, reduced pressure conditions, droplet interactions improved flame stability and extended flammability limits (by inference). In our recent work, we examine droplet interactions under conditions where the flame extinguishes at a finite droplet diameter in microgravity. The microgravity experiments were in the NASA GRC 2.2 and 5.2 second drop towers, and the JAMIC (Japan Microgravity Center) 10 second drop tower. We also present progress on a numerical model of single droplet combustion that is in the process of being extended to model a binary droplet array.

Dietrich, D. L.↗

Modular droplet actuator drive

A droplet actuator drive including a detection apparatus for sensing a property of a droplet on a droplet actuator; circuitry for controlling the detection apparatus electronically coupled to the detection apparatus; a droplet actuator cartridge connector arranged so that when a droplet actuator cartridge electronically is coupled thereto: the droplet actuator cartridge is aligned with the detection apparatus; and the detection apparatus can sense the property of the droplet on a droplet actuator; circuitry for controlling a droplet actuator coupled to the droplet actuator connector; and the droplet actuator circuitry may be coupled to a processor.

Pollack, Michael G.↗

Towards an Enhanced Droplet Activation Scheme for Multi-Moment Bulk Microphysics Schemes

Initial droplet spectra produced upon activation impact the ensuing chain of microphysical processes andtherefore play a crucial role in cloud evolution. This work re-examines dependencies of newly formed clouddroplet size distribution (CDSD) characteristics on environmental and aerosol properties via parcel model simulationsthat serve as the basis for a multi-moment bulk microphysics droplet activation scheme suitable for acloud-resolving model (CRM). It is found that applying a fixed size threshold to define activated droplets versusemploying physical considerations can lead to erroneous activation and overly broad CDSDs for high aerosolconcentration and weak updraft conditions. Aerosol distributions characterized by larger median sizes and/orincreased solubility can result in greater activated droplet numbers, whereas impacts of these parameters onCDSD spectral width depend on both aerosol number concentration and updraft velocity. An expansion of theactivation scheme to include CDSD spectral width is proposed to aid efforts to extend high-order momentprediction to cloud droplet categories in CRMs as well as better represent variability in the activation process onthe cloud scale.simulations to investigate the regime dependence of the relative dispersion(d)1 of newly activated CDSDs, where d is the ratio of dropletradius standard deviation (σ) to the mean radius (r ). C16 demonstratedthat increasing Na resulted in increasing (decreasing) d values via reducedcondensational narrowing (spectral broadening) rates within theAL (UL) regime, with d values peaking in the TR regime. Their findingssuggest a similar regime dependence for d as R09 noted for Nc and helpexplain reportedly conflicting relationships between Na and CDSDspectral characteristics (cf. Hudson and Noble, 2014; Liu et al., 2014),although the applicability of these results within bulk microphysicalschemes was not addressed.Simulating aerosol-cloud interactions with CRMs employing bulkmicrophysics requires that the scheme minimally predict two CDSDparameters, namely mass and number concentrations, and represent thedroplet activation process. Various activation schemes aim to determineNc from aerosol and environmental properties and include analyticalexpressions (e.g., Abdul-Razzak et al., 1998; Morrison et al., 2005) aswell as lookup tables (LUTs) based on detailed parcel model calculations(e.g., Saleeby and Cotton, 2004, hereafter SC04; Segal and Khain,2006; Thompson and Eidhammer, 2014). Expressions to diagnose CDSDspectral width from Nc (Grabowski, 1998; Liu et al., 2006; Morrison andGrabowski, 2007) or cloud water content (Geoffroy et al., 2010) havealso been developed, although more robust methods to obtain CDSDspectral width upon activation are presently lacking. This latter point isrelevant for triple-moment (3 M) bulk microphysics that aim to predictdistribution spectral width alongside number and mass concentrations(e.g., Loftus et al., 2014; Milbrandt and Yau, 2005).The current work extends the findings of C16 to the current LUTbasedaerosol activation scheme used in the Regional AtmosphericModeling System (RAMS) (Cotton et al., 2003; SC04; Saleeby and vanden Heever, 2013, hereafter SvdH13) and additionally examinesaerosol size and solubility impacts on newly activated CDSD properties.Because early cloud development processes such as condensationalgrowth, evaporation, and droplet self-collection depend on and impactCDSD spectral width (Hudson and Yum, 1997; Seifert and Beheng 2001;Lu and Seinfeld, 2006; Igel and van den Heever, 2017), an expansion ofthe activation LUTs to include CDSD spectral width is proposed as apreliminary step for extending 3M prediction to CDSDs in CRMs forimproved simulations of aerosol-cloud interactions.2. MethodologyThe current RAMS two-moment microphysics module determinesthe fractional number of aerosol particles that activate to cloud dropletsfrom five-dimensional LUTs based on model predicted air temperature(T), w, Na, and the geometric median radius (rg) and soluble fraction (ε)of the aerosol size distribution (SvdH13). These LUTs are created offlineusing a one-dimensional Lagrangian adiabatic parcel model (Feingoldand Heymsfield, 1992; Heymsfield and Sabin, 1989; SC04) to simulateexplicit droplet activation and initial CDSD growth for a range of ambientatmospheric conditions [T, w] and binned lognormal aerosol sizedistributions given by= ⎡⎣ ⎢− ⎤⎦ ⎥N r Nr π σr rσ( )2 lnexp[ln( / )]2(ln )aggg22 (1)where r is the dry aerosol particle bin radius and σg is the geometricstandard deviation of the distribution. As the parcel model simulationsfocus on the activation process, other processes such as coalescence,sedimentation, and mixing are not considered. Details of the parcelmodel can be found in SC04 and SvdH13, and only a brief description isprovided here. At the onset of parcel model calculations, the initiallydry aerosol particles in all bins first deliquesce and reach theirequilibrium diameters in a sub-saturated environment based on theKöhler equation for solution droplets. The parcel is then lifted at a fixedupward velocity w, and particle growth by vapor diffusion, along withconcurrent changes in the ambient environment, are iteratively computedusing the Variable-coefficient Ordinary Differential Equation(VODE) solver (Brown et al., 1989). The time resolution of these calculationsis determined within the VODE solver, and the frequency atwhich the solver is called is controlled by a longer model time stepbased on fixed upward parcel displacement increments (Δz) at thespecified w (Δt=Δz/w). Model calculations proceed until the parcelreaches a height 50m beyond the level of maximum saturation ratio(Smax) or total parcel displacement exceeds 2 km. Upon model termination,Smax and the fractional number of aerosols (factv) resulting innewly formed cloud droplets, defined as particles having diameters of atleast 2 μm, are cataloged in the LUTs according to the specified T, w, Na,rg, and ε parameter values.A critical point regarding the creation of these LUTs is the use of afixed minimum diameter (Dmin) to define cloud droplets in the parcelmodel, which can produce erroneous CDSD characteristics, particularlywithin the UL regime. For aerosol distributions with large rg valuesunder low SS conditions, for example, deliquesced aerosols within thelarge tail of the distribution can exceed 2 μm in diameter yet remainunactivated as ‘haze’ particles (Levin and Cotton, 2009; McFigganset al., 2006). For this study, aerosol particles activate to cloud dropletsbased on the critical diameter Dcrit as a function of parcel supersaturationratio (Sr) as in R09:D = σ MS RTρ83 ln( ) critsol wr w (2)where σsol is the surface tension of a solution droplet, Mw and ρw are themolar mass and density of liquid water, respectively, and R is theuniversal gas constant. Additionally, at relatively large w values withinthe AL regime, Nc stabilizes shortly after reaching supersaturation.However, parcel ascent and condensational growth continue beyondthe level of Smax, potentially causing additional narrowing of the CDSD.In the current work, model calculations terminate upon reaching Smaxas changes in Nc are negligible with continued ascent (Peng et al., 2007;R09).Parcel model simulations are performed to examine the sensitivitiesof CDSD characteristics to w, Na, rg, and ε, with the ranges for theseparameters listed in Table 1. Aerosols are assumed to be a mix of solubleand insoluble material of equal density, specified by ε, where fullysoluble aerosols correspond to ammonium sulfate with hygroscopicityparameter κ=0.61 (Petters and Kreidenweis, 2007). FollowingSvdH13, aerosol geometric standard deviation is fixed at σg=1.8, andaerosol distributions (Eq. 1) are partitioned into 100 logarithmicallyspacedbins spanning a size range specific to each rg value. For all simulations,Δz=1 m, and initial values of relative humidity, air temperatureand pressure are set to RH=0.99, T=10 °C and p=900 hPa,respectively.

Loftus, Adrian M.↗

Adaptation of a Cascade Impactor to Flight Measurement of Droplet Size in Clouds

A cascade impactor, an instrument for obtaining: the size distribution of droplets borne in a low-velocity air stream, was adapted for flight cloud droplet-size studies. The air containing the droplets was slowed down from flight speed by a diffuser to the inlet-air velocity of the impactor. The droplets that enter the impactor impinge on four slides coated with magnesium oxide. Each slide catches a different size range. The relation between the size of droplet impressions and the droplet size was evaluated so that the droplet-size distributions may be found from these slides. The magnesium oxide coating provides a permanent record. of the droplet impression that is not affected by droplet evaporation after the. droplets have impinged.

Levine, Joseph↗

Liquid droplet radiator thermal characteristics

The effects of droplet size, emissivity, and spacing on the liquid droplet radiator (LDR) performance space heat rejection system are investigated. The procedures for predicting surface emissivity of semitransparent droplets as a function of absorptivity and radius are examined. The relation between absorptivity, reflectivity, transmissivity, and emissivity is studied. It is observed that for droplets in the 25-200 micron range the radius affects emissivity. The thermal performance of an array of droplet streams is described using a thermal radiation model. Droplet temperatures are calculated; it is shown that outside droplet streams are more effective than interior droplets for arrays in the range of radius to spacing ratio from 0.05-0.2. Temperature distributions as a function of droplet size, emissivity, and velocity are presented. The heat transfer performance of a LDR is evaluated in terms of fin effectiveness. The equivalent sheet emissivities of droplet streams are examined.

Edgerton, R. H.↗

Simulation of water vapor condensation on LOX droplet surface using liquid nitrogen

The formation of ice or water layers on liquid oxygen (LOX) droplets in the Space Shuttle Main Engine (SSME) environment was investigated. Formulation of such ice/water layers is indicated by phase-equilibrium considerations under conditions of high partial pressure of water vapor (steam) and low LOX droplet temperature prevailing in the SSME preburner or main chamber. An experimental investigation was begun using liquid nitrogen as a LOX simulant. A monodisperse liquid nitrogen droplet generator was developed which uses an acoustic driver to force the stream of liquid emerging from a capillary tube to break up into a stream of regularly space uniformly sized spherical droplets. The atmospheric pressure liquid nitrogen in the droplet generator reservoir was cooled below its boiling point to prevent two phase flow from occurring in the capillary tube. An existing steam chamber was modified for injection of liquid nitrogen droplets into atmospheric pressure superheated steam. The droplets were imaged using a stroboscopic video system and a laser shadowgraphy system. Several tests were conducted in which liquid nitrogen droplets were injected into the steam chamber. Under conditions of periodic droplet formation, images of 600 micron diameter liquid nitrogen droplets were obtained with the stroboscopic video systems.

Powell, Eugene A.↗

Modeling of Non-Spherical Droplet Dynamics

A two-dimensional time-dependent computer code based on the modified Arbitrary Lagrangian Eulerian (ALE) technique, has been developed to simulate non-spherical droplet dynamics and evaporation under convective flows at real rocket combustion chamber conditions. The equations of mass, momentum, energy and species are simultaneously solved for both liquid and gas phases with an accurate dynamic interface tracking. The jump boundary conditions across the deforming droplet surface are obtained by applying the integral forms of conservation of mass, momentum, and energy. At each time step, the interface geometry and flow properties at the droplet surface are implicitly solved by satisfying the interface boundary conditions. A Lagrangian technique was developed to track the arbitrarily moving interface between the liquid droplet and the external gas. An elliptic grid generator is adopted to dynamically reconstruct grids both inside and outside the droplet surface. This code has been used to study droplet oscillation, droplet deformation/breakup, nonspherical droplet evaporation in both low and high pressure convective flows. This presentation briefly describes the numerical algorithm for modeling of the nonspherical droplet dynamics and demonstrates the representative simulation results of nonspherical droplet evaporation at low and high pressure convective flows. Potential applications of this code to rocket combustor design and performance predictions are discussed.

Deng, Zheng-Tao↗

Breakup of Droplets in an Accelerating Gas Flow

A study of droplet breakup phenomena by an accelerating gas flow is described. The phenomena are similar to what propellant droplets experience when exposed to accelerating combustion gas flow in a rocket engine combustion zone. Groups of several dozen droplets in the 100-10 750-micron-diameter range were injected into a flowing inert gas in a transparent rectangular nozzle. Motion photography of the behavior of the droplets at various locations in the accelerating gas flow has supplied quantitative and qualitative data on the breakup phenomena which occur under conditions similar to those found in large rocket engine combustors. A blowgun injection device, used to inject very small amounts of liquid at velocities of several hundred feet per second into a moving gas stream, is described. The injection device was used to inject small amounts of liquid RP-1 and water into the gas stream at a velocity essentially equal to the gas velocity where the group of droplets was allowed to stabilize its formation in a constant area section before entering the convergent section of the transparent nozzle. Favorable comparison with the work of previous investigators who have used nonaccelerating gas flow is found with the data obtained from this study with accelerating gas flow. The criterion for the conditions of minimum severity required to produce shear-type droplet breakup in an accelerating gas flow is found to agree well with the criterion previously established at Rocketdyne for breakup in nonaccelerating flow. An extension of the theory of capillary surface wave effects during droplet breakup is also presented. Capillary surface waves propagating in the surface of the droplet, according to classical hydrodynamical laws, are considered. The waves propagate tangentially over the surface of the droplet from the forward stagnation point to the major diameter. Consideration of the effects of relative gas velocity on the amplitude growth of these waves allows conclusions to be made regarding rates of the droplet breakup processes and total time of the breakup process.

Dickerson, R. A.↗

High-Voltage Droplet Dispenser Developed

Various techniques have been applied to deploying individual droplets for many applications, such as the study of the combustion of liquid fuels. Isolated droplet studies are useful in that they allow phenomena to be studied under well-controlled and simplified conditions. A high-voltage droplet dispenser has been developed that is extremely effective in dispensing a wide range of droplets. The dispenser is quite unique in that it utilizes a droplet bias voltage, as well as an ionization pulse, to release the droplet. The droplet is deployed from the end of a needle. A flat-tipped, stainless steel needle attached to a syringe dispenses a known value of liquid that hangs on the needle tip. Somewhat below the droplet is an annular ring electrode. A bias voltage, followed by a voltage pulse, is applied to attract the droplet sufficiently to pull it off the needle. The droplet and needle are oppositely charged relative to the annular electrode. The needle is negatively charged, and the annular ring is positively charged.

Eichenberg, Dennis J.↗

High-Voltage Droplet Dispenser

An apparatus that is extremely effective in dispensing a wide range of droplets has been developed. This droplet dispenser is unique in that it utilizes a droplet bias voltage, as well as an ionization pulse, to release a droplet. Apparatuses that deploy individual droplets have been used in many applications, including, notably, study of combustion of liquid fuels. Experiments on isolated droplets are useful in that they enable the study of droplet phenomena under well-controlled and simplified conditions. In this apparatus, a syringe dispenses a known value of liquid, which emerges from, and hangs onto, the outer end of a flat-tipped, stainless steel needle. Somewhat below the needle tip and droplet is a ring electrode. A bias high voltage, followed by a high-voltage pulse, is applied so as to attract the droplet sufficiently to pull it off the needle. The voltages are such that the droplet and needle are negatively charged and the ring electrode is positively charged.

Eichenberg, Dennis J.↗

The clouds of Venus. II - An investigation of the influence of coagulation on the observed droplet size distribution

An approximate numerical technique is used to investigate the influence of coagulation, sedimentation and turbulent motions on the observed droplet size distribution in the upper layers of the Venus clouds. If the cloud mass mixing ratio is less than 0.000001 at 250 K or the eddy diffusivity throughout the cloud is greater than 1,000,000 sq cm per sec, then coagulation is unimportant. In this case, the observed droplet size distribution is the initial size distribution produced by the condensation of the droplets. It is found that all cloud models with droplet formation near the cloud top (e.g., a photochemical model) must produce the observed droplet size distribution by condensation without subsequent modification by coagulation. However, neither meteoritic or surface dust can supply sufficient nucleating particles to account for the observed droplet number density. If the cloud droplets are formed near the cloud bottom, the observed droplet size distribution can be produced solely by the interaction of coagulation and dynamics; all information about the initial size distribution is lost. If droplet formation occurs near the cloud bottom, the lower atmosphere of Venus is oxidizing rather than reducing.

Rossow, W. B.↗

A Study of Large Droplet Ice Accretions in the NASA-Lewis IRT at Near-Freezing Conditions

This report documents the results of an experimental study on large droplet ice accretions which was conducted in the NASA-Lewis Icing Research Tunnel (IRT) with a full-scale 77.25 inch chord Twin-Otter wing section. This study was intended to: (1) document the existing capability of the IRT to produce a large droplet icing cloud, and (2) study the effect of various parameters on large droplet ice accretions. Results are presented from a study of the IRT's capability to produce large droplets with MVD of 99 and 160 microns. The effect of the initial water droplet temperature on the resultant ice accretion was studied for different initial spray bar air and water temperatures. The initial spray bar water temperature was found to have no discernible effect upon the large droplet ice accretions. Also, analytical and experimental results suggest that the water droplet temperature is very nearly the same as the tunnel ambient temperature, thus providing a realistic simulation of the large droplet natural icing condition. The effect of temperature, droplet size, airspeed, angle-of attack, flap setting and de-icer boot cycling time on ice accretion was studied, and will be discussed in this report. It was found that, in almost all of the cases studied, an ice ridge formed immediately aft of the active portion of the de-icer boot. This ridge was irregular in shape, varied in location, and was in some cases discontinuous due to aerodynamic shedding.

Miller, Dean R.↗

Emulsion Droplet Combustion in Microgravity: Water/Heptane Emulsions

This presentation reviews a series of experiments to further examine parametric effects on sooting processes of droplet flames in microgravity. The particular focus is on a fuel droplet emulsified with water, specifically emulsions of n-heptane as the fuel-phase and water as the dispersed phase. Water was selected as the additive because of its anticipated effect on soot formation, and the heptane fuel phase was chosen to theoretically reduce the likelihood of microexplosions because its boiling point is nearly the same as that of water: 100 C for water and 98 C for heptane. The water content was varied while the initial droplet diameter was kept within a small range. The experiments were carried out in microgravity to reduce the effects of buoyancy and to promote spherical symmetry in the burning process. Spherically symmetric droplet burning is a convenient starting point for analysis, but experimental data are difficult to obtain for this situation as evidenced by the fact that no quantitative data have been reported on unsupported emulsion droplet combustion in a convection-free environment. The present study improves upon past work carried out on emulsion droplet combustion in microgravity which employed emulsion droplets suspended from a fiber. The fiber can be instrusive to the emulsion droplet burning process as it can promote coalescence of the dispersed water phase and heterogeneous nucleation on the fiber. Prior work has shown that the presence of water in liquid hydrocarbons can have both beneficial and detrimental effects on the combustion process. Water is known to reduce soot formation and radiation heat transfer to combustor walls Gollahalli (1979) reduce flame temperatures and thereby NOx emissions, and encourage secondary droplet atomization or microexplosion. Water also tends to retard ignition and and promote early extinction. The former effect restricted the range of water volume fractions as discussed below.

Avedisian, C. Thomas↗

Global Survey of the Relationship Between Cloud Droplet Size and Albedo Using ISCCP

Aerosols affect climate through direct and indirect effects. The direct effect of aerosols (e.g., sulfates) includes reflection of sunlight back toward space and for some aerosols (e.g., smoke particles), absorption in the atmosphere; both effects cool the Earth's surface. The indirect effect of aerosols refers to the modification of cloud microphysical properties, thereby affecting the radiation balance. Higher concentrations of Cloud Condensation Nuclei (CCN) generally produce higher concentrations of cloud droplets, which are also usually assumed to lead to decreased cloud droplet sizes. The result is an increase in cloud albedo, producing a net radiative cooling, opposite to the warming caused by greenhouse gases (Charlson et al. 1992). The change in clouds that is directly induced by an increase of aerosol concentration is an increase of cloud droplet number density, N; but is is usually assumed that cloud droplet size decreases as if the water mass density Liquid Water Content (LWC) were constant. There is actually no reason why this should be the case. Shifting the cloud droplet size distribution to more numerous smaller droplets can change the relative rates of condensational and coalescence growth, leading to different LWC (e.g., Rossow 1978). Moreover, the resulting change in cloud albedo is usually ascribed to more efficient scattering by smaller droplets, when in fact it is the increase in droplet number density (assuming constant LWC) that produces the most important change in cloud albedo: e.g., holding N constant and decreasing the droplet size would actually decrease the scattering cross-section and, thus, the albedo much more than it is increased by the increased scattering efficiency.

Han, Qingyuan↗

Dynamics of Droplet Extinction in Slow Convective Flows

The classical model for droplet combustion predicts that the square of the droplet diameter decreases linearly with time. It also predicts that a droplet of any size will burn to completion over a period of time. However, it has been known for some time that under certain conditions flames surrounding a droplet, in a quiescent environment, could extinguish because of insufficient residence time for the chemistry to proceed to completion. This type of extinction that occurs for smaller droplets has been studied extensively in the past. Large droplets, on the other hand, exhibit a different type of extinction where excessive radiative heat loss from the flame zone leads to extinction. This mode of "radiative extinction" was theoretically predicted for droplet burning by Chao et al. and was observed in recent space experiments in a quiescent environment. Thus far, the fundamental flammability limit prescribed by radiative extinction of liquid droplets has been measured only under quiescent environmental conditions. In many space platforms, however, ventilation systems produce small convective flows and understanding of the influences of this convection on the extinction process will help better define the radiative extinction flammability boundaries. Boundaries defined by experiments and captured using theoretical models could provide enhanced fire safety margin in space explor1999063d investigation of convective effects will help in interpretations of burning-rate data obtained during free-floated droplet combustion experiments with small residual velocities.

Nayagam, V.↗

The Burning of Large N-Heptane Droplets in Microgravity

Experimental results are presented on the burning and sooting behavior of large n-heptane droplets in air at atmospheric pressure under microgravity conditions. The experiments were performed at the Japanese Microgravity Center (JAMIC) 10 sec dropshaft in Hokkaido, Japan. Soot volume fraction, burning rate, flame standoff and luminosity were measured for droplets of 2.6 mm and 2.9 mm in initial diameter. These are the largest droplets for which soot volume fraction measurements have ever been performed. Previous measurements of soot volume fractions for n-heptane droplets, confined to smaller droplet sizes of less than 1.8 mm, indicated that maximum soot volume fraction increased monotonically with initial droplet size. The new results demonstrate for the first time that sooting tendency is reduced for large droplets as it has been speculated previously but never confirmed experimentally. The lower soot volume fractions for the larger droplets were also accompanied by higher burning rates. The observed phenomenon is believed to be caused by the dimensional influence on radiative heat losses from the flame. Numerical calculations confirm that soot radiation affects the droplet burning behavior.

Manzello, Samuel L.↗

Radiative Heat Loss Measurements During Microgravity Droplet Combustion in a Slow Convective Flow

Radiative heat loss from burning droplets in a slow convective flow under microgravity conditions is measured using a broad-band (0.6 to 40 microns) radiometer. In addition, backlit images of the droplet as well as color images of the flame were obtained using CCD cameras to estimate the burning rates and the flame dimensions, respectively. Tests were carried out in air at atmospheric pressure using n-heptane and methanol fuels with imposed forced flow velocities varied from 0 to 10 centimeters per second and initial droplet diameters varied from 1 to 3 millimeters. Slow convective flows were generated using three different experimental configurations in three different facilities in preparation for the proposed International Space Station droplet experiments. In the 2.2 Second Drop-Tower Facility a droplet supported on the leading edge of a quartz fiber is placed within a flow tunnel supplied by compressed air. In the Zero-Gravity Facility (five-second drop tower) a tethered droplet is translated in a quiescent ambient atmosphere to establish a uniform flow field around the droplet. In the KC 135 aircraft an electric fan was used to draw a uniform flow past a tethered droplet. Experimental results show that the burn rate increases and the overall flame size decreases with increases in forced-flow velocities over the range of flow velocities and droplet sizes tested. The total radiative heat loss rate, Q(sub r), decreases as the imposed flow velocity increases with the spherically symmetric combustion having the highest values. These observations are in contrast to the trends observed for gas-jet flames in microgravity, but consistent with the observations during flame spread over solid fuels where the burning rate is coupled to the forced flow as here.

Hicks, Michael C.↗